Equalização e segmentação de imagens termográficas aplicadas à metodologia de inspeção de isoladores poliméricos.

OLIVEIRA, Renata Garcia Dutra de. 17 April 2018 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-04-17T16:49:57Z No. of bitstreams: 1 RENATA GARCIA DUTRA DE OLIVEIRA – DISSERTAÇÃO (PPGEE) 2017.pdf: 2837305 bytes, checksum: 244c93af337ec0f89cf4eb7ae057d905 (MD5) / Made available in DSpace on 2018-04-17T16:49:57Z (GMT). No. of bitstreams: 1 RENATA GARCIA DUTRA DE OLIVEIRA – DISSERTAÇÃO (PPGEE) 2017.pdf: 2837305 bytes, checksum: 244c93af337ec0f89cf4eb7ae057d905 (MD5) Previous issue date: 2017-03-31 / Capes / A análise da variação de temperatura ao longo do isolador, por meio da termografia, pode consistir em um dos métodos mais eficazes de avaliação de isoladores em serviço, pois considera o efeito combinado da poluição, do estresse elétrico, defeitos internos e das condições ambientais. No entanto, analisar apenas de modo visual imagens termográficas é difícil e, muitas vezes, apenas os engenheiros especializados são capazes de fazer julgamentos corretos. Neste trabalho foi desenvolvida uma técnica para análise de imagens termográficas baseada em expansão não-linear de sinais, equalização de histogramas e análise de componentes principais com o objetivo de auxiliar no diagnóstico do nível de degradação de isoladores poliméricos. O processamento digital das imagens termográficas permitiu a obtenção dos valores de temperatura que indicam o comportamento térmico dos isoladores sob inspeção. Ensaios em laboratório foram realizados com isoladores poliméricos de 230 kV, com diferentes níveis de degradação, com a finalidade de captar imagens utilizando uma câmera de detecção de radiação infravermelha. Os resultados evidenciam a eficiência da metodologia desenvolvida, atuando de forma semiautomática no processamento digital de imagens termográficas, para obtenção do perfil térmico dos isoladores inspecionados. Com base nos produtos do processamento digital das imagens termográficas, tem-se uma melhor avaliação dos níveis de degradação em que se encontram os isoladores, além de auxiliar de forma eficiente a tomada de decisão para a classificação dos seus estados operacionais. / The analysis of the temperature variation along the insulator through thermography can be one of the most effective methods of evaluating insulators in service, for it considers the combined effect of pollution, electrical stress, internal defects and environmental conditions. However, analyses based only on visual inspection of images are not enough. In fact, only specialized engineers are able to make correct judgments. In this work a computational routine was developed, based on the digital image processing. The routine utilizes the signal nonlinear expansion technique, histogram equalization and principal component analysis. The digital processing of the thermographic images is used to obtain the temperature values that indicate the thermal behavior of the insulators under inspection. Laboratory tests were performed with 230 kV polymeric insulators with different levels of degradation in order to capture images using an infrared radiation detection camera. The results demonstrate the efficiency of the digital thermographic imaging technique to obtain the thermal profile of the insulators inspected. Based on the products of the digital processing of the thermographic images, we have a better evaluation of the degradation levels of the insulators, besides efficiently support to the classification of the operational states of the insulators.
42

Aprimoramento da classificação de isoladores poliméricos por medições termográficas e radiação UV usando processamento de imagens e RNA.

RIBEIRO, Girlene Lima. 25 April 2018 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-04-25T18:49:44Z No. of bitstreams: 1 GIRLENE LIMA RIBEIRO – DISSERTAÇÃO (PPGEE) 2017.pdf: 3769966 bytes, checksum: 1e2c04beeac23084837591c1bfec0869 (MD5) / Made available in DSpace on 2018-04-25T18:49:44Z (GMT). No. of bitstreams: 1 GIRLENE LIMA RIBEIRO – DISSERTAÇÃO (PPGEE) 2017.pdf: 3769966 bytes, checksum: 1e2c04beeac23084837591c1bfec0869 (MD5) Previous issue date: 2017-03-31 / CNPq / Nesta pesquisa é desenvolvida uma metodologia para aprimoramento da classificação de isoladores poliméricos por medições termográficas e radiação UV utilizando o Processamento Digital de Imagens (PDI) e Redes Neurais Artificiais (RNAs). A metodologia é baseada na análise da ocorrência de descargas corona e nas variações de temperatura ao longo do isolador a fim de classificá-los quanto seu estado de degradação. Cada isolador utilizado foi submetido à tensão de 133 kV fase-terra durante um período de 30 minutos, com o objetivo de ocasionar aquecimento e evidenciar descargas corona nos isoladores. As medições foram realizadas utilizando um detector de corona para medição de UV e os dados de temperatura foram adquiridos utilizando-se um termovisor. As imagens adquiridas pelos instrumentos de monitoramento, durante os ensaios, foram submetidas a um processamento digital de imagem, para extrair informações de densidade de pixels, persistência das descargas e distâncias relativas das áreas de descargas ao isolador. A partir de informações obtidas de imagens de infravermelho (temperatura) foi aplicada a estatística descritiva e o teste discriminante de Fisher, para apresentar ao sistema de classificação, parâmetros objetivos e com alto nível de separabilidade. O sistema de classificação utilizou RNA para determinar o estado de degradação dos isoladores. A classificação foi realizada de forma individual e combinada, com vetores formados pelos atributos UV e infravermelho. O sistema desenvolvido permitiu o auxílio à tomada de decisões quanto à necessidade de intervenção ou não aos isoladores. A classificação dos isoladores, de forma individual, obteve acurácia média para temperatura de 80,00% e UV 74,05%. A classificação dos isoladores, de forma combinada (UV e infravermelho), obteve acurácia média de 92,58%, evidenciando o aprimoramento na classificação. / This research presents a methodology for the improvement of the classification of polymeric insulators by using thermographic measurements and UV radiation in combination with Digital Image Processing (DIP) and Artificial Neural Networks (ANNs). The methodology is based on the analysis of the occurrence of corona discharges and temperature variations along the insulator in order to classify their stage of degradation. Each insulator was subjected to the 133 kV phase-to-ground voltage over a period of 30 minutes, in order to cause heating and corona discharges in the insulators. The experiments were performed using a corona detector for UV measurement and the temperature data were acquired using a thermal imager. The images acquired by the monitoring instruments during the tests were subjected to digital image processing to extract information of pixel density, persistence of discharges and relative distances from the discharge areas to the insulator. From information obtained through infrared (temperature) images descriptive statistics and Fisher's discriminant test were applied to present objective parameters with high level of separability to the classification system. The classification system used ANN to determine the insulators degradation state. The classification was performed in individual and in combination ways, with vectors formed by UV and infrared attributes. The developed system helped on the decision making, concerning to the necessity of intervention or not to the insulators. The classification of the insulators, in an individual way, obtained accuracy for temperature of 80.00% and UV 74.05%. The classification of the isolators, combined (UV and infrared), obtained an average accuracy of 92.58%, evidencing the improvement in the classification.
43

Avaliação do comportamento de isoladores de média tensão frente a sobretensões atmosféricas bipolares / Evaluation of the behavior of medium insulators voltage to bidirectionally atmospheric overvoltage

Silva, Alexandre Rigotti 16 August 2018 (has links)
As linhas de distribuição de energia estão frequentemente expostas a sobretensões causadas por descargas atmosféricas diretas e indiretas. As formas de onda dessas sobretensões podem diferir bastante do impulso atmosférico normalizado utilizado em ensaios para verificação da adequação dos projetos das isolações dos equipamentos frente a sobretensões atmosféricas (1,2/ 50 µs). Diferentes modelos têm sido propostos para se estimar o desempenho das isolações frente a impulsos não normalizados, sendo o modelo do efeito disruptivo (disruptive effect model) um dos mais utilizados. Este trabalho visa avaliar o comportamento de isoladores de média tensão quando sujeitos a sobretensões atmosféricas bipolares oscilatórias. Simulações realizadas usando o \"Extended Rusck Model\"(ERM) e resultados de medições demonstram que a ocorrência de sobretensões bipolares oscilatórias em linhas de distribuição não é um fato raro, pois descargas atmosféricas podem, sob certas condições, induzir tensões com tais características. Modificações realizadas no circuito de um gerador de impulsos de alta tensão convencional permitiram a geração de tensões bipolares de três períodos distintos: 2,2 µs, 4,1 µs e 6,0 µs. Este trabalho investiga o comportamento de um típico isolador de porcelana tipo pino de 15 kV sujeito a um impulso bipolar, representativo de uma tensão induzida por um raio. Mostra-se que uma modificação no método proposto por Savadamuthu et al. para estimar a suportabilidade do isolamento de pequenos (alguns milímetros) sistemas de isolamento submetidos a tensões oscilantes bipolares leva a resultados promissores em termos de previsão da ocorrência de descargas no isolador de classe 15 kV. / Power lines are often exposed to surges caused by direct and indirect lightning. The waveforms of these overvoltages may differ significantly from the standard lightning impulse used in tests to verify the adequacy of equipment insulation designs against atmospheric overvoltages (1.2/50 µs). Different models have been proposed to estimate the performance of the insulation against non-normalized impulses, with the disruptive effect model being one of the most used. This work aims at evaluating the behavior of medium voltage insulators when subjected to bidirectionally oscillating voltages. Simulations run using the Extended Rusck Model (ERM) and measurement results show that the occurrence of bipolar oscillating overvoltages are not rare on power distribution lines, as lightning strokes can induce, under certain conditions, voltages with such characteristics. Modifications performed in the circuit of a conventional high voltage pulse generator allowed the generation of bipolar voltages of three distinct periods: 2.2 µs, 4.1 µs and 6.0 µs. This work investigates the behavior of a typical 15 kV pin-type porcelain insulator subjected to bipolar impulses representative of lightning-induced voltages. It is shown that a modification on the method proposed by Savadamuthu et al. to estimate the insulation strength of small (a few mm) insulation systems subjected to bipolar oscillating voltages leads to promising results in terms of predicting the occurrence of flashovers on the 15 kV insulator.
44

Modeling of the behavior of medium voltage insulators against lightning overvoltages / Modelagem do comportamento de isoladores de média tensão contra sobretensões de impulsos atmosféricos

Shigihara, Miltom 05 October 2015 (has links)
Lightning causes important transient disturbances on transmission and distribution systems, with consequent damages to equipment, outages, and general decrease of the power quality. The assessment of the lightning dielectric strength of power equipment is generally based on tests performed using the standard lightning impulse voltage (1.2 / 50 µs waveshape), although the characteristics of the lightning overvoltages depend on many parameters and may vary widely. The behavior of insulators when subject to non-standard impulses depends both on the voltage amplitude and waveshape, and therefore a reliable model is required to produce the corresponding volt-time curves. Although there is no method universally accepted for this purpose, one of the most used is the Disruptive Effect (DE) model, which is based on the integration method concept. The application of this model involves the estimation of some parameters for which different procedures have been proposed in the literature, as for instance the procedures by Darveniza and Vlastos, by Hileman, by Chowdhuri et al., and by Ancajima et al. Tests of representative lightning overvoltages were performed to obtain the critical flashover overvoltages (CFO) and the volt-time curves of typical porcelain pin-type insulators considering three standard medium-voltage distribution classes (15 kV, 24 kV, and 36 kV) and five impulse voltage waveshapes, of both polarities. These tests provided data for the analyses of the insulators\' behavior and the results obtained using the different procedures for estimating the DE parameters. It is shown that in some cases insulator flashover is not predicted. A new method is then developed and proposed for evaluating the dielectric behavior of MV insulators. The method is validated using the typical insulators of the three voltage classes and the five lightning impulse voltages considered, of positive and negative polarities. The calculated volt-time curves showed in general a good agreement with the measured results for all the cases studied. The mean difference between the measured and calculated times to breakdown, for all the cases considered, was about 1.3 s; while the maximum difference was 4.0 s. The application of the proposed method to evaluate the occurrence of insulator flashovers in the shield wire line (SWL) system implemented in the State of Rondônia due to nearby lightning strikes supports previous conclusions that indicate that lightning has a significant impact on the SWL system performance in regions with high ground flash density. / Descargas atmosféricas produzem distúrbios transitórios significativos em sistemas de transmissão e distribuição, com consequentes danos em equipamentos, interrupções e redução geral na qualidade de energia elétrica. A avaliação da suportabilidade dielétrica frente às descargas atmosféricas do equipamento de potência é geralmente baseada em ensaios realizados usando o impulso atmosférico de tensão normalizada (forma de onda 1.2 / 50 µs), contudo as características das sobretensões atmosféricas dependem de muitos parâmetros e podem variar amplamente. O comportamento dos isoladores quando sujeitos a impulsos não normalizados depende tanto da magnitude como da forma de onda da tensão, e então um modelo confiável é necessário para se obter as curvas tensão-tempo correspondentes. Embora não haja um método universalmente aceito para essa finalidade, um dos mais utilizados é o modelo de Efeito Disruptivo (DE), que é baseado no conceito do método de integração. A aplicação desse modelo envolve a estimativa de alguns parâmetros para os quais diferentes procedimentos têm sido propostos na literatura, como por exemplo, os procedimentos de Darveniza e Vlastos, de Hileman, de Chowdhuri et al. e de Ancajima et al. Ensaios de sobretensões atmosféricas representativas foram feitos para obter as tensões de descarga disruptiva (CFO) e as curvas de tensão-tempo de isoladores de porcelana típicos, tipo pino, considerando três classes de tensão de distribuição de média tensão (15 kV, 24 kV e 36 kV) e cinco formas de onda de impulso de tensão, de ambas as polaridades. Estes ensaios proporcionaram dados para as análises do comportamento dos isoladores e os resultados obtidos usando os diferentes procedimentos para estimar os parâmetros necessários para a aplicação do modelo do Efeito Disruptivo. É mostrado que em alguns casos a disrupção no isolador não é prevista por tais procedimentos. Um novo método é, então, desenvolvido e proposto para avaliar o comportamento dielétrico dos isoladores de média tensão. O método é validado usando os isoladores típicos das três classes de tensão e as cinco formas de tensões de impulso atmosféricos consideradas, de polaridades positiva e negativa. As curvas tensão-tempo calculadas mostraram, em geral, boa concordância com os resultados medidos para todos os casos estudados. A diferença média entre os tempos de disrupção medidos e calculados, para todos os casos considerados, foi da ordem de 1,3 s; enquanto a máxima diferença foi de 4,0 s. A aplicação do método proposto para avaliar a ocorrência de disrupções em isoladores do Sistema de Cabo Para-raios Energizados (PRE), implementado no estado de Rondônia, devido a descargas atmosféricas indiretas, apoia as conclusões previamente obtidas que indicam que as descargas atmosféricas têm impacto significativo sobre o desempenho do sistema PRE em regiões com alta densidade de descargas para solo.
45

Avaliação do comportamento dielétrico de isoladores de distribuição de média tensão frente a impulsos atmosféricos com formas de onda não normalizadas / Analysis of the dielectric behavior of medium voltage insulators under non-standard lightning impulse voltages

Braz, Celso Pereira 18 April 2011 (has links)
As linhas de distribuição de energia estão freqüentemente expostas a sobretensões causadas por descargas atmosféricas diretas e indiretas. As formas de onda dessas sobretensões têm uma faixa de variação muito ampla e podem diferir bastante do impulso atmosférico normalizado utilizado em ensaios para verificação da adequação dos projetos das isolações dos equipamentos frente a sobretensões atmosféricas (1,2 / 50 microssegundos). É fato conhecido que a suportabilidade das isolações depende não só da amplitude como da forma de onda das solicitações. Diferentes modelos têm sido propostos para se estimar o desempenho das isolações frente a impulsos não normalizados, sendo o modelo do efeito disruptivo (disruptive effect model) um dos mais utilizados. Existem, contudo, diferentes métodos de aplicação desse modelo, ou seja, diferentes formas de se estimar os parâmetros necessários para a sua aplicação. Este trabalho visa avaliar o comportamento dielétrico de isoladores de média tensão e analisar os principais métodos para estimativa da suportabilidade desses equipamentos frente a sobretensões atmosféricas com formas de onda diferentes da normalizada. Para essa avaliação foram realizados ensaios em um isolador tipo pino, de porcelana, com tensão nominal de 15 kV, nos quais foram utilizadas, além do impulso atmosférico normalizado, outras ondas selecionadas com base em resultados de medição e de cálculo. Modificações realizadas no circuito de um gerador de impulsos de alta tensão convencional permitiram a geração de tensões com formas de onda bastante semelhantes às de sobretensões induzidas por descargas atmosféricas tanto em linhas de tamanho natural como em experimentos realizados com modelo reduzido. São apresentados e discutidos os resultados dos ensaios de tensão disruptiva de impulso atmosférico a 50 % e as curvas tensão-tempo (U x t) obtidas para cada impulso, considerando ambas as polaridades. A avaliação dos métodos de aplicação do modelo do efeito disruptivo foi realizada com base em comparações entre as curvas tensão-tempo obtidas nos ensaios e as curvas previstas por cada modelo, para cada uma das ondas selecionadas. / Overhead distribution lines are often exposed to lightning overvoltages, whose waveshapes vary widely and can differ substantially from the standard impulse voltage waveshape used to test electric equipment insulation against lightning surges (1.2 / 50 microseconds wave). It is well known that the voltage withstand capability of insulation depends not only on the amplitude but also on the voltage waveshape. Different models have been proposed for predicting the strength of insulation subjected to impulses of non-standard waveshapes. One of the most commonly used is the \"disruptive effect model\". There are, however, different methods of applying this model, that is, different ways of estimating the parameters needed for its application. This thesis aims at evaluating the dielectric behavior of medium voltage insulators subjected to impulses of non-standard waveshapes, as well as at evaluating the main methods for predicting their dielectric strength against such impulses. For the analysis, tests were performed on a pin type porcelain insulator with rated voltage of 15 kV, using, besides the standard lightning impulse voltage waveshape, other s waveshapes selected based on the characteristics of measured and calculated lightning overvoltages. Modifications made to the circuit of a conventional impulse voltage generator allowed to obtain voltage waveshapes very similar to those of lightning-induced voltages measured in experiments conducted both in lines of natural size and in reduced model. The test results relative to the critical lightning impulse flashover voltage (U50) and the volt-time characteristics obtained for the positive and negative polarities of each waveshape are presented and discussed. The evaluation of the methods of determining the parameters of the disruptive effect model was based on comparisons between the volt-time curves obtained from the laboratory tests and those predicted by each method, for each of the selected voltage waveshapes.
46

Modeling of the behavior of medium voltage insulators against lightning overvoltages / Modelagem do comportamento de isoladores de média tensão contra sobretensões de impulsos atmosféricos

Miltom Shigihara 05 October 2015 (has links)
Lightning causes important transient disturbances on transmission and distribution systems, with consequent damages to equipment, outages, and general decrease of the power quality. The assessment of the lightning dielectric strength of power equipment is generally based on tests performed using the standard lightning impulse voltage (1.2 / 50 µs waveshape), although the characteristics of the lightning overvoltages depend on many parameters and may vary widely. The behavior of insulators when subject to non-standard impulses depends both on the voltage amplitude and waveshape, and therefore a reliable model is required to produce the corresponding volt-time curves. Although there is no method universally accepted for this purpose, one of the most used is the Disruptive Effect (DE) model, which is based on the integration method concept. The application of this model involves the estimation of some parameters for which different procedures have been proposed in the literature, as for instance the procedures by Darveniza and Vlastos, by Hileman, by Chowdhuri et al., and by Ancajima et al. Tests of representative lightning overvoltages were performed to obtain the critical flashover overvoltages (CFO) and the volt-time curves of typical porcelain pin-type insulators considering three standard medium-voltage distribution classes (15 kV, 24 kV, and 36 kV) and five impulse voltage waveshapes, of both polarities. These tests provided data for the analyses of the insulators\' behavior and the results obtained using the different procedures for estimating the DE parameters. It is shown that in some cases insulator flashover is not predicted. A new method is then developed and proposed for evaluating the dielectric behavior of MV insulators. The method is validated using the typical insulators of the three voltage classes and the five lightning impulse voltages considered, of positive and negative polarities. The calculated volt-time curves showed in general a good agreement with the measured results for all the cases studied. The mean difference between the measured and calculated times to breakdown, for all the cases considered, was about 1.3 s; while the maximum difference was 4.0 s. The application of the proposed method to evaluate the occurrence of insulator flashovers in the shield wire line (SWL) system implemented in the State of Rondônia due to nearby lightning strikes supports previous conclusions that indicate that lightning has a significant impact on the SWL system performance in regions with high ground flash density. / Descargas atmosféricas produzem distúrbios transitórios significativos em sistemas de transmissão e distribuição, com consequentes danos em equipamentos, interrupções e redução geral na qualidade de energia elétrica. A avaliação da suportabilidade dielétrica frente às descargas atmosféricas do equipamento de potência é geralmente baseada em ensaios realizados usando o impulso atmosférico de tensão normalizada (forma de onda 1.2 / 50 µs), contudo as características das sobretensões atmosféricas dependem de muitos parâmetros e podem variar amplamente. O comportamento dos isoladores quando sujeitos a impulsos não normalizados depende tanto da magnitude como da forma de onda da tensão, e então um modelo confiável é necessário para se obter as curvas tensão-tempo correspondentes. Embora não haja um método universalmente aceito para essa finalidade, um dos mais utilizados é o modelo de Efeito Disruptivo (DE), que é baseado no conceito do método de integração. A aplicação desse modelo envolve a estimativa de alguns parâmetros para os quais diferentes procedimentos têm sido propostos na literatura, como por exemplo, os procedimentos de Darveniza e Vlastos, de Hileman, de Chowdhuri et al. e de Ancajima et al. Ensaios de sobretensões atmosféricas representativas foram feitos para obter as tensões de descarga disruptiva (CFO) e as curvas de tensão-tempo de isoladores de porcelana típicos, tipo pino, considerando três classes de tensão de distribuição de média tensão (15 kV, 24 kV e 36 kV) e cinco formas de onda de impulso de tensão, de ambas as polaridades. Estes ensaios proporcionaram dados para as análises do comportamento dos isoladores e os resultados obtidos usando os diferentes procedimentos para estimar os parâmetros necessários para a aplicação do modelo do Efeito Disruptivo. É mostrado que em alguns casos a disrupção no isolador não é prevista por tais procedimentos. Um novo método é, então, desenvolvido e proposto para avaliar o comportamento dielétrico dos isoladores de média tensão. O método é validado usando os isoladores típicos das três classes de tensão e as cinco formas de tensões de impulso atmosféricos consideradas, de polaridades positiva e negativa. As curvas tensão-tempo calculadas mostraram, em geral, boa concordância com os resultados medidos para todos os casos estudados. A diferença média entre os tempos de disrupção medidos e calculados, para todos os casos considerados, foi da ordem de 1,3 s; enquanto a máxima diferença foi de 4,0 s. A aplicação do método proposto para avaliar a ocorrência de disrupções em isoladores do Sistema de Cabo Para-raios Energizados (PRE), implementado no estado de Rondônia, devido a descargas atmosféricas indiretas, apoia as conclusões previamente obtidas que indicam que as descargas atmosféricas têm impacto significativo sobre o desempenho do sistema PRE em regiões com alta densidade de descargas para solo.
47

Avaliação do comportamento dielétrico de isoladores de distribuição de média tensão frente a impulsos atmosféricos com formas de onda não normalizadas / Analysis of the dielectric behavior of medium voltage insulators under non-standard lightning impulse voltages

Celso Pereira Braz 18 April 2011 (has links)
As linhas de distribuição de energia estão freqüentemente expostas a sobretensões causadas por descargas atmosféricas diretas e indiretas. As formas de onda dessas sobretensões têm uma faixa de variação muito ampla e podem diferir bastante do impulso atmosférico normalizado utilizado em ensaios para verificação da adequação dos projetos das isolações dos equipamentos frente a sobretensões atmosféricas (1,2 / 50 microssegundos). É fato conhecido que a suportabilidade das isolações depende não só da amplitude como da forma de onda das solicitações. Diferentes modelos têm sido propostos para se estimar o desempenho das isolações frente a impulsos não normalizados, sendo o modelo do efeito disruptivo (disruptive effect model) um dos mais utilizados. Existem, contudo, diferentes métodos de aplicação desse modelo, ou seja, diferentes formas de se estimar os parâmetros necessários para a sua aplicação. Este trabalho visa avaliar o comportamento dielétrico de isoladores de média tensão e analisar os principais métodos para estimativa da suportabilidade desses equipamentos frente a sobretensões atmosféricas com formas de onda diferentes da normalizada. Para essa avaliação foram realizados ensaios em um isolador tipo pino, de porcelana, com tensão nominal de 15 kV, nos quais foram utilizadas, além do impulso atmosférico normalizado, outras ondas selecionadas com base em resultados de medição e de cálculo. Modificações realizadas no circuito de um gerador de impulsos de alta tensão convencional permitiram a geração de tensões com formas de onda bastante semelhantes às de sobretensões induzidas por descargas atmosféricas tanto em linhas de tamanho natural como em experimentos realizados com modelo reduzido. São apresentados e discutidos os resultados dos ensaios de tensão disruptiva de impulso atmosférico a 50 % e as curvas tensão-tempo (U x t) obtidas para cada impulso, considerando ambas as polaridades. A avaliação dos métodos de aplicação do modelo do efeito disruptivo foi realizada com base em comparações entre as curvas tensão-tempo obtidas nos ensaios e as curvas previstas por cada modelo, para cada uma das ondas selecionadas. / Overhead distribution lines are often exposed to lightning overvoltages, whose waveshapes vary widely and can differ substantially from the standard impulse voltage waveshape used to test electric equipment insulation against lightning surges (1.2 / 50 microseconds wave). It is well known that the voltage withstand capability of insulation depends not only on the amplitude but also on the voltage waveshape. Different models have been proposed for predicting the strength of insulation subjected to impulses of non-standard waveshapes. One of the most commonly used is the \"disruptive effect model\". There are, however, different methods of applying this model, that is, different ways of estimating the parameters needed for its application. This thesis aims at evaluating the dielectric behavior of medium voltage insulators subjected to impulses of non-standard waveshapes, as well as at evaluating the main methods for predicting their dielectric strength against such impulses. For the analysis, tests were performed on a pin type porcelain insulator with rated voltage of 15 kV, using, besides the standard lightning impulse voltage waveshape, other s waveshapes selected based on the characteristics of measured and calculated lightning overvoltages. Modifications made to the circuit of a conventional impulse voltage generator allowed to obtain voltage waveshapes very similar to those of lightning-induced voltages measured in experiments conducted both in lines of natural size and in reduced model. The test results relative to the critical lightning impulse flashover voltage (U50) and the volt-time characteristics obtained for the positive and negative polarities of each waveshape are presented and discussed. The evaluation of the methods of determining the parameters of the disruptive effect model was based on comparisons between the volt-time curves obtained from the laboratory tests and those predicted by each method, for each of the selected voltage waveshapes.
48

[pt] EFEITOS DE INTERAÇÃO E PERCOLAÇÃO NOS ESTADOS TOPOLÓGICOS DE BORDA / [en] EFFECTS OF INTERACTION AND PERCOLATION ON TOPOLOGICAL EDGE STATES

ANTONIO FEDERICO ZEGARRA BORRERO 18 June 2021 (has links)
[pt] Nesta tese estudamos dois importantes sistemas de Isoladores Topológicos (TIs), onde nos concentramos particularmente no papel das interações e percolação nos estados de borda topológicos. Primeiro, analisamos o papel das interações vizinhas mais próximas em um protótipo de TI unidimensional, o modelo Su-Schrieffer-Heeger (SSH). Com base em um formalismo de função de Green, aplicamos a equação de Dyson em combinação com a aproximação da matriz-T para verificar a correspondência bulk-edge na presença de interações. Os expoentes críticos próximos às transições de fase topológicas são os mesmos do modelo SSH não interagente, indicando que o sistema permanece na mesma classe de universalidade, apesar da presença de interações. O segundo sistema é um TI bidimensional simétrico na inversão de tempo, ou seja, o modelo de Bernevig-Hughes-Zhang (BHZ) em conjunto com um metal ferromagnético com quebra de reversão do tempo (FMM), onde investigamos a percolação do estado Hall de spin quântico do modelo BHZ para o FMM por meio de um modelo de ligações fortes (tight-binding). Demonstramos que dependendo de se o estado de borda do cone de Dirac submerge nas sub-bandas do FMM e da direção da magnetização do FMM, a percolação do estado de borda e seu spin-momentum-locking são afetados de maneiras diferentes. Surpreendentemente, descobrimos que a corrente de spin de borda de equilíbrio no modelo BHZ, naturalmente esperada dos estados de borda de propagação do spin polarizado, está de fato ausente devido ao cancelamento das bandas de valência. No entanto, fluxos laminares de correntes de carga e spin persistente à temperatura ambiente são produzidos perto da interface da junção BHZ / FMM. Usando teoria de resposta linear, investigamos a polarização de spin induzida pela corrente causada pela percolação do estado de borda, que serve como um torque de rotação que é encontrado ser predominantemente field-like. Além disso, a polarização do spin é dramaticamente aumentada perto das impurezas na borda do modelo BHZ. / [en] In this thesis we studied two important Topological Insulators (TIs), where we focused particularly on the role of interactions and percolation on the topological edge states. First, we analyzed the role of nearest-neighbor interactions in a prototype one-dimensional TI, namely the Su-Schrieffer-Heeger (SSH) model. Based on a Green s function formalism, we applied Dyson s equation in combination with T-matrix approximation to verify the bulk-edge correspondence in the presence of interactions. The critical exponents near topological phase transitions are found to be the same as the noninteracting SSH model, indicating that the system stays in the same universality class despite the presence of interactions. The second system is a two-dimensional timereversal symmetric TI, namely the Bernevig-Hughes-Zhang (BHZ) model in conjunction with a time-reversal breaking ferromagnetic metal (FMM), where we investigated the percolation of the quantum spin Hall state from the TI layer to the FMM by means of a tight-binding model. We demonstrated that depending on whether the edge state Dirac cone submerges into the FMM subbands and the direction of the magnetization of the FMM, the percolation of the edge state and its spin-momentum locking are affected in different ways. Surprisingly, we uncover that the equilibrium edge spin current in the BHZ model, naturally expected from the spin polarized propagating edge states, is in fact absent due to the cancellation from the valence bands. Nevertheless, laminar flows of room temperature persistent charge and spin currents are produced near the interface of the BHZ/FMM junction. Using a linear response theory, we investigate the current-induced spin polarization caused by the percolation of the edge state, which serves as a spin torque that is found to be predominantly field-like. Moreover, the spin polarization is dramatically enhanced near the impurities at the edge of the BHZ model.
49

[en] DESIGN AND DEVELOPMENT OF MEASUREMENT SYSTEM FOR IMPULSE VOLTAGE PUNCTURE TESTING ON INSULATORS / [pt] PROJETO E DESENVOLVIMENTO DE SISTEMA DE MEDIÇÃO PARA ENSAIOS DE IMPULSO DE PERFURAÇÃO EM ISOLADORES

IGHOR SOUZA DOS SANTOS 30 April 2020 (has links)
[pt] O ensaio de impulso para perfuração de isoladores é um ensaio normalizado descrito na IEC 61211:2004 e é fundamental para verificar em laboratório a qualidade de isoladores de vidro ou porcelana utilizados no sistema elétrico de potência. A norma IEC 60060-2:2010 recomenda que a calibração dos Sistemas de Medição utilizados em ensaios para Perfuração de Isoladores (SMIP) deve ser realizada por comparação com um padrão. Contudo, embora o ensaio de perfuração seja normalizado, ainda não existem padrões para rastrear esse sistema de medição na maioria dos institutos de pesquisas em âmbito global. Quantificar a amplitude de um impulso de perfuração, com todas as garantias metrológicas, não é uma tarefa trivial, por se tratar de um sinal impulsivo com amplitude de centenas de kilovolts e durações da ordem de 200 ns. Além disso, divisores de tensão com alto desempenho dinâmico para essa aplicação especifica também não estão disponíveis comercialmente. Deste modo, o objetivo desta dissertação foi projetar e desenvolver um SMIP. O divisor de tensão, integrante do sistema de medição, foi construído a fim de garantir uma mínima indutância e um alto desempenho dinâmico. Também foi desenvolvido um filtro para a remoção de interferências eletromagnéticas baseado na transformada wavelet, integrado a um software que controla aquisição, condicionamento do sinal, determinação e análise dos parâmetros do impulso de perfuração. O desempenho do sistema de medição foi avaliado em baixa tensão e em alta tensão, bem como foi estimada sua incerteza de medição, sendo então capaz de atender às exigências normativas e metrológicas do Laboratório de Referência em medição do Cepel. / [en] Impulse testing for puncture insulator is a standardized test described in IEC 61211:2004 and is essential for laboratory testing of the quality of glass or porcelain insulators used in the electrical power system. IEC 60060-2:2010 recommends that calibration of Measurement Systems used in Impulse Puncture Test on insulators (IPMS) should be performed by comparison against a standard. However, although the impulse puncture testing is standardized, there are still no standards for traceability of this measurement system at most research institutes globally. Quantifying the amplitude of an impulse puncture test, with all metrological guarantees, is not a trivial task, since it is an impulsive signal with amplitude of hundreds of kilovolts and durations of the order of 200 ns. In addition, high dynamic performance voltage dividers for this specific application are not commercially available either. Thus, the objective of this dissertation was to design and develop an IPMS. The voltage divider, which is part of the measuring system, is designed to ensure minimum inductance and high dynamic performance. A filter for electromagnetic interference removal based on the wavelet transform was also developed, integrated with software that controls acquisition, signal conditioning, determination and analysis of the impulse puncture testing parameters. The performance of the measuring system was evaluated at low voltage and high voltage, as well as its measurement uncertainty was estimated, being able to meet the normative and metrological requirements of the Cepel s Measurement Reference Laboratory.
50

Desenvolvimento de metodologia para análise de arborescências em materiais dielétricos por contraste de fase de raios X

Ribeiro Júnior, Sebastião 17 September 2013 (has links)
A ocorrência de arborescências em água (water tree) ou elétrica (electrical tree) é apontada como o principal fenômeno de degradação em isolações sólidas de cabos de distribuição de energia elétrica. A evolução destas arborescências pode levar a camada de isolação à ruptura dielétrica e, como conseqüência, à falha destes equipamentos, com a interrupção do fornecimento de energia elétrica. O entendimento deste fenômeno é necessário para desenvolver métodos de análise e prevenção da ruptura de materiais isolantes. Este trabalho mostra a aplicação da técnica contraste de fase por raios X como metodologia para o estudo das arborescências formadas em materiais isolantes de borracha de propileno etileno (EPR) e polietileno reticulado (XLPE). / The water tree or electrical tree occurrence is identified as the main phenomena in the degradation in solid isolations of the electric energy distribution cables. The water tree evolution can lead to dielectric breakdown of the isolation layer and, consequently, to the failure this equipment and the interruption of the electric energy supply. The understanding this phenomenon is necessary for the development analysis methods and to prevent collapse in the polymeric insulation. This work demonstrates the application of X-ray phase contrast technique as a methodology for the study of the water tree and electrical tree in Ethylene propylene rubber (EPR) and crosslinked polyethylene (XLPE).

Page generated in 0.0475 seconds