• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Dégradation chimique et biologique de neuf contaminants émergents dans les eaux de surfaces et les effluents primaires d’eaux usées municipales

Cormier, Guillaume 04 1900 (has links)
Un protocole inspiré du test de simulation 309 de l’Organisation de coopération et de développement économiques (OCDE) nous a permis de mesurer la dégradation chimique (excluant la photolyse) dans des eaux de surface de même que la dégradation chimique et biologique de neuf contaminants émergents dans l’effluent d’un décanteur primaire d’eau usée municipale. Les données étaient compatibles avec le modèle de cinétique de pseudo ordre un. Les résultats démontrant une persistance de plus d’un an dans les eaux de surface et de 71 jours dans l’effluent du décanteur primaire suggèrent que les dégradations chimique et biologique ne contribuent pas significativement à la diminution de: atrazine, déséthylatrazine, carbamazépine et diclofénac dans la phase aqueuse des systèmes testés. Les autres composés se sont dégradés à différents niveaux. Le 17ß-estradiol ainsi que l’éthinylestradiol, la noréthindrone, la caféine et le sulfaméthoxazole ont tous été sujet à la dégradation biologique dans les effluents du décanteur primaire d’eau usée avec des constantes de dégradation k et des demi-vies t1/2 mesurées allant respectivement de 0.0082 à 0.59 j-1 et de 1.2 à 85 jours. Les paramètres de cinétique mesurés peuvent être combinés aux concentrations typiques des composés à l’étude dans un décanteur primaire d’eau usée pour y calculer leur vitesse de dégradation. Cependant, puisque les décanteurs primaires dans les usines de traitement d’eaux usées ont généralement des temps de résidence de quelques heures seulement, il est improbable que les neufs contaminants émergents à l’étude diminuent significativement par ces processus durant leur passage dans le compartiment. / A protocol inspired by the OECD 309 simulation test allowed us to measure the chemical (excluding photolysis) degradation in surface waters as well as the chemical and biological degradation potential of 9 emerging contaminants in urban primary settling tank (PST) effluents. The data confirmed that a pseudo first order kinetic model provided a good fit. The results suggest that chemical and biological degradation will not significantly contribute to the disappearance of atrazine, desethylatrazine, carbamazepine and sulfamethoxazole in the aqueous phase of the tested systems given the reported persistency of more than a year in surface waters and 71 days in PST effluents. Other compounds were more easily degraded and 17ß-estradiol, ethinylestradiol, norethindrone, caffeine and sulfamethoxazole were all amenable to biological degradation in PST effluents, with measured degradation rate constants k and half-lives ranging respectively from 0.0082-0.59 d-1 and 1.2-85 days. Since PSTs in WWTPs generally have a water residence time of a few hours and considering the typical concentrations of such ECs’ in those compartments, it is unlikely that significant disappearance will occur during their passage through the PST.
2

Développement d’une nouvelle méthode d’analyse multi-résidus par LDTD/APCI-MS/MS pour la quantification de pesticides et de produits pharmaceutiques dans les eaux usées

Boisvert, Michel 04 1900 (has links)
Une nouvelle méthode d'extraction en phase solide (SPE) couplée à une technique d'analyse ultrarapide a été développée pour la détermination simultanée de neuf contaminants émergents (l'atrazine, le déséthylatrazine, le 17(béta)-estradiol, l'éthynylestradiol, la noréthindrone, la caféine, la carbamazépine, le diclofénac et le sulfaméthoxazole) provenant de différentes classes thérapeutiques et présents dans les eaux usées. La pré-concentration et la purification des échantillons a été réalisée avec une cartouche SPE en mode mixte (Strata ABW) ayant à la fois des propriétés échangeuses de cations et d'anions suivie d'une analyse par une désorption thermique par diode laser/ionisation chimique à pression atmosphérique couplée à la spectrométrie de masse en tandem (LDTD-APCI-MS/MS). La LDTD est une nouvelle méthode d'introduction d'échantillon qui réduit le temps total d'analyse à moins de 15 secondes par rapport à plusieurs minutes avec la chromatographie liquide couplée à la spectrométrie de masse en tandem traditionnelle (LC-MS/MS). Plusieurs paramètres SPE ont été évalués dans le but d'optimiser l'efficacité de récupération lors de l'extraction des analytes provenant des eaux usées, tels que la nature de la phase stationnaire, le débit de chargement, le pH d'extraction, le volume et la composition de la solution de lavage et le volume de l'échantillon initial. Cette nouvelle méthode a été appliquée avec succès à de vrais échantillons d'eaux usées provenant d'un réservoir de décantation primaire. Le recouvrement des composés ciblés provenant des eaux usées a été de 78 à 106%, la limite de détection a été de 30 à 122 ng L-1, alors que la limite de quantification a été de 88 à 370 ng L-1. Les courbes d'étalonnage dans les matrices d'eaux usées ont montré une bonne linéarité (R2 > 0,991) pour les analytes cibles ainsi qu’une précision avec un coefficient de variance inférieure à 15%. / A new solid phase extraction (SPE) method coupled to a high throughput sample analysis technique was developed for the simultaneous determination of nine selected emerging contaminants (atrazine, desethylatrazine, 17(beta)-estradiol, ethynylestradiol, northindrone, caffeine, carbamazepine, diclofenac and sulfamethoxazole) comprising drugs from different therapeutic classes present in wastewater. Sample pre-concentration and clean-up was performed with a mixed-mode SPE cartridge (Strata ABW) having both cation and anion exchange properties followed by analysis by laser diode thermal desorption/atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). The LDTD is a new high-throughput sample introduction method, which reduces total analysis time to less than 15 seconds compared to minutes with traditional liquid-chromatography coupled to tandem mass spectrometry (LC-MS/MS). Several SPE parameters were evaluated in order to optimize recovery efficiencies when extracting analytes from wastewater, such as the nature of stationary phase, the loading flow rate, the extraction pH, the various volume and composition of the washing solution and the initial sample volume. The method was successfully applied to real wastewater samples from a primary sedimentation tank. Recoveries of target compounds from wastewater ranged from 78 to 106 %, the limit of detection ranged from 30 to 122 ng L-1 while the limit of quantification ranged from 88 to 370 ng L-1. Calibration curves in wastewater matrix showed good linearity (R2 > 0.991), for all target analytes, and precision (intraday and interday) showed a coefficient of variance below 15%.
3

Développement d’une nouvelle méthode d’analyse multi-résidus par LDTD/APCI-MS/MS pour la quantification de pesticides et de produits pharmaceutiques dans les eaux usées

Boisvert, Michel 04 1900 (has links)
Une nouvelle méthode d'extraction en phase solide (SPE) couplée à une technique d'analyse ultrarapide a été développée pour la détermination simultanée de neuf contaminants émergents (l'atrazine, le déséthylatrazine, le 17(béta)-estradiol, l'éthynylestradiol, la noréthindrone, la caféine, la carbamazépine, le diclofénac et le sulfaméthoxazole) provenant de différentes classes thérapeutiques et présents dans les eaux usées. La pré-concentration et la purification des échantillons a été réalisée avec une cartouche SPE en mode mixte (Strata ABW) ayant à la fois des propriétés échangeuses de cations et d'anions suivie d'une analyse par une désorption thermique par diode laser/ionisation chimique à pression atmosphérique couplée à la spectrométrie de masse en tandem (LDTD-APCI-MS/MS). La LDTD est une nouvelle méthode d'introduction d'échantillon qui réduit le temps total d'analyse à moins de 15 secondes par rapport à plusieurs minutes avec la chromatographie liquide couplée à la spectrométrie de masse en tandem traditionnelle (LC-MS/MS). Plusieurs paramètres SPE ont été évalués dans le but d'optimiser l'efficacité de récupération lors de l'extraction des analytes provenant des eaux usées, tels que la nature de la phase stationnaire, le débit de chargement, le pH d'extraction, le volume et la composition de la solution de lavage et le volume de l'échantillon initial. Cette nouvelle méthode a été appliquée avec succès à de vrais échantillons d'eaux usées provenant d'un réservoir de décantation primaire. Le recouvrement des composés ciblés provenant des eaux usées a été de 78 à 106%, la limite de détection a été de 30 à 122 ng L-1, alors que la limite de quantification a été de 88 à 370 ng L-1. Les courbes d'étalonnage dans les matrices d'eaux usées ont montré une bonne linéarité (R2 > 0,991) pour les analytes cibles ainsi qu’une précision avec un coefficient de variance inférieure à 15%. / A new solid phase extraction (SPE) method coupled to a high throughput sample analysis technique was developed for the simultaneous determination of nine selected emerging contaminants (atrazine, desethylatrazine, 17(beta)-estradiol, ethynylestradiol, northindrone, caffeine, carbamazepine, diclofenac and sulfamethoxazole) comprising drugs from different therapeutic classes present in wastewater. Sample pre-concentration and clean-up was performed with a mixed-mode SPE cartridge (Strata ABW) having both cation and anion exchange properties followed by analysis by laser diode thermal desorption/atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). The LDTD is a new high-throughput sample introduction method, which reduces total analysis time to less than 15 seconds compared to minutes with traditional liquid-chromatography coupled to tandem mass spectrometry (LC-MS/MS). Several SPE parameters were evaluated in order to optimize recovery efficiencies when extracting analytes from wastewater, such as the nature of stationary phase, the loading flow rate, the extraction pH, the various volume and composition of the washing solution and the initial sample volume. The method was successfully applied to real wastewater samples from a primary sedimentation tank. Recoveries of target compounds from wastewater ranged from 78 to 106 %, the limit of detection ranged from 30 to 122 ng L-1 while the limit of quantification ranged from 88 to 370 ng L-1. Calibration curves in wastewater matrix showed good linearity (R2 > 0.991), for all target analytes, and precision (intraday and interday) showed a coefficient of variance below 15%.

Page generated in 0.0119 seconds