• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Lautheitsbeurteilung unilateraler Cochlea-Implantat-Träger in Abhängigkeit von der Stimulusart und vom vorangehenden Stimulus bei sequenzieller Darbietung der Reize / Loudness perception of patients with unilateral cochlear implant in dependency on the stimulus type and the predecessor for sequential presentation of stimuli

Kaulitz, Stefan January 2007 (has links) (PDF)
Bei der Anpassung eines Cochlea-Implantates (CI) entscheidet der Patient über die Lautstärke, mit der das CI ihm seine akustische Umwelt präsentiert. Mit der Methode der „kategorialen Lautheitsskalierung“ wurden Lautheitsurteile unilateraler CI-Träger ermittelt und ausgewertet. 26 unilateral versorgte CI-Träger beurteilten in 4 Versuchsabschnitten je einen Stimulustyp, der 169 mal mit 13 unterschiedlichen Lautstärken in festem zeitlichem Raster sequenziell dargeboten wurde. Der Sequenzaufbau stellte jeden Pegel jedem anderen möglichen Pegel als Vorgänger voran. Von jedem der Probanden wurden so 676 Lautheitsurteile erhoben und der statistischen Auswertung zugeführt. Probandenindividuell schwankten die Lautheitsurteile in Lage und Streuung. Mehrere Ergebnisse dieser Arbeit sind annähernd identisch mit denen einer Referenzgruppe von 26 Normalhörenden, die in einer Vorgängerarbeit mit dem gleichen Versuchsaufbau getestet worden waren. So wurden schmalbandige Stimuli signifikant leiser beurteilt als breitbandige. Beide Probandenkollektive zeigten eine positive Vorgängerpegelabhängigkeit sowie eine (signifikant stärkere) Vorgängerurteilsabhängigkeit. Sowohl bei den CI-Trägern als auch bei den Normalhörenden ging jede Erhöhung des Pegels um 5 dB mit einer signifikanten Erhöhung des Lautheitsurteils einher (strenge Monotonität). Die Lautheitsempfindungskurve der CI-Träger über alle Probanden und Stimuli verlief kontinuierlich unterhalb der der Normalhörenden. So wurde bei Sprachlautstärke (60–70 dB) gleiche Lautheit in der CI-Gruppe im Vergleich zur Referenzgruppe bei ca. 5 dB höheren Pegeln empfunden. Die unterschiedliche Lautheitsempfindung ist hinreichend durch die binaurale Hörsituation der Normalhörenden im Gegensatz zur monauralen der CI-Gruppe zu erklären. Es muss angenommen werden, dass die getesteten CI-Träger mit mindestens sechs Anpasssitzungen vor der Versuchsteilnahme über ausreichend Erfahrung zur Festlegung ihrer individuellen, idealen Lautstärke für den Alltagsgebrauch verfügten und diese an der Sprachlautstärke orientierten. Es bleibt Gegenstand weiterer Untersuchungen, warum unilaterale CI-Träger trotz der technischen Möglichkeit im Rahmen der Anpasssitzungen keine Kompensation des Lautheitsunterschiedes wünschen. / To investigate the overall level of loudness perception of cochlear implant (CI) users, 26 unilaterally implanted subjects (Med-El C40+ with Tempo+-processor) performed loudness scaling tasks. Four different types of stimuli, two narrow band and two broad band signals (1 kHz pure tone, warble tone, CCITT speech spectrum noise and a speech signal of 1 s duration each) were presented at 13 different SPLs in 5 db steps from 30 dB to 90 dB. The stimuli were presented in free field condition in an anechoic chamber. Each stimulus type was presented 169 times. This main sequence of SPLs was designed such, that each was offered 13 times and each SPL preceded each possible other. An additional initial sequence of SPLs, unrecognized by the subject, preceded the main sequence to allow for possible adaptation. Loudness judgments were made on a 1 to 50 scale, which was subdivided into five main loudness categories. Responses had to be given within a time window of four seconds. Depending on the individual CI user, loudness judgments varied in overall level and variance. In group statistics, judgments were strictly monotonic increasing with SPL, where each step of 5 dB was accompanied by a statistically significant increase in loudness judgment. Broad band stimuli were judged significantly louder than narrow band stimuli. A positive correlation of judgments both with the preceding SPL and the preceding judgment was found. In comparison to a reference group of 26 normal hearing listeners tested in the same setup in a preliminary work, the 26 CI users exhibited surprisingly similar results except for overall loudness level, especially in the lower SPL region. Generally, stimuli were judged significantly quieter than by normal hearing listeners. To produce the same loudness perception as in normal hearing listeners, approximately 5 dB higher SPLs would be necessary. The difference in loudness perception of the two groups can possibly be attributed to binaural loudness summation in normal hearing listeners as opposed to monaural hearing in the CI group. In the course of repeated mapping sessions and by adjusting their clinical processors, CI users have the option to decide about their CI system's loudness level. Assuming that binaural normal hearing establishes the optimal loudness perception, the question remains open, why CI users do not request loudness adjustment.

Page generated in 0.0888 seconds