• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 18
  • 18
  • 6
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo da frequência de Acanthamoeba e bactérias em biofilme e líquido de conservação de estojos de lentes de contato / Study of frequency of Acanthamoeba and bacteria in biofilm and liquid of contact lens case

Pens, Claiton José January 2008 (has links)
A popularização das lentes de contato possibilitou um aumento na incidência de infecções oculares causadas por diversos microrganismos. Os estojos de lentes de contato compartilham a microbiota do meio ambiente corporal e a ocular, podendo conter biofilmes. O presente trabalho objetivou avaliar a presença de bactérias e Acanthamoeba spp. no biofilme e líquido de conservação de lentes de contato. Oitenta e um voluntários requisitados no setor de oftalmologia do Hospital de Clínicas de Porto Alegre e no Campus Central da UFRGS, responderam um questionário com 17 perguntas e forneceram o estojo de lentes de contato. O material foi coletado entre julho de 2006 e fevereiro de 2007. As amostras foram inoculadas em duplicata em ágar sangue, para isolamento de bactérias e ágar não-nutriente 1,5% com uma sobrecamada de Escherichia coli, para isolamento de Acanthamoeba spp. Após o isolamento, obteve-se uma contagem bacteriana que variou de zero a 3x106 unidades formadoras de colônia (UFC/mL). Foram identificados 51 gêneros compostos por 10 espécies de bastonetes Gram-negativos, 11 espécies de bastonetes Gram-positivos, 11 de cocos Gram-positivos e. 19 espécies de cocobastonetes Gram positivos. Das 81 amostras analisadas, 7 (8,6%) foram positivas para Acanthamoeba spp. e o isolamento apresentou correlação com o maior número de UFC/mL. O gênero Acanthamoeba foi confirmado pela amplificação do DNA utilizando oligonucleotídeos iniciadores específicos para o gênero. Usuários de lentes de contato mais jovens, apresentaram maior contaminação em seus estojos. / The popularization of contact lenses allowed an increase in the incidence of eye infections caused by various microorganisms. The cases of contact lenses share the microbiota of the body and eye environment and may contain biofilms. This study aimed to evaluate the presence of bacteria and Acanthamoeba spp. in biofilm and preservative liquid of contact lenses. Eighty one volunteer requested in the division of ophthalmology of the Hospital de Clinicas in Porto Alegre and the Central Campus of the Federal University of Rio Grande do Sul, answered a questionnaire with 17 questions and provided the case of contact lenses. The material was collected between July 2006 and February 2007. The samples were inoculated in duplicate on blood agar, for isolation of bacteria and non-nutrient agar 1.5% with the addition of heat-killed Escherichia coli for isolation of Acanthamoeba spp. After isolation, the bacterial number ranged from zero to 3x106 colony forming units (CFU)/mL. Fifty one isolate of bacteria were identified including by 10 species of Gram-negative bacilli, 11 species of Gram-positive bacilli, 11 species of Gram-positive cocci and 19 species of Gram-positive coccobacilli. Of the 81 samples analyzed, 7 (8.6%) were positive for Acanthamoeba spp and the isolation slowed correlation with the largest number of CFU/mL. The genus Acanthamoeba was confirmed by DNA amplification using primers specific to the genus. Younger users of contact lenses presented greater contamination in its contact lens case.
12

Estudo da frequência de Acanthamoeba e bactérias em biofilme e líquido de conservação de estojos de lentes de contato / Study of frequency of Acanthamoeba and bacteria in biofilm and liquid of contact lens case

Pens, Claiton José January 2008 (has links)
A popularização das lentes de contato possibilitou um aumento na incidência de infecções oculares causadas por diversos microrganismos. Os estojos de lentes de contato compartilham a microbiota do meio ambiente corporal e a ocular, podendo conter biofilmes. O presente trabalho objetivou avaliar a presença de bactérias e Acanthamoeba spp. no biofilme e líquido de conservação de lentes de contato. Oitenta e um voluntários requisitados no setor de oftalmologia do Hospital de Clínicas de Porto Alegre e no Campus Central da UFRGS, responderam um questionário com 17 perguntas e forneceram o estojo de lentes de contato. O material foi coletado entre julho de 2006 e fevereiro de 2007. As amostras foram inoculadas em duplicata em ágar sangue, para isolamento de bactérias e ágar não-nutriente 1,5% com uma sobrecamada de Escherichia coli, para isolamento de Acanthamoeba spp. Após o isolamento, obteve-se uma contagem bacteriana que variou de zero a 3x106 unidades formadoras de colônia (UFC/mL). Foram identificados 51 gêneros compostos por 10 espécies de bastonetes Gram-negativos, 11 espécies de bastonetes Gram-positivos, 11 de cocos Gram-positivos e. 19 espécies de cocobastonetes Gram positivos. Das 81 amostras analisadas, 7 (8,6%) foram positivas para Acanthamoeba spp. e o isolamento apresentou correlação com o maior número de UFC/mL. O gênero Acanthamoeba foi confirmado pela amplificação do DNA utilizando oligonucleotídeos iniciadores específicos para o gênero. Usuários de lentes de contato mais jovens, apresentaram maior contaminação em seus estojos. / The popularization of contact lenses allowed an increase in the incidence of eye infections caused by various microorganisms. The cases of contact lenses share the microbiota of the body and eye environment and may contain biofilms. This study aimed to evaluate the presence of bacteria and Acanthamoeba spp. in biofilm and preservative liquid of contact lenses. Eighty one volunteer requested in the division of ophthalmology of the Hospital de Clinicas in Porto Alegre and the Central Campus of the Federal University of Rio Grande do Sul, answered a questionnaire with 17 questions and provided the case of contact lenses. The material was collected between July 2006 and February 2007. The samples were inoculated in duplicate on blood agar, for isolation of bacteria and non-nutrient agar 1.5% with the addition of heat-killed Escherichia coli for isolation of Acanthamoeba spp. After isolation, the bacterial number ranged from zero to 3x106 colony forming units (CFU)/mL. Fifty one isolate of bacteria were identified including by 10 species of Gram-negative bacilli, 11 species of Gram-positive bacilli, 11 species of Gram-positive cocci and 19 species of Gram-positive coccobacilli. Of the 81 samples analyzed, 7 (8.6%) were positive for Acanthamoeba spp and the isolation slowed correlation with the largest number of CFU/mL. The genus Acanthamoeba was confirmed by DNA amplification using primers specific to the genus. Younger users of contact lenses presented greater contamination in its contact lens case.
13

Efeito de diferentes tratamentos de superfície na resistência de união, ângulo de contato, morfologia e análise da distribuição de tensão de laminados ultrafinos de cerâmica reforçada por dissilicato de lítio /

Escobar, Lorena Cristina Bogado. January 2017 (has links)
Orientador: Maria Filomena Rocha Lima Huhtala / Banca: Alexandre Luiz Souto Borges / Banca: Marcelo Giannini / Resumo: Laminados cerâmicos são utilizados em tratamentos conservadores para restabelecer estética e função com mínimo desgaste da estrutura dental. O objetivo deste estudo foi avaliar, in vitro, o efeito de dois tratamentos de superfície em espécimes cerâmicos ultrafinos de dissilicato de lítio na resistência de união com o cimento resinoso. Laminas ultrafinas de cerâmica (14 X 12 X 0,3 mm) foram distribuídas aleatoriamente em dois grupos (n=20) de acordo com o tratamento de superfície: ácido hidrofluorídrico 5% durante 20 s e silano (HF) e Monobond Etch & Prime (Ivoclar, Vivadent) por 60 s (MEP). Dois cilindros de cimento resinoso foram confeccionados utilizando matrizes cilíndricas. Após 24 h de armazenamento, os espécimes foram submetidos ao ensaio mecânico de microcisalhamento (1 mm/min) e o modo de falha foi estabelecido. Dados de resistência de união foram analisados pelo teste t de Student (α=0.05). O ângulo de contato foi determinado. Análise morfológica das superfícies cerâmicas por meio de microscopia de força atômica e eletrônica de varredura foi realizada. Através de análise por elementos finitos foi estudada a distribuição de tensão em incisivos centrais superiores restaurados com laminados cerâmicos ultrafinos de dissilicato de lítio (0,3 mm). O modelo tridimensional foi elaborado no software Rhinoceros e exportado para software de análise Ansys. Foram modelados e analisados 04 grupos sob duas condições: desgaste ou não de esmalte e tipo de preparo. Foi aplicada uma ca... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Laminate veneers are becoming a technique used in the conservative treatments by the ability to restore aesthetics and function. This study aimed to evaluate, in vitro, the effect of two surface treatments on ultrathin lithium disilicate specimens in bond strength between treated ceramics and resin cement. Ceramic ultrathin laminates (12 X 14 X 0.3 mm) were obtained and randomly distributed into two groups (n=20) according to the surface treatment: 5% hydrofluoric acid for 20 s and silane (HF) and Monobond Etch & Prime (Ivoclar, Vivadent) for 60 s (MEP). Two resin cement cylinders were made using cylindrical matrices. After 24 h storage, microshear bond strength tests were performed in a universal testing machine (1 mm/min) and failure mode was analyzed. Bond strength data were submitted to Student's t-test (α=0.05). The contact angle was measured. Micromorphogical analyses of representatives specimens were also performed (atomic force and scanning electron microscopy). Finite element analysis studied the distribution of stress in maxillary central incisors restored with ultrathin laminate veneers of lithium disilicate (0.3 mm). 3D model was elaborated in CAD Rhinoceros® software and exported to analysis software Ansys®. Four groups were modeled and analyzed under two experimental conditions: wear or non-enamel and type of preparation. A load of 100 N was applied at the palatal face. The stress was analyzed by Maximum Principal Stress criteria. Microshear bond strength values... (Complete abstract click electronic access below) / Mestre
14

Estudo comparativo entre o telescópio com lente de contato e o telescópio convencional em pacientes com baixa visão / Comparative study between contact lens telescope and conventional telescope in lowvision patients

Bellini, Luciano Porto January 2009 (has links)
Objetivos: comparar o telescópio com lente de contato (TLC) com o telescópio convencional (TC) em pacientes com degeneração macular relacionada à idade (DMRI) e baixa visão, com respeito a: acuidade visual (AV), campo de visão (CV), satisfação do paciente com a visão oferecida pelo telescópio (SV), dificuldade de uso do telescópio (DU) e satisfação do paciente com o aspecto estético do telescópio (SE). Materiais e Métodos: Em ensaio clínico randomizado mascarado, foram incluídos 12 pacientes com DMRI e baixa visão, formando 2 grupos de 6 pacientes cada: grupo 1 (uso de TLC) e grupo 2 (uso de TC). Os telescópios usados no estudo foram padronizados para que tivessem a mesma magnificação (2,8x). A AV e o CV foram aferidos antes e durante o uso do telescópio, enquanto a SV, a DU e a SE foram obtidas após a intervenção. Resultados: Não houve diferenças entre os grupos na linha de base. Os dois telescópios demonstraram melhora da AV em relação à linha de base (P=0,002 com o TLC e P<0,001 com o TC) e não houve diferença entre os grupos a este respeito. O CV foi reduzido em 15° com o TLC (P<0.001) e em 54.3° com o TC (P<0.001), em comparação com a linha de base, e tais diferenças também foram significativas entre os grupos durante a intervenção (P<0.001). Os escores de SV foram semelhantes entre os grupos testados. Já os escores de SE, foram maiores com o TLC (P<0.001), assim como os de DU (P=0.003), em relação ao TC. Conclusões: Os dois telescópios promoveram melhora semelhante da AV em pacientes com DMRI e baixa visão, mas o TLC acarretou menor perda de CV em relação ao TC. A SE foi maior com o TLC, mas a DU também foi maior com o TLC, em relação ao TC. / Purpose: To compare the conventional telescope (CT) with the contact lens telescope (CLT) in patients with age-related macular degeneration (AMD) and low-vision, with respect to visual acuity (VA), visual field (VF), patient satisfaction with the vision provided by the telescope (VS), telescope use difficulties (UD) and patient satisfaction with the cosmetic appearance of the telescope (CS). Methods: In a masked randomized clinical trial, 12 patients with AMD and low-vision were enrolled in 2 groups with 6 patients each: group 1 (CLT use) and group 2. (CT use) The telescopes used in this study were standardized to have the same magnification power. (2.8x) Visual field and VA were obtained before and during the telescope use, while VS, UD and CS were obtained after the telescope use. Results: There were no significant differences between groups at baseline. Both groups achieved VA improvement with telescopes compared to baseline (P=0.002 in CLT group and P<0.001 in CT group) and there were no significant differences between groups in this regard. Visual field was reduced by 15° in CLT group (P<0.001) and by 54.3° in CT group (P<0.001) compared to baseline, and VF differences between groups were also significant during telescope use. (P<0.001) Scores observed in both groups were similar in regard to VS. Telescope use difficulties were significant higher in CLT group (P=0.003) as well as CS scores (P<0.001) compared to CT group. Conclusions: Both telescopes provide similar improvement in VA in AMD patients with low-vision, but CLT caused less VF reduction than CT use. Patient satisfaction with the cosmetic appearance of the telescope was higher in CLT group, but UD was also higher in this group compared to CT group.
15

Estudo comparativo entre o telescópio com lente de contato e o telescópio convencional em pacientes com baixa visão / Comparative study between contact lens telescope and conventional telescope in lowvision patients

Bellini, Luciano Porto January 2009 (has links)
Objetivos: comparar o telescópio com lente de contato (TLC) com o telescópio convencional (TC) em pacientes com degeneração macular relacionada à idade (DMRI) e baixa visão, com respeito a: acuidade visual (AV), campo de visão (CV), satisfação do paciente com a visão oferecida pelo telescópio (SV), dificuldade de uso do telescópio (DU) e satisfação do paciente com o aspecto estético do telescópio (SE). Materiais e Métodos: Em ensaio clínico randomizado mascarado, foram incluídos 12 pacientes com DMRI e baixa visão, formando 2 grupos de 6 pacientes cada: grupo 1 (uso de TLC) e grupo 2 (uso de TC). Os telescópios usados no estudo foram padronizados para que tivessem a mesma magnificação (2,8x). A AV e o CV foram aferidos antes e durante o uso do telescópio, enquanto a SV, a DU e a SE foram obtidas após a intervenção. Resultados: Não houve diferenças entre os grupos na linha de base. Os dois telescópios demonstraram melhora da AV em relação à linha de base (P=0,002 com o TLC e P<0,001 com o TC) e não houve diferença entre os grupos a este respeito. O CV foi reduzido em 15° com o TLC (P<0.001) e em 54.3° com o TC (P<0.001), em comparação com a linha de base, e tais diferenças também foram significativas entre os grupos durante a intervenção (P<0.001). Os escores de SV foram semelhantes entre os grupos testados. Já os escores de SE, foram maiores com o TLC (P<0.001), assim como os de DU (P=0.003), em relação ao TC. Conclusões: Os dois telescópios promoveram melhora semelhante da AV em pacientes com DMRI e baixa visão, mas o TLC acarretou menor perda de CV em relação ao TC. A SE foi maior com o TLC, mas a DU também foi maior com o TLC, em relação ao TC. / Purpose: To compare the conventional telescope (CT) with the contact lens telescope (CLT) in patients with age-related macular degeneration (AMD) and low-vision, with respect to visual acuity (VA), visual field (VF), patient satisfaction with the vision provided by the telescope (VS), telescope use difficulties (UD) and patient satisfaction with the cosmetic appearance of the telescope (CS). Methods: In a masked randomized clinical trial, 12 patients with AMD and low-vision were enrolled in 2 groups with 6 patients each: group 1 (CLT use) and group 2. (CT use) The telescopes used in this study were standardized to have the same magnification power. (2.8x) Visual field and VA were obtained before and during the telescope use, while VS, UD and CS were obtained after the telescope use. Results: There were no significant differences between groups at baseline. Both groups achieved VA improvement with telescopes compared to baseline (P=0.002 in CLT group and P<0.001 in CT group) and there were no significant differences between groups in this regard. Visual field was reduced by 15° in CLT group (P<0.001) and by 54.3° in CT group (P<0.001) compared to baseline, and VF differences between groups were also significant during telescope use. (P<0.001) Scores observed in both groups were similar in regard to VS. Telescope use difficulties were significant higher in CLT group (P=0.003) as well as CS scores (P<0.001) compared to CT group. Conclusions: Both telescopes provide similar improvement in VA in AMD patients with low-vision, but CLT caused less VF reduction than CT use. Patient satisfaction with the cosmetic appearance of the telescope was higher in CLT group, but UD was also higher in this group compared to CT group.
16

Estudo comparativo entre o telescópio com lente de contato e o telescópio convencional em pacientes com baixa visão / Comparative study between contact lens telescope and conventional telescope in lowvision patients

Bellini, Luciano Porto January 2009 (has links)
Objetivos: comparar o telescópio com lente de contato (TLC) com o telescópio convencional (TC) em pacientes com degeneração macular relacionada à idade (DMRI) e baixa visão, com respeito a: acuidade visual (AV), campo de visão (CV), satisfação do paciente com a visão oferecida pelo telescópio (SV), dificuldade de uso do telescópio (DU) e satisfação do paciente com o aspecto estético do telescópio (SE). Materiais e Métodos: Em ensaio clínico randomizado mascarado, foram incluídos 12 pacientes com DMRI e baixa visão, formando 2 grupos de 6 pacientes cada: grupo 1 (uso de TLC) e grupo 2 (uso de TC). Os telescópios usados no estudo foram padronizados para que tivessem a mesma magnificação (2,8x). A AV e o CV foram aferidos antes e durante o uso do telescópio, enquanto a SV, a DU e a SE foram obtidas após a intervenção. Resultados: Não houve diferenças entre os grupos na linha de base. Os dois telescópios demonstraram melhora da AV em relação à linha de base (P=0,002 com o TLC e P<0,001 com o TC) e não houve diferença entre os grupos a este respeito. O CV foi reduzido em 15° com o TLC (P<0.001) e em 54.3° com o TC (P<0.001), em comparação com a linha de base, e tais diferenças também foram significativas entre os grupos durante a intervenção (P<0.001). Os escores de SV foram semelhantes entre os grupos testados. Já os escores de SE, foram maiores com o TLC (P<0.001), assim como os de DU (P=0.003), em relação ao TC. Conclusões: Os dois telescópios promoveram melhora semelhante da AV em pacientes com DMRI e baixa visão, mas o TLC acarretou menor perda de CV em relação ao TC. A SE foi maior com o TLC, mas a DU também foi maior com o TLC, em relação ao TC. / Purpose: To compare the conventional telescope (CT) with the contact lens telescope (CLT) in patients with age-related macular degeneration (AMD) and low-vision, with respect to visual acuity (VA), visual field (VF), patient satisfaction with the vision provided by the telescope (VS), telescope use difficulties (UD) and patient satisfaction with the cosmetic appearance of the telescope (CS). Methods: In a masked randomized clinical trial, 12 patients with AMD and low-vision were enrolled in 2 groups with 6 patients each: group 1 (CLT use) and group 2. (CT use) The telescopes used in this study were standardized to have the same magnification power. (2.8x) Visual field and VA were obtained before and during the telescope use, while VS, UD and CS were obtained after the telescope use. Results: There were no significant differences between groups at baseline. Both groups achieved VA improvement with telescopes compared to baseline (P=0.002 in CLT group and P<0.001 in CT group) and there were no significant differences between groups in this regard. Visual field was reduced by 15° in CLT group (P<0.001) and by 54.3° in CT group (P<0.001) compared to baseline, and VF differences between groups were also significant during telescope use. (P<0.001) Scores observed in both groups were similar in regard to VS. Telescope use difficulties were significant higher in CLT group (P=0.003) as well as CS scores (P<0.001) compared to CT group. Conclusions: Both telescopes provide similar improvement in VA in AMD patients with low-vision, but CLT caused less VF reduction than CT use. Patient satisfaction with the cosmetic appearance of the telescope was higher in CLT group, but UD was also higher in this group compared to CT group.
17

"Desempenho visual na correção de miopia com óculos e lentes de contato gelatinosas" / Visual performance in myopic correction with spectacles and soft contact lenses

Andrade, Breno Barth Amaral de 24 September 2004 (has links)
Objetivos: Avaliar o desempenho visual(DV), por meio da AV logMAR de alto contraste, sensibilidade ao contaste(SC) e análise de frentes de onda(AFO), em míopes, com óculos e três LCG. Métodos: Estudo clínico e prospectivo, em 40 indivíduos míopes(-1,00D e -4,50D). Exames: AV logMAR de alto contraste, avaliação de SC e AFO. Resultados: A AFO detectou diferença na aberração de terceira ordem sem e com as LCG.. Em relação ao nível trifoil houve diferença entre com e sem LCG. Conclusões: Na avaliação do DV com óculos e com LCG, a AFO é uma medida mais sensível da função visual que a AV LogMAR de alto contraste e a SC. / Objective: to evaluate the visual performance(VP) by Visual acuity(VA)Logmar of high contrast, sensibility of contrast(SC) and wavefront (WF) in myopic patients correct with spectacles and 3 SCL Methods: prospective clinical trial was performed in 40 myopic patients(-1,00 D and -4,50 D). Exams: VA, WF and CS. Results: The WF analysis detected a significant difference in a third order aberration with and without SCL. There was significant difference related to trefoil coefficient in VP between with and without SCL. Conclusion: In VP evaluation with spectacles and SCL the wavefront analysis was more sensible measure of VP when compared with high contrast VA Logmar and CS.
18

"Desempenho visual na correção de miopia com óculos e lentes de contato gelatinosas" / Visual performance in myopic correction with spectacles and soft contact lenses

Breno Barth Amaral de Andrade 24 September 2004 (has links)
Objetivos: Avaliar o desempenho visual(DV), por meio da AV logMAR de alto contraste, sensibilidade ao contaste(SC) e análise de frentes de onda(AFO), em míopes, com óculos e três LCG. Métodos: Estudo clínico e prospectivo, em 40 indivíduos míopes(-1,00D e -4,50D). Exames: AV logMAR de alto contraste, avaliação de SC e AFO. Resultados: A AFO detectou diferença na aberração de terceira ordem sem e com as LCG.. Em relação ao nível trifoil houve diferença entre com e sem LCG. Conclusões: Na avaliação do DV com óculos e com LCG, a AFO é uma medida mais sensível da função visual que a AV LogMAR de alto contraste e a SC. / Objective: to evaluate the visual performance(VP) by Visual acuity(VA)Logmar of high contrast, sensibility of contrast(SC) and wavefront (WF) in myopic patients correct with spectacles and 3 SCL Methods: prospective clinical trial was performed in 40 myopic patients(-1,00 D and -4,50 D). Exams: VA, WF and CS. Results: The WF analysis detected a significant difference in a third order aberration with and without SCL. There was significant difference related to trefoil coefficient in VP between with and without SCL. Conclusion: In VP evaluation with spectacles and SCL the wavefront analysis was more sensible measure of VP when compared with high contrast VA Logmar and CS.

Page generated in 0.0994 seconds