• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Levantamento de seio maxilar com enxerto ósseo em neoformação associado a osso bovino inorgânico: avaliação clínica, histológica e histomorfométrica / Sinus lift with newly forming bone and inorganic bovine bone: a clinical, histologic and histomorphometric evaluation

Ferraz, Bruna Fidencio Rahal 13 August 2013 (has links)
O objetivo deste estudo é avaliar a efetividade do enxerto ósseo em neoformação (EONF) no ganho de altura de tecido ósseo em procedimentos de levantamento de seio maxilar. Foram selecionados indivíduos de ambos os sexos com idade entre 25 e 60 anos apresentando perda de um dente na região de pré-molares ou molares superiores com remanescente ósseo de 2 a 9 mm entre a crista do rebordo alveolar e o assoalho do seio maxilar e existência de rebordo desdentado ou pelo menos um dente condenado à extração. Os seios foram tratados por meio de EONF misturado a osso bovino inorgânico OBI (teste; n= 7) ou OBI (controle; n= 6). O volume de tecido ósseo existente foi avaliado por meio de tomografias computadorizadas obtidas no exame inicial e 6 meses após a cirurgia. Após este período, biópsias de tecido duro foram obtidas para análise histológica e histomorfométrica durante a cirurgia de instalação dos implantes osseointegrados. A análise dos resultados das imagens tomográficas por meio do teste t demonstrou que os dois materiais são igualmente efetivos no ganho em altura óssea (teste: 11,22 ± 0,60 mm vs. controle: 11,82 ± 0,69 mm; p= 0,0664). A análise histológica da reação tecidual ao redor e entre as partículas de enxerto mostrou ausência de diferenças estatisticamente significantes entre os grupos, segundo teste de Mann Whitney. A análise histomorfométrica demonstrou maior percentual de osso vital (31,42% ± 11,13% vs. 16,38% ± 10,14%; p= 0,0002), menor percentual de partículas remanescentes (1,32% ± 2,34% vs. 3,15% ± 3,31%; p= 0,0306) e de tecido conjuntivo (27,65% ± 12,34% vs. 35,02 ± 13,16; p= 0,0257) no grupo teste do que no controle. O diâmetro médio das partículas remanescentes foi maior no grupo controle do que no grupo teste, segundo teste t (p= 0,0294), embora não houvesse diferenças estatisticamente significantes entre os grupos em relação à área de contado direto entre o tecido ósseo neoformado e a superfície das partículas. Esses resultados sugerem que EONF é efetivo para o ganho de altura óssea em procedimentos de levantamento de seio maxilar, resultando em formação de maior quantidade de osso vital do que aquela observada com o uso de OBI apenas. / The aim of this study is to evaluate the efficacy of newly forming bone graft (NFB) in the gain of bone height in sinus lift procedures. It were recruited for this study individuals 25- 60 years of age, both genders, presenting a missing tooth at an upper premolar or molar region with 2-9 mm of remaining bone between alveolar ridge crest and sinus floor and the existence of an edentulous ridge or at least one tooth condemned to extraction. Sinus were treated by NFB mixed to inorganic bovine bone IBB (test; n= 7) or IBB (control; n= 6). The volume of bone tissue was evaluated by computerized tomography obtained at baseline examination and 6 months after surgery. After this period, biopsies of hard tissue were obtained during implant installation for histologic and histomorphometric analysis. The analysis of data from tomographic images by t test showed that both materials were equally effective in the gain of bone height (test: 11.22 ± 0.60 mm vs. control: 11.82 ± 0.69 mm; p= 0.0664). The histologic analysis of tissue reaction around and between graft particles showed absence of significant differences between groups, according to Mann Whitney. Histomorphometric analysis showed greater percentage of vital bone (31.42% ± 11.13% vs. 16.38% ± 10.14%; p= 0.0002) and lower percentage of remaining particles (1.32% ± 2.34% vs. 3.15% ± 3.31%; p= 0.0306) and connective tissue (27.65% ± 12.34% vs. 35.02 ± 13.16; p= 0.0257) at test than control group. The mean diameter of remaining particles was greater at control than test group, according to t test (p= 0.0294), although no differences were observed between groups related to the area of direct contact between new bone and particles surface. These findings suggest that NFB is effective in the gain of bone height in sinus lift procedures, resulting in the formation of greater amount of vital bone with the use of IBB alone.
2

Levantamento de seio maxilar com enxerto ósseo em neoformação associado a osso bovino inorgânico: avaliação clínica, histológica e histomorfométrica / Sinus lift with newly forming bone and inorganic bovine bone: a clinical, histologic and histomorphometric evaluation

Bruna Fidencio Rahal Ferraz 13 August 2013 (has links)
O objetivo deste estudo é avaliar a efetividade do enxerto ósseo em neoformação (EONF) no ganho de altura de tecido ósseo em procedimentos de levantamento de seio maxilar. Foram selecionados indivíduos de ambos os sexos com idade entre 25 e 60 anos apresentando perda de um dente na região de pré-molares ou molares superiores com remanescente ósseo de 2 a 9 mm entre a crista do rebordo alveolar e o assoalho do seio maxilar e existência de rebordo desdentado ou pelo menos um dente condenado à extração. Os seios foram tratados por meio de EONF misturado a osso bovino inorgânico OBI (teste; n= 7) ou OBI (controle; n= 6). O volume de tecido ósseo existente foi avaliado por meio de tomografias computadorizadas obtidas no exame inicial e 6 meses após a cirurgia. Após este período, biópsias de tecido duro foram obtidas para análise histológica e histomorfométrica durante a cirurgia de instalação dos implantes osseointegrados. A análise dos resultados das imagens tomográficas por meio do teste t demonstrou que os dois materiais são igualmente efetivos no ganho em altura óssea (teste: 11,22 ± 0,60 mm vs. controle: 11,82 ± 0,69 mm; p= 0,0664). A análise histológica da reação tecidual ao redor e entre as partículas de enxerto mostrou ausência de diferenças estatisticamente significantes entre os grupos, segundo teste de Mann Whitney. A análise histomorfométrica demonstrou maior percentual de osso vital (31,42% ± 11,13% vs. 16,38% ± 10,14%; p= 0,0002), menor percentual de partículas remanescentes (1,32% ± 2,34% vs. 3,15% ± 3,31%; p= 0,0306) e de tecido conjuntivo (27,65% ± 12,34% vs. 35,02 ± 13,16; p= 0,0257) no grupo teste do que no controle. O diâmetro médio das partículas remanescentes foi maior no grupo controle do que no grupo teste, segundo teste t (p= 0,0294), embora não houvesse diferenças estatisticamente significantes entre os grupos em relação à área de contado direto entre o tecido ósseo neoformado e a superfície das partículas. Esses resultados sugerem que EONF é efetivo para o ganho de altura óssea em procedimentos de levantamento de seio maxilar, resultando em formação de maior quantidade de osso vital do que aquela observada com o uso de OBI apenas. / The aim of this study is to evaluate the efficacy of newly forming bone graft (NFB) in the gain of bone height in sinus lift procedures. It were recruited for this study individuals 25- 60 years of age, both genders, presenting a missing tooth at an upper premolar or molar region with 2-9 mm of remaining bone between alveolar ridge crest and sinus floor and the existence of an edentulous ridge or at least one tooth condemned to extraction. Sinus were treated by NFB mixed to inorganic bovine bone IBB (test; n= 7) or IBB (control; n= 6). The volume of bone tissue was evaluated by computerized tomography obtained at baseline examination and 6 months after surgery. After this period, biopsies of hard tissue were obtained during implant installation for histologic and histomorphometric analysis. The analysis of data from tomographic images by t test showed that both materials were equally effective in the gain of bone height (test: 11.22 ± 0.60 mm vs. control: 11.82 ± 0.69 mm; p= 0.0664). The histologic analysis of tissue reaction around and between graft particles showed absence of significant differences between groups, according to Mann Whitney. Histomorphometric analysis showed greater percentage of vital bone (31.42% ± 11.13% vs. 16.38% ± 10.14%; p= 0.0002) and lower percentage of remaining particles (1.32% ± 2.34% vs. 3.15% ± 3.31%; p= 0.0306) and connective tissue (27.65% ± 12.34% vs. 35.02 ± 13.16; p= 0.0257) at test than control group. The mean diameter of remaining particles was greater at control than test group, according to t test (p= 0.0294), although no differences were observed between groups related to the area of direct contact between new bone and particles surface. These findings suggest that NFB is effective in the gain of bone height in sinus lift procedures, resulting in the formation of greater amount of vital bone with the use of IBB alone.
3

Análise da utilização do osteoscafTM como substituto ósseo em cirurgia de levantamento de seio maxilar / Use of OsteoScaf™ in maxillary sinus augmentation

Cardoso, Camila Lopes 04 March 2013 (has links)
Procedimentos de levantamento do seio maxilar têm sido realizados para aumentar o volume ósseo e promover a estabilidade do implante, na região posterior de maxilas severamente atrofiadas. Ao longo dos anos, resultados de vários estudos demonstraram que alguns substitutos ósseos podem suportar implantes em função, após o levantamento de seio maxilar, igual ou melhor quando utilizado o osso autógeno. Neste estudo, foi avaliado o comportamento de um substituto ósseo completamente biodegradável (OsteoScaf™) no modelo experimental de levantamento de seio maxilar em coelhos. Além disso, ele foi comparado com o osso autógeno e outros dois substitutos ósseos, não totalmente biodegradáveis, disponíveis comercialmente (Bio-Oss® e BoneCeramic®). Avaliação clínica, tomografia computadorizada por feixe cônico, microtomografia computadorizada, análises microscópicas e análise molecular, através da técnica de PCR, foram realizadas após 2, 4 e 8 semanas de cirurgia. O levantamento de seio maxilar utilizando o osso autógeno demonstrou maior reabsorção, ao longo do tempo, comparado aos substitutos ósseos, os quais revelaram maior neoformação óssea após 8, 4 e 2 semanas, respectivamente. O grupo Bio-Oss® apresentou maior neoformação óssea, ao longo do tempo, quando comparado aos grupos Osteoscaf™ e BoneCeramic®, os quais foram qualitativamente emelhantes. O grupo BoneCeramic® mostrou uma resposta celular de células gigantes até 8 semanas. Concluiu-se que os substitutos ósseos, neste estudo, obtiveram melhor desempenho do que o osso autógeno, e o OsteoScaf™ demonstrou maior reabsorção do que os outros grupos, em todos períodos. / Maxillary sinus augmentation procedures have been applied to increase bone volume and to promote stability of implants in the severely atrophied posterior maxilla. Over the years, the outcomes of several studies have demonstrated that some bone substitutes can support implants in function after sinus augmentation as well as, or better than those with autogenous bone. Our experimental model evaluated the behavior of a fully biodegradable bone substitute (OsteoScaf™) in a rabbit sinus lift procedure. We compared this with autogenous bone and other two available non-biodegradable bone substitutes (Bio-Oss® and BoneCeramic®). Clinical evaluation, Cone Beam Computed Tomography, Microcomputed Tomography, microscopic and molecular evaluation were used for data analysis at 2, 4 and 8 weeks after sinus augmentation. Autogenous bone was more resorbed over time than the other materials. All bone substitutes showed more bone formation at 8, 4 and 2 weeks, respectively. Bio-Oss® showed more bone formation/timepoint than Osteoscaf™ and Boneceramic®, which were similar. Boneceramic® showed a florid giant cell response up to 8 weeks. We concluded that the bone graft materials all performed better than autogenous bone and OsteoScaf™ showed comparative bone growth yet greater degradation than the other two materials.
4

Análise da utilização do osteoscafTM como substituto ósseo em cirurgia de levantamento de seio maxilar / Use of OsteoScaf™ in maxillary sinus augmentation

Camila Lopes Cardoso 04 March 2013 (has links)
Procedimentos de levantamento do seio maxilar têm sido realizados para aumentar o volume ósseo e promover a estabilidade do implante, na região posterior de maxilas severamente atrofiadas. Ao longo dos anos, resultados de vários estudos demonstraram que alguns substitutos ósseos podem suportar implantes em função, após o levantamento de seio maxilar, igual ou melhor quando utilizado o osso autógeno. Neste estudo, foi avaliado o comportamento de um substituto ósseo completamente biodegradável (OsteoScaf™) no modelo experimental de levantamento de seio maxilar em coelhos. Além disso, ele foi comparado com o osso autógeno e outros dois substitutos ósseos, não totalmente biodegradáveis, disponíveis comercialmente (Bio-Oss® e BoneCeramic®). Avaliação clínica, tomografia computadorizada por feixe cônico, microtomografia computadorizada, análises microscópicas e análise molecular, através da técnica de PCR, foram realizadas após 2, 4 e 8 semanas de cirurgia. O levantamento de seio maxilar utilizando o osso autógeno demonstrou maior reabsorção, ao longo do tempo, comparado aos substitutos ósseos, os quais revelaram maior neoformação óssea após 8, 4 e 2 semanas, respectivamente. O grupo Bio-Oss® apresentou maior neoformação óssea, ao longo do tempo, quando comparado aos grupos Osteoscaf™ e BoneCeramic®, os quais foram qualitativamente emelhantes. O grupo BoneCeramic® mostrou uma resposta celular de células gigantes até 8 semanas. Concluiu-se que os substitutos ósseos, neste estudo, obtiveram melhor desempenho do que o osso autógeno, e o OsteoScaf™ demonstrou maior reabsorção do que os outros grupos, em todos períodos. / Maxillary sinus augmentation procedures have been applied to increase bone volume and to promote stability of implants in the severely atrophied posterior maxilla. Over the years, the outcomes of several studies have demonstrated that some bone substitutes can support implants in function after sinus augmentation as well as, or better than those with autogenous bone. Our experimental model evaluated the behavior of a fully biodegradable bone substitute (OsteoScaf™) in a rabbit sinus lift procedure. We compared this with autogenous bone and other two available non-biodegradable bone substitutes (Bio-Oss® and BoneCeramic®). Clinical evaluation, Cone Beam Computed Tomography, Microcomputed Tomography, microscopic and molecular evaluation were used for data analysis at 2, 4 and 8 weeks after sinus augmentation. Autogenous bone was more resorbed over time than the other materials. All bone substitutes showed more bone formation at 8, 4 and 2 weeks, respectively. Bio-Oss® showed more bone formation/timepoint than Osteoscaf™ and Boneceramic®, which were similar. Boneceramic® showed a florid giant cell response up to 8 weeks. We concluded that the bone graft materials all performed better than autogenous bone and OsteoScaf™ showed comparative bone growth yet greater degradation than the other two materials.

Page generated in 0.1274 seconds