• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise estrutural de vigas mistas de aço e concreto em perfis formados a frio: estudo da ligação viga-pilar e da região de momento negativo / Cold-formed steel and concrete composite beams: study of beam-to-column connection and region of hogging bending

Mairal, Raphael 14 September 2010 (has links)
No Brasil, o emprego de estruturas de aço constituídas por perfis formados a frio tem crescido consideravelmente, em virtude da ampla disponibilidade de laminados planos no mercado (chapas finas), bem como pela busca de soluções estruturais mais competitivas. Nesse cenário, pode-se destacar as estruturas mistas de aço e concreto destinadas aos edifícios habitacionais de pequeno porte, em que os tradicionais perfis laminados são substituídos por perfis formados a frio tanto nas vigas como nos pilares. Embora o sistema de vigas mistas possa ser considerado consolidado no campo dos perfis laminados e soldados, o comportamento estrutural no caso de perfis formados a frio necessita de investigação mais aprofundada, de modo a verificar os modos de ruína e a viabilidade do emprego dos modelos teóricos clássicos. Nesse trabalho foi desenvolvido um estudo teórico e experimental sobre as vigas mistas em perfis formados a frio duplo U enrijecido, focalizando a ligação mista (ligação viga-pilar) e consequentemente a resposta estrutural da região de momento fletor negativo. O programa experimental consistiu da análise de dois protótipos cruciformes para determinar a curva momento-rotação, o momento resistente, a rigidez, a capacidade de rotação e identificar modos de falha. Foi possível constatar maior capacidade de rotação da ligação com cantoneiras de assento e de alma quando comparada a uma ligação totalmente soldada. Comparando com o modelo experimental o método dos componentes avaliou de forma razoável a rigidez em serviço, já o método proposto por Leon et. al. superestimou muito esse parâmetro, a capacidade de rotação foi avaliada de forma satisfatória pelos dois métodos. O momento resistente negativo da viga mista obtido experimentalmente apresentou um valor intermediário entre os valores teóricos obtidos por processo plástico e elástico. / In Brazil, the cold-formed steel structures have been widely used justified by the large availability of steel sheets in the market (thin sheets) and the search for more competitive structural solutions. Thus as steel and concrete composite structures are applied in small constructions the traditional hot-rolled one is replaced by cold-formed members in the beams and columns. Even though the composite beams system is known in the hot-rolled and welded shapes field, the structural behavior of the cold-formed steel still needs more accurate investigation to verify the failure modes and the viability of the classic theoretical models. In this work a theoretical and experimental study about cold-formed steel and concrete composite beams was developed, focusing on the beam-to-column connection and the structural behavior on the region of hogging bending. For the experimental program two cruciform models of beam-column connections were analyzed to obtain the moment-rotation curves, the stiffness, and the rotation capacity. It was possible to verify the largest rotation capacity of the connection with the steel seat and web angle when compared with the totally welded connection. In the case of connection the method of the components estimates well the secant stiffness and the rotation capacity presenting a value closer to the ones obtained experimentally, Leon et al. procedures estimated well the initial stiffness and the rotation capacity, but the value of the secant stiffness is much larger than the experimental one. In the case of composite beam the ultimate strength (Mmax) experimentally obtained presented an intermediate value to the ones obtained by the plastic and elastic method.
2

Análise estrutural de vigas mistas de aço e concreto em perfis formados a frio: estudo da ligação viga-pilar e da região de momento negativo / Cold-formed steel and concrete composite beams: study of beam-to-column connection and region of hogging bending

Raphael Mairal 14 September 2010 (has links)
No Brasil, o emprego de estruturas de aço constituídas por perfis formados a frio tem crescido consideravelmente, em virtude da ampla disponibilidade de laminados planos no mercado (chapas finas), bem como pela busca de soluções estruturais mais competitivas. Nesse cenário, pode-se destacar as estruturas mistas de aço e concreto destinadas aos edifícios habitacionais de pequeno porte, em que os tradicionais perfis laminados são substituídos por perfis formados a frio tanto nas vigas como nos pilares. Embora o sistema de vigas mistas possa ser considerado consolidado no campo dos perfis laminados e soldados, o comportamento estrutural no caso de perfis formados a frio necessita de investigação mais aprofundada, de modo a verificar os modos de ruína e a viabilidade do emprego dos modelos teóricos clássicos. Nesse trabalho foi desenvolvido um estudo teórico e experimental sobre as vigas mistas em perfis formados a frio duplo U enrijecido, focalizando a ligação mista (ligação viga-pilar) e consequentemente a resposta estrutural da região de momento fletor negativo. O programa experimental consistiu da análise de dois protótipos cruciformes para determinar a curva momento-rotação, o momento resistente, a rigidez, a capacidade de rotação e identificar modos de falha. Foi possível constatar maior capacidade de rotação da ligação com cantoneiras de assento e de alma quando comparada a uma ligação totalmente soldada. Comparando com o modelo experimental o método dos componentes avaliou de forma razoável a rigidez em serviço, já o método proposto por Leon et. al. superestimou muito esse parâmetro, a capacidade de rotação foi avaliada de forma satisfatória pelos dois métodos. O momento resistente negativo da viga mista obtido experimentalmente apresentou um valor intermediário entre os valores teóricos obtidos por processo plástico e elástico. / In Brazil, the cold-formed steel structures have been widely used justified by the large availability of steel sheets in the market (thin sheets) and the search for more competitive structural solutions. Thus as steel and concrete composite structures are applied in small constructions the traditional hot-rolled one is replaced by cold-formed members in the beams and columns. Even though the composite beams system is known in the hot-rolled and welded shapes field, the structural behavior of the cold-formed steel still needs more accurate investigation to verify the failure modes and the viability of the classic theoretical models. In this work a theoretical and experimental study about cold-formed steel and concrete composite beams was developed, focusing on the beam-to-column connection and the structural behavior on the region of hogging bending. For the experimental program two cruciform models of beam-column connections were analyzed to obtain the moment-rotation curves, the stiffness, and the rotation capacity. It was possible to verify the largest rotation capacity of the connection with the steel seat and web angle when compared with the totally welded connection. In the case of connection the method of the components estimates well the secant stiffness and the rotation capacity presenting a value closer to the ones obtained experimentally, Leon et al. procedures estimated well the initial stiffness and the rotation capacity, but the value of the secant stiffness is much larger than the experimental one. In the case of composite beam the ultimate strength (Mmax) experimentally obtained presented an intermediate value to the ones obtained by the plastic and elastic method.
3

Estudo experimental de uma ligação viga-pilar em concreto pré-moldado utilizando perfis metálicos e solda / Experimental study of a precast concrete beam-column connection using welded steel shapes

Trotta, André Marcon 03 September 2012 (has links)
Nesta pesquisa estudou-se o comportamento de uma ligação viga-pilar em concreto pré-moldado utilizando perfis metálicos embutidos nos elementos estruturais. O modelo da ligação estudada permite a transmissão de momentos fletores positivo e negativo. Para a continuidade de momento fletor negativo, utilizam-se um consolo metálico com seção \"U\" embutido no pilar e dentes metálicos com seção tubular retangular embutidos nas vigas, soldados. Para a continuidade de momento positivo, utilizam-se cantoneiras metálicas embutidas no pilar que são soldadas à armadura positiva da viga. O estudo consistiu em análise experimental de um modelo cruciforme em duas etapas. Na primeira etapa o modelo foi solicitado a carregamentos cíclicos reversíveis por meio de um atuador servo hidráulico acoplado sobre o topo do pilar. Na segunda etapa, o modelo foi solicitado a carregamento estático monotônico por meio de macacos hidráulicos dispostos sob o pilar para causar a ruptura com momento negativo. O modelo apresentou uma considerável facilidade de montagem, já que na fase transitória a ligação é articulada e o consolo do pilar em perfil \"U\" permite a estabilidade lateral da viga. O consolo metálico embutido no pilar escoou muito antes de atingir a capacidade resistente dos outros componentes da ligação, pois na seção da ligação junto à face do pilar, apenas o consolo resiste à flexão. / In this research the behavior of a beam-column connection in precast concrete system using welded steel shapes built-in structural elements was studied. The model of the studied connection allows transmission of positive and negative moments. For the continuity of negative moment, is used a steel \"U\" shaped corbel inserted in the column welded with tubular section steel hangers inserted in each beam. For the continuity of positive moment, use is made of metal embedded in abutment ledges that are welded to the positive reinforcement of the beam. The study consisted on experimental analysis of a cross-shaped specimen in two steps. In the first step was applied to the specimen a cyclic load using hydraulic actuator coupled to the column head. In the second step was applied in the specimen a static load using hydraulic jack positioned under the column to cause rupture with negative moment. The connection model showed a considerably easy assembly, as in the transitional phase the connection is articulated and the steel \"U\" shaped corbel of the column allows the lateral stability of the beam. The rupture occurred by yielding of the steel U shaped corbel in the section near the column. The steel corbel inserted in the column yielded before reaches the resistant capacity of other components of the connection, because of the section in the connection close of the column, only steel corbel resists the negative moment.
4

Estudo experimental de uma ligação viga-pilar em concreto pré-moldado utilizando perfis metálicos e solda / Experimental study of a precast concrete beam-column connection using welded steel shapes

André Marcon Trotta 03 September 2012 (has links)
Nesta pesquisa estudou-se o comportamento de uma ligação viga-pilar em concreto pré-moldado utilizando perfis metálicos embutidos nos elementos estruturais. O modelo da ligação estudada permite a transmissão de momentos fletores positivo e negativo. Para a continuidade de momento fletor negativo, utilizam-se um consolo metálico com seção \"U\" embutido no pilar e dentes metálicos com seção tubular retangular embutidos nas vigas, soldados. Para a continuidade de momento positivo, utilizam-se cantoneiras metálicas embutidas no pilar que são soldadas à armadura positiva da viga. O estudo consistiu em análise experimental de um modelo cruciforme em duas etapas. Na primeira etapa o modelo foi solicitado a carregamentos cíclicos reversíveis por meio de um atuador servo hidráulico acoplado sobre o topo do pilar. Na segunda etapa, o modelo foi solicitado a carregamento estático monotônico por meio de macacos hidráulicos dispostos sob o pilar para causar a ruptura com momento negativo. O modelo apresentou uma considerável facilidade de montagem, já que na fase transitória a ligação é articulada e o consolo do pilar em perfil \"U\" permite a estabilidade lateral da viga. O consolo metálico embutido no pilar escoou muito antes de atingir a capacidade resistente dos outros componentes da ligação, pois na seção da ligação junto à face do pilar, apenas o consolo resiste à flexão. / In this research the behavior of a beam-column connection in precast concrete system using welded steel shapes built-in structural elements was studied. The model of the studied connection allows transmission of positive and negative moments. For the continuity of negative moment, is used a steel \"U\" shaped corbel inserted in the column welded with tubular section steel hangers inserted in each beam. For the continuity of positive moment, use is made of metal embedded in abutment ledges that are welded to the positive reinforcement of the beam. The study consisted on experimental analysis of a cross-shaped specimen in two steps. In the first step was applied to the specimen a cyclic load using hydraulic actuator coupled to the column head. In the second step was applied in the specimen a static load using hydraulic jack positioned under the column to cause rupture with negative moment. The connection model showed a considerably easy assembly, as in the transitional phase the connection is articulated and the steel \"U\" shaped corbel of the column allows the lateral stability of the beam. The rupture occurred by yielding of the steel U shaped corbel in the section near the column. The steel corbel inserted in the column yielded before reaches the resistant capacity of other components of the connection, because of the section in the connection close of the column, only steel corbel resists the negative moment.

Page generated in 0.1207 seconds