• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • Tagged with
  • 12
  • 12
  • 12
  • 8
  • 8
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo anatômico, radiográfico e biomecânico dos estabilizadores mediais da patela: ligamento patelofemoral  medial, ligamento patelotibial medial e ligamento patelomeniscal medial / Anatomic, radiographic and biomechanical study of the medial patellar stabilizers: medial patellofemoral ligament, medial patellotibial ligament and medial patellomeniscal ligament

Betina Bremer Hinckel 26 July 2016 (has links)
INTRODUÇÃO: Os ligamentos mediais responsáveis pela manutenção da estabilidade da articulação patelofemoral (PF) são o ligamento patelofemoral medial (LPFM), o ligamento patelotibial medial (LPTM) e o ligamento patelomeniscal medial (LPMM). Sobre o LPFM, existem vários estudos anatômicos, radiológicos, biomecânicos, e a evolução clínica de sua lesão e reconstrução; no entanto, pouco se sabe sobre o LPTM e o LPMM. MÉTODOS: O LPFM, o LPTM e o LPMM foram dissecados em 9 joelhos. Todos os ligamentos foram enviados para avaliação histológica, corados pelo método de hematoxilina e eosina (HE), após o teste biomecânico. Foram medidos o comprimento e a largura bem como a relação das inserções com referências anatômicas (epicôndilo medial do fêmur, tubérculo dos adutores no fêmur, linha articular, tendão patelar e menisco medial). Esferas metálicas foram introduzidas nas inserções e radiografias em ântero-posterior (AP) e perfil (P) realizadas. Foram medidas as distâncias entre as inserções e as linhas de base (na tíbia, linha do planalto, borda medial do planalto e borda medial da espinha medial; e na patela, linha da cortical posterior e bordas proximal e distal da patela). Os ensaios de tração dos ligamentos foram executados em uma máquina de ensaios mecânicos KRATOS. RESULTADOS: Todos os materiais apresentaram tecido conjuntivo denso característico de tecido ligamentar. Com o estudo anatômico verificamos que o LPFM se encontrou na camada 2, com comprimento de 60.6 mm e largura de 15,3 mm no fêmur e 20,7 mm na patela. Inseriu-se entre o tubérculo dos adutores e o epicôndilo medial no fêmur e no pólo proximal da patela. O LPTM tinha um comprimento de 36,4 mm e largura de 7,1 mm. Sua inserção tibial se encontrou 13,7 mm distal a articulação e 11,6 mm medial ao tendão patelar formando um ângulo de 18,5o com este. A inserção na patela foi 3,6 mm proximal a sua borda distal. O LPMM se encontrou na camada 3 e seu comprimento foi de 33,7 mm e largura de 8,3 mm. Com uma inserção meniscal no corno anterior, 26,6 mm medial ao tendão patelar e formando ângulo com tendão patelar de 42,8o. Sobre os parâmetros radiográficos, a inserção tibial do LPTM se encontrou 9,4 mm, na incidência AP, e 13,5 mm, na incidência P, distal a articulação. Quanto ao posicionamento médio lateral a inserção se encontrou a 30% do comprimento do planalto de medial para lateral e na borda medial da espinha medial. A inserção patelar era 4,8 mm proximal a sua borda distal. Na análise biomecânica verificamos que o LPTM era mais rígido que o LPFM (médias de 17,0 N/mm versus 8,0 N/mm, respectivamente) e apresentou menor deformação no limite de resistência máxima (8,6 mm Resumo Betina Bremer Hinckel versus 19,3 mm). CONCLUSÃO: Os ligamentos foram identificados em todos os joelhos. Os parâmetros anatômicos e radiográficos das inserções foram bem definidos. Os enxertos comumente utilizados para as reconstruções ligamentares do joelho são suficientes para a reconstrução do LPFM e do LPTM / INTRODUCTION: The medial ligaments responsible for maintaining the stability of the patellofemoral (PF) joint are the medial patellofemoral ligament (MPFL), the medial patellotibial ligament (MPTL) and the medial patellomeniscal ligament (MPML). There are several studies on the anatomical, imaging, and biomechanical characteristics of the MPFL, and clinical outcome of its injury and reconstruction; however, little is known about the MPTL and MPML. METHODS: The MPFL, MPTL and MPML were dissected in 9 knees. All ligaments underwent histological evaluation by hematoxylin eosin stain after the biomechanical test. The length and width and the insertions relationship with anatomical references (medial epicondyle of the femur, adductor tubercle of the femur, joint line, patellar tendon and medial meniscus) were measured. Steel balls were introduced at the insertions and radiographs in anteroposterior (AP) and profile (P) views were performed. The distance between the insertions to baselines were measured (in the tibia, the plateau line, the medial plateau border and the medial border of the medial tibial spine; and in the patella the posterior cortical line and the proximal and distal patellar borders). The tensile tests of the ligaments were performed on a mechanical testing machine KRATOS. RESULTS: All materials showed dense connective tissue characteristic of ligaments. With the anatomical study we found that the MPFL was in layer 2, it has length of 60.6 mm and width of 15,3 mm in the femur and 20,7 mm in the patella. Inserting between the adductor tubercle and the medial epicondyle on the femur and in the inferior pole of the patella. The MPTL was found in layer 2, its length was 36.4 mm and width of 7.1 mm. Its tibial insertion was found 13.7 mm distal to the joint line and 11.6 mm medial to the patellar tendon at an angle of 18,5o with it. On the patella it was 3.6 mm proximal to its distal border. The MPML was in layer 3 and its length was 33.7 mm and width of 8.3 mm. The meniscal insertion was in the anterior horn, 26.6 mm medial to the patellar tendon and a 42,8o angle with it. In regards to the radiographic parameters the tibial insertion of LPTM was 9.4 mm, in the AP, and 13.5 mm, in the P, distal to the joint line. The medial lateral position was at 30% from medial to lateral on the tibial plateau and on the medial edge of the medial spine. The patellar insertion was 4.8 mm proximal to the distal border of the patella. In the biomechanical analysis we verified that the MPTL was more rigid then the MPFL (average of 17.0 N / mm versus 8.0 N / mm, respectively) and showed less deformation in the maximum tensile strength (8,6 mm versus 19,3 mm). CONCLUSION: The ligaments were identified in all knees. The anatomical and radiographic insertion parameters were well
12

O ligamento anterolateral do joelho: estudo anatômico, histológico e por ressonância magnética / The knee anterolateral ligament: an anatomical, histological and magnetic resonance imaging study

Camilo Partezani Helito 17 July 2017 (has links)
O ligamento cruzado anterior é o ligamento mais lesado dentre os ligamentos do joelho. Apesar de um aprimoramento das técnicas de reconstrução, existe ainda um porcentual de pacientes que apresenta resultado funcional insatisfatório. Possivelmente a causa dessa instabilidade rotatória estaria nas estruturas localizadas na porção anterolateral do joelho, não reconstruídas nas reconstruções intra-articulares isoladas. Uma dessas estruturas seria o ligamento anterolateral, estrutura estudada com detalhes nos últimos anos, ainda com controvérsias em relação a seus parâmetros anatômicos, histológicos e de visualização por ressonância magnética. Neste estudo, foram realizadas dissecções de 112 cadáveres para avaliação dos parâmetros anatômicos e histológicos do ligamento anterolateral, sendo que 13 deles foram submetidos ao exame de ressonância magnética previamente às dissecções. O estudo do ligamento anterolateral por ressonância magnética foi realizado também em 42 pacientes. Como resultados, o ligamento anterolateral foi encontrado com constância na região anterolateral do joelho, com origem próxima ao epicôndilo lateral, trajeto anterodistal em direção à tíbia e inserção na periferia do menisco lateral e na região anterolateral da tíbia, entre o tubérculo de Gerdy e a cabeça da fíbula. Sua análise histológica mostrou a presença de tecido conectivo denso e bem organizado, semelhante a tecido ligamentar. A avaliação por ressonância magnética mostrou parâmetros de origem, inserção e trajeto semelhantes às dissecções anatômicas, embora não sendo possível a visualização completa dessa estrutura em todos os exames. Existiu correlação entre as medidas encontradas nos exames de ressonância magnética e nas dissecções, exceto em relação à espessura do ligamento anterolateral / The anterior cruciate ligament is the most injured ligament of the knee. Despite an improvement in reconstruction techniques, there is still a percentage of patients with poor functional outcome after its reconstruction. Possibly, the cause of this rotational instability would be the structures located in the anterolateral portion of the knee, not addressed in the isolated intra-articular reconstructions. One of such structures would be the anterolateral ligament, a structure studied in detail in recent years, with controversies regarding its anatomical, histological and magnetic resonance imaging parameters. In this study, dissections of 112 cadavers were performed to evaluate anatomical and histological parameters of anterolateral ligament, and 13 of them underwent magnetic resonance imaging examination prior to dissection. The anterolateral ligament study by magnetic resonance imaging was also performed in 42 patients. As a result, the anterolateral ligament was found with constancy in the anterolateral region of the knee, with origin near the lateral epicondyle, antero-distal path towards the tibia and insertion in the periphery of the lateral meniscus and in the anterolateral region of the proximal tibia, between Gerdy\'s tubercle and the fibular head. Its histological analysis showed the presence of dense and well-organized connective tissue, similar to a ligamentous tissue. The magnetic resonance imaging evaluation showed origin, insertion and path parameters similar to the anatomical dissections, although it is not possible to fully visualize this structure in all the magnetic resonance imaging exams. There was a correlation between the measurements found in magnetic resonance imaging scans and dissections, except in relation to the anterolateral ligament thickness

Page generated in 0.1033 seconds