• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • 9
  • 9
  • 9
  • 9
  • 8
  • 2
  • 1
  • 1
  • Tagged with
  • 32
  • 32
  • 23
  • 19
  • 16
  • 16
  • 13
  • 13
  • 11
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência do tratamento de superfície do metal na resistência de união entre uma liga de cobalto-cromo e duas cerâmicas /

Lombardo, Geraldo Henrique Leão. January 2007 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Leonardo Buso / Banca: José Henrique Rubo / Resumo: Este trabalho avaliou a influência do tratamento superficial do metal (jateamento com óxido de alumínio e ponta de tungstênio), na resistência ao cisalhamento, entre uma liga de Co-Cr (StarLoy C - DeguDent) e duas cerâmicas (StarLight Ceram - DegunDent e Duceram Kiss - Degudent). Foram confeccionados quarenta e oito padrões metálicos de formato cilíndrico, com altura total de 4,7 mm, tendo diâmetro diferenciado entre as extremidades; a maior com 5 mm e a menor com 3,7 mm (ISO 11405), sendo doze para cada grupo: G1- superfície metálica jateada com óxido de alumínio + StarLight Ceram; G2- superfície metálica tratada com ponta de tungstênio + StarLight Ceram; G3- superfície metálica jateada com óxido de alumínio + Duceram Kiss e G4- superfície metálica tratada com ponta de tungstênio + Duceram Kiss. O ensaio de cisalhamento foi realizado em máquina de ensaio universal (Emic DL 1000, São José dos Pinhais, Brasil), com célula de carga de 100 Kg, à velocidade de 0,5 mm/min, utilizando um dispositivo específico (faca com entalhe). Após o ensaio, foi realizada a análise fractográfia e os dados obtidos analisados estatisticamente pelo teste ANOVA (2 fatores). Foram observados os seguintes valores médios de resistência de união: G1 (57,97l11,34 MPa); G2 (40,62l12,96 MPa); G3 (47,09l13,19 MPa) e G4 (36,80l8,86 MPa). Concluiu-se que o tratamento superficial com óxido de alumínio, aumentou a resistência de união entre metal e cerâmica, independente do tipo de cerâmica utilizada. / Abstract: The aim of this study was to evaluate the influence of the surface treatment (sandblasting with aluminium oxide and tungsten carbide bur), on the shear bond strength among a Co-Cr alloy (StarLoy C - DeguDent) and two ceramics (StarLight Ceram - DeguDent and Duceram Kiss - Degudent). Forty eigth metal cilindric specimens were made with 4,7 mm high, with two different diameters: one with 5,5 mm and the other with 3,7 mm (ISO 11405), with twelve specimens for each one of the four groups: G1 - sandblasting + StarLigth Ceram; G2 - tungsten carbide burs + StarLigth Ceram; G3 - sandblasting + Duceram Kiss and G4 - tungsten carbide burs + Duceram Kiss. The shear test was made with a universal testing machine (Emic DL 1000, São José dos Pinhais, Brazil), with load of 100 kg, with the crosshead speed of 0,5 mm/min, using a specific device (knife with an indent - Ultradent). The fracture analysis of the surfaces was made and the data were statistically analyzed with the ANOVA (two way). The means and the standard deviations of the shear bond strength were: G1 (57,97l11,34 MPa); G2 (40,62l12,9 MPa); G3 (47,09l13,19 MPa) e G4 (36,80l8,86 MPa). It could be concluded that the surface treatment with the tungsten carbide bur reduced the shear bond strength, independent of the ceramics used. / Mestre
2

Discrepâncias de assentamento ocorrido em coroas totais metálicas, com e sem alívio interno, variando-se os términos cervicais e os agentes cimentantes /

Figueiredo, Aldari Raimundo January 1997 (has links)
Orientador: Marco Antonio Bottino / Banca: Pedro Tortamano Neto / Banca: Orlando Magalhães Filho / Banca: José Eduardo Junho de Araujo / Banca: Ruy Fonseca Brunetti / Resumo: Foi feita uma análise das discrepâncias de assentamento ocorridas na cimentação de coroas totais metálicas aliviadas ou não, internamente, sobre preparos com término cervical em chanfro; linha zero ou lâmina de faca; plano inclinado em 135°; ombro reto ou degrau em 90° e ombro reto ou degrau em 90°, associado a um bisel em 45°. Empregaram-se quatro tipos de cimentos, sendo três classificados como temporários à base de óxido de zinco e eugenol (Temp Bond e Provy) e outro sem eugenol (Temp Bond NE); e um quarto indicado para cimentações definitivas, cimento de Fosfato de Zinco. Idealizou-se modelos-padrão usinados em aço inoxidável, com características de um preparo para coroa total metálica em um primeiro molar inferior variando-se os términos cervicais conforme estabelecido. Foram obtidas cápsulas metálicas usinadas em aço inoxidável e perfeitamente adaptadas aos modelos-padrão com os términos cervicais correspondentes, nas condições de estarem aliviadas internamente ou não. Empregou-se uma técnica de cimentação padronizada para assentamento destas cápsulas metálicas nos modelos-padrão respectivos. Através de metodologia original promoveu-se a mensuração da discrepância de assentamento nos corpos-de-prova, com o aparelho Metroscópio Horizontal. Concluiu-se que: a) o alívio executado nas superfícies internas das coroas diminui de forma estatisticamente significante a discrepância marginal após a cimentação, independentemente do tipo de cimento empregado e da forma do término cervical adotada; b) o término cervical do preparo no modelo-padrão tipo Lâmina de Faca foi o que apresentou menor discrepância, independente do cimento empregado, seguido pelo Plano Inclinado, Chanfro, Ombro Biselado e Ombro Reto; c) os términos cervicais em Chanfro, Plano Inclinado e Lâmina de Faca, quando analisadas as amostras dos corpos-de-prova com alívio, .... / Abstract: Seating discrepancies during cementation of complete metal crowns internally relieved or not with various finishing lines and cementing agents. This study evaluated the discrepancies during cementation of complete metal crowns either relieved or not on preparation with various margin designs: chamfer, knife edge, 135 degree shoulder, 90 degree shoulder, 90 degree shoulder with 45 degree bevel. Four types of cements, three temporary and one definitive were used: 1- zinc oxide and eugenol temporary cement (Temp Bond); 2- zinc oxide and eugenol temporary cement (Provy); 3- no eugenol temporary cement (Temp Bond NE) and 4- zinc phosphate cement (S.S.White). Machined stainless dies were fabricated to resemble complete crown preparations for a lower first molar with various finishing lines. Machined stainless steel copings, either internally relieved or not were also fabricated to fit the metal dies. A controlled technique was developed to assess seating discrepancies under the horizontal metroscope. Results showed: a) the internally relieved crowns showed after cementation statistically significant reduction of marginal discrepancies regardless of cement type or margin desing; b) knife edge finishing lines showed least dicrepancies regardless of cement type followed by the 135 degree shoulder, chamfer, bevelled 90 degree shoulder and 90 degree shoulder; c) internally relieved copings with chamfer, 135 degree shoulder and knife edge finishing lines showed no statiscally significant marginal discrepancies. This indicates that any of them yields favorable results; d) regarding cements, the least marginal discrepancies were found with Temp Bond NE followed by Temp Bond, Provy and finally by the Zinc Phosphate Cement (S.S.White) / Doutor
3

Efeito de diferentes tipos de soldagem na resistência à tração de estruturas fundidas com ligas de Ni-Cr / Effects of different types of welding on the tensile strenght of NI-Cr structures

Mansano, Romão Adalberto de Souza 21 May 2007 (has links)
A confecção de infra-estruturas metálicas em reabilitações orais, envolvem processos criteriosos principalmente no que concerne ao processo de fundição e soldagem das mesmas. O objetivo deste trabalho foi avaliar a resistência à tração de peças fundidas em monobloco com três diferentes métodos de soldagem: solda convencional (maçarico), solda a laser e solda TIG (tungstênio Inerte Gás). Oitenta padrões de plástico pré-fabricados (vinte para cada grupo) foram fundidos em liga de Ni-Cr, sendo o grupo controle (monobloco) unido previamente à fundição. Após, os corpos-de-prova do grupo teste foram divididos aleatoriamente para posterior soldagem e teste de resistência, realizado em uma máquina de ensaios mecânicos (Kratos). Os resultados médios (MPa) foram: monobloco 784,08, solda laser 588,42, solda convencional 366,80 e solda TIG 319,78. Os dados foram submetidos á analise estatística ANOVA e teste de Tukey (p,0,05), sendo que o grupo controle (monobloco) apresentou valores de resistência estatisticamente superior a todos os do grupo teste. Entre as peças soldadas, a solda laser apresentou valores de resistência estatisticamente superior em relação aos grupos (convencional e TIG), os quais não diferiram estatisticamente entre si. Concluí-se que apesar de ter havido diferenças estatísticas entre os grupos, os três métodos de soldagem podem ser indicadas pelos resultados altamente satisfatórios. / The development of metallic prosthetic framework in oral rehabilitation, involves critical processes specially related to casting and welding. The objective of this work was to evaluate the tensile strength of cast plates (monobloc) with three different welding methods: conventional welding (torch), laser welding and TIG welding (tungsten inert gas). Eighty pre fabricated plastic patterns (twenty for each group), were welded in Ni-Cr alloy, being the control group (monobloc) jointed previously to welding. The specimens of the test group were randomly divided for posterior welding and tensile strength test, which were performed in an universal testing machine (Kratos). The mean values (Mpa) were: monobloc (control) - 785.08, laser welding - 588.42, conventional welding - 366.80 and TIG 319.78. Data were analyzed by One-way ANOVA and Tukey test (p.0.05). The control group (monobloc) presented tensile strength values statistically superior compared to all test groups. Between the welded patterns, the laser welding presented tensile strength values statistically superior compared to the other welding groups (conventional and TIG), which did not show any statistically difference between them. Therefore, it can be concluded that despite of the statistical difference between the groups, the three welding methods can be indicated by the highly satisfactory results.
4

Análise química, microestrutural, determinação das propriedades mecânicas e dureza de ligas odontológicas (Ag Pd,Co Cr e NiCr) fundidas em diferentes temperaturas /

Olivieri, Karina Andrea Novaes. January 2000 (has links)
Orientador: Maximiliano Piero Neisser / Banca: Mario Alexandre Coelho Sinhoreti / Banca: Marco Antônio Bottino / Resumo: As restaurações metálicas fundidas são utilizadas em odontologia desde o século passado. Atualmente dispõe-se de recursos que possibilitam a obtenção de fundições mais precisas, graças ao aparecimento de novos materiais, de técnicas mais acuradas e, principalmente pelo fato do processo de fundição ser enfocado de maneira mais científica. O objetivo desse trabalho foi avaliar o desempenho metalúrgico e mecânico de ligas odontológicas quando submetidas a diferentes temperaturas. Para cada liga, Wiron 99 - Bego (NiCr), Wironit- Bego (CoCr) e Palliag M- Degussa (AgPd), foram obtidos, pela técnica de fundição por cera perdida, 20 corpos-de-prova, divididos em dois grupos de 10, fundidos em duas diferentes temperaturas: a) recomendada pelo fabricante (T1); b) acima da temperatura recomendada (T2), perfazendo um total de 60 corpos-de-prova. Foram realizadas análises químicas e metalográficas, por microscopia óptica, das ligas nas condições como recebida, T1 e T2. Também fez-se ensaios de tração de dureza Vickers nas condições T1 e T2. As microestruturas foram semelhantes nas condições CR, T1 e T2, sendo um pouco melhores na condição T1 que em T2. Os resultados não evidenciaram diferenças estatisticamente significantes para as respectivas ligas estudadas para as análises químicas e para os ensaios mecânicos. A dureza mostrou-se maior na condição corno recebida em comparação à T1 e T2 / Abstract: The metal restorations are used in Dentistry since /ast ce11tury. Nowadays we have resources that can to get castings more accurate, with news materiais and equipments and techniques more precises continue to be introduced with regularity in the scientific area. The purpose of this study was evaluates the metallurgical aspects of the dental alloys when they were submitted to different castings temperatures. To each alloy, Wiron 99- Rego (NiCr), Wironit- Bego (CoCr) and Palliag M- Degussa (AgPd), were cast, with lost wax technique, 20 specimens, separeted in two groups of 10 each one, in two different casting temperatures: a) in accordance with the manufactures' instructions (T1); b) above manufactures' instructions (T2). It was done chemical and metallographic ana!ysis wich optical microscope in the alloys in these conditions: no cast, T1 and T2. It was determined mechanical properties and hardness (T1 and T2). The microstructures were similar to no cast, T1 and T2, but T1 was few better than T2. The results didn't show significantly differences statistics to chemical analysis and to mechanical properties. The hardness were larger in T1 and T2 than no cast / Mestre
5

Avaliação do tipo de carregamento, pela análise de elementos finitos, sobre a resistência de união ao cisalhamento da interface metal/porcelana (Ni-Cr/vita omega 900) /

Kojima, Alberto Noriyuki. January 2005 (has links)
Orientador: Renato Susumu Nishioka / Banca: Eduardo Miyashita / Banca: Fernando Eidi Takahashi / Resumo: O propósito deste estudo foi comparar a influência dos dispositivos de carregamento pistão, fita de aço inoxidável e cinzel, usados em ensaios de união ao cisalhamento, para verificar a resistência na interface material restaurador/metal. Os valores dependem de uma complexa combinação de tensões e resultantes produzidas durante a aplicação das forças nas amostras sendo que as variações nas metodologias dos testes resultam em diferentes valores de resistência ao cisalhamento, o que dificulta a padronização e a comparação direta entre diferentes pesquisadores. Foram utilizados 36 corpos-de-prova (Ni-Cr, Wiron 99 - Bego e porcelana Vita Omega 900 - Vita ) divididos em 3 grupos (n = 12). Os corpos-de-prova foram submetidos aos ensaios de resistência ao cisalhamento em uma máquina de ensaio universal EMIC (modelo DL-2000, São José dos Pinhais - PR), com velocidade constante de 0,5 mm/min. Em seguida, os corpos-de-prova representativos de cada grupo foram examinados em microscopia eletrônica de varredura para a observação dos modos de falhas. A análise de elementos finitos foi utilizada para a verificação da distribuição de tensões sobre os corpos-de-prova. Os resultados foram submetidos à análise de variância e ao teste de Tukey em nível de 5% de significância, verificou-se que houve diferença estatisticamente significante entre os três dispositivos usados. O presente estudo mostrou que o dispositivo pistão obteve melhores resultados que o método convencional ISO 11405 e fita / Abstract: The purpose of this study was to compare the devices influence piston, stainless steel strip and chisel, used in shear bond tests to verify the resistance in the metal/porcelain interface. The values depend on a complex tensions combination and resultants produced during the application of the forces in the specimens and the variations in the methodologies of the tests result in differents resistances values to shear bond strength, what complicates the standardization and the direct comparison between different researchers. They were used 36 specimens (Ni-Cr, Wiron 99 - Bego and porcelain Vita Omega 900 - Vita ) divided into three groups (n = 12). The specimens were submitted to the shear bond strength in a universal testing machine EMIC (model DL-2000, São José dos Pinhais - PR), with a crosshead speed of 0,5 mm/min. After, the representative sets of each group were examined in scanning electronic microscopy for the observation of the failures. The finite elements analysis was used to verifiy the tensions distribution on the specimens. The results were submitted to the analysis of variance and to Tukey's Test in the level of 5%, it was verified that there was significant statistically difference between the three devices used. The present study showed that the piston device obtained better results than the conventional method ISO 11405 and strip / Mestre
6

Estudo da biocompatibilidade da liga Ti-6AI-7Nb e titânio de grau 2 em tíbia de coelhos /

Momose, Dalton Reis. January 2002 (has links)
Orientador: Yasmin Rodarte Carvalho / Banca: Carlos Alberto Alves de Cairo / Banca: Antonio Olavo Cardoso Jorge / Resumo: O presente trabalho teve como objetivo analisar a reação do tecido ósseo a implantes confeccionados com a liga de titânio contendo alumínio e nióbio (Ti-6AI-7Nb) em relação ao titânio comercialmente puro (titânio de grau 2). Foram obtidos 48 pinos por metalurgia do pó, os quais foram usinados em implantes de 2,0mm de diâmetro, 7,5mm de comprimento e com 1 ,67mm de rosca, o suficiente para fixação iniciai. O experimento foi realizado em 24 coelhos da raça Nova Zelândia com 3,5 Kg e com aproximadamente três meses e meio de vida. Quatro implantes foram colocados por animal, sendo na tíbia esquerda implantados dois implantes da liga Ti-6AI-7Nb, equidistantes 4cm, e na direita o titânio grau 2. Após os períodos de 21, 42 e 84 dias, os animais foram sacrificados e a interface entre o implante e o tecido ósseo foi analisado em nível histológico, em cortes descalcificados e não descalcificados. As imagens dos cortes não descalcificados foram digitalizadas e submetidas ao programa de análise de imagem, por meio do qual foi calculada a área do osso neoformado entre os passos da rosca. Os resultados mostraram que não houve diferenças da resposta do tecido ósseo ao tipo de material implantado. Em relação ao período de análise, observou-se aos 21 dias maior quantidade de espaços medulares e menor quantidade de osso neoformado que nos outros períodos. Não houve diferença significativa entre os grupos de 42 e 84 dias, que apresentavam tecido ósseo com aspecto mais maduro. Concluiu-se, com o trabalho, que os períodos de 21 e 42 dias são suficientes para analisar a ósseo integração de implantes que não sofreram cargas funcionais, e que a liga de titânio Ti-6AI-7Nb apresentou comportamento semelhante ao titânio de grau 2, podendo ser empregada como alternativa de uso na biomedicina / Abstract: The aim of this work was to analyzed bane tissue reaction concemig to implants materials made of by titanium alloy containing aluminum and niobium (Ti-6Af-7Nb) and compared with pure commercial titanium (grade 2)- The essay was performed in 24 rabbits - New Zealand strain - about 3, 5 Kg e a eh and three and half months of age, in which were placed bodies test manufactured by powder metallurgical technology, and latter on trimmed to aflow final dimensions around 2, O mm in diameter: 7,5 mm in length and 1,67mm in screw saw, size enough to initial bane fixation. Four implants were p/aced on each animal: two Ti-6Af-7Nb in to left tibia bone, distant 4cm from one each other, and last two grade 2 titanium ín to right tibia bone. The animals were sacrificed at different periods of time (21, 42 and 84 days), and the interfaces between implants and bone tissue were histologically analyzed in decalcified and non decalcified samples. image from non decalcified samples were obtained, and then analyzed in a specific image software (lmage G - NIH, USA). Area of new bane tissue formation between grooves were calculated. Data were statistically analyzed by ANOVA and Tukey test. Our results showed there were no statstical differences in bane tissue responses related to this two implant materials. Conceming to the analyzed period we should realized that in 21-dayssamples a quite large amount of medullar spaces and woven bane were presented when compared with the others two periods. The following 42-days-samples and 84-dayssamples díd not show any differences among them. We may conclude that 21 and 42 days were sufficient enough time to analyze osseo integration over implants that did not submitted to functional stress. Finally, we may say that Ti-6Af-7Nb alloy showed similar behavior compared to grade 2 titanium, and tl1erefore, it might be used in medicine for biological applications / Mestre
7

Caracterização microestrutural e resistência à corrosão de ligas Ni-Cr-Mo refundidas utilizadas em próteses dentárias /

Sousa, Lucíola Lucena de. January 2005 (has links)
Resumo: O objetivo deste trabalho foi estudar o efeito de diferentes processos de refundição e resfriamento na microestrutura e nas propriedades mecânicas e eletroquímicas de duas ligas de Ni-Cr-Mo, Wiron 99 e Wironia, utilizadas em próteses dentárias fixas. As ligas como recebidas (bruta de fusão) foram refundidas em chama aberta com maçarico oxi-GLP e por indução em forno de alta freqüência utilizando diferentes velocidades de resfriamento. As microestruturas reveladas por ataque eletroquímico nas amostras bruta de fusão (BF), foram analisadas por microscopia ótica e eletrônica de varredura, apresentam caráter dendrítico; as amostras refundidas apresentam duas fases: uma solução sólida de Ni-Cr-Mo e precipitados. A região de precipitados tem maior teor de Mo que na fase principal. As amostras Wironia refundida em chama aberta (MRL), refundidas por indução seguida de resfriamento em água fria (IRR) e seguida de resfriamento natural (IRL) apresentam maior número de precipitados que a Wiron 99. O estudo eletroquímico foi realizado em meio de NaCl 0,9% em massa, pH 6 a 37ºC, utilizando as técnicas de medidas de potencial em circuito aberto, polarização potenciodinâmica e voltametria cíclica. Diferentes procedimentos de refundição alteram parâmetros eletroquímicos como potencial de estabilização em circuito aberto, densidade de corrente e intervalo de passivação. As alterações foram mais pronunciadas para as ligas Wironia IRL e Wiron 99 IRL. Ensaios de imersão durante um ano em solução de NaCl 0,9% mostraram dissolução de Ni, Cr e Mo em maior quantidade para a Wironia MRL e IRR. A dureza e a resistência à abrasão foram menores nas ligas refundidas do que nas BF. Diferentes procedimentos de refundição e resfriamento afetam a microestrutura e a resistência à corrosão destas ligas. / Abstract: This work aim has been to study the effect of different recast and cooling processes in microstructure and in mechanical and electrochemical properties of two Ni-Cr-Mo alloys, Wiron 99 and Wironia, used in fixed dental prostheses. The alloys as-received (as-cast) have been recast in an open flame (oxy-LPG torch) and through induction in high frequency furnace by using different cooling rates. Microstructures revealed through as-cast (AC) electrochemical attack analyzed through light and scanning electronic microscopy present dendritic character; recast samples present two phases: a Ni-Cr-Mo solid solution and precipitates. Precipitates region has Mo content greater than the main phase. Wironia samples recast through open flame (TSC - Torch followed by slow cooling), recast through induction followed by cooling in cold water (IRC - Induction followed by rapid cooling) and then by natural cooling (ISC - Induction followed by slow cooling) present a precipitate number greater than Wiron 99. Electrochemical study has been carried out in 0.9% NaCl, pH 6 at 37°C, by using open circuit potential techniques, potentiodynamic polarization and cyclic voltammetry. Different recast procedures change electrochemical parameters as stabilizing potential in open circuit, current density and passivation interval. Changes have been more markedly for ISC Wironia and ISC Wiron 99. Immersion tests during one year in NaCl 0.9% have displayed Ni, Cr and Mo dissolution in major quantity for TSC and IRC Wironia. Hardness and abrasion resistance have been smaller for recast than in AC alloys. Different recast and cooling procedures affect microstructure and corrosion resistance of these alloys. / Orientador: Hamilton de Felipe / Coorientador: Eduardo Norberto Codaro / Banca: Roberto Zenhei Nakazato / Banca: Gilberto Luis Jardim Pinto da Silva / Mestre
8

Avaliação da união de ligas metálicas à cerâmica por meio de ensaio de cisalhamento, e análise pela microscopia e eds /

Hilgert, Edson. January 2005 (has links)
Orientador : Estevão Tomomitsu Kimpara / Doutor
9

Desenvolvimento e caracterização de ligas de Co-Cr-Mo /

Martinelli, Carolina da Silva Machado. January 2016 (has links)
Orientador: Estevão Tomomitsu Kimpara / Co-orientador: Ana Paula Rosifini Alves Claro / Banca: Rubens Nisie Tango / Banca: Marina Amaral / Banca: Luís Augusto Sousa Marque da Rocha / Banca: André da Silva Antunes / Resumo: As ligas de Co-Cr têm o uso consagrado para reabilitação oral com próteses dentárias. Os procedimentos reabilitadores orais por implantes osseointegrados destacaram novas necessidades biomecânicas e estruturais das ligas metálicas. O objetivo deste estudo foi desenvolver e caracterizar três ligas metálicas de CoCr-Mo experimentais, para aplicação odontológica. Foram confeccionadas ligas de Co-Cr-Mo, com percentuais crescentes de Mo (6, 7 e 8% - A, B e C, respectivamente), por duas técnicas de processamento: L2, fusão para acréscimo de Mo a uma liga comercial certificada (American Society for Testing and Materials, 1996) (L1); e L3, fusão dos metais Co, Cr e Mo, comercialmente puros. As ligas em estudo foram caracterizadas microestruturalmente por microscopia eletrônica de varredura (MEV), espectroscopia de energia dispersiva (EDS), difração de raios X (DRX), fluorescência de raios X (XDR); fisicamente por microdureza, resistência à corrosão. Fibroblastos dérmicos humanos foram utilizados para avaliar a citotoxicidade das ligas experimentais após 1, 4 e 7 dias de cultura celular. Organização citoesquelética, adesão, viabilidade, morfologia e diferenciação celular foram avaliados por microscopia de fluorescência, análise bioquímica e MEV. Os resultados obtidos permitiram concluir que as ligas experimentais (L2A, L2B, L2C, L3A, L3B e L3C) apresentaram desempenho microsestrutural, mecânico e citotóxico superior à L1, sendo indicada para utilização biomédica e odontológica / Abstract: In Dentistry, the Co-Cr alloys are general used for oral rehabilitation by dental prosthesis. The oral rehabilitation procedures by osseointegrated implants point out to new metal alloys' biomechanical and structural necessities. The aim of this study was develop and characterize three experimental Co-Cr-Mo alloys, for dental application. Three alloys will be made out with different Mo's percentages by two processing techniques: L2, casting by addition of Mo to a certified commercial Co-Cr alloy (American Society for Testing and Materials, 1996) (L1); and L3, casting of purified commercial metals (Co, Cr, Mo). The experimental alloys were characterized by microstructure by digital optical microscopy, scanning electron microscopy, energy dispersive X-ray spectrometry, X-ray diffraction and X-ray fluorescence; and mechanically by microhardness and corrosion resistance. Human dermal fibroblasts were used to evaluate the biocompatibility of experimental Co-Cr alloys after 1, 4 and 7 days of culture. Cellular adhesion, proliferation, viability, cytoskeletal organization and morphology were investigated using fluorescence microscope, biochemical assay and SEM. Based on data was possible to concluded that experimental alloys (L2A, L2B, L2C, L3A, L3B e L3C) shown higher performance for microstructure, mechanical and cytotoxic as L1 and they are recommend to biomedical and dentistry applications / Doutor
10

Efeito de diferentes tipos de soldagem na resistência à tração de estruturas fundidas com ligas de Ni-Cr / Effects of different types of welding on the tensile strenght of NI-Cr structures

Romão Adalberto de Souza Mansano 21 May 2007 (has links)
A confecção de infra-estruturas metálicas em reabilitações orais, envolvem processos criteriosos principalmente no que concerne ao processo de fundição e soldagem das mesmas. O objetivo deste trabalho foi avaliar a resistência à tração de peças fundidas em monobloco com três diferentes métodos de soldagem: solda convencional (maçarico), solda a laser e solda TIG (tungstênio Inerte Gás). Oitenta padrões de plástico pré-fabricados (vinte para cada grupo) foram fundidos em liga de Ni-Cr, sendo o grupo controle (monobloco) unido previamente à fundição. Após, os corpos-de-prova do grupo teste foram divididos aleatoriamente para posterior soldagem e teste de resistência, realizado em uma máquina de ensaios mecânicos (Kratos). Os resultados médios (MPa) foram: monobloco 784,08, solda laser 588,42, solda convencional 366,80 e solda TIG 319,78. Os dados foram submetidos á analise estatística ANOVA e teste de Tukey (p,0,05), sendo que o grupo controle (monobloco) apresentou valores de resistência estatisticamente superior a todos os do grupo teste. Entre as peças soldadas, a solda laser apresentou valores de resistência estatisticamente superior em relação aos grupos (convencional e TIG), os quais não diferiram estatisticamente entre si. Concluí-se que apesar de ter havido diferenças estatísticas entre os grupos, os três métodos de soldagem podem ser indicadas pelos resultados altamente satisfatórios. / The development of metallic prosthetic framework in oral rehabilitation, involves critical processes specially related to casting and welding. The objective of this work was to evaluate the tensile strength of cast plates (monobloc) with three different welding methods: conventional welding (torch), laser welding and TIG welding (tungsten inert gas). Eighty pre fabricated plastic patterns (twenty for each group), were welded in Ni-Cr alloy, being the control group (monobloc) jointed previously to welding. The specimens of the test group were randomly divided for posterior welding and tensile strength test, which were performed in an universal testing machine (Kratos). The mean values (Mpa) were: monobloc (control) - 785.08, laser welding - 588.42, conventional welding - 366.80 and TIG 319.78. Data were analyzed by One-way ANOVA and Tukey test (p.0.05). The control group (monobloc) presented tensile strength values statistically superior compared to all test groups. Between the welded patterns, the laser welding presented tensile strength values statistically superior compared to the other welding groups (conventional and TIG), which did not show any statistically difference between them. Therefore, it can be concluded that despite of the statistical difference between the groups, the three welding methods can be indicated by the highly satisfactory results.

Page generated in 0.0453 seconds