• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Dispositivos LED para polimerização de resinas compostas dentais: comparação com outras fontes de luz. / LED source for dental composite photo activation.

Medeiros, Igor Studart 18 December 2001 (has links)
Muito se tem feito para a melhoria das resinas compostas polimerizadas através de luz visível. A maioria dos estudos restringe-se apenas às fontes de luz convencionais e pouco tem sido feito no sentido de viabilizar novas fontes, introduzindo novas tecnologias nesta área do conhecimento. No intuito de desenvolver novos dispositivos de geração de luz para polimeração das resinas compostas dentais, o Grupo de Óptica tem sido um dos pioneiros mundiais no desenvolvimento e caracterização de dispositivos usando LEDs azuis. Neste trabalho, verificou-se a viabilidade de um novo dispositivo à base de LEDS azuis, excecutando-se uma análise comparativa com o aparelho de polimerização convencional e o laser de argônio. Para a validação deste novo dispositivo, executaram-se testes de microdureza Vickers em espécimes de resinas compostas de diferentes espessuras, expostos a diferentes tempos de irradiação. Foi executado o teste de análise térmica, com resolução temporal, durante o processo de exposição à luz para polimerização com finalidade de verificar a variação térmica pulpar em terceiros molares recém-extraídos. Em seguida, determinou-se a variação das propriedades de microdureza e resistência à tração diametral após a armazenagem em alguns agentes químicos encontrados na cavidade oral. Os resultados demonstram que o dispositivo à base de LEDs apresenta-se viável para polimerização de compósitos dentais, com algumas vantagens em relação a outras fontes de luz utilizadas para essa finalidade. / The improvement of composite resins polymerization through visible light has been an important research topic. The majority of the studies, however, are restricted only to the conventional light sources and little has been made to viable new sources, introducing new technologies in this area of the knowledge. In intention to develop new light sources for dental composite resins polymerization, the Optics Groups is one of the pioneers in the development and characterization of devices, using blue LEDs for this purpose. In this work, it was verified the viability of a new device based in blue LEDs, executing a comparative analysis with the conventional polymerization device and the argon laser. It was executed the test of thermal analysis during the process of exposure to the polymerization light, to verify the thermal variation in the pulpal chambers of third molars caries free. After that, it was determined the variation of microhardness and diametral tensile strength properties when composite specimens were storaged in chemical agents found in the oral cavity. The results have demonstrated that the LEDs based device present is viable for polymerization of dental composites with some advantages in relation to other used light sources.
2

Dispositivos LED para polimerização de resinas compostas dentais: comparação com outras fontes de luz. / LED source for dental composite photo activation.

Igor Studart Medeiros 18 December 2001 (has links)
Muito se tem feito para a melhoria das resinas compostas polimerizadas através de luz visível. A maioria dos estudos restringe-se apenas às fontes de luz convencionais e pouco tem sido feito no sentido de viabilizar novas fontes, introduzindo novas tecnologias nesta área do conhecimento. No intuito de desenvolver novos dispositivos de geração de luz para polimeração das resinas compostas dentais, o Grupo de Óptica tem sido um dos pioneiros mundiais no desenvolvimento e caracterização de dispositivos usando LEDs azuis. Neste trabalho, verificou-se a viabilidade de um novo dispositivo à base de LEDS azuis, excecutando-se uma análise comparativa com o aparelho de polimerização convencional e o laser de argônio. Para a validação deste novo dispositivo, executaram-se testes de microdureza Vickers em espécimes de resinas compostas de diferentes espessuras, expostos a diferentes tempos de irradiação. Foi executado o teste de análise térmica, com resolução temporal, durante o processo de exposição à luz para polimerização com finalidade de verificar a variação térmica pulpar em terceiros molares recém-extraídos. Em seguida, determinou-se a variação das propriedades de microdureza e resistência à tração diametral após a armazenagem em alguns agentes químicos encontrados na cavidade oral. Os resultados demonstram que o dispositivo à base de LEDs apresenta-se viável para polimerização de compósitos dentais, com algumas vantagens em relação a outras fontes de luz utilizadas para essa finalidade. / The improvement of composite resins polymerization through visible light has been an important research topic. The majority of the studies, however, are restricted only to the conventional light sources and little has been made to viable new sources, introducing new technologies in this area of the knowledge. In intention to develop new light sources for dental composite resins polymerization, the Optics Groups is one of the pioneers in the development and characterization of devices, using blue LEDs for this purpose. In this work, it was verified the viability of a new device based in blue LEDs, executing a comparative analysis with the conventional polymerization device and the argon laser. It was executed the test of thermal analysis during the process of exposure to the polymerization light, to verify the thermal variation in the pulpal chambers of third molars caries free. After that, it was determined the variation of microhardness and diametral tensile strength properties when composite specimens were storaged in chemical agents found in the oral cavity. The results have demonstrated that the LEDs based device present is viable for polymerization of dental composites with some advantages in relation to other used light sources.
3

Effect of different resin cements on shear bond strength of CAD-CAM crowns fabricated from hybrid materials.

Zayed, Mona January 2021 (has links)
Magister Scientiae Dentium - MSc(Dent) / CAD/CAM crowns have become popular due to the many advantages associated with this technology. Optimal bonding adhesion is crucial for the durability of these indirect restorations and many factors influence this crucial step. Currently, there is no consensus or evidence-based guidelines on the best adhesion protocol for CAD/CAM crowns fabricated from hybrid materials. This study was aimed at investigating the influence of three types of resin cements on the shear bond strength of a hybrid CAD/CAM material in vitro.
4

CORRELAÇÃO ENTRE GRAU DE CONVERSÃO E RESISTÊNCIA DE UNIÃO DE SISTEMAS ADESIVOS AUTOCONDICIONANTES / CORRELATION BETWEEN DEGREE OF CONVERSION AND BOND STRENGTH OF THE SELF-ETCHING ADHESIVE SYSTEM

Borges, Marciano de Freitas 24 February 2010 (has links)
Objective: The aim of this study was to analyses the relationship between the degree of conversion of double bonds of self-etching adhesives and microshear bond strength on dentin. Materials and methods: For microshear testing twenty third molar caries free were selected. They had their crowns sectioned longitudinally so as to obtain slices that were randomly chosen and divided into four groups according to the adhesive system, Single Bond (SB), Clearfil SEBond (CL) , Adhese (AD) and Gbond (GB). The slices were included into epoxy resin, and then cylindrical restorations were built with an area of 1.0 mm in diameter and 2.0 mm in height, around ten restorations per group, using a starch matrix. After 24 hours the specimens were tested for bond strength. To analyze the degree of conversion of these systems, a drop of adhesive was dispensed on a glass plate and after 20 seconds polymerized, forming a film of adhesive. After 24 hours, these films were pulverized and mixed with potassium bromide, pressed in a hydraulic press to form an insert for analysis with the spectrophotometer - FT-IR. The data of shear bond strength and degree of conversion of each specimen were submitted to ANOVA and Tukey s test (p = 0.05). Results: The SB adhesive system had mean values of bond strength statistically higher than AD and GB, but no statistical difference was found with Cl. Among the self-etching systems, the highest average shear bond strength was achieved with the application of the union CL, followed by GB and AD systems, which were not statistically different. Regarding the degree of conversion, similar statistical results were found for the systems SB and CL, and despite the SB had a higher average it, did not differ from CL. The adhesive system SB and CL showed higher values in AD and GB. The AD, showed values higher than the GB. Conclusion: The degree of conversion is affected by several factors related to the complex mixture of adhesive systems, which somehow contribute to their bond strength. / Objetivo: O objetivo desse estudo foi avaliar o grau de conversão de sistemas adesivos autocondiconantes em dentina e correlacioná-los com a resistência ao teste de microcisalhamento. Materiais e Métodos: Para o ensaio de microcisalhamento foram selecionados vinte terceiros molares livres de cárie, os quais tiveram suas coroas seccionadas longitudinalmente de modo a se obter fatias, que, aleatoriamente, foram divididas em quatro grupos, de acordo com o sistema adesivo uilizado, Single Bond (SB), Clearfil SE Bond (CL), Adhese (AD) e Gbond (GB). As fatias foram incluídas em tubos de PVC com resina acrílica e, em seguida, foram construídas restaurações cilíndricas com uma área de 1,0 mm de diâmetro e 2,0 mm de altura, em torno de dez restaurações por grupo, por meio de uma matriz de amido. Após 24 horas, os corpos de prova foram submetidos ao ensaio de microcisalhamento. Para análise do grau de conversão desses sistemas, uma gota do adesivo foi dispensada sobre uma placa de vidro e, após 20 segundos, foram fotopolimerizadas, formando uma película de adesivo. Após 24h, essas películas foram pulverizadas e misturadas com brometo de potássio, prensadas em prensa hidráulica de modo a formar uma pastilha para análise no espectofotômetro - FT-IR. Os dados obtidos da resistência de união e do grau de conversão foram submetidos à análise de variância e teste de Tukey (p = 0.05). Resultados: O sistema de união SB apresentou valores médios de resistência de união ao microcisalhamento estatisticamente superior AD e GB, mas não apresentou diferença estatística em relação ao sistema Cl. Dentre os sistemas autocondicionantes, as maiores médias no ensaio mecânico foram obtidas com a aplicação do sistema de união CL, seguido pelos sistemas AD e GB, que não foram estatisticamente diferentes entre si. Em relação ao grau de conversão, resultados estatísticos semelhantes foram encontrados para os sistemas SB e CL, que, apesar do SB apresentar uma maior média, não diferiu do CL. O sistema adesivo SB e CL apresentaram valores médios superiores ao AD e GB. O AD, que por sua vez, apresentou valores médios maiores que o GB. Conclusão: O grau de conversão é afetado por diversos fatores relacionados à mistura complexa dos sistemas adesivos, que, de certo modo, repercutirá na sua resistência de união.

Page generated in 0.0325 seconds