• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estereologia, imuno-histoquímica e microscopia eletrônica de varredura na análise da reação tecidual a implantes de discos de adesivo dentinário fotoativado, hidróxido de cálcio e cimento de ionômero de vidro: estudo experimental em ratos / Stereology, imunohistochemistry, and scanning electron microscopy in the analysis of tissue reaction to disks implants of light-cured dentin adhesive, calcium hydroxide, and glass ionomer cement: experimental study in rats

Rogério Luiz de Oliveira Mussel 17 May 2002 (has links)
Objetivo: avaliar a biocompatibilidade de materiais indicados como protetores pulpar no tecido subcutâneo de ratos ao longo do tempo. Métodos: Implantes padronizados de Hidróxido de Cálcio (HC), Cimento de Ionômero de Vidro (CIV) e Adesivo Dentinário Fotoativado (ADF) foram colocados cirurgicamente no dorso de ratos Wistar e deixados por 15 e 30 dias (cada grupo com 5 animais) e os respectivos grupos sham (S). Após a experimentação os animais foram sacrificados e material do dorso dos animais foi retirado para estudo ao microscópio de luz com estereologia e imuno-histoquímica para &#945;-actina de músculo liso (ACML, detecção de miofibroblastos). As pastilhas e a superfície das cápsulas fibrosas foram analisadas quanto a textura, em microscopia eletrônica de varredura (MEV) com microanálise. Resultados: Houve diferenças na fibrose e no número de mastócitos na região peri-implante dependente do tipo de implante. Não foram detectados miofibroblastos expressando ACML. O menor valor de densidade volumétrica de fibrose intersticial (Vv[f]) ocorreu no grupo HC, e o maior no grupo ADF (diferença significativa em relação ao grupo S, nos dois tempos experimentais, p<0,05). Entretanto, aos 30 dias, houve acréscimo de 30% de Vv[f] do grupo ADF, determinando, neste período, diferença significativa em relação ao grupo HC. Quanto a densidade numérica de mastócitos por área (NA[mastócito]) o menor valor ocorreu no grupo HC sem diferença para o grupo S, mas diferença para o grupo ADF (este com o maior valor de NA[mastócito] nos dois tempos experimentais). O grupo CIV apresentou, para Vv[f] e NA[mastócito], durante toda a experimentação, resultados intermediários aos grupos HC e ADF. Houve fibrose discreta e restrita a área cirúrgica com poucos mastócitos juntos aos vasos no grupo S. Houve correlação positiva para Vv[f] e NA[mastócito], no grupo ADF. Ao MEV viu-se interação, no grupo HC, entre o material da pastilha e sua cápsula fibrótica, mas não nos grupos ADF e CIV. Conclusão: Os materiais estudados induziram a formação de fibrose e migração de mastócitos de modo diferenciado. Os resultados sugerem o HC como o material mais compatível biologicamente dentre os testados neste trabalho. / Purpose: to evaluate the biocompatibility of some pulpar protecting materials in the subcutaneous tissue of rats along the time. Methods: standardized implants of Calcium Hydroxide (CH), Glass Ionomer Cement (GIC) and Light-cured Dentin Adhesive (LDA) surgically were put in the back of Wistar rats and left by 15 and 30 days (each group with 5 animals) and the respective sham groups (S). After the experimentation the animals were sacrificed and material from the back of the animals was removed for study with light microscope, stereology and immunohistochemistry for smooth muscle alfa-actin (SMAA, myofibroblast detection). The implants and the fibrous capsule surfaces were analyzed with the scanning electronic microscopy (SEM) adapted with microanalysis. Results: the fibrosis and the number of mastocytes were different in the implant area depending of the implant type. Myofibroblasts were not detected expressing SMAA. The smallest value of the volume density of interstitial fibrosis (Vv[f]) occured in the CH group, and the largest in the LDA group (the difference was significant in relation to the S group, in the two experimental times, p < 0.05). However, to the 30 days, the Vv[f] of the LDA group increase 30%, being different from the CH group in this period. The numerical density of mastocytes per area (NA[mastocyte]) was smaller in the CH group without difference for the S group, but with difference from the LDA group (this group had the largest NA[mastocyte] value in the two experimental times). The GIC group had, for Vv[f] and NA[mastocyte] all experimentation time, intermediary values ranging from CH to LDA values. There was discreet and restricted fibrosis in the surgical area with few mastocytes associated to vessels in the S group. There was positive correlation for Vv[f] and NA[mastocyte] in the LDA group. In the CH group the SEM observed interaction between the implant material and its fibrotic capsule, but not in the LDA and GIC groups. Conclusion: The studied materials induced the fibrosis formation and mastocytes migration in a differentiated way. The results suggest that CH as the most biologically compatible material among the materials tested in this work.
2

Estereologia, imuno-histoquímica e microscopia eletrônica de varredura na análise da reação tecidual a implantes de discos de adesivo dentinário fotoativado, hidróxido de cálcio e cimento de ionômero de vidro: estudo experimental em ratos / Stereology, imunohistochemistry, and scanning electron microscopy in the analysis of tissue reaction to disks implants of light-cured dentin adhesive, calcium hydroxide, and glass ionomer cement: experimental study in rats

Rogério Luiz de Oliveira Mussel 17 May 2002 (has links)
Objetivo: avaliar a biocompatibilidade de materiais indicados como protetores pulpar no tecido subcutâneo de ratos ao longo do tempo. Métodos: Implantes padronizados de Hidróxido de Cálcio (HC), Cimento de Ionômero de Vidro (CIV) e Adesivo Dentinário Fotoativado (ADF) foram colocados cirurgicamente no dorso de ratos Wistar e deixados por 15 e 30 dias (cada grupo com 5 animais) e os respectivos grupos sham (S). Após a experimentação os animais foram sacrificados e material do dorso dos animais foi retirado para estudo ao microscópio de luz com estereologia e imuno-histoquímica para &#945;-actina de músculo liso (ACML, detecção de miofibroblastos). As pastilhas e a superfície das cápsulas fibrosas foram analisadas quanto a textura, em microscopia eletrônica de varredura (MEV) com microanálise. Resultados: Houve diferenças na fibrose e no número de mastócitos na região peri-implante dependente do tipo de implante. Não foram detectados miofibroblastos expressando ACML. O menor valor de densidade volumétrica de fibrose intersticial (Vv[f]) ocorreu no grupo HC, e o maior no grupo ADF (diferença significativa em relação ao grupo S, nos dois tempos experimentais, p<0,05). Entretanto, aos 30 dias, houve acréscimo de 30% de Vv[f] do grupo ADF, determinando, neste período, diferença significativa em relação ao grupo HC. Quanto a densidade numérica de mastócitos por área (NA[mastócito]) o menor valor ocorreu no grupo HC sem diferença para o grupo S, mas diferença para o grupo ADF (este com o maior valor de NA[mastócito] nos dois tempos experimentais). O grupo CIV apresentou, para Vv[f] e NA[mastócito], durante toda a experimentação, resultados intermediários aos grupos HC e ADF. Houve fibrose discreta e restrita a área cirúrgica com poucos mastócitos juntos aos vasos no grupo S. Houve correlação positiva para Vv[f] e NA[mastócito], no grupo ADF. Ao MEV viu-se interação, no grupo HC, entre o material da pastilha e sua cápsula fibrótica, mas não nos grupos ADF e CIV. Conclusão: Os materiais estudados induziram a formação de fibrose e migração de mastócitos de modo diferenciado. Os resultados sugerem o HC como o material mais compatível biologicamente dentre os testados neste trabalho. / Purpose: to evaluate the biocompatibility of some pulpar protecting materials in the subcutaneous tissue of rats along the time. Methods: standardized implants of Calcium Hydroxide (CH), Glass Ionomer Cement (GIC) and Light-cured Dentin Adhesive (LDA) surgically were put in the back of Wistar rats and left by 15 and 30 days (each group with 5 animals) and the respective sham groups (S). After the experimentation the animals were sacrificed and material from the back of the animals was removed for study with light microscope, stereology and immunohistochemistry for smooth muscle alfa-actin (SMAA, myofibroblast detection). The implants and the fibrous capsule surfaces were analyzed with the scanning electronic microscopy (SEM) adapted with microanalysis. Results: the fibrosis and the number of mastocytes were different in the implant area depending of the implant type. Myofibroblasts were not detected expressing SMAA. The smallest value of the volume density of interstitial fibrosis (Vv[f]) occured in the CH group, and the largest in the LDA group (the difference was significant in relation to the S group, in the two experimental times, p < 0.05). However, to the 30 days, the Vv[f] of the LDA group increase 30%, being different from the CH group in this period. The numerical density of mastocytes per area (NA[mastocyte]) was smaller in the CH group without difference for the S group, but with difference from the LDA group (this group had the largest NA[mastocyte] value in the two experimental times). The GIC group had, for Vv[f] and NA[mastocyte] all experimentation time, intermediary values ranging from CH to LDA values. There was discreet and restricted fibrosis in the surgical area with few mastocytes associated to vessels in the S group. There was positive correlation for Vv[f] and NA[mastocyte] in the LDA group. In the CH group the SEM observed interaction between the implant material and its fibrotic capsule, but not in the LDA and GIC groups. Conclusion: The studied materials induced the fibrosis formation and mastocytes migration in a differentiated way. The results suggest that CH as the most biologically compatible material among the materials tested in this work.

Page generated in 0.0692 seconds