• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 140
  • 66
  • 44
  • 44
  • 17
  • 12
  • 9
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • Tagged with
  • 406
  • 77
  • 42
  • 41
  • 41
  • 40
  • 37
  • 36
  • 36
  • 35
  • 34
  • 32
  • 29
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Terrestrial and freshwater turtles of early cretaceous Australia

Smith, Elizabeth T, Biological, Earth & Environmental Sciences, Faculty of Science, UNSW January 2009 (has links)
An unusual turtle fauna from Lightning Ridge, New South Wales (Albian) reveals that Australian turtles had a more extensive Mesozoic history than previously indicated. Reevaluation of several primitive groups provides novel information on turtle evolution in the southern hemisphere. Seven turtle taxa are identified at Lightning Ridge. Two are Testudines indet. and two indeterminate chelid groups are evinced by isolated elements. Three new taxa are assigned to the new family Spoochelyidae in the superfamily Meiolanoidea. Spoochelys ormondea n. fam., gen. et sp., Sunflashemys bartondracketti n. gen. et sp. and Opalania baagiwayamba n. gen. et sp. are predominantly land-living turtles with high-domed shells and short manus and pes. The sister-group relationship with the Meiolaniidae, supported by a suite of cranial and postcranial synapomorphies, increases the stratigraphic range of the horned turtles by around ~ 50 my. Primitive structures in Spoochelys (postparietal, supratemporal and interpterygoid vacuity), occur with derived features that are variably developed across Triassic and Jurassic turtles. Phylogenetic analysis precariously resolves the meiolanoids as sister group to a clade containing Palaeochersis and Proterochersis. Limited pleurodiran attributes suggest that meiolanoids may be pleurodiromorphs, closer to primitive pleurodires than to cryptodires. As basal ‘side-necked’ turtles, the Lightning Ridge meiolanoids permit first insights into cranial and postcranial progressions in pleurodiran stem taxa. Evidence of diverse meiolanoids in Early Cretaceous Australia and ancient radiations of meiolanoid-like turtles in southern Pangea, suggest that the horned turtles are a Triassic group and that the dichotomy between Pleurodira and Cryptodira occurred well before the Late Triassic. Early Cretaceous chelids at Lightning Ridge occur at higher palaeolatitude than in South America. The temporal range of Australian chelids is extended by ~ 50 my, demonstrating that chelids had a Jurassic history in Australia, with broad diversifications across the polar supercontinent. The palaeoecological setting of Lightning Ridge is comprehensively described for the first time. Diverse invertebrates and vertebrates include terrestrial, freshwater aquatic and rare marine forms that are anomalous at this near-polar palaeolatitude (~65-70oS). The anachronistic occurrence in Early Cretaceous Australia of distinctive radiations of ‘Triassic-type’ turtles, and other relic groups, implies prolonged intervals of biogeographic isolation in the eastern provinces of Pangea.
102

Terrestrial and freshwater turtles of early cretaceous Australia

Smith, Elizabeth T, Biological, Earth & Environmental Sciences, Faculty of Science, UNSW January 2009 (has links)
An unusual turtle fauna from Lightning Ridge, New South Wales (Albian) reveals that Australian turtles had a more extensive Mesozoic history than previously indicated. Reevaluation of several primitive groups provides novel information on turtle evolution in the southern hemisphere. Seven turtle taxa are identified at Lightning Ridge. Two are Testudines indet. and two indeterminate chelid groups are evinced by isolated elements. Three new taxa are assigned to the new family Spoochelyidae in the superfamily Meiolanoidea. Spoochelys ormondea n. fam., gen. et sp., Sunflashemys bartondracketti n. gen. et sp. and Opalania baagiwayamba n. gen. et sp. are predominantly land-living turtles with high-domed shells and short manus and pes. The sister-group relationship with the Meiolaniidae, supported by a suite of cranial and postcranial synapomorphies, increases the stratigraphic range of the horned turtles by around ~ 50 my. Primitive structures in Spoochelys (postparietal, supratemporal and interpterygoid vacuity), occur with derived features that are variably developed across Triassic and Jurassic turtles. Phylogenetic analysis precariously resolves the meiolanoids as sister group to a clade containing Palaeochersis and Proterochersis. Limited pleurodiran attributes suggest that meiolanoids may be pleurodiromorphs, closer to primitive pleurodires than to cryptodires. As basal ‘side-necked’ turtles, the Lightning Ridge meiolanoids permit first insights into cranial and postcranial progressions in pleurodiran stem taxa. Evidence of diverse meiolanoids in Early Cretaceous Australia and ancient radiations of meiolanoid-like turtles in southern Pangea, suggest that the horned turtles are a Triassic group and that the dichotomy between Pleurodira and Cryptodira occurred well before the Late Triassic. Early Cretaceous chelids at Lightning Ridge occur at higher palaeolatitude than in South America. The temporal range of Australian chelids is extended by ~ 50 my, demonstrating that chelids had a Jurassic history in Australia, with broad diversifications across the polar supercontinent. The palaeoecological setting of Lightning Ridge is comprehensively described for the first time. Diverse invertebrates and vertebrates include terrestrial, freshwater aquatic and rare marine forms that are anomalous at this near-polar palaeolatitude (~65-70oS). The anachronistic occurrence in Early Cretaceous Australia of distinctive radiations of ‘Triassic-type’ turtles, and other relic groups, implies prolonged intervals of biogeographic isolation in the eastern provinces of Pangea.
103

Lightning-induced impulse magnetic fields in high-rise buildings

Zhou, QiBin. January 2007 (has links)
Thesis (Ph.D.)--Hong Kong Polytechnic University, 2007. / Adviser: Yaping Du. Includes bibliographical references.
104

Electromagnetic and optical characteristics of lightning measured in the earth's ionosphere /

Barnum, Benjamin Heath. January 1999 (has links)
Thesis (Ph. D.)--University of Washington, 1999. / Vita. Includes bibliographical references (p. [150]-158 ).
105

Impulse impedance of grounding systems and its effect on tower crossarm voltage : a dissertation presented to the faculty of the Graduate School, Tennessee Technological University /

Manna, Tapan K., January 2006 (has links)
Thesis (Ph.D.)--Tennessee Technological University, 2006. / Bibliography: leaves 164-169.
106

Υπολογισμός επικίνδυνων τάσεων επαφής λόγω πλήγματος κεραυνού σε κατασκευή (πρότυπο IEC 62305)

Μηλιώνη, Ευσταθία 27 December 2010 (has links)
Σκοπός της παρούσας διπλωματικής εργασίας είναι ο υπολογισμός των επικίνδυνων τάσεων επαφής σε μια κατασκευή μετά από πλήγμα κεραυνού και των αντίστοιχων συνιστωσών κινδύνου σύμφωνα με το πρότυπο IEC 62305. Στο πρώτο κεφάλαιο γίνεται μια σύντομη αλλά απαραίτητη θεωρητική ανάλυση του φαινομένου του κεραυνού. Δίνονται επίσης κάποια στοιχεία για την επίδραση του ηλεκτρικού ρεύματος στον άνθρωπο για να φανεί η σπουδαιότητα της αντικεραυνικής προστασίας. Περιγράφονται οι βασικές αρχές της αντικεραυνικής προστασίας και οι στάθμες των συστημάτων αντικεραυνικής προστασίας. Στη συνέχεια αναλύονται οι διάφορες περιπτώσεις ανάπτυξης επικίνδυνων τάσεων επαφής σε μια κατασκευή και οι μέθοδοι προστασίας που επιβάλλονται από τα διεθνή πρότυπα για την προστασία των ατόμων. Οι πιθανές συνέπειες των τάσεων επαφής και οι απώλειες που μπορεί ανά προκαλέσουν αναλύονται στο επόμενο κεφάλαιο. Στο δεύτερο κεφάλαιο αναλύεται σύντομα το πρότυπο IEC 62305 ,το οποίο εισάγει την έννοια των συνιστωσών κινδύνου σαν εργαλείο για τη μελέτη αναγκαιότητας συστήματος αντικεραυνικής προστασίας για μια κατασκευή. Το πρότυπο ορίζει τέσσερις πηγές βλαβών , τρεις τύπους βλαβών και τέσσερις κατηγορίες απωλειών. Σύμφωνα με αυτούς τους ορισμούς εκφράζει όλους τους πιθανούς κινδύνους σε μια κατασκευή λόγω πλήγματος κεραυνού με συνιστώσες κινδύνου. Κάθε συνιστώσα εκφράζεται ως γινόμενο των επικίνδυνων συμβάντων ετησίως επί την πιθανότητα βλάβης επί την επακόλουθη απώλεια. Οι όροι αυτής της εξίσωσης αναλύονται διεξοδικά για όλες τις συνιστώσες κινδύνου. Επίσης δίνονται οι αλγόριθμοι λήψης αποφάσεων για την εγκατάσταση συστήματος αντικεραυνικής προστασίας και την αξιολόγηση κόστους-αποτελεσματικότητας. Για να γίνει αυτό εκτός από το συνολικό κίνδυνο ορίζεται, σύμφωνα πάντα με το πρότυπο IEC 62305,ο αποδεκτός κίνδυνος για κάθε κατασκευή. Εκτός από τη θεωρητική διερεύνηση και τη μελέτη του προτύπου αναπτύχθηκε λογισμικό αξιολόγησης επικινδυνότητας (Risk Assessment Manager).Το πρόγραμμα υλοποιήθηκε στο Visual Studio 2008 με τη γλώσσα προγραμματισμού Visual Basic 2008, μια απ’ τις πιο δημοφιλείς γλώσσες καθοδηγούμενες από συμβάντα(event driven). Η γλώσσα αυτή επέτρεψε το σχεδιασμό ενός γραφικού περιβάλλοντος φιλικού προς το μηχανικό, ο οποίος δε χρειάζεται να είναι εξοικειωμένος με πρότυπο. Αρκεί να εισάγει τα βασικά χαρακτηριστικά της κατασκευής και στη συνέχεια να επιλέξει από λίστα επιλογών τις ρυθμίσεις που ταιριάζουν σε κάθε κατασκευή. Το πρόγραμμα δίνει επίσης τη δυνατότητα στο μηχανικός να χωρίσει την κατασκευή σε ζώνες να αποθηκεύσει και να αναζητήσει προηγούμενες μελέτες. Στο τρίτο κεφάλαιο αναλύεται ο τρόπος εισαγωγής των δεδομένων και η παρουσίαση των αποτελεσμάτων μέσω εικόνων(screenshots).Δίνεται επίσης παράδειγμα αξιολόγησης κινδύνου για κτίριο γραφείων με τρεις ζώνες(χώρος γραφείων), χώρος διακομιστών (servers) και στάθμευσης. Αρχικά γίνεται μελέτη της κατασκευής χωρίς αντικεραυνική προστασία και στη συνέχεια εφαρμόζονται συνδυασμοί μέτρων αντικεραυνικής προστασίας. Φαίνονται έτσι οι δυνατότητες που δίνει το πρόγραμμα για εύκολο υπολογισμό των συνιστωσών κινδύνου με ρύθμιση διαφόρων παραμέτρων. Στο τελευταίο κεφάλαιο παρουσιάζονται τα συμπεράσματα που προέκυψαν από αυτή τη διπλωματική εργασία και προτείνονται βελτιώσεις που θα μπορούσε να περιλαμβάνει η δεύτερη έκδοση του προγράμματος. Στο Παράρτημα δίνεται ο κώδικας του προγράμματος. Αποτελείται από τον κώδικα για τα 3 παράθυρα της εφαρμογής και για τις 3 μονάδες(module) οι οποίες περιλαμβάνουν τις απαραίτητες για την εφαρμογή συναρτήσεις. / The subject of this essay is the calculation of hazardous touch voltages inside a structure after a lightning strike according to international standard IEC 62305. First chapter is a brief but essential theoretical approach on the lightning phenomenon. The effects of electrical current to human bodies are also briefly analyzed in order to point out the importance of lightning protection. The fundamentals of lightning protection are stated, as well as the level of it as defined from the international standards. At the end of the first chapter the various scenarios of the development of touch voltages in a structure after a lightning strike are developed. The possible consequences and losses of these voltages are discussed in the next chapter. The second chapter is a thorough study of the international standard IEC 62305 and introduces the risk assessment method and the calculation of risk components for structures. The standard defines four (4) possible sources of damage, three (3) possible types of damage and 4 possible types of losses. Based on this categorization all risk components can be expressed. Each risk component can be expressed as a product of the number of annual dangerous event, of the probability of damage of a structure and of the consequent loss. The terms of this equation are thoroughly explained and calculated as well as the procedures for evaluating the need of a lightning protection system and the cost-effectiveness of the protection measures. For this study to be complete the tolerable risk for each type of loss is introduced. Along with the writing of this essay a computer program (Risk Assessment Manager) was developed. The program calculates the risk to a structure due to a lightning strike according to IEC 62305 and was written in Visual Basic 2008, one of the most popular event-driven program languages. The use of Visual Basic 2008 permitted the development of a utility friendly to users not familiar with the standard IEC 62305.The user has to insert the basic attributes of the structure and then choose from a variety of advanced characteristics of the structure. The program also allows the division of the structure to more than one zone, to save and load older studies. At the third chapter the way the program works is examined with the use of screenshots. A case study of a three zone structure (offices, server’s room and parking) is presented. Initially the risks of the structure without lightning protection are calculated and then different types of measures are applied. In the last chapter results are examined and conclusions are extracted and presented. Further optimizations on the code are discussed leading to possible, future software’s improvement. The code of the program consisting of 3 Window’s Forms and 3 modules including various functions is appended in the annex of the thesis.
107

Μελέτη των παραμέτρων του κεραυνού σε πληγέν κτίριο

Μπελεκούκιας, Ιωάννης 19 July 2012 (has links)
Το θέμα της παρούσας πτυχιακής εργασίας είναι η Μελέτη των παραμέτρων του κεραυνού σε πληγέν κτίριο. Πριν αναλυθούν οι επιπτώσεις του κεραυνού στο κτίριο είτε αυτό έχει αντικεραυνική προστασία είτε όχι, με την βοήθεια μαθηματικών μοντέλων, πρέπει να γίνει εκτενής αναφορά σε έννοιες αναγκαίες ως προς την κατανόηση των ατμοσφαιρικών ηλεκτρικών φαινομένων και ειδικότερα του κεραυνού. Έτσι στο πρώτο μέρος της εργασίας γίνεται εκτενής αναφορά και περιγραφή των ηλεκτρικών ατμοσφαιρικών φαινομένων και τον τρόπο που δημιουργείται ηλεκτρικό φορτίο στην ατμόσφαιρα. Στην συνέχεια γίνεται αναφορά και περιγραφή στο τρόπο με το οποίο φορτίζεται το σύννεφο και γενικότερα στην ηλεκτρική συμπεριφορά του για να φθάσουμε στην ανάλυση του κεραυνού. Στην προσπάθεια ανάλυσης των κεραυνών επιχειρείται η περιγραφή της φυσικής των κεραυνών, του ρεύματος του οποίου έχει και των σχετικών παραμέτρων που τον διέπουν, καθώς και της συχνότητας με την οποία συμβαίνουν οι κεραυνοί, χαρακτηριστικό το οποίο είναι πολύ σημαντικό για την μελέτη της αντικεραυνικής προστασίας ενός κτιρίου. Επίσης στην συνέχεια της εργασίας αναφέρονται οι τρόποι προσδιορισμού της ζώνης προστασίας ενός κτιρίου. Στο τελευταίο μέρος χρησιμοποιώντας το πρόγραμμα MATLAB (και συγκεκριμένα το γραφικό περιβάλλον Simulink) θα γίνει προσομοίωση του πλέγματος προστασίας για το υπό μελέτη κτίριο στον υπολογιστή. Για την μοντελοποίηση θα πρέπει να καθοριστούν η μορφή του ρεύματος που εισέρχεται στην κατασκευή λόγω του κεραυνού, το μοντέλο κάθε ράβδου και της συνολικής κατασκευής, καθώς και οι τιμές των ηλεκτρικών παραμέτρων. / This thesis attends to analyze the parameters of lightning in a directly stricken building. Before analyzing the effects of lightning in the building either has lightning protection or not, with the help of mathematical models, should be made extensive reference to concepts necessary to understand the atmospheric electrical phenomena and especially the lightning. So the first part of this thesis is a detailed report and description of electrical atmospheric phenomena and the way that electric charge generated in the atmosphere. The following sections discuss and describe the way in which the cloud is charged and the general electrical behavior of it, to get to the analysis of lightning. In the effort to analyze the lightning, is attempted describing the physics of lightning, the power which has and the relevant parameters that it has and the frequency with which lightings occur, a feature which is very important for the study of a building lightning protection. Also this thesis tries to describe methods of public buildings protection, the way they are placed and how we determine the buffer zone of a building. In the final part using the program MATLAB (namely the graphical Simulink) we will simulate the grid protection for the building under study in the computer. For modeling should specify the form of electricity entering the building due to lightning, the model of each bar and the overall design and the values of electrical parameters.
108

Μέτρηση και έλεγχος γειώσεως συστημάτων αντικεραυνικής προστασίας στα κτίρια του Πανεπιστημίου Πατρών

Χαραλαμπόπουλος, Ανδρέας 09 January 2012 (has links)
Γείωση είναι η αγώγιμη σύνδεση ενός σημείου κάποιου κυκλώματος ή ενός μη ¬ρευματοφόρου μεταλλικού αντικειμένου μιας εγκατάστασης με το έδαφος, με σκοπό να αποκτήσουν το ίδιο δυναμικό με τη γη, το οποίο θεωρείται -κατά σύμβαση-ίσο με μηδέν. Σκοπός του συστήματος γείωσης είναι να επιτυγχάνει την απαγωγή και διάχυση του κεραυνικού ρεύματος ή ρευμάτων βραχυκύκλωσης μέσα στη γη, με ταχύτητα και ασφάλεια, χωρίς να δημιουργούνται επικίνδυνες υπερτάσεις στον περιβάλλοντα χώρο, που δύνανται να πλήξουν τον άνθρωπο, καθώς και να προκαλέσουν ανεπανόρθωτες βλάβες στον εξοπλισμό. Η απόδοση των συστημάτων γείωσης που υπόκεινται σε κρουστικά ρεύματα διαδραματίζει σημαντικό ρόλο στην ασφαλή και αξιόπιστη λειτουργία ενός συστήματος ηλεκτρικής ενέργειας. Η συμπεριφορά της αντικεραυνικής προστασίας των κτιρίων, σχετίζεται με τα κρουστικά χαρακτηριστικά των διατάξεων γείωσης. Αντικείμενο της παρούσης διπλωματικής εργασίας αφορά τον έλεγχο και μέτρηση γειώσεων συστημάτων αντικεραυνικής προστασίας των προκατασκευασμένων κτιρίων , του μουσείου και άλλων επιλεγμένων κτιρίων του πανεπιστήμιου Πατρών. Στο Πρώτο Κεφάλαιο γίνεται περιγραφή κάποιων εισαγωγικών εννοιών σχετικά με τα μεγέθη του κεραυνού, τα είδη των κεραυνών, τον υπολογισμό της συχνότητας κεραυνικών πληγμάτων αλλά και τις επιπτώσεις που έχουν στις κατασκευές και στην ανθρώπινη ζωή. Στο Δεύτερο Κεφάλαιο γίνεται μια εισαγωγή στην έννοια της γείωσης, η εξοικείωση του αναγνώστη με βασικούς ορισμούς, αναφέρονται οι μέθοδοι γείωσης, οι τύποι των ηλεκτροδίων ενώ στη συνέχεια παρουσιάζονται τα κύρια χαρακτηριστικά μεγέθη που σχετίζονται με την απόκριση ενός συστήματος γείωσης. Στο Τρίτο κεφάλαιο γίνεται εκτενής αναφορά στην θεμελιακή γείωση η οποία παρουσιάζει αρκετά πλεονεκτήματα σε σχέση με άλλους τύπους γείωσης όπως είναι το χαμηλό κόστος, η χαμηλή τιμή αντίστασης αλλά και η ευελιξία που παρέχει αφού μπορεί να χρησιμοποιηθεί και για γείωση ΣΑΠ λαμβάνοντας υπόψη τις πρόσθετες ειδικές απαιτήσεις σύμφωνα με τα προτυπο ΕΛΟΤ EN 62305-3:2006 και το διεθνές IEC 62305-3:2006. Στο Τέταρτο κεφάλαιο παρουσιάζεται ο σχεδιασμός ενός Συστήματος Αντικεραυνικής Προστασίας (ΣΑΠ). Αρχικά γίνεται μια περιγραφή τον ενεργών διατάξεων σύλληψης κεραυνών ενώ στη συνέχεια αναφέρονται αναλυτικά όλα τα στάδια που απαιτούνται για την εγκατάσταση ενός ΣΑΠ . Στο Πέμπτο Κεφάλαιο παραθέτονται οι πίνακες με τις μετρήσεις και τις συνθήκες που επικρατούσαν κατά την διάρκεια των μετρήσεων καθώς και τα σημεία που μετρηθήκαν πάνω στην κάτοψη των κτιρίων . Η εργασία περατώνεται με την αναφορά συμπερασμάτων και τις βιβλιογραφικές αναφορές από όπου άντλησα το υλικό μου . / Grounding is the conductive connection of a circuit’s point, or of a non-current carrying metallic object of an installation to the ground, in order to obtain the same potential as the earth, which is, by convention, equal to zero. The purpose of the grounding system is to successfully carry off and diffuse the lightning current or short-circuit currents into the earth, quickly and safely, without causing dangerous overvoltages in the surrounding area, which can affect humans, and cause irreparable damages to the equipment . The performance of grounding systems subjected to impulse currents, play an important role in safe and reliable operation of a power system. The behavior of lightning protection of buildings, associated with impact characteristics of grounding arrangements. The subject of this study is the control and measurement of earthing systems, lightning protection of prefabricated buildings, the museum and other selected buildings in the University of Patras. The first chapter contains a description of some import concepts on sizes of lightning, types of lightning, calculating the frequency of lightning shocks and their effects on structures and human life. The second chapter is an introduction to the concept of grounding, to familiarize the reader with basic definitions, referred to the grounding methods, types of electrodes and then present the main featured items associated with the response of a grounding system. The third chapter is extensively referred to the foundational ground which presents several advantages over other types of ground such as low cost, low resistance value and the flexibility provided, that can be used for grounding LPS with the additional specific requirements in accordance with the standard ELOT EN 62305-3:2006 and international IEC 62305-3:2006. The fourth chapter presents the design of a lightning protection system (LPS). At the start there is a description of the active devices capture lightning and then details all the steps required to install an LPS. In the fifth chapter are given the tables of measurements and conditions prevailed during the measurements and the points measured on the layout of buildings. The work ends with the report conclusions and bibliographical references from which I draw my material.
109

Aspectos de compatibilidade eletromagnética em estruturas atingidas por descargas atmosféricas

SARTORI, CARLOS A.F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:00Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:21Z (GMT). No. of bitstreams: 1 12436.pdf: 2191865 bytes, checksum: 12b10ebed00b6647c2de939f5f567b1d (MD5) / Tese (Doutoramento) / IPEN/T / Escola Politecnica, Universidade de Sao Paulo - POLI/USP
110

Aspectos de compatibilidade eletromagnética em estruturas atingidas por descargas atmosféricas

SARTORI, CARLOS A.F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:00Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:21Z (GMT). No. of bitstreams: 1 12436.pdf: 2191865 bytes, checksum: 12b10ebed00b6647c2de939f5f567b1d (MD5) / Tese (Doutoramento) / IPEN/T / Escola Politecnica, Universidade de Sao Paulo - POLI/USP

Page generated in 0.0812 seconds