• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Identificação, mensuração e localização tridimensional de descargas parciais em transformadores de potência com base em resultados de ensaios de emissão acústica / Identification, measurement and three-dimensional location of partial discharges in power transformers based on test results of acoustic emission

Romualdo, Hudson de Paula 27 February 2014 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2015-01-13T11:11:37Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação - Hudson de Paula Romualdo - 2014.pdf: 9811768 bytes, checksum: 55fffa80c94a94773bc7fe8059f4bbc2 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-01-13T11:11:53Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação - Hudson de Paula Romualdo - 2014.pdf: 9811768 bytes, checksum: 55fffa80c94a94773bc7fe8059f4bbc2 (MD5) / Made available in DSpace on 2015-01-13T11:11:53Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação - Hudson de Paula Romualdo - 2014.pdf: 9811768 bytes, checksum: 55fffa80c94a94773bc7fe8059f4bbc2 (MD5) Previous issue date: 2014-02-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / The presence of partial discharges in power transformer represents a relevant indicator of incipient failure. Partial Discharges are lightning quick and incomplete, intermittent, that in power transformers can be detected by means of some methods, among them, the test of acoustic emission. Currently, the algorithms used by equipment that processes the information from testing of acoustic emission are owners, and thus not available for the scientific community. Still, it is usually not performed the separation of noise detected from partial discharge of the other noises in the results, and little information about the dynamics of the occurrence of noise is presented. In this work, are presented three methods, identification, measurement and three-dimensional location, that foster the development of a computational solution for the diagnosis of power transformers using data derived from testing of acoustic emission with focus on the occurrence of partial discharges, phenomenon harmful to the appropriate functioning of the equipment. After a substantiation based on literature review of the issues dealt with in the course of the study, are described methods for identification of noises coming only from partial discharges, among the total noise (of all kinds), and measurement of these noises and their attributes (already done in a separate manner). Then, reference-if the method for three-dimensional location and, finally, expose-if the results of the application of the methods developed in the form of a case study showing the benefits of the application of the methods described here. Thus Demonstrating the importance of their results in supporting the decision-making process and, consequently, in maintaining the operational condition of power transformers. / A presença de descargas parciais no transformador de potência representa um relevante indicador de falha incipiente. Descargas parciais são descargas elétricas incompletas, rápidas e intermitentes, que em transformadores de potência podem ser detectadas através de alguns métodos, dentre eles, o ensaio de emissão acústica. Atualmente, os algoritmos utilizados pelos equipamentos que processam as informações provenientes de ensaios de emissão acústica são proprietários, não sendo assim, disponibilizados para a comunidade científica. Ainda, normalmente, não é realizada a separação do ruído detectado proveniente de descarga parcial dos demais ruídos nos resultados, e pouca informação sobre a dinâmica da ocorrência dos ruídos é apresentada. Neste trabalho, são apresentados três métodos, identificação, mensuração e localização tridimensional, que fomentam a elaboração de uma solução computacional para o diagnóstico de transformadores utilizando-se dados provenientes dos ensaios de emissão acústica com foco na ocorrência de descargas parciais, fenômeno nocivo ao adequado funcionamento do equipamento. Após uma fundamentação com base na análise bibliográfica dos assuntos abordados ao longo do trabalho, são descritos métodos para identificação dos ruídos provenientes somente de descargas, dentre o ruído total (de toda natureza), e mensuração desses ruídos e seus atributos (já realizado de forma separada). Em seguida, referencia-se o método para a localização tridimensional e, finalmente, expõem-se os resultados da aplicação dos métodos desenvolvidos na forma de um estudo de caso evidenciando os benefícios da aplicação dos métodos aqui descritos. Demonstrando assim a importância de seus resultados no suporte à tomada de decisão e, consequentemente, na manutenção da condição operacional de transformadores de potência.
2

Análise do microfissuramento em rochas no ensaio de compressão diametral por meio da técnica de emissão acústica / Analysis of microcracking in rocks in diametral compression tests through the acoustic emission technique

Rodríguez Saavedra, Patricia Carolina Alejandra 08 December 2015 (has links)
Em nível microscópico, as rochas apresentam microdefeitos que agem como concentradores locais de tensão, favorecendo a ocorrência de ruptura frágil. O entendimento desse processo requer análises experimentais em rochas submetidas a tensões de tração. O ensaio de compressão diametral é uma alternativa apropriada, pois não apresenta as dificuldades envolvidas no ensaio de tração direta. A propagação de microfissuramento em materiais frágeis produz liberação de energia na forma de ondas elásticas chamadas de emissões acústicas (EA). O monitoramento com EA permite acompanhar a propagação de dano no corpo de prova (CP), sem perturbá-lo. Nesta pesquisa, CPs de mármore e monzogranito são submetidos a ensaios de compressão diametral com deslocamentos monotônicos e cíclicos, com controle de deslocamento. Aplica-se a técnica de EA, em conjunto com análises petrográficas, análises das curvas de força versus deslocamento e exame visual, para caracterizar o seu processo de microfissuramento. A localização tridimensional das fontes de EA foi realizada inicialmente utilizando-se o software AEwin® da PASA. Foi desenvolvido um programa de localização aprimorado que incorpora o cálculo da velocidade de propagação das ondas (vp) média para cada instante em que uma fonte é localizada. O novo programa (Crack Location by Acoustic emission with P Wave Velocity determination, CLAPWaVe) mostra um claro decréscimo da velocidade de propagação com o aumento do dano. O programa desenvolvido (CLAPWaVe) mostrou melhor ajuste e maior coerência com a literatura e com a condição final rompida dos CPs do que o software AEwin. Em mármore e monzogranito o microfissuramento se inicia a 25-30% e 75-85% do carregamento de pico, respectivamente, e localiza-se na vizinhança do centro do CP. Em ambas as rochas se acumulou, também, dano na região dos apoios do CP, associado à transferência de carregamento do berço ao CP. Antes do pico de carregamento, o microfissuramento tornou-se mais denso e localizado no centro e nos apoios do CP, embora a região central ainda concentre a maior parte. Após o pico, o microfissuramento acumulou-se em uma das faces do CP, progredindo até a outra face. O monzogranito apresentou ruptura progressiva do CP, enquanto que no mármore a maior parte da superfície de ruptura já está desenvolvida imediatamente após o pico. Durante o ensaio em ambas as rochas, no núcleo central foram registradas as menores velocidades vp do CP. Na região dos apoios, embora tenha havido microfissuramento, registraram-se as maiores velocidades vp no CP, pois o confinamento produzido pelo contato com o berço aumentou localmente a rigidez do CP. A distribuição não homogênea de vp no CP revelou que a consideração desse parâmetro como constante e igual à condição intacta ao longo do ensaio, como comumente encontrado na literatura, não representa a condição real do CP danificado. O microfissuramento no monzogranito se propaga principalmente através dos cristais de quartzo, seguindo um caminho tortuoso subparalelo à direção de carregamento e liberando altos níveis de energia absoluta. No mármore, a propagação segue os planos de clivagem da calcita, liberando níveis baixos de energia absoluta. Os histogramas da distribuição espacial da resistência em ambas as rochas mostraram bom ajuste a uma distribuição de Weibull, porém o monzogranito mostrou melhor ajuste e menor variabilidade que o mármore. As análises dos sinais no domínio das frequências mostraram que o microfissuramento é caracterizado por emissões de banda larga. / At microscopic level, rocks exhibit microflaws, which act as local stress concentrators, favoring the occurrence of brittle failure. The understanding of this process requires experimental analyses of rock specimens under tensile stresses. The diametral compression test is an adequate alternative for such a studies, because it does not present the difficulties of direct tension tests. Crack propagation in brittle materials releases energy as transient elastic waves known as acoustic emission (AE). Monitoring with AE enables an insight into the cracking process without affecting the integrity of the sample. In this work, marble and monzogranite specimens were subjected to monotonic and cyclic displacementcontrolled diametral compression tests. The AE monitoring technique was applied in conjunction with petrographic analyses, interpretation of the load versus displacement curves and visual examination of the samples for the characterization of their cracking process. The three-dimensional localization of the AE sources was initially carried out by using the software AEwin® from PASA. An improved localization software, which considers the P-wave velocity variation along the damage process (vp) for each AE source was developed. The developed software (Crack Location by Acoustic emission with P Wave Velocity determination, CLAPWaVe) has shown greater consistency with literature and the final cracked samples and better accuracy than AEwin. Microcracking in monzogranite and marble initiated at 25-30% and 75-80% of the peak load, respectively, and is located at the center of the specimen. In addition, both rocks showed concentrated microcracking close to the region of contact between the specimen and the loading platens, related to the loading transference along the loading edge. Before peak load, microcracking becomes denser and localized at the center and the contact region of the specimen, although, the central region still concentrates the main portion of the damage. After the peak load, new microcracks were first concentrated on one of the faces at the center of the specimen and then propagated through its thickness all the way to the other face. The progressive failure in monzogranite extended through to the end of the test, while in marble the main portion of the failure surface of the specimen developed just after peak. During the whole test in both rocks, the lowest velocities (vp) of the specimen were recorded in the central core. Although microcracking was induced at the contact region, the highest velocities vp of the specimen were registered there, because of the confinement effect produced by the platens, which lead to a local increase in the stiffness of the specimen. The non-homogeneous distribution of vp in the specimen has revealed that the utilization of this parameter as a constant and equal to the value measured in the specimen before testing (as usually adopted in the literature), does not represent the real condition of the damaged specimen. In monzogranite, microcracks propagate mainly through quartz crystals, following a tortuous path subparallel to the loading direction, by releasing high-level of absolute energy, while in marble the propagation of microcracks follows the cleavage planes of calcite, by releasing low-level of absolute energy. The histograms of spatial strength distribution in both rocks have shown good adjustment to a Weibull distribution, but monzogranite exhibited a more accurate adjustment with lower variability than marble. The analysis of signals in the frequency domain showed that the microcracking is characterized by wide band emissions.
3

Análise do microfissuramento em rochas no ensaio de compressão diametral por meio da técnica de emissão acústica / Analysis of microcracking in rocks in diametral compression tests through the acoustic emission technique

Patricia Carolina Alejandra Rodríguez Saavedra 08 December 2015 (has links)
Em nível microscópico, as rochas apresentam microdefeitos que agem como concentradores locais de tensão, favorecendo a ocorrência de ruptura frágil. O entendimento desse processo requer análises experimentais em rochas submetidas a tensões de tração. O ensaio de compressão diametral é uma alternativa apropriada, pois não apresenta as dificuldades envolvidas no ensaio de tração direta. A propagação de microfissuramento em materiais frágeis produz liberação de energia na forma de ondas elásticas chamadas de emissões acústicas (EA). O monitoramento com EA permite acompanhar a propagação de dano no corpo de prova (CP), sem perturbá-lo. Nesta pesquisa, CPs de mármore e monzogranito são submetidos a ensaios de compressão diametral com deslocamentos monotônicos e cíclicos, com controle de deslocamento. Aplica-se a técnica de EA, em conjunto com análises petrográficas, análises das curvas de força versus deslocamento e exame visual, para caracterizar o seu processo de microfissuramento. A localização tridimensional das fontes de EA foi realizada inicialmente utilizando-se o software AEwin® da PASA. Foi desenvolvido um programa de localização aprimorado que incorpora o cálculo da velocidade de propagação das ondas (vp) média para cada instante em que uma fonte é localizada. O novo programa (Crack Location by Acoustic emission with P Wave Velocity determination, CLAPWaVe) mostra um claro decréscimo da velocidade de propagação com o aumento do dano. O programa desenvolvido (CLAPWaVe) mostrou melhor ajuste e maior coerência com a literatura e com a condição final rompida dos CPs do que o software AEwin. Em mármore e monzogranito o microfissuramento se inicia a 25-30% e 75-85% do carregamento de pico, respectivamente, e localiza-se na vizinhança do centro do CP. Em ambas as rochas se acumulou, também, dano na região dos apoios do CP, associado à transferência de carregamento do berço ao CP. Antes do pico de carregamento, o microfissuramento tornou-se mais denso e localizado no centro e nos apoios do CP, embora a região central ainda concentre a maior parte. Após o pico, o microfissuramento acumulou-se em uma das faces do CP, progredindo até a outra face. O monzogranito apresentou ruptura progressiva do CP, enquanto que no mármore a maior parte da superfície de ruptura já está desenvolvida imediatamente após o pico. Durante o ensaio em ambas as rochas, no núcleo central foram registradas as menores velocidades vp do CP. Na região dos apoios, embora tenha havido microfissuramento, registraram-se as maiores velocidades vp no CP, pois o confinamento produzido pelo contato com o berço aumentou localmente a rigidez do CP. A distribuição não homogênea de vp no CP revelou que a consideração desse parâmetro como constante e igual à condição intacta ao longo do ensaio, como comumente encontrado na literatura, não representa a condição real do CP danificado. O microfissuramento no monzogranito se propaga principalmente através dos cristais de quartzo, seguindo um caminho tortuoso subparalelo à direção de carregamento e liberando altos níveis de energia absoluta. No mármore, a propagação segue os planos de clivagem da calcita, liberando níveis baixos de energia absoluta. Os histogramas da distribuição espacial da resistência em ambas as rochas mostraram bom ajuste a uma distribuição de Weibull, porém o monzogranito mostrou melhor ajuste e menor variabilidade que o mármore. As análises dos sinais no domínio das frequências mostraram que o microfissuramento é caracterizado por emissões de banda larga. / At microscopic level, rocks exhibit microflaws, which act as local stress concentrators, favoring the occurrence of brittle failure. The understanding of this process requires experimental analyses of rock specimens under tensile stresses. The diametral compression test is an adequate alternative for such a studies, because it does not present the difficulties of direct tension tests. Crack propagation in brittle materials releases energy as transient elastic waves known as acoustic emission (AE). Monitoring with AE enables an insight into the cracking process without affecting the integrity of the sample. In this work, marble and monzogranite specimens were subjected to monotonic and cyclic displacementcontrolled diametral compression tests. The AE monitoring technique was applied in conjunction with petrographic analyses, interpretation of the load versus displacement curves and visual examination of the samples for the characterization of their cracking process. The three-dimensional localization of the AE sources was initially carried out by using the software AEwin® from PASA. An improved localization software, which considers the P-wave velocity variation along the damage process (vp) for each AE source was developed. The developed software (Crack Location by Acoustic emission with P Wave Velocity determination, CLAPWaVe) has shown greater consistency with literature and the final cracked samples and better accuracy than AEwin. Microcracking in monzogranite and marble initiated at 25-30% and 75-80% of the peak load, respectively, and is located at the center of the specimen. In addition, both rocks showed concentrated microcracking close to the region of contact between the specimen and the loading platens, related to the loading transference along the loading edge. Before peak load, microcracking becomes denser and localized at the center and the contact region of the specimen, although, the central region still concentrates the main portion of the damage. After the peak load, new microcracks were first concentrated on one of the faces at the center of the specimen and then propagated through its thickness all the way to the other face. The progressive failure in monzogranite extended through to the end of the test, while in marble the main portion of the failure surface of the specimen developed just after peak. During the whole test in both rocks, the lowest velocities (vp) of the specimen were recorded in the central core. Although microcracking was induced at the contact region, the highest velocities vp of the specimen were registered there, because of the confinement effect produced by the platens, which lead to a local increase in the stiffness of the specimen. The non-homogeneous distribution of vp in the specimen has revealed that the utilization of this parameter as a constant and equal to the value measured in the specimen before testing (as usually adopted in the literature), does not represent the real condition of the damaged specimen. In monzogranite, microcracks propagate mainly through quartz crystals, following a tortuous path subparallel to the loading direction, by releasing high-level of absolute energy, while in marble the propagation of microcracks follows the cleavage planes of calcite, by releasing low-level of absolute energy. The histograms of spatial strength distribution in both rocks have shown good adjustment to a Weibull distribution, but monzogranite exhibited a more accurate adjustment with lower variability than marble. The analysis of signals in the frequency domain showed that the microcracking is characterized by wide band emissions.

Page generated in 0.1313 seconds