• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Nanosondes fluorescentes pour l'exploration des pressions et des températures dans les films lubrifiants / Fluorescent nanoprobes for the exploration of pressures and temperatures in movies lubricants

Hajjaji, Hamza 14 October 2014 (has links)
L’objectif de ce travail est d’utiliser les nanoparticules (NPs) de nanosondes fluorescentes de température en particulier dans les films lubrifiants. Le développement de ces nanosondes nécessite la détermination de leurs sensibilités thermiques afin de pouvoir sélectionner les NPs les plus prometteuses. Pour atteindre cet objectif, nous avons présenté deux méthodes d’élaboration utilisées pour la synthèse des nanostructures à base de SiC-3C, la méthode d’anodisation électrochimique et la méthode d’attaque chimique. Dans le premier cas, les analyses FTIR,RAMAN et MET des NPs finales ont montré que la nature chimique de ces NPs est majoritairement formée de carbone graphitique. L’étude détaillée de la photoluminescence de ces NPs a montré que le processus d’émission dépend de la chimie de surface des NPs, du milieu de dispersion et de sa viscosité, de la concentration des suspensions et de la température du milieu. Pour la deuxième famille de NP de SiC, les analyses cohérentes MET, DLS et PL ont montrées une taille moyenne de 1.8 nm de diamètre avec une dispersion de ±0.5nm. Le rendement quantique externe de ces NPs est de l’ordre de 4%. Les NPs dispersées dans l’éthanol, n’ont pas montré une dépendance à la température exploitable pour notre application. Par contre, les NPs de SiC produites par cette voie, étant donné la distribution en taille resserrée et le rendement quantique « honorable » pour un matériau à gap indirect, sont prometteuses pour des applications comme luminophores en particulier pour la biologie grâce à la non toxicité du SiC. Dans le cas des NPs de Si, nous avons également étudié deux types différents de NPs. Il s’agit de : (i) NPs obtenues par anodisation électrochimique et fonctionnalisées par des groupements alkyls (décène, 1-octadécène). Nous avons mis en évidence pour la première fois une très importante variation de l’énergie d’émission dEg/dT avec la température de type red-shift entre 300 et 400K. Les mesures de(T) conduisent à une sensibilité thermique de 0.75%/°C tout à fait intéressante par rapport aux NPs II-VI. De plus il a été montré que la durée de vie mesurée n’est pas fonction de la concentration. (ii) NPs obtenue par voie humide et fonctionnalisées par le n-butyl. Pour ce type de NPs nous avons mis pour la première fois en évidence un comportement de type blue-shift pour dEg/dT de l’ordre de -0.75 meV/K dans le squalane. Pour ces NPs, la sensibilité thermique pour la durée de vie de 0.2%°C est inférieure à celle des NPs de type (i) mais largement supérieure à celle des NPs de CdSe de 4 nm (0.08%/°C). La quantification de cette la sensibilité à la température par la position du pic d’émission dEg/dT et de la durée de vie nous permet d’envisager la conception de nanosondes de température basée sur les NPs de Si avec comme recommandations l’utilisation de NPs obtenues par anodisation électrochimique et de la durée de vie comme indicateur des variations en température. / The goal of this study is the use of Si and SiC nanoparticles (NPs) as fluorescent temperature nanoprobes particularly in lubricating films. The development of these nanoprobes requires the determination of their thermal sensitivity in order to select the best prospects NPs. To achieve this goal, we presented two preparation methods used for the synthesis of 3C-SiC based nanostructures : (i) anodic etching method and (ii) chemical etching method. In the first case, the FTIR, Raman and TEM analysis of final NPs showed that the chemical nature of these NPs is formed predominantly of graphitic carbon. The detailed photoluminescence study of these NPs showed that the emission process depends on the surface chemistry of the NPs, the dispersion medium and its viscosity, the suspension concentration and temperature of the environment.. In the second case, coherent TEM, DLS and PL analyzes showed an average size of 1.8 nm in diameter with a dispersion of ±0.5 nm. The external quantum efficiency of these NPs is 4%. NPs dispersed in ethanol, did not show an exploitable fluorescence dependence on temperature for our application. On the other hand, 3C-SiC NPs produced by this way, given the narrow size distribution and the reasonably high quantum yield for an indirect bandgap material, are promising for applications such as luminophores in particular in the biology field thanks to nontoxicity of SiC. In the case of Si we studied also two different types of NPs. (i) NPs obtained by anodic etching and functionalized by alkyl groups (decene, octadecene). We have demonstrated for the first time an important red-shift in the emission energy dEg/dT with temperature from 300 to 400K. The PL lifetime measurement(T) lead to a thermal sensitivity of 0.75% /°C very interesting compared to II-VI NPs. Furthermore it has been shown that t is not depending on the concentration. (ii) NPs obtained by wet-chemical process and functionalized with n-butyl. For this type of NPs we have identified for the first time a blue-shift behavior of dEg dT in the order of -0.75 meV/K in squalane. The thermal sensitivity for the PL lifetime of these NPs is 0.2%/°C, which is lower than that of NPs obtained by anodic etching method, but much greater than that of CdSe NPs with 4 nm of diameter (0.08%/°C). Quantification of the temperature sensitivity by the position of emission peak dEg/dT and the PL lifetime dτ/dT allows us to consider the realization of temperature nanoprobes based on Si NPs with recommendations to use Si NPs obtained by anodic etching method and PL lifetime as an indicator of temperature changes.
2

Mapování tloušťky mazacího filmu u náhrad velkých kloubů člověka / Mapping of lubricating film thickness of human big joints replacements

Bosák, Dalibor January 2012 (has links)
This master’s thesis describes mechanism of lubricating film forming and its thickness in contact of a metal hip joint ball and a glass disc with chromium layer with presence of bovine serum as substitute of synovial fluid occured in a natural joint. Lubricating film thickness is evaluated by a thin film colorimetric interferometry, results are ploted at graphs representing dependence of lubricating film thickness on experiment duration or on mutual speed of articulating surfaces. There is described the influence of concentration of bovine serum and different kinematic conditions on lubricating film forming. From observed interferograms is apparent the adsorption of proteins to glass disc and femoral head surfaces, denaturation and formation of protein aggregations affecting the residual lubricating film thickness.
3

Experimentální studium tření a mazání TEP kyčle / Experimental study of friction and lubrication in THR

Urban, Filip January 2014 (has links)
This work analyzes problems of friction and lubrication of total hip replacement (THR). At first, experimental study of friction coefficient under various conditions was conducted using hip joint simulator based on principle of pendulum. After that, lubrication film development was observed, using colorimetric interferometry with head from THR and glass cup with respect of geometry and clearance to cups made originally for THR. With respect to research study [25] it was found that increasing contact conformity leads to increased film thickness. Also protein adsorption on articulating surfaces was observed. Thanks to adsorption 80 nm film thickness was measured even if relative surface speed was zero. Furthermore protein aggregation was observed on the border of contact zone, similar aggregations were observed by Myant et al. [29] or Vrbka et al. [25]. These aggregations are formed when lubricant is under shear stress and it can positively affect film thickness. If the relative motion of articulating surfaces is not sufficient, the protein layer can`t be refreshed enough and film thickness start decreasing. Coefficient of friction 0,13 was measured when lubricating film development was observed. Close to this value are material combinations metal on polyethylene and metal on metal.

Page generated in 0.0856 seconds