Spelling suggestions: "subject:"luminescência opticamente estimula"" "subject:"iuminescência opticamente estimula""
11 |
Validação e avaliação dosimétrica empregando as técnicas de TL e OSL de materiais termoluminescentes para aplicação na dosimetria de feixes clínicos de elétrons utilizados na irradiação total da pele - TSI / Validation and dosimetric evaluation employing the techniques of TL and OSL of thermoluminescent materials for application in the dosimetry of clinical beams of electrons used in total irradiation of the skin - TSIAlmeida, Shirlane Barbosa de 11 April 2017 (has links)
A dosimetria in vivo têm se tornado um papel importante para o tratamento da irradiação total da pele dentro de um rigoroso programa de garantia de qualidade que deve ser parte integrante nos departamentos radioterápicos. A dosimetria em TSI é difícil, devido à complexidade do tratamento em avaliar a uniformidade da dose e medir a dose absorvida em profundidades rasas em toda extensão da superfície cutânea, tendo como consequência uma ampla variação na distribuição da dose. Os TLDs tem provado ser muito úteis para a distribuição e verificação da dose prescrita para o paciente, pois a dose pode diferir de local para local devido a geometria do corpo do paciente, sobreposições de estruturas e assimetrias do campo de radiação. A utilização de TLDs in vivo pode identificar variações da dose prescrita por apresentarem uma grande exatidão e precisão nas medidas. Nos setores de radioterapia vêm sendo empregado vários tipos de dosímetros, os mais utilizados são o Flureto de Lítio (TLD-100), onde obtém uma longa história neste tipo de aplicação. Novos materiais dosímetricos vêm ganhado grande importância na aplicação da dosímetria de feixes clínicos de elétrons, como o Sulfato de Cálcio dopado com Disprósio (TL) e o Óxido de Alumínio dopado com Carbono (OSL), este trabalho avalia o desempenho dosímetrico dos respectivos dosímetros termoluminescentes e a luminescência opticamente estimulada na aplicação da dosímetria de feixes clínicos de elétrons utilizados na irradiação total da pele. / In vivo dosimetry has become an important role for the treatment of total skin irradiation within a rigorous quality assurance program that should be an integral part of the radiotherapy departments. TSI dosimetry is difficult because of the complexity of the treatment in assessing dose uniformity and measuring the dose absorbed at shallow depths throughout the skin surface extent, resulting in a wide variation in dose distribution. The TLDs have proven to be very useful for the distribution and verification of the dose prescribed for the patient as the dose may differ from place to place due to patient body geometry, overlapping of structures and asymmetries of the radiation field. The use of TLDs in vivo can identify variations in the prescribed dose because its measurement accuracy and great precision. Several types of dosimeters have been used in the radiotherapy sectors, the most commonly used are Lithium Fluride (TLD-100), where it obtains a long history in this type of application. New dosimetric materials have gained great importance in the dosimetry of clinical electron beams, such as Dysprosium-doped Calcium Sulphate (TL) and Carbon doped (OSL) based Aluminum Oxide, This work evaluates the performance of the respective thermoluminescent dosimeters and the optically stimulated luminescence in the dosimetry of clinical electron beams used in total irradiation of the skin.
|
12 |
Caracterização dosimétrica de amostras de BeO em feixes de radiação alfa, beta e X por técnicas luminescentes / Dosimetric characterization of BeO samples in alpha, beta and X radiation beams using luminescent techniquesGroppo, Daniela Piai 29 October 2013 (has links)
No campo da medicina, a radiação ionizante é utilizada tanto para fins terapêuticos como para fins diagnósticos, englobando assim um amplo intervalo de doses de diferentes tipos de radiações. Para assegurar que a finalidade da prática esteja sendo alcançada, são necessários estudos detalhados de detectores e dispositivos que respondam a diferentes tipos de radiações. Neste trabalho foi realizada a caracterização dosimétrica de amostras de BeO utilizando as técnicas de termoluminescência (TL) e luminescência opticamente estimulada (OSL) comparando-se as respostas para as radiações alfa, beta e X e propondose um sistema adequado para sua utilização em monitoração de feixes destas radiações. Dentre os principais resultados obtidos estão: alta sensibilidade à radiação beta para ambas as técnicas empregadas, boa reprodutibilidade das respostas TL e OSL (coeficientes de variação inferiores a 5%), uma dependência energética máxima da radiação X de 28% para técnica TL, e de apenas 7% para a técnica OSL, dentro dos intervalos de energia estudados. As características dosimétricas obtidas neste trabalho mostram a possibilidade de aplicação das amostras de BeO em dosimetria das radiações ionizantes X, alfa e beta, considerando os intervalos de dose empregados, pelas técnicas de TL e OSL. Pelos resultados obtidos, as amostras de BeO apresentaram sua utilização potencial para dosimetria de feixes de radiodiagnóstico e radioterapia. / In the medical field, the ionizing radiation is used both for therapeutic and diagnostic purposes, in a wide range of radiation doses. In order to ensure that the objective is achieved in practice, detailed studies of detectors and devices in different types of radiations beams are necessary. In this work a dosimetric characterization of BeO samples was performed using the techniques of thermoluminescence (TL) and optically stimulated luminescence (OSL) by a comparision of their response for alpha, beta and X radiations and the establishment of an appropriated system for use in monitoring of these radiations beams. The main results are: the high sensitivity to beta radiation for both techniques, good reproducibility of TL and OSL response (coefficients of variation lower than 5%), maximum energy dependence of the X radiation of 28% for the TL technique, and only 7% for the OSL technique, whithin the studied energy range. The dosimetric characteristics obtained in this work show the possibility of applying BeO samples to dosimetry of alpha, beta and X radiations, considering the studied dose ranges, using the TL and OSL techniques. From the results obtained, the samples of BeO showed their potential use for beam dosimetry in diagnostic radiology and radiotherapy.
|
13 |
Mudanças paleoambientais no Holoceno em lagoas salinas do Pantanal da Nhecolândia /Guerreiro, Renato Lada. January 2016 (has links)
Orientador: Mario Luis Assine / Banca: José Cândido Stevaux / Banca: Lucas Veríssimo Warren / Banca: Ivan Bergier Tavares de Lima / Banca: Francisco Sergio Bernardes Ladeira / Resumo: Foram analisados registros sedimentares, geoquímicos, micropaleontológicos e datações 14C e LOE em sedimentos recuperados de lagoas salinas em porções distintas da Nhecolândia. Os testemunhos recuperados das lagoas são compostos por areias finas a muito finas na porção inferior, que são recobertas por sedimentos organo-siltosos na porção superior. Os resultados geocronológicos revelaram que os sedimentos arenosos foram depositados do final do Pleistoceno Tardio ao Holoceno Médio-Superior, com importante descontinuidade na passagem Pleistoceno/Holoceno marcada por mudanças abruptas na coloração e coesão das areias. Os sedimentos organo-siltosos foram depositados continuamente, sem lacunas estratigráficas expressivas e são registro de tempo maior de residência de água nas lagoas a partir do Holoceno Superior em relação ao Holoceno Médio-Superior. Espículas de esponjas e frústulas de diatomáceas preservadas nos sedimentos permitiram distinguir uma fase inicial lacustre de água doce com sedimentação de areias finas a muito finas no Holoceno Médio-Superior, com posterior transição para ambientes salino-alcalinos dominados por sedimentação organo-siltosa no Holoceno Superior. As assembleias de espículas de esponjas e diatomáceas revelaram que as lagoas salinas estudadas apresentavam ambientes lacustres de água doce na maior parte do Holoceno, evidenciando que a salinidade das lagoas é decorrente de processos recentes e não herança de climas áridos do passado / Abstract: Sediment cores from saline lakes of different areas of Nhecolândia were used to assess the temporal resolution and environmental sensitivity of these aquatic ecosystems. The shallow stratigraphy of each pond is characterized by a thick basal sandy unit overlain by a thinner silt sized organic muddy. Geochronological results revealed that these sediments were deposited in different temporal contexts, whereas the sandy sediments were deposited from the Late Pleistocene to the Mid-to-Late Holocene, with significant discontinuity between Pleistocene and Holocene marked by abrupt changes in the color and cohesion of the sands. The organic muddy sediments was continuously deposited on the Late Holocene without significant stratigraphic gaps. We interpret patterns of organic sediments accumulation to reflect a longer water residence time on the Late Holocene. Sponge spicules and diatoms frustules assemblages showed that the saline ponds had lacustrine environments of freshwater in most of the Mid-Late Holocene, suggesting that salinity of lakes is due to recent processes and not inheritance of past arid climates / Doutor
|
14 |
Metodologia dosimétrica para extremidades em indivíduos ocupacionalmente expostos à radiação beta por meio da técnica de luminescência opticamente estimulada / Dosimetric methodology for extremities of individuals occupationally exposed to beta radiation using the optically stimulated luminescence techniqueTeresa Cristina Nathan Outeiro Pinto 27 July 2010 (has links)
Uma metodologia dosimétrica foi estabelecida, para determinação das doses recebidas em extremidades por indivíduos ocupacionalmente expostos à radiação beta, com detectores de Al2O3:C e sistema leitor microStar, da Landauer, associados à técnica de luminescência opticamente estimulada (OSL). As principais etapas do trabalho foram: caracterização do material dosimétrico Al2O3:C utilizando a técnica de OSL; estabelecimento de um método para avaliação de dose em extremidades; determinação de taxas de dose de fontes de radiação beta; aplicação do método estabelecido em um teste prático com indivíduos ocupacionalmente expostos à radiação beta durante uma simulação de procedimento de calibração de aplicadores clínicos; validação do método desenvolvido por meio de comparação das doses obtidas no teste prático pela técnica de OSL com doses obtidas pela técnica de TL. Os resultados mostram que os detectores de Al2O3:C e a técnica de OSL podem ser utilizados em monitoração individual de extremidades e radiação beta. / A dosimetric methodology was established for the determination of extremity doses of individuals occupationally exposed to beta radiation, using Al2O3:C detectors and the optically stimulated luminescence (OSL) reader system microStar, Landauer. The main parts of the work were: characterization of the dosimetric material Al2O3:C using the OSL technique; establishment of the dose evaluation methodology; dose rate determination of beta radiation sources; application of the established method in a practical test with individuals occupationally exposed to beta radiation during a calibration simulation of clinical applicators; validation of the methodology by the comparison between the dose results of the practical test using the OSL and the thermoluminescence (TL) techniques. The results show that both the OSL Al2O3:C detectors and the technique may be utilized for individual monitoring of extremities and beta radiation.
|
15 |
Caracterização dosimétrica de amostras de BeO em feixes de radiação alfa, beta e X por técnicas luminescentes / Dosimetric characterization of BeO samples in alpha, beta and X radiation beams using luminescent techniquesDaniela Piai Groppo 29 October 2013 (has links)
No campo da medicina, a radiação ionizante é utilizada tanto para fins terapêuticos como para fins diagnósticos, englobando assim um amplo intervalo de doses de diferentes tipos de radiações. Para assegurar que a finalidade da prática esteja sendo alcançada, são necessários estudos detalhados de detectores e dispositivos que respondam a diferentes tipos de radiações. Neste trabalho foi realizada a caracterização dosimétrica de amostras de BeO utilizando as técnicas de termoluminescência (TL) e luminescência opticamente estimulada (OSL) comparando-se as respostas para as radiações alfa, beta e X e propondose um sistema adequado para sua utilização em monitoração de feixes destas radiações. Dentre os principais resultados obtidos estão: alta sensibilidade à radiação beta para ambas as técnicas empregadas, boa reprodutibilidade das respostas TL e OSL (coeficientes de variação inferiores a 5%), uma dependência energética máxima da radiação X de 28% para técnica TL, e de apenas 7% para a técnica OSL, dentro dos intervalos de energia estudados. As características dosimétricas obtidas neste trabalho mostram a possibilidade de aplicação das amostras de BeO em dosimetria das radiações ionizantes X, alfa e beta, considerando os intervalos de dose empregados, pelas técnicas de TL e OSL. Pelos resultados obtidos, as amostras de BeO apresentaram sua utilização potencial para dosimetria de feixes de radiodiagnóstico e radioterapia. / In the medical field, the ionizing radiation is used both for therapeutic and diagnostic purposes, in a wide range of radiation doses. In order to ensure that the objective is achieved in practice, detailed studies of detectors and devices in different types of radiations beams are necessary. In this work a dosimetric characterization of BeO samples was performed using the techniques of thermoluminescence (TL) and optically stimulated luminescence (OSL) by a comparision of their response for alpha, beta and X radiations and the establishment of an appropriated system for use in monitoring of these radiations beams. The main results are: the high sensitivity to beta radiation for both techniques, good reproducibility of TL and OSL response (coefficients of variation lower than 5%), maximum energy dependence of the X radiation of 28% for the TL technique, and only 7% for the OSL technique, whithin the studied energy range. The dosimetric characteristics obtained in this work show the possibility of applying BeO samples to dosimetry of alpha, beta and X radiations, considering the studied dose ranges, using the TL and OSL techniques. From the results obtained, the samples of BeO showed their potential use for beam dosimetry in diagnostic radiology and radiotherapy.
|
16 |
Caracterização dosimétrica do BeO em feixes de radiodiagnóstico convencional, mamografia e tomografia computadorizada, pelas técnicas de termoluminescência e luminescência opticamente estimulada / Dosimetric characterization of BeO in standard beams of conventional diagnostic radiology, mammography and computed tomography, by the thermoluminescence and optically stimulated luminescence techniquesFábio Junqueira Algarve 18 August 2017 (has links)
A radiação ionizante é amplamente utilizada em diversas áreas na indústria e na medicina. No campo da medicina, a radiação ionizante é utilizada tanto para fins terapêuticos como para fins diagnósticos, abrangendo assim um grande intervalo de doses de diferentes tipos de radiações. Para certificar que a finalidade da prática esteja sendo alcançada, são necessários estudos detalhados de detectores e dispositivos que atendam aos diferentes tipos de radiações. Neste trabalho foi realizado um estudo das características dosimétricas de amostras de BeO em feixes padronizados de radiodiagnóstico convencional, mamografia e tomografia computadorizada, utilizando as técnicas de termoluminescência (TL) e luminescência opticamente estimulada (OSL) e propondo um sistema adequado para sua utilização em dosimetria de feixes. Os principais resultados obtidos foram: alta sensibilidade à luz branca durante a irradiação, boa reprodutibilidade das respostas TL e OSL (coeficientes de variação inferiores a 5%), parâmetros cinéticos correspondentes aos valores obtidos em todos os métodos testados, sem fading dentro do período estudado para ambas as técnicas. As características dosimétricas obtidas neste trabalho mostram a possibilidade de aplicação das amostras de BeO em dosimetria da radiação X, considerando os intervalos de dose empregados, pelas técnicas de TL e OSL. Assim, as amostras de BeO apresentaram sua utilização potencial para dosimetria de feixes de radiodiagnóstico convencional, mamografia e tomografia computadorizada. / The ionizing radiation is widely used in several areas in industry and medicine. In the field of medicine, the ionizing radiation is used both for therapeutic purposes and for diagnostic purposes, thus covering a wide range of doses of different types of radiation. To certify that the goal of practice is being achieved detailed studies of detectors and devices that respond to different types of radiation are required. In this work, a study of dosimetric characteristics of BeO samples was performed in standard beams of conventional diagnostic radiology, mammography and computed tomography, using the techniques of thermoluminescence (TL) and optically stimulated luminescence (OSL), and proposing a suitable system for its use in beam dosimetry. The main results obtained were: high sensitivity to white light during the irradiation, good reproducibility of responses TL and OSL (coefficients of variation of less than 5%), and kinetics parameters corresponding to the values obtained in all of the tested methods, without fading within the observed period for both techniques. The dosimetric characteristics obtained in this work show the possibility of application of BeO samples for dosimetry of X radiation, considering the tested dose interval, by the TL and OSL techniques. Thus, the BeO samples presented potential use for dosimetry of conventional diagnostic radiology, mammography and computed tomography beams.
|
17 |
Variações da zona de convergência intertropical e do nível relativo do mar durante o Quaternário tardio registradas em depósitos eólicos do Nordeste e Norte do Brasil / not availableZular, André 22 December 2016 (has links)
Os sistemas eólicos na região dos Lençóis Maranhenses no Maranhão, da costa oriental do Rio Grande do Norte e do médio Rio Branco, norte da Amazônia em Roraima, estão sob ação direta da zona de convergência intertropical (ZCIT) As variações da ZCIT controlam a intensidade dos ventos e chuvas nessas regiões, importantes forçantes na dinâmica desses sistemas eólicos, os quais são representados principalmente por campos de dunas Nos campos de dunas do Maranhão e Rio Grande do Norte, adiciona-se a ação das variações do nível relativo do mar (NRM), que afetam a disponibilidade de sedimentos e o nível freático da planície costeira, que por sua vez influenciam a construção e estabilização dunar Depósitos eólicos dunares dessas três áreas foram selecionados para investigar a ação de forçantes climáticas e do NRM na sedimentação eólica durante o Pleistoceno tardio e Holoceno Para tanto, foi utilizada datação por luminescência oticamente estimulada (optically stimulated luminescence, OSL) associada a análises sedimentológicas e geoquímicas de alta resolução em perfis de sucessão de paleodunas Isto permitiu a identificação de períodos de atividade e estabilização do sistema eólico O registro dos Lençóis Maranhenses abrange o último ciclo glacial, com sedimentos eólicos depositados de 132,20 ± 7,00 ka mil anos atrás) até 12,90 ± 0,60 ka Nele, se detecta períodos de formação de dunas durante NRM decrescente e baixo A preservação desses registros entre aproximadamente 71 a 13 ka está relacionada a períodos de maior precipitação durante os eventos Heinrich, quando houve migração persistente da ZCIT para o sul Já o registro do Rio Grande do Norte abrange o período de 78,98 ± 8,30 ka até 0,06 ± 0,01 ka e indica a formação de campos de dunas também em condições de NRM decrescente e baixo, além de campo de dunas formado sob linha de costa transgressiva e clima predominantemente úmido favorecido pela última fase de subida do NRM, entre o último máximo glacial e o Holoceno médio O estudo no Rio Grande do Norte destaca também a influência dos campos de dunas na fisiografia costeira, onde a interação fluvio-eólica proporcionou a formação de lagoas (Lagoa do Boqueirão) no Holoceno Médio Por sua vez, os depósitos eólicos de Roraima abrangem o período de 21,9 ± 1,00 ka até 1,10 ± 0,10 ka e registram o desenvolvimento de campo de dunas a partir de areias do médio Rio Branco, com maior taxa de construção dunar entre o último máximo glacial (23 ka) e o evento climático Heinrich 1 (15 ka), quando a incidência de ventos fortes e pluviosidade reduzida nas baixas latitudes do hemisfério norte estão relacionadas a persistente migração ao sul da ZCIT Os registros dos campos de dunas do MA e RN e RR produzem assim um notável arquivo do efeito das variações da ZCIT e do NRM nos sistemas eólicos das regiões nordeste e norte do Brasil durante o Pleistoceno tardio e Holoceno / Eolian sand deposits in the region of the Lençóis Maranhenses in Maranhão, the eastern coast of Rio Grande do Norte, and the Middle Branco River, north of the Amazon in Roraima, are under direct influence of the intertropical convergence zone (ITCZ) . ITCZ fluctuations control wind intensity and rains in these regions, important forcings controlling the dynamics of eolian systems, that are mainly represented by dunefields In the coastal dunefields of Maranhão and Rio Grande do Norte, an additional forcing is the relative sea level (RSL), that affects the availability of sediments and controls the water table level of the coastal plain, that in turn influence the construction and stabilization of dunes Eolian sand deposits in these three areas were selected to investigate the effects of climate and RSL forcings on construction and stabilization of dunes during the late Pleistocene and Holocene using optically stimulated luminescence dating (OSL) associated with sedimentological and geochemical analysis from high-resolution sampling of paleodune succession profiles. The Lençóis Maranhenses record encompasses the last glacial cycle, with eolian sand accumulation from 132.20 ± 7.00 ka (thousand years ago) to 12. 90 ± 0. 60 ka This paleoenvironmental archive shows periods of dune construction during falling and low RSL. The preservation of these records between approximately 71-13 ka is related to periods of greater precipitation during Heinrich events, when there were persistent southbound shifts of the ITCZ The record of the Rio Grande do Norte dunefield from 78.98 ± 8.30 to 0.06 ± 0.01 ka also indicates the formation of dunefields under falling and low RSL in addition to transgressive dunefields formed under rising RSL and wetter climate during the last phase of the deglaciation in the late Holocene. The study in Rio Grande do Norte also highlights fluvialOeolian interplay that affected coastal physiography and promoted the formation of the Boqueirão Lake in the middle Holocene In turn, the eolian sand deposits of Roraima record accumulation from 21.9 ± 1.00 to 1.10 ± 0.10 ka from Branco River reworked sands In Roraima, the highest rate of dune construction was between the last glacial maximum (23 ka) and the Heinrich 1 climate event (15 ka), at times of high winds and low rainfall at low latitudes of the northern hemisphere related to persistent southward migration the ITCZ. The dunefield record from Maranhão, Rio Grande do Norte and Roraima thus provide a remarkable archive of the effects of the variations of the ITCZ and RSL in eolian deposits in the northeast and north regions of Brazil during the late Pleistocene and Holocene
|
18 |
Geomorfologia e cronologia dos depósitos da planície fluvial no Alto curso do rio Paraná, MS/SP /Oliveira, Stefania Cristino de. January 2018 (has links)
Orientador: Mario Luis Assine / Coorientador: Fabiano do Nascimento Pupim / Banca: José Cândido Stevaux / Banca: Edvard Elias de Souza Filho / Resumo: O conhecimento da evolução geomorfológica da planície fluvial do rio Paraná, no trecho a montante da barragem de Porto Primavera, é ainda precário, visto que a maioria dos trabalhos publicados sobre este curso fluvial teve como foco o trecho a jusante da represa. Neste contexto, o objetivo desse estudo foi investigar a sucessão de eventos geológicos responsáveis pela evolução e configuração atual do sistema fluvial do Alto rio Paraná, no trecho entre as Usinas Hidrelétricas de Jupiá e Porto Primavera (divisa entre os Estados de São Paulo e Mato Grosso do Sul). Dados de sensoriamento remoto, sedimentológicos, geocronológicos e perfis topobatimétricos foram utilizados para o desenvolvimento da pesquisa. Quatro compartimentos geomorfológicos foram identificados sendo que três destes compartimentos foram datados: Unidade 1, terraço elevado com presença de lagoas circulares e semicirculares; Unidade 2, terraço intermediário com pequenas lagoas e áreas encharcadas (idade LOE de 60.532 ± 6.068 anos); Unidade 3, terraço baixo com paleocanais preservados (idade LOE de 39.774 ± 2.798 anos); e Unidade 4, planície fluvial atual (idade LOE de 8.884 ± 1.576 anos). As unidades geomorfológicas definidas foram correlacionadas com unidades de trabalhos anteriores localizadas a jusante da área estudada. A Unidade 1, Unidade 3 e Unidade 4 são consideradas extensões das unidades geomorfológicas Taquaruçu, Fazenda Boa Vista e Rio Paraná, respectivamente. A Unidade 2 é um compartimento com caracter... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The knowledge of the geomorphological evolution of the Paraná River fluvial plain in the stretch upstream of the Porto Primavera dam is still precarious, since most of the published works on this fluvial course focused on the stretch downstream of the dam. In this context, the objective of this study was to investigate the succession of geological events responsible for the evolution and current configuration of the river system of the Upper Paraná River, between the Jupiá and Porto Primavera Hydroelectric Plants (between the States of São Paulo and Mato Grosso do Sul). Remote sensing data, sedimentological, geochronological and topobatimetric profiles were used for the development of the research. Four geomorphological compartments were identified and three of these compartments were dated: Unit 1, raised terrace with circular and semi-circular ponds; Unit 2, intermediate terrace with small ponds and soaked areas (OSL age from 60,532 ± 6,068 years); Unit 3, low terrace with preserved paleo canals (OSL age from 39,774 ± 2,798 years); and Unit 4, current fluvial plain (OSL age from 8.884 ± 1.576 years). The defined geomorphological units were correlated with units of previous works located downstream of the studied area. Unit 1, Unit 3 and Unit 4 are considered extensions of the geomorphological units Taquaruçu, Fazenda Boa Vista and Rio Paraná, respectively. Unit 2 is a compartment with unique morphological characteristics, therefore, not correlated with units presented in pr... (Complete abstract click electronic access below) / Mestre
|
19 |
Validação e avaliação dosimétrica empregando as técnicas de TL e OSL de materiais termoluminescentes para aplicação na dosimetria de feixes clínicos de elétrons utilizados na irradiação total da pele - TSI / Validation and dosimetric evaluation employing the techniques of TL and OSL of thermoluminescent materials for application in the dosimetry of clinical beams of electrons used in total irradiation of the skin - TSIShirlane Barbosa de Almeida 11 April 2017 (has links)
A dosimetria in vivo têm se tornado um papel importante para o tratamento da irradiação total da pele dentro de um rigoroso programa de garantia de qualidade que deve ser parte integrante nos departamentos radioterápicos. A dosimetria em TSI é difícil, devido à complexidade do tratamento em avaliar a uniformidade da dose e medir a dose absorvida em profundidades rasas em toda extensão da superfície cutânea, tendo como consequência uma ampla variação na distribuição da dose. Os TLDs tem provado ser muito úteis para a distribuição e verificação da dose prescrita para o paciente, pois a dose pode diferir de local para local devido a geometria do corpo do paciente, sobreposições de estruturas e assimetrias do campo de radiação. A utilização de TLDs in vivo pode identificar variações da dose prescrita por apresentarem uma grande exatidão e precisão nas medidas. Nos setores de radioterapia vêm sendo empregado vários tipos de dosímetros, os mais utilizados são o Flureto de Lítio (TLD-100), onde obtém uma longa história neste tipo de aplicação. Novos materiais dosímetricos vêm ganhado grande importância na aplicação da dosímetria de feixes clínicos de elétrons, como o Sulfato de Cálcio dopado com Disprósio (TL) e o Óxido de Alumínio dopado com Carbono (OSL), este trabalho avalia o desempenho dosímetrico dos respectivos dosímetros termoluminescentes e a luminescência opticamente estimulada na aplicação da dosímetria de feixes clínicos de elétrons utilizados na irradiação total da pele. / In vivo dosimetry has become an important role for the treatment of total skin irradiation within a rigorous quality assurance program that should be an integral part of the radiotherapy departments. TSI dosimetry is difficult because of the complexity of the treatment in assessing dose uniformity and measuring the dose absorbed at shallow depths throughout the skin surface extent, resulting in a wide variation in dose distribution. The TLDs have proven to be very useful for the distribution and verification of the dose prescribed for the patient as the dose may differ from place to place due to patient body geometry, overlapping of structures and asymmetries of the radiation field. The use of TLDs in vivo can identify variations in the prescribed dose because its measurement accuracy and great precision. Several types of dosimeters have been used in the radiotherapy sectors, the most commonly used are Lithium Fluride (TLD-100), where it obtains a long history in this type of application. New dosimetric materials have gained great importance in the dosimetry of clinical electron beams, such as Dysprosium-doped Calcium Sulphate (TL) and Carbon doped (OSL) based Aluminum Oxide, This work evaluates the performance of the respective thermoluminescent dosimeters and the optically stimulated luminescence in the dosimetry of clinical electron beams used in total irradiation of the skin.
|
20 |
Evolução geomorfológica e mudanças paleo-hidrológicas na porção sul do Pantanal : a planície interleques do rio Negro e leques fluviais coalescentes /Merino, Eder Renato. January 2016 (has links)
Orientador: Mario Luis Assine / Banca: José Candido Stevaux / Banca: Francisco Sergio Bernardes Ladeira / Banca: Antonio Conceição Paranhos Filho / Banca: Lucas Veríssimo Warren / Resumo: O Pantanal é uma das maiores áreas alagáveis do planeta cuja dinâmica de inundação e o aporte sedimentar dos rios são os principais agentes que controlam a evolução de suas paisagens. Até o momento, as pesquisas sobre o trato deposicional moderno da Bacia do Pantanal têm se concentrado na planície tronco do rio Paraguai e nos sistemas de megaleques. Todavia, pouco tem-se realizado nas planícies interleques que são importantes áreas de captação e distribuição de águas e sedimento dos sistemas distributivos coalescentes. A planície interleque do rio Negro, limitada ao norte pelos megaleques do Taquari e do Negro e ao sul pelos megaleques do Aquidauana, Taboco e Miranda, constitui umas das principais áreas de captação da porção sul do Pantanal. A fim de compreender a evolução da planície interleques do rio Negro e sua interação com os sistemas deposicionais adjacentes foram conduzidos estudos geomorfológicos e hidrossedimentológicos a partir da integração de dados orbitais, sedimentológicos e geocronológicos. Também foram realizados estudos sobre a geomorfologia do megaleque do rio Aquidauana, um dos únicos grandes sistemas da borda sul sem estudos sistemáticos. Com isso buscou-se identificar, mapear e caracterizar de forma integrada os principais registros de mudanças paleo-hidrológicas na porção sul da bacia. Imagens de satélite e modelos digitais de elevação foram utilizados na compartimentação geomorfológica e na identificação de mudanças paleo-hidrológicas. Levantamento da ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The Pantanal wetland, in central-west Brazil, is one of largest seasonally flooded freshwater wetlands in the globe, with unique landscapes and a hotspot for wildlife, being rivers flood dynamics and its sediment load major agents in the landscape evolution. Until now, researches about the basin modern alluvial tract are focused on the Paraguay river trunk plain and on the megafan systems. Nonetheless, little has been done in interfan plains that are important areas of catchment and distribution of water and sediment from the coalescing distributary systems. The Negro river interfan plain, bordered to the north by the Taquari and the Negro and to the south by the Aquidauana, Taboco and Miranda, is one of the main catchment area of the Pantanal. In order to understand the evolution of the Negro rive interfan plain and its interaction with the adjacent depositional systems were performed geomorphological and hydrosedimentological studies based on the integration of orbital, sedimentological and geochronological data. Studies were also conducted on the Aquidauana megafan, one of the only major systems of the southern border without geomorphological studies. Thus, it was possible to identify, map and characterize the major records of paleohydrological changes in the southern portion of the basin in an integrated way. Satellite imagery and digital elevation models were used on the geomorphological zonation and for identifying paleohydrological changes. Survey of river discharge ... (Complete abstract click electronic access below) / Doutor
|
Page generated in 0.1574 seconds