• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Design, development, and validation of specific methods to assess the biological performances of degradable metals for cardiovascular stents

Purnama, Agung 23 April 2018 (has links)
Les métaux biodégradables (MBs) ont été développés pour des applications spécifiques dans les domaines de l’orthopédie, la pédiatrie et le système cardiovasculaire. Les MBs sont conçus pour servir de support temporaire et une fois que leur présence n’est plus nécessaire, ils devront disparaitre progressivement grâce au processus de corrosion. Ces dernières décennies, divers tests aussi bien in vitro que in vivo ont été effectués dans le but de comprendre le comportement à la corrosion des biomatériaux métalliques conçus pour être résistants à la corrosion. Les MBs forment une classe de matériaux relativement nouveau et donc rares sont les tests effectués dans le domaine. Les tests effectués pour améliorer la résistance à la corrosion des biomatériaux métalliques ne peuvent pas non plus être simplement transposés aux MBs. Dans certains cas, ils peuvent être adaptés avec quelques modifications tandis que dans d’autres, la dégradation progressive devra être prise en compte pour la conception et à la mise au point de tests spécifiques. Le défi actuel est de savoir comment évaluer la réaction des tissus environnants et des organes en présence des produits de dégradation. Dans le cadre de ce projet, nous avons exploré une nouvelle méthode qui permet d’établir le profil d’expression des gènes (PEG) des cellules fibroblastique 3T3 de souris exposées à l’alliage Fe-35Mn. Cet alliage de fer récemment développé comme matériau métallique dégradable a été utilisé dans le cadre de cette expérience pour mieux comprendre le comportement des cellules face à des MBs potentiellement cytotoxiques. En résumé, les cellules 3T3 ont étés exposées pendant 24h aux élutions de produits de dégradation à travers un filtre de culture cellulaire contenant des quantités cytostatiques de 3.25mg/ml pour Fe-35Mn en poudre, 0.25mg/ml de poudre de Mn pur ou 5mg/ml de poudre de fer pur. Le profil de l’expression des gènes a été établi pour ces cellules. En comparant l’expression du profil des gènes des cellules fibroblastes 3T3 en présence de Fe-35Mn et Mn, nous avons observé que l’expression de 68 gènes avait été augmentée et l’expression de 54 gènes abaissée. Nous avons testé chez 11 gènes modulés dans les « microarrays » si cette régulation était toujours présente en utilisant le RT-PCR quantitative. C’était le cas pour 10 d’entre eux. Nous avons constaté que la caveoline-1 (cav1), une protéine structurale de caveoles (invaginations lisses de la membrane plasmique), est l’un des gènes les plus régulés de notre GEPs. Nous avons par ailleurs étudié le potentiel d’utiliser cette protéine de 22KDa comme biomarqueur pour l’étude de la cytotoxicité lors de l’exposition aux MBs. Dans le but de mieux caractériser l’expression de la cav1 dans ce contexte, les cellules 3T3 ont étés exposés soit aux ions fer ou manganèse à des concentrations cytostatiques pendant 24h et 48h. L’expression de la cav1 n’a pas été influencée par l’exposition aux ions fer. Par contre l’exposition aux ions manganèse réduit l’expression des gènes de cav1 de 30% pendant 24h et de plus de 65% pendant 48h comparée au control. La contenu en protéin de la cav1 a également été réduit de façon semblable Le même phénomène a été observé pour la cav3 (le sous-type musculaire de la caveoline) dans cette étude. Cette tendance forte et reproductible de la régulation des cavéolines permet ainsi de le considérer comme un biomarqueur potentiel pour les MBs. Ce type de réponse de la caveoline à l’exposition des MBs est similaire chez les cellules endothéliales, fibroblastes et musculaires. / Biodegradable metals (BMs) have been introduced and proposed for some specific applications including cardiovascular applications. BMs are expected to undergo ‘auto-withdrawal’ through corrosion process after fulfilling structural support. In the past decades, a wide and complete set of in vitro and in vivo tests have been proposed and investigated for the conventional corrosion resistant metallic biomaterials--but not for the BMs. The same tests that the ones developed for corrosion-resistant metals cannot be simply transposed. They can be adapted in some cases while in some others progressive degradation should inspire and lead to the design and the development of new specific tests. The current challenge is how to assess the tolerance of surrounding tissues to the presence of degradation products. In this doctoral project, a new method to investigate BMs was explored by establishing the gene expression profile (GEP) of mouse 3T3 fibroblasts exposed to Fe-35Mn, recently developed iron-based alloy, in order to better understand cell response to potentially cytotoxic BMs. Briefly, 3T3 cells were exposed to degradation products eluting through tissue culture insert filter containing cytostatic amounts of 3.25 mg/ml of Fe-35Mn powder, 0,25 mg/ml of pure Mn powder or 5 mg/ml of pure iron powder for 24 hours. GEP was then conducted from these cells. When comparing the GEP of 3T3 fibroblasts in presence of Fe-35Mn and Mn, 68 up-regulated and 54 down-regulated genes were common. These results were confirmed by quantitative RT-PCR for a subset of these genes. It was found that caveolin-1 (cav1), the structural protein of caveolae little plasma membrane smooth invaginations present in various differentiated cell types, was one of the most down-regulated genes in our GEPs. We further studied the potential of this 22kDa protein to become a biomarker for cytotoxicity towards the exposure of BMs. In order to better characterize cav1 expression in this context, 3T3 mouse fibroblasts were exposed to either ferrous and manganese ions at a cytostatic concentrations for 24 or 48 hours. Cav1 gene expression was not influenced by exposition to ferrous ions. On the other hand, manganese exposure for 24 hours reduced cav1 gene expression by about 30% and > 65% at 48 hours compared to control 3T3 cells. Cav1 cellular protein content was also reduced to the same extent. The same pattern of expression for cav3 (the muscle specific caveolin subtype) was also observed in the study. This strong and reproducible pattern of regulation of caveolins thus exhibits a potential as a biomarker for the toxicity of BMs.
2

Étude des mécanismes de dégradation par méthode électrochimique de métaux biodégradables pour leur utilisation dans les voies urinaires

Champagne, Sébastien January 2018 (has links)
Au Canada, jusqu’à cinq adultes sur 10 000 vont souffrir de trouble de l’obstruction des voies urinaires, une maladie du système urinaire qui contribuait, en 2008, au fardeau économique du Canada à une hauteur de 3,8 milliards de dollars. Pour soulager le patient, les urologues devront ouvrir les voies urinaires de façon mécanique à l’aide d’une endoprothèse. Idéalement, cette endoprothèse permettra l’écoulement de l’urine sans obstruction, sera résistante à la calcification et sera biodégradable. Les métaux biodégradables ont le potentiel pour la création de ce type d’endoprothèse. Ce potentiel a été partiellement établi dans ce projet en évaluant les propriétés de dégradation de plusieurs métaux (Mg pur, Mg-2Zn-1Mn, Zn pur, Zn-0,5Mg, Zn-1Mg et Zn-0,5Al) à l’aide de techniques électrochimiques dans l’urine artificielle à 37 °C et par voie de techniques avancées de caractérisation de surface. Basés sur la technique de polarisation, les métaux du groupe du Mg montrent une vitesse de dégradation plus rapide que le groupe du Zn. Il en ait de même avec le bruit électrochimique jusqu’à 12h d’inversion. Ensuite, l’inverse est obtenu. Du point de vue de l’impédance, le groupe du Mg montre une seule constante de temps alors qu’il y en a deux pour le groupe du Zn. En microscopie électronique, le groupe du Mg montre une couche d’oxyde non uniforme alors que pour le groupe du Zn, il y a formation de produit de dégradation en forme de fleur, sauf pour le Zn-0,5Al. L’analyse de surface confirme que les produits de corrosion sont composés majoritairement d’hydroxyde, de carbonate et de phosphate, de plus les métaux du groupe du Zn sont dépourvus de calcium. Parmi tous les métaux étudiés, l’alliage Zn-0,5Al présente une couche d’oxyde uniforme et possède peu d’affinité avec les ions présents dans l’urine artificielle, ce qui fait de lui le candidat le plus intéressant par sa faible tendance à la calcification. / In Canada, up to five in 10 000 adults suffered from acute urinary tract obstruction, a kidney-related disease that contributes to the economy burden of Canada by $3.8 billion in 2008. Urologists mechanically open the obstructed urinary tract using a stent which ideally maintains an excellent urine flow, be resistant to infection and encrustation, and be biodegradable. Biodegradable metals could have the potential for making this ideal ureteral stent. This potential was partially assessed in this work by conducting detailed electrochemical corrosion tests in artificial urine at 37°C and advanced surface characterization on biodegradable pure Mg, Mg-2Zn-1Mn, pure Zn, Zn-0.5Mg, Zn-1Mg and Zn-0.5Al alloys. Based on polarization measurement, the Mg group was found to exhibit a faster corrosion rate than the Zn group, but then experienced a slow down at longer period of immersion as indicated by electrochemical noise measurement. The impedance of the Mg group surfaces showed a one-time constant behaviour with low double layer capacitance compared to the two-time constant of those of the Zn group. The SEM observation showed the formation of non-uniform corrosion layer on the Mg group and the formation of flower-like precipitates on the surface of the Zn group except for Zn-0.5Al alloy. The EDS and XPS analysis confirmed the main composition of corrosion layer as hydroxide, carbonate and phosphate, without calcium content for the Zn group. Among all tested metals, the Zn-0.5Al alloy exhibits the most interesting behavior by showing a uniform corrosion layer with low affinity to the ions in the artificial urine, indicating a low tendency to encrustation.

Page generated in 0.0715 seconds