• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Exposition aux bactéries environnementales dans l’habitat : méthodes de mesure et impacts sur la santé des occupants / Exposure to the environmental bacteria in the housing environment : methods of measure and impacts on the health of the occupants

Guenoune, Yanis 21 December 2017 (has links)
La qualité de l’air des environnements intérieurs est essentielle pour la santé. Le manque de renouvellement d’air et l’humidité dans les habitats favorise la prolifération microbienne. Les effets sur la santé sont multiples et souvent associés à des maladies chroniques respiratoires, tel que l’asthme. Ces effets sont plus ou moins graves selon le niveau d’exposition et la vulnérabilité des occupants et le rôle des moisissures est pointé. Cependant, le manque d’outils valides permettant d’évaluer quantitativement l’exposition aux bactéries environnementales constitue une des principales difficultés pour mieux appréhender leur impact sur la santé humaine. Un protocole expérimental basé sur les techniques culturales a été développé et testé au laboratoire pour mesurer la survie des bactéries dans des poussières domestiques collectées au sol. L’analyse de ces poussières a permis de déterminer le temps de survie des bactéries testées. Cependant, les méthodes culturales actuelles sont limitées et n’apportent pas assez d’informations sur la composition de la flore bactérienne dans l’habitat. L’utilisation des méthodes moléculaires, tel que le séquençage haut débit, est nécessaire pour y remédier. Par ailleurs, les poussières domestiques pourraient constituer un substrat intégrateur de l’exposition chronique des occupants. Outre le développement, la standardisation, et la validation d’outils de mesure, une approche globale de sensibilisation et de prévention du risque d’exposition aux contaminants des environnements intérieurs est recommandée, en particulier chez les populations vulnérables. / Indoor air quality is essential for health. Lack of ventilation and presence of humidity in habitats promotes microbial growth. The health effects are multiple and often associated with chronic respiratory diseases, such as asthma. These effects are more or less serious depending on the level of exposure and the vulnerability of occupants and the role of mold is pointed out. However, the lack of valid tools for quantitatively assessing exposure to environmental bacteria is one of the main difficulties in better understanding their impact on human health. An experimental protocol based on cultural techniques was developed and tested in the laboratory to measure the survival of bacteria in domestic dust collected on the ground. The analysis of these dusts made it possible to determine the survival time of the bacteria tested. However, current culture methods are limited and do not provide enough information on the composition of the bacterial flora in the habitat. The use of molecular methods, such as high throughput sequencing, is needed to address this. In addition, domestic dust could be an integrating substrate for chronic occupant exposure. In addition to the development, standardization, and validation of measurement tools, a comprehensive approach to raising awareness and preventing the risk of indoor exposure to contaminants is recommended, particularly for vulnerable populations.
2

Étude et modélisation des perturbations produites au sein des microcontrôleurs STM32 soumis à des stress en impulsion / Study and modelling of the disturbances produced within the STM32 microcontrollers under pulsed stresses

Bacher, Yann 27 April 2017 (has links)
La fiabilité des microcontrôleurs est cruciale compte tenu de leur utilisation massive dans de nombreux domaines, surtout dans des environnements sévères. De ce fait, la robustesse aux perturbations électromagnétiques, en particulier à propos des alimentations, est un axe de développement majeur, que ce soit pour acquérir un avantage comparatif sur le marché, ou simplement pour assurer la sécurité des biens et des personnes. En ce sens, nous avons étudié le test de ces circuits soumis à des agressions transitoires rapides en salve définies par la norme IEC 61000-4-4. Les mécanismes spécifiques de propagation de la perturbation en mode commun sont mis en évidence, ainsi que leur conversion en mode différentiel. Plusieurs méthodes de mesure, dont certaines originales, ont été développées pour valider cette conversion, ainsi que les modes de propagation. Sur cette base, le réseau de distribution des alimentations a été particulièrement étudié et son influence sur la robustesse du circuit a été mise en évidence. Enfin, cette thèse ouvre de nouvelles perspectives d’amélioration de la robustesse des microcontrôleurs, pour ce type d’agression, et donc de leur fiabilité. / The reliability of the microcontrollers is crucial considering their massive use in numerous domains, especially in severe environments. Therefore, the robustness in the electromagnetic disturbances, in particular for the power supply network, is a major development, whether it is to acquire a comparative advantage on the market, or simply to assure the goods and people safety. Therefore, we studied the Fast Transient Burst test of integrated circuits, as defined by the IEC 61000-4-4 standard. The specific propagation mechanisms of the disturbance in common mode are highlighted, as well as their conversion in differential mode. Several measurements methods, among which certain novel, were developed to validate this conversion, as well as the propagation modes. Based on this, the power distribution network was particularly studied and its influence on the robustness of the circuit was highlighted. Finally, this work opens new perspectives of improvement of the microcontrollers’ robustness, for this kind of aggression, and thus their reliability.

Page generated in 0.0795 seconds