• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Escoamento no interior de um dispositivo centrifugo utilizado em circulação extracorporea

Barbosa, Marcos Pinotti 11 November 1996 (has links)
Orientador: Eugenio Spano Rosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-22T03:47:07Z (GMT). No. of bitstreams: 1 Barbosa_MarcosPinotti_D.pdf: 44752191 bytes, checksum: 4001ae207eef045165cfeee88edbd4e8 (MD5) Previous issue date: 1996 / Resumo: A falta de informação básica sobre os mecanismos responsáveis pela hemólise mecânica impede, na maioria dos casos, o uso adequado da bomba centrífuga. Visando a preencher esta lacuna, este trabalho foi conduzido de modo a se estudarem as estruturas básicas do escoamento no interior de uma bomba centrífuga e relacioná-las a um potencial de hemólise. Foram empregadas duas abordagens distintas: simulação numérica de um canal isolado dabomba, com o objetivo de compreender a interação entre as forças inerciais, viscosas e de pressão em diversas situações operacionais, e medição experimental do campo de velocidade nos canais internos da bomba, com a finalidade de se obter uma visão global do escoamento e da interação entre os diferentes canais. O desafio do método numérico foi resolver as equações do movimento escritas em coordenadas ortogonais generalizadas a partir da formulação de fluxo de tensão. O programa computacional foi implementado em FORTRAN, empregando um algoritmo baseado no método dos volumes finitos. As medidas de velocidade foram realizadas por um sistema de anemômetro laser Doppler de última geração, capaz de medir duas componentes simultâneas de velocidade. Desenvolveu-se um protocolo experimental que superou os principais obstáculos associados ao acesso óptico às regiões de interesse no interior da bomba e à similaridade entre as condições de testes e as fisiológicas. A contribuição deste trabalho foi o desenvolvimento de uma metodologia de análise que relaciona as estruturas básicas do escoamento ao potencial de danos às células vermelhas do sangue / Abstract: The lack of basic information about the performance of mechanical hemolysis severely affects centrifugal blood pump handling. The present work faced this problem by studying the flow structures and the way hemolytic potential is influenced by them. Two distinct approaches were employed: numerical simulation of a single channel of the pump, in order to understand the interaction of inertial, viscous and pressure forces in different operational situations, and non-invasive measurements of the velocity field to provide a general picture of the flow field as well as the interaction between the flow generated by each channeI. Solving the Momentum equations, that were written in generalized orthogonal coordinates, using the stress-flux formulation, was the challenge of the numerical method. The computational program was devised by employing the finite volume method and it was implemented in FORTRAN language. The velocity measurements were performed by a laser Doppler anemometer system capable of acquiring and processing two simultaneous orthogonal velocity components. Difficulties arising ftom the optical access to the regions of interest inside the pump and from the similitude between testing and phisiological conditions were overcome by the experimental protocol specially designed for non-intrusive velocity measurements. The main contribution of the present study concems the development of a specific methodology which provides the link between the flow structures and the potential damage to the red blood cells / Doutorado / Termica e Fluidos / Doutor em Engenharia Mecânica

Page generated in 0.535 seconds