• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • Tagged with
  • 16
  • 16
  • 16
  • 12
  • 12
  • 12
  • 10
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo de dosimetria gel polimérica em radioterapia com feixes de elétrons utilizando ressonância magnética e simulação Monte Carlo / Study of polymer gel dosimetry in Radiotherapy with electron beams using magnetic resonance imaging and Monte Carlo simulation.

Pianoschi, Thatiane Alves 03 February 2014 (has links)
Radioterapia com feixe de elétrons tem sido empregada, frequentemente, para tratamentos de neoplasias superficiais, devido às características de alcance bem definido e alto gradiente de dose em pouca profundidade. Para que as novas técnicas radioterápicas com esse tipo de feixe possam ser implementadas com segurança é necessária a realização de um controle da qualidade rigoroso. Protocolos recomendam que o controle da qualidade para esse tipo de feixe seja realizado com câmara de ionização, porém dosímetros termoluminescentes, diodos e filmes também são empregados com essa finalidade. Entretanto, esses dosímetros não possuem simultaneamente um conjunto de características essenciais para realização do controle da qualidade, como alta resolução espacial, baixa dependência energética, possibilidade de uso em altos gradientes de dose e distribuição tridimensional de dose. Nesse trabalho avaliou-se a utilização do dosímetro polimérico MAGIC-f gel em aplicações em controle da qualidade em Radioterapia com feixes de elétrons. As leituras das amostras de gel foram realizas por ressonância magnética e simulação Monte Carlo foi utilizada para comparação dos resultados. Como parte de um controle da qualidade para feixe de elétrons, foram determinados parâmetros dosimétricos, como perfil de dose e porcentagem de dose em profundidade, e fatores de qualidade do feixe, como R50, em condições de referência e para campos pequenos. Da comparação entre os dados clínicos e MAGIC-f as diferenças máximas encontradas foram de 4%. Além disso, distribuições de dose de aplicações clínicas com feixes de elétrons foram avaliadas pelo método de comparação do índice gama. Considerando os critérios de 3% e 3 mm, os resultados obtidos para o índice gama mostraram concordâncias acima de 94% para os métodos dosimétricos utilizados. Dessa forma, de acordo com as medidas dosimétricas realizadas com o dosímetro MAGIC-f gel conclui- se que a dosimetria polimérica gel pode ser empregada como uma ferramenta auxiliar em procedimentos de controle da qualidade em Radioterapia com feixes de elétrons, assim como uma ferramenta na determinação das distribuições tridimensionais de dose para feixe de elétrons. / Electron beam radiotherapy has been used frequently for treatments of superficial tumors, due its characteristics of well-defined range and high dose gradient at low depth. For new radiotherapy techniques with this type of beam, a strict quality control is necessary for a safe implementation. Protocols recommend that the quality control for electron beams must be performed with an ionization chamber. However, thermoluminescent dosimeters, films and diodes are also used for this purpose. Although, these dosimeters do not have a set of essential characteristics for performing quality control, like high spatial resolution, low energy dependence, possibility of use in high dose gradients and three dimensional dose distribution acquisition. The present work evaluated the use of MAGIC-f gel dosimeter for the quality control in radiotherapy with electron beams. The readings of the gel samples were made by magnetic resonance imaging and Monte Carlo simulation was used to compare the obtained results. As part of a quality control for the electron beam parameters as percentage depth dose and beam profile were determined. Also beam quality factors, such as R50, were calculated in reference conditions and for small fields. The obtained results were compared with clinical data and MAGIC-f the maximum obtained difference was 4%. In addition, dose distributions from clinical applications with electron beams were evaluated by the gamma index. Considering the criteria of 3% DD and 3 mm DTA, the results showed concordance greater than 94% for all dosimetric methods. Thus, according to the dosimetric measurements through MAGIC-f gel dosimeter it can be inferred that the gel dosimeter can be used as auxiliary tool in the quality control procedures in radiotherapy to electron beam. Also, MAGIC-f is a useful a tool to determine tridimensional dose distributions of electron beam.
2

Dosimetria gel no controle de qualidade tridimensional em tratamento de radioterapia com intensidade modulada e técnica SMART (Simultaneous Modulated Accelerated Radiation Therapy) / Gel Dosimetry in Tridimensional Quality Control Radiotherapy Treatments with Intensity Modulated and SMART Technique (Simultaneous Modulated Accelerated Radiation Therapy).

Acurio, Erick Sebastian Rundo 28 November 2016 (has links)
A radioterapia com intensidade modulada de feixe (IMRT) possibilitou a realização de tratamentos de múltiplos alvos simultaneamente em um esquema de tratamento acelerado conhecido como SMART (Simultaneous Modulated Accelerated Radiation Therapy). Estes tratamentos requerem um rigoroso controle de qualidade (QA) que deveria ser realizado, idealmente, em três dimensões. Uma potencial ferramenta para dosimetria tridimensional (3D) é o uso de gel polimérico associado à leitura de doses com Imagens de Ressonância Magnética Nuclear (IRMN). Neste trabalho, a dosimetria 3D com o gel MAGIC-f foi aplicada no CQ de 10 planejamentos radioterápicos usando a técnica SMART. Inicialmente, as distribuições de dose dos planejamentos avaliados foram recalculadas na geometria do simulador baseadas em sua tomogra_a computadorizada. Todos os planejamentos utilizados foram aprovados previamente no QA convencional pontual e planar, o que validou a distribuição de dose do sistema de planejamento (TPS) para comparação com a dosimetria gel. Os simuladores foram irradiados com os planejamentos estabelecidos e as distribuições de dose foram obtidas através da relaxometria em IRMN. A comparação das distribuições de dose calculadas pelo TPS e as medidas no gel foi feita pela análise gama (3%/3mm) e pela comparação entre os histogramas dose-volume (DVHs) calculados e medidos para dois volumes criados nas regiões equivalentes aos volumes alvo de tratamento. Esses resultados evidenciam o potencial do uso da dosimetria gel polimérica no QA 3D de planejamentos de IMRT com a técnica SMART, fornecendo informação completa 3D da dose absorvida em cada volume alvo planejado, desde que realizada seguindo os protocolos pré-estabelecidos. / Intensity Modulated Radiation Therapy (IMRT) treatments in the radiotherapy practice made possible the simultaneously treatment of multiple targets at an accelerated treatment regimen, this scheme is known as Simultaneous Modulated Accelerated Radiation Therapy (SMART). These treatments require a strict quality control (QC) that should be done, ideally, in three dimensions. A potential tool for tridimensional dosimetry (3D) is the use of polymeric gel with Nuclear Magnetic Resonance Images (NMRI). In this paper, the 3D dosimetry with MAGIC-f gel was applied in 10 QC radiotherapy planning using the SMART technique. Initially, the dose distributions of assessed plans were remeasured in simulator geometry based on a CT scan. All plans used were previously approved in punctual and planar conventional CQ, which validated the dose distribution planning system (TPS) for comparison with the gel dosimetry. The simulators were irradiated with established schedules and dose distributions were obtained by relaxometry in NMRI. The comparison of dose distributions calculated by TPS and measured in the gel was made by gamma analysis (3% / 3mm) and by comparing the dose-volume histograms (DVHs) calculated and measured for two volumes created in the equivalent regions to target volumes of treatment. These results highlight the potential use of the polymer gel dosimetry in IMRT planning 3D CQ with SMART technique, providing complete 3D information of the absorbed dose in each target volume planned, if carried out following the pre-established protocols.
3

Estudo de dosimetria gel polimérica em radioterapia com feixes de elétrons utilizando ressonância magnética e simulação Monte Carlo / Study of polymer gel dosimetry in Radiotherapy with electron beams using magnetic resonance imaging and Monte Carlo simulation.

Thatiane Alves Pianoschi 03 February 2014 (has links)
Radioterapia com feixe de elétrons tem sido empregada, frequentemente, para tratamentos de neoplasias superficiais, devido às características de alcance bem definido e alto gradiente de dose em pouca profundidade. Para que as novas técnicas radioterápicas com esse tipo de feixe possam ser implementadas com segurança é necessária a realização de um controle da qualidade rigoroso. Protocolos recomendam que o controle da qualidade para esse tipo de feixe seja realizado com câmara de ionização, porém dosímetros termoluminescentes, diodos e filmes também são empregados com essa finalidade. Entretanto, esses dosímetros não possuem simultaneamente um conjunto de características essenciais para realização do controle da qualidade, como alta resolução espacial, baixa dependência energética, possibilidade de uso em altos gradientes de dose e distribuição tridimensional de dose. Nesse trabalho avaliou-se a utilização do dosímetro polimérico MAGIC-f gel em aplicações em controle da qualidade em Radioterapia com feixes de elétrons. As leituras das amostras de gel foram realizas por ressonância magnética e simulação Monte Carlo foi utilizada para comparação dos resultados. Como parte de um controle da qualidade para feixe de elétrons, foram determinados parâmetros dosimétricos, como perfil de dose e porcentagem de dose em profundidade, e fatores de qualidade do feixe, como R50, em condições de referência e para campos pequenos. Da comparação entre os dados clínicos e MAGIC-f as diferenças máximas encontradas foram de 4%. Além disso, distribuições de dose de aplicações clínicas com feixes de elétrons foram avaliadas pelo método de comparação do índice gama. Considerando os critérios de 3% e 3 mm, os resultados obtidos para o índice gama mostraram concordâncias acima de 94% para os métodos dosimétricos utilizados. Dessa forma, de acordo com as medidas dosimétricas realizadas com o dosímetro MAGIC-f gel conclui- se que a dosimetria polimérica gel pode ser empregada como uma ferramenta auxiliar em procedimentos de controle da qualidade em Radioterapia com feixes de elétrons, assim como uma ferramenta na determinação das distribuições tridimensionais de dose para feixe de elétrons. / Electron beam radiotherapy has been used frequently for treatments of superficial tumors, due its characteristics of well-defined range and high dose gradient at low depth. For new radiotherapy techniques with this type of beam, a strict quality control is necessary for a safe implementation. Protocols recommend that the quality control for electron beams must be performed with an ionization chamber. However, thermoluminescent dosimeters, films and diodes are also used for this purpose. Although, these dosimeters do not have a set of essential characteristics for performing quality control, like high spatial resolution, low energy dependence, possibility of use in high dose gradients and three dimensional dose distribution acquisition. The present work evaluated the use of MAGIC-f gel dosimeter for the quality control in radiotherapy with electron beams. The readings of the gel samples were made by magnetic resonance imaging and Monte Carlo simulation was used to compare the obtained results. As part of a quality control for the electron beam parameters as percentage depth dose and beam profile were determined. Also beam quality factors, such as R50, were calculated in reference conditions and for small fields. The obtained results were compared with clinical data and MAGIC-f the maximum obtained difference was 4%. In addition, dose distributions from clinical applications with electron beams were evaluated by the gamma index. Considering the criteria of 3% DD and 3 mm DTA, the results showed concordance greater than 94% for all dosimetric methods. Thus, according to the dosimetric measurements through MAGIC-f gel dosimeter it can be inferred that the gel dosimeter can be used as auxiliary tool in the quality control procedures in radiotherapy to electron beam. Also, MAGIC-f is a useful a tool to determine tridimensional dose distributions of electron beam.
4

Dosimetria gel no controle de qualidade tridimensional em tratamento de radioterapia com intensidade modulada e técnica SMART (Simultaneous Modulated Accelerated Radiation Therapy) / Gel Dosimetry in Tridimensional Quality Control Radiotherapy Treatments with Intensity Modulated and SMART Technique (Simultaneous Modulated Accelerated Radiation Therapy).

Erick Sebastian Rundo Acurio 28 November 2016 (has links)
A radioterapia com intensidade modulada de feixe (IMRT) possibilitou a realização de tratamentos de múltiplos alvos simultaneamente em um esquema de tratamento acelerado conhecido como SMART (Simultaneous Modulated Accelerated Radiation Therapy). Estes tratamentos requerem um rigoroso controle de qualidade (QA) que deveria ser realizado, idealmente, em três dimensões. Uma potencial ferramenta para dosimetria tridimensional (3D) é o uso de gel polimérico associado à leitura de doses com Imagens de Ressonância Magnética Nuclear (IRMN). Neste trabalho, a dosimetria 3D com o gel MAGIC-f foi aplicada no CQ de 10 planejamentos radioterápicos usando a técnica SMART. Inicialmente, as distribuições de dose dos planejamentos avaliados foram recalculadas na geometria do simulador baseadas em sua tomogra_a computadorizada. Todos os planejamentos utilizados foram aprovados previamente no QA convencional pontual e planar, o que validou a distribuição de dose do sistema de planejamento (TPS) para comparação com a dosimetria gel. Os simuladores foram irradiados com os planejamentos estabelecidos e as distribuições de dose foram obtidas através da relaxometria em IRMN. A comparação das distribuições de dose calculadas pelo TPS e as medidas no gel foi feita pela análise gama (3%/3mm) e pela comparação entre os histogramas dose-volume (DVHs) calculados e medidos para dois volumes criados nas regiões equivalentes aos volumes alvo de tratamento. Esses resultados evidenciam o potencial do uso da dosimetria gel polimérica no QA 3D de planejamentos de IMRT com a técnica SMART, fornecendo informação completa 3D da dose absorvida em cada volume alvo planejado, desde que realizada seguindo os protocolos pré-estabelecidos. / Intensity Modulated Radiation Therapy (IMRT) treatments in the radiotherapy practice made possible the simultaneously treatment of multiple targets at an accelerated treatment regimen, this scheme is known as Simultaneous Modulated Accelerated Radiation Therapy (SMART). These treatments require a strict quality control (QC) that should be done, ideally, in three dimensions. A potential tool for tridimensional dosimetry (3D) is the use of polymeric gel with Nuclear Magnetic Resonance Images (NMRI). In this paper, the 3D dosimetry with MAGIC-f gel was applied in 10 QC radiotherapy planning using the SMART technique. Initially, the dose distributions of assessed plans were remeasured in simulator geometry based on a CT scan. All plans used were previously approved in punctual and planar conventional CQ, which validated the dose distribution planning system (TPS) for comparison with the gel dosimetry. The simulators were irradiated with established schedules and dose distributions were obtained by relaxometry in NMRI. The comparison of dose distributions calculated by TPS and measured in the gel was made by gamma analysis (3% / 3mm) and by comparing the dose-volume histograms (DVHs) calculated and measured for two volumes created in the equivalent regions to target volumes of treatment. These results highlight the potential use of the polymer gel dosimetry in IMRT planning 3D CQ with SMART technique, providing complete 3D information of the absorbed dose in each target volume planned, if carried out following the pre-established protocols.
5

Avaliação de parâmetros dosimétricos de fontes de braquiterapia utilizando simulação Monte Carlo e dosimetria gel polimérica / Evaluation of Dosimetric Parameters of Brachytherapy Sources Using Monte Carlo Simulation and Polymer Gel Dosimetry.

Silva, Ana Luiza Quevedo Ramos da 08 September 2014 (has links)
A dosimetria em braquiterapia é importante para garantir a igualdade entre a dose entregue ao paciente e a dose planejada, porém a determinação experimental da dose é difícil devido ao alto gradiente de dose em regiões próximas à fonte. Nesse sentido, a dosimetria gel polimérica têm sido estudada como forma de se obter a distribuição tridimensional das doses dessas fontes. O protocolo da Associação Americana de Físicos em Medicina, intitulado TG-43, propõe um formalismo para o cálculo de dose de fontes de braquiterapia através de parâmetros da atividade, anisotropia e geometria da fonte, além de atenuação e espalhamento da radiação produzida pela fonte. Porém, a determinação das funções dosimétricas necessárias para o cálculo da dose não é feita diretamente através de experimentos. Nessa linha, o Método Monte Carlo vêm sendo utilizado no cálculo dessas funções dosimétricas em braquiterapia. Neste trabalho, foram determinados os parâmetros dosimétricos de duas fontes de braquiterapia, 60Co e 192Ir, utilizando simulação Monte Carlo com o código PENELOPE, assim como as distribuições de dose utilizando dosimetria gel polimérica com o MAGIC-f. Os dados obtidos computacionalmente foram comparados com a literatura, obtendo-se concordância melhor que 98% em todos os parâmetros para a fonte de 60Co. Para a fonte de 192Ir, encontraram-se diferenças de até 22%, embora quando os resultados deste trabalho foram comparados com o sistema de planejamento, o ajuste utilizado para o conjunto de pontos possui R2 de 0,9996. A comparação das distribuições de dose da fonte de 192Ir simuladas e determinadas com o gel polimérico MAGIC-f, apresentou concordância de 97% nos pontos englobados pela isodose de 50%, quando o critério de 3% e 3 mm foi utilizado. Esses resultados evidenciam o potencial do uso da dosimetria gel polimérica e da simulação Monte Carlo com o código PENELOPE em dosimetria de fontes de braquiterapia de alta taxa de dose. / Dosimetry in brachytherapy is important to assure the conformity between the planned and the delivered dose to the patient. However, the experimental determination of dose is difficult in this technique due the high dose gradient in regions near the source. Hence, polymer gel dosimetry has been studied as a tool to obtain three-dimensional distribution dose for these sources. A report of American Association of Medical Physics, entitled TG-43, proposes a formalism for dose calculation for brachytherapy sources through parameters such as activity, anisotropy and geometry of the source, and the attenuation and radiation scattering produced in the surrounding medium. However, the dosimetric functions needed for dose calculations are not directly determined through experiments. In this concern, the Monte Carlo method has been used in the calculation of these dosimetric funcions in brachytherapy. In the present work, the dosimetric parameters for two brachytherapy sources, 60Co e 192Ir, were determined using Monte Carlo simulation with PENELOPE code, and the dose distributions for the 192Ir source were determined using polymer gel dosimetry with MAGIC-f. Data obtained computationally were compared to literature, showing more than 98% agreement in all parameters for the 60Co source. For 192Ir, differences up to 22% were found to the literature, although when the results of this work were compared to the treatment planning system, a R2 equal to 0,9996 was found to the data fitting adjusting both data. The comparison of simulated dose distributions for 192Ir and those determined with MAGIC-f polymer gel showed that 97% of the points covered by 50% isodose are in agreement when gamma index criteria of 3% and 3 mm was used. These results indicate the potential use of polymer gel dosimetry with MAGIC-f and Monte Carlo simulation with PENELOPE code in dosimetry of high dose rate brachytherapy sources.
6

Um estudo para otimização da formulação do dosímetro gel MAGIC-f e avaliação da sua reutilização / A study to optimize the formulation of the MAGIC-f dosimeter and evaluate its reuse

Resende, Thiago Dias 07 April 2017 (has links)
A radioterapia é um procedimento que utiliza radiação ionizante de alta energia direcionado ao tumor, para destruir suas células. O objetivo é provocar o maior dano nas células tumorais enquanto se poupa o tecido sadio ao redor, para maximizar este resultado. Devido a alta complexidade dos feixes usados nestes tratamentos, um dosímetro tridimensional é desejado para garantir que a dose esteja sendo entregue da forma como foi planejada, sendo a dosimetria gel polimérica com leitura da dose em Imagens de Ressonância Magnética Nuclear (IRMN), uma opção para esta medida. Esse trabalho utiliza o dosímetro gel polimérico MAGIC-f como referência e tem como objetivo otimizar sua formulação, substituindo inicialmente os seus agentes antioxidantes (sulfato de cobre e ácido ascórbico) por um antioxidante mais potente, o cloreto de tetrakishidroximetilfosfônio (THPC), e, em seguida, variar as concentrações dos demais componentes do dosímetro a fim de obter a menor concentração de cada um deles que resulte em um dosímetro com sensibilidade adequada para uso em radioterapia.Foram feitas análises sobre a estabilidade térmica do dosímetro com THPC e estudos sobre as concentrações ideais de THPC (2mM, 5mM, 8mM, 10mM ou 20mM); Ácido Metacrílico (2%, 2,5%, 3%, 3,5% ou 4%); Gelatina (4%, 6%, 8% ou 10%). Após todas as modificações, a formulação otimizada contendo 88,96% Água MiliQ; 3% Ácido Metacrílico; 8% Gelatina; 0,04% THPC (5mM de concentração), apresentou uma sensibilidade próxima a 1,03 Gy-1s-1 e um ponto de fusão de aproximadamente 50C, utilizando as menores quantidades possíveis dos reagentes químicos e a sequência de leitura das IRMN implementada para esta dosimetria. O dosímetro otimizado obtido teve uma redução de 40% no seu custo, em comparação com o dosímetro MAGIC-f, e uma resolução de dose de 0,18 Gy. Obteve linearidade de resposta a dosede 0 a 10 Gy. Uma variação máxima na sensibilidade do dosímetro de 8,5% foi encontrada ao se variar a taxa de dose de 300 500 cGy/min.Também foi avaliada a integridade da distribuição de dose para esse dosímetro através da avaliação de uma irradiação com meio campo blindado. E, sua a maior variação em um teste de repetitividade foi de 15%. Um outro objetivo deste trabalho foi o desenvolvimento de uma metodologia para a reutilização do dosímetro gel, sendo que um dosímetro previamente irradiado com uma dose de 2Gy foi reutilizado após seu derretimento a 50C em um forno com controle digital de temperatura, seguido por uma nova gelificação.Para garantir sua resposta, foi necessária a readição de agentes antioxidantes à formulação reutilizada. Dessa forma, para o gel MAGAT com 1mM de THPC foi obtida uma sensibilidade 30% menor que a original para o dosímetro reutilizado e 15% para o mesmo dosímetro, com 2mM de THPC / Radiotherapy is a procedure that uses high energy ionizing radiation directed to the tumor to destroy its cells. The objective is to obtain tumoral cells more damaged avoiding the healthy cells around it and increase this result. Due to the high complexity of the energy beams used on these treatments, a three-dimensional dosimeter is demanded to assure that the dose is focused as planned, being the polymeric gel dosimetry using Nuclear Magnetic Resonance Images (NMRI) for dose scanning an option to this measurement. This work uses MAGIC-f gel as reference and its objective is to optimize the dosimeter formulation, by initiallyreplacing the antioxidants agents (Copper Sulfate and Ascorbic Acid) by a more power rating antioxidant, Tetrakis (hydroxymethyl) phosphonium chloride (THPC), and then, variatingthe others dosimeter´s components concentration in order to obtain the smallest concentration of each one that result in an adequate dosimeter´ssensitivity for radiotherapy application. Studies were made to check the thermal stability of the gel containing THPC and studies were carried out about the ideals concentrations of THPC (2mM, 5mM, 8mM, 10mM or 20mM); Methacrylic Acid (2%, 2.5%, 3%, 3.5% or 4%); Gelatin (4%, 6%, 8% or 10%). After the modifications, the optimized formulation containing 88.96% of mili-Q water; 3% of methacrylic acid; 8% of gelatine; 0.04% of THPC (5mM) showed a sensitivity of approximately 1.03 Gy-1s-1 and a melting point approximately of 50°C, using the smallest possible chemical compounds concentrations and the NMRI scanning sequence implemented for this dosimetry. The optimized dosimeter obtained presents a 40% cost reduction, comparing with the dosimeter MAGIC-f, and a dose resolution of 0.18 Gy. The dosimeter responds linearlywith doses from 0 to 10 Gy. A maximal sensitivity variation of 8.5% was found when varing the dose rate from 300 to 500 cGy/min. Its dose integrity was checked by a half beam blocked irradiation. And its largestsensitivity variation at a repeatability test was 15%. The second objective of this work was the development of a methodology for reusing the dosimeter.The dosimeter previously irradiated with 2Gy was reused after being melted in a digitaltemperature control oven at 50°C, followed by the re-addition of THPC and a new gelation. The reused MAGAT gel dosimeter with 1mM of THPC presented 30% sensitivity reductioin when compared to the the same dosimeter before the reusing process, while the MAGAT gel with 2mMof THPC presented a reduction of only 15%
7

Avaliação de parâmetros dosimétricos de fontes de braquiterapia utilizando simulação Monte Carlo e dosimetria gel polimérica / Evaluation of Dosimetric Parameters of Brachytherapy Sources Using Monte Carlo Simulation and Polymer Gel Dosimetry.

Ana Luiza Quevedo Ramos da Silva 08 September 2014 (has links)
A dosimetria em braquiterapia é importante para garantir a igualdade entre a dose entregue ao paciente e a dose planejada, porém a determinação experimental da dose é difícil devido ao alto gradiente de dose em regiões próximas à fonte. Nesse sentido, a dosimetria gel polimérica têm sido estudada como forma de se obter a distribuição tridimensional das doses dessas fontes. O protocolo da Associação Americana de Físicos em Medicina, intitulado TG-43, propõe um formalismo para o cálculo de dose de fontes de braquiterapia através de parâmetros da atividade, anisotropia e geometria da fonte, além de atenuação e espalhamento da radiação produzida pela fonte. Porém, a determinação das funções dosimétricas necessárias para o cálculo da dose não é feita diretamente através de experimentos. Nessa linha, o Método Monte Carlo vêm sendo utilizado no cálculo dessas funções dosimétricas em braquiterapia. Neste trabalho, foram determinados os parâmetros dosimétricos de duas fontes de braquiterapia, 60Co e 192Ir, utilizando simulação Monte Carlo com o código PENELOPE, assim como as distribuições de dose utilizando dosimetria gel polimérica com o MAGIC-f. Os dados obtidos computacionalmente foram comparados com a literatura, obtendo-se concordância melhor que 98% em todos os parâmetros para a fonte de 60Co. Para a fonte de 192Ir, encontraram-se diferenças de até 22%, embora quando os resultados deste trabalho foram comparados com o sistema de planejamento, o ajuste utilizado para o conjunto de pontos possui R2 de 0,9996. A comparação das distribuições de dose da fonte de 192Ir simuladas e determinadas com o gel polimérico MAGIC-f, apresentou concordância de 97% nos pontos englobados pela isodose de 50%, quando o critério de 3% e 3 mm foi utilizado. Esses resultados evidenciam o potencial do uso da dosimetria gel polimérica e da simulação Monte Carlo com o código PENELOPE em dosimetria de fontes de braquiterapia de alta taxa de dose. / Dosimetry in brachytherapy is important to assure the conformity between the planned and the delivered dose to the patient. However, the experimental determination of dose is difficult in this technique due the high dose gradient in regions near the source. Hence, polymer gel dosimetry has been studied as a tool to obtain three-dimensional distribution dose for these sources. A report of American Association of Medical Physics, entitled TG-43, proposes a formalism for dose calculation for brachytherapy sources through parameters such as activity, anisotropy and geometry of the source, and the attenuation and radiation scattering produced in the surrounding medium. However, the dosimetric functions needed for dose calculations are not directly determined through experiments. In this concern, the Monte Carlo method has been used in the calculation of these dosimetric funcions in brachytherapy. In the present work, the dosimetric parameters for two brachytherapy sources, 60Co e 192Ir, were determined using Monte Carlo simulation with PENELOPE code, and the dose distributions for the 192Ir source were determined using polymer gel dosimetry with MAGIC-f. Data obtained computationally were compared to literature, showing more than 98% agreement in all parameters for the 60Co source. For 192Ir, differences up to 22% were found to the literature, although when the results of this work were compared to the treatment planning system, a R2 equal to 0,9996 was found to the data fitting adjusting both data. The comparison of simulated dose distributions for 192Ir and those determined with MAGIC-f polymer gel showed that 97% of the points covered by 50% isodose are in agreement when gamma index criteria of 3% and 3 mm was used. These results indicate the potential use of polymer gel dosimetry with MAGIC-f and Monte Carlo simulation with PENELOPE code in dosimetry of high dose rate brachytherapy sources.
8

Um estudo para otimização da formulação do dosímetro gel MAGIC-f e avaliação da sua reutilização / A study to optimize the formulation of the MAGIC-f dosimeter and evaluate its reuse

Thiago Dias Resende 07 April 2017 (has links)
A radioterapia é um procedimento que utiliza radiação ionizante de alta energia direcionado ao tumor, para destruir suas células. O objetivo é provocar o maior dano nas células tumorais enquanto se poupa o tecido sadio ao redor, para maximizar este resultado. Devido a alta complexidade dos feixes usados nestes tratamentos, um dosímetro tridimensional é desejado para garantir que a dose esteja sendo entregue da forma como foi planejada, sendo a dosimetria gel polimérica com leitura da dose em Imagens de Ressonância Magnética Nuclear (IRMN), uma opção para esta medida. Esse trabalho utiliza o dosímetro gel polimérico MAGIC-f como referência e tem como objetivo otimizar sua formulação, substituindo inicialmente os seus agentes antioxidantes (sulfato de cobre e ácido ascórbico) por um antioxidante mais potente, o cloreto de tetrakishidroximetilfosfônio (THPC), e, em seguida, variar as concentrações dos demais componentes do dosímetro a fim de obter a menor concentração de cada um deles que resulte em um dosímetro com sensibilidade adequada para uso em radioterapia.Foram feitas análises sobre a estabilidade térmica do dosímetro com THPC e estudos sobre as concentrações ideais de THPC (2mM, 5mM, 8mM, 10mM ou 20mM); Ácido Metacrílico (2%, 2,5%, 3%, 3,5% ou 4%); Gelatina (4%, 6%, 8% ou 10%). Após todas as modificações, a formulação otimizada contendo 88,96% Água MiliQ; 3% Ácido Metacrílico; 8% Gelatina; 0,04% THPC (5mM de concentração), apresentou uma sensibilidade próxima a 1,03 Gy-1s-1 e um ponto de fusão de aproximadamente 50C, utilizando as menores quantidades possíveis dos reagentes químicos e a sequência de leitura das IRMN implementada para esta dosimetria. O dosímetro otimizado obtido teve uma redução de 40% no seu custo, em comparação com o dosímetro MAGIC-f, e uma resolução de dose de 0,18 Gy. Obteve linearidade de resposta a dosede 0 a 10 Gy. Uma variação máxima na sensibilidade do dosímetro de 8,5% foi encontrada ao se variar a taxa de dose de 300 500 cGy/min.Também foi avaliada a integridade da distribuição de dose para esse dosímetro através da avaliação de uma irradiação com meio campo blindado. E, sua a maior variação em um teste de repetitividade foi de 15%. Um outro objetivo deste trabalho foi o desenvolvimento de uma metodologia para a reutilização do dosímetro gel, sendo que um dosímetro previamente irradiado com uma dose de 2Gy foi reutilizado após seu derretimento a 50C em um forno com controle digital de temperatura, seguido por uma nova gelificação.Para garantir sua resposta, foi necessária a readição de agentes antioxidantes à formulação reutilizada. Dessa forma, para o gel MAGAT com 1mM de THPC foi obtida uma sensibilidade 30% menor que a original para o dosímetro reutilizado e 15% para o mesmo dosímetro, com 2mM de THPC / Radiotherapy is a procedure that uses high energy ionizing radiation directed to the tumor to destroy its cells. The objective is to obtain tumoral cells more damaged avoiding the healthy cells around it and increase this result. Due to the high complexity of the energy beams used on these treatments, a three-dimensional dosimeter is demanded to assure that the dose is focused as planned, being the polymeric gel dosimetry using Nuclear Magnetic Resonance Images (NMRI) for dose scanning an option to this measurement. This work uses MAGIC-f gel as reference and its objective is to optimize the dosimeter formulation, by initiallyreplacing the antioxidants agents (Copper Sulfate and Ascorbic Acid) by a more power rating antioxidant, Tetrakis (hydroxymethyl) phosphonium chloride (THPC), and then, variatingthe others dosimeter´s components concentration in order to obtain the smallest concentration of each one that result in an adequate dosimeter´ssensitivity for radiotherapy application. Studies were made to check the thermal stability of the gel containing THPC and studies were carried out about the ideals concentrations of THPC (2mM, 5mM, 8mM, 10mM or 20mM); Methacrylic Acid (2%, 2.5%, 3%, 3.5% or 4%); Gelatin (4%, 6%, 8% or 10%). After the modifications, the optimized formulation containing 88.96% of mili-Q water; 3% of methacrylic acid; 8% of gelatine; 0.04% of THPC (5mM) showed a sensitivity of approximately 1.03 Gy-1s-1 and a melting point approximately of 50°C, using the smallest possible chemical compounds concentrations and the NMRI scanning sequence implemented for this dosimetry. The optimized dosimeter obtained presents a 40% cost reduction, comparing with the dosimeter MAGIC-f, and a dose resolution of 0.18 Gy. The dosimeter responds linearlywith doses from 0 to 10 Gy. A maximal sensitivity variation of 8.5% was found when varing the dose rate from 300 to 500 cGy/min. Its dose integrity was checked by a half beam blocked irradiation. And its largestsensitivity variation at a repeatability test was 15%. The second objective of this work was the development of a methodology for reusing the dosimeter.The dosimeter previously irradiated with 2Gy was reused after being melted in a digitaltemperature control oven at 50°C, followed by the re-addition of THPC and a new gelation. The reused MAGAT gel dosimeter with 1mM of THPC presented 30% sensitivity reductioin when compared to the the same dosimeter before the reusing process, while the MAGAT gel with 2mMof THPC presented a reduction of only 15%
9

Comparação dosimétrica 3D de tratamentos de câncer de mama com técnica conformacional 3D usando filtros e com IMRT direto e inverso na presença do movimento respiratório / 3D dosimetric comparison of breast cancer treatments with 3D conformational technique using filters and with direct and inverse IMRT in the presence of respiratory movement

Lizar, Jéssica Caroline 03 April 2017 (has links)
A radioterapia externa pós-operatória em mulheres diagnosticadas com câncer de mama em estágio inicial é tido como um procedimento padrão, no entanto durante o planejamento para irradiação do volume alvo as possíveis incertezas dosimétricas introduzidas dado o movimento respiratório intrínseco da paciente são desconsideradas. Este estudo avalia não apenas a influência da respiração na distribuição tridimensional da dose, mas como essa distribuição se modifica dado a técnica radioterápica empregada para o tratamento. Três técnicas de planejamento foram analisadas: a radioterapia conformacional tridimensional (3D-RT) com filtros, a radioterapia com intensidade modulada (IMRT) usando planejamento direto e o IMRT inverso. A fim de simular o movimento de contração e expansão da caixa torácica, utilizou-se uma plataforma com amplitudes de oscilação pré-determinadas, sendo a frequência de oscilação provida por uma fonte de tensão variável. Para simular a mama usou-se objetos simuladores semiesféricos preenchidos com gel dosimétrico (MAGIC-f). Os planejamentos para cada técnica foram realizados sobre a mesma tomografia computadorizada (CT) do objeto simulador preenchido com água no modo estático. Foram produzidos três lotes de dosímetro gel para o projeto, cada lote foi irradiado com uma técnica radioterápica diferente, sendo que cada lote inclui cinco objetos simuladores e um conjunto de nove tubos de calibração preenchidos com gel MAGIC-f. O primeiro dos objetos simuladores é utilizado como referência, o segundo é irradiado no modo estático, os demais são irradiados em diferentes amplitudes, respectivamente: 0,34 cm, 0,88 cm e 1,22 cm. A informação volumétrica de dose foi obtida utilizando imagens por ressonância magnética nuclear (IRMN), para cada lote foram adquiridos IRMN com sequência multi spin echo e os mapas de relaxometria, que são associados à dose, foram extraídos em um software desenvolvido e aprimorado pelo nosso grupo de pesquisa. A comparação quantitativa dos mapas de relaxometria dos objetos simuladores em movimento em relação ao modo estático foi realizado pelo índice gamma tridimensional (3% / 3mm / 15% Threshold). Para o 3D-RT a porcentagem de pontos aprovados do objeto estático em relação ao oscilante na amplitude de 0,34 cm foi de 96,44%, para amplitude de 0,88 cm foi de 93,23% e para amplitude de 1,22 cm foi de 91,65%. Para o IMRT direto a porcentagem de pontos aprovados do objeto estático em relação ao oscilante na amplitude de 0,34 cm foi de 98,42%, para amplitude de 0,88 cm foi de 95,66% e para amplitude de 1,22 cm foi de 94,31%. Para o IMRT inverso a porcentagem de pontos aprovados do objeto estático em relação ao oscilante na amplitude de 0,34 cm foi de 94,49%, para amplitude de 0,88 cm foi de 93,51% e para amplitude de 1,22 cm foi de 86,62%. A partir dos resultados, infere-se que a movimentação respiratória de baixa amplitude, para tratamentos de câncer de mama, não é um fator preocupante para a rotina clínica, porém o aumento da amplitude da oscilação aumenta a inomogeneidade de dose e pode afetar os parâmetros dosimétricos da cobertura do volume alvo em relação ao planejamento do tratamento. Observou-se em conjunto que a distribuição de dose se modifica claramente com a técnica em uso e no caso do IMRT inverso para amplitude de oscilação de 1,22 cm a aprovação no índice gamma foi menor que 90% / External postoperative radiotherapy in women diagnosed with early stage breast cancer is considered as a standard procedure, however during planning for target volume irradiation as possible dosimetric uncertainties reabsorption of the patient\'s intrinsic respiratory movement are disregarded. This study evaluates not only the influence of respiration on the three-dimensional distribution of the dose but how this distribution is modified due to the radiotherapy technique used for treatment. Three planning techniques were analyzed: three-dimensional conformational radiotherapy (3D-RT) with filters, intensity-modulated radiotherapy (IMRT) using direct planning and inverse IMRT. In order to simulate the movement of contraction and expansion of the chest wall, a platform with predetermined oscillation amplitudes was used, the oscillation frequency was provided by a variable voltage source. To simulate the breast, semi-spherical simulator objects filled with dosimetric gel (MAGIC-f) were used. The plannnings for each technique were performed on the computerized tomography (CT) of the simulator object filled with water in static mode. Three batches of gel dosimeters were prepared for the project, each batch was irradiated with a different radiothermic technique and comprised five simulator objects and a set of nine calibration tubes filled with MAGIC-f gel. The first simulator objects is used as reference, the second is irradiated in the static mode, the others are irradiated using different amplitudes, respectively: 0,34 cm, 0,88 cm and 1,22 cm. Volumetric dose information was obtained using Nuclear Magnetic Resonance Imaging, each batch was scanned with a multi spin echo sequence and the dose-related relaxometry maps were extracted in a software developed and improved by our Group of research. The quantitative comparison of the relaxometry maps of the moving simulator objects with respect to the static mode was performed by the three-dimensional gamma index (3% / 3mm / 15% threshold). For the 3D-RT, the percentage of approved points of the static object with respect to the oscillator in the amplitude of 0.34 cm was 96.44%, for amplitude of 0.88 cm was 93.23% and for amplitude of 1.22 cm was 91.65%. For the direct IMRT the percentage of approved points of the static object in relation to the oscillator in the amplitude of 0.34 cm was 98.42%, for amplitude of 0.88 cm was 95.66% and for amplitude of 1.22 cm was 94.31%. For the inverse IMRT, the percentage of approved points of the static object in relation to the oscillator in the amplitude of 0.34 cm was 94.49%, for amplitude of 0.88 cm was 93.51% and for amplitude of 1.22 cm was 86.62%. From the results, it is inferred that a low-amplitude respiratory movement, for breast cancer treatments, is not a worrying factor for clinical routine, however, increasing the amplitude of the oscillation increases the inomogeneity of the dose and this affects the dosimetry parameters of the target volume coverage. It was observed that the dose distribution changes with the technique in use and in the case of the inverse IMRT for amplitude of oscillation of 1.22 cm, less than 90% of points were approved in the gamma index evaluation
10

Verificação 3D da distribuição da dose em radiocirurgia estereotáxica através de simulação Monte Carlo e dosimetria por ressonância magnética nuclear / Dose distribution verification in 3D to stereotactic radiosurgery through Monte Carlo simulation and gel dosimetry with nuclear magnetic resonance 2012

Alva Sánchez, Mirko Salomón 24 October 2012 (has links)
A radiocirugia estereotáxica é uma técnica que fornece altas doses de radiação utilizando campos pequenos para conformação da dose no volume alvo do tratamento. Devido à complexidade desta técnica torna-se necessária a verificação da distribuição de dose no volume de tratamento. Neste trabalho, as distribuições tridimensionais (3D) de doses de casos clínicos de neoplasias cranianas foram estudadas utilizando-se um objeto simulador de cabeça. A reconstrução das distribuições de doses nos volumes alvo e nas regiões adjacentes a estes foram avaliadas com o código de simulação PENELOPE, o dosímetro MAGIC-f gel e com o sistema de planejamento iPlan. Filmes radiocrômicos também foram empregados para a determinação das distribuições de dose em planos do tratamento. As respostas obtidas com as ferramentas dosimétricas utilizadas foram analisadas através de distribuições de índices gama, comparando-se os mapas centrais das distribuições de dose obtidas com as quatro ferramentas dosimétricas utilizadas. Usando-se critérios de tolerância de 3% e 3mm, a análise realizada na região da prescrição de dose (isodoses de 95%) mostrou-se equivalente para todas as ferramentas dosimétricas utilizadas; resultado diferente foi observado para isodoses menores, com uma equivalência máxima de 76,5%. As distribuições volumétricas, obtidas através do PENELOPE, MAGIC-f gel e o iPlan, foram comparadas, ainda, através dos histogramas dose-volume, para cada caso estudado, mostrando que 95% da dose absorvida relativa encontra-se dentro do volume alvo para todos os planos estudados. A probabilidade de controle tumoral, TCP, foi avaliada para os casos de radiocirurgia estudados, a partir das distribuições volumétricas de dose, resultando em uma probabilidade de controle tumoral máxima de 72%, para todos os casos, conforme o modelo matemático de TCP utilizado. Das comparações realizadas pode-se inferir que o dosímetro MAGIC-f gel e o código de simulação PENELOPE-Monte Carlo podem ser utilizados para determinar as distribuições de dose em 3D para a técnica de radiocirurgia estereotáxica. Essas ferramentas dosimétricas podem, dessa forma, auxiliar no comissionamento de unidades de terapia e em verificações 3D de doses do tratamento dos pacientes, permitindo avaliações dentro e ao redor do volume alvo e podendo se tornar ferramentais de rotina nos serviços de radioterapia. / Stereotactic radiosurgery is a technique which delivers high radiation doses using small fields to conform the absorbed dose into the target volume. Due to the complexity of this technique it is necessary to verify the dose distribution in the treatment volume. Thus, in this study the three-dimensional (3D) dose distributions of selected clinical cases of cranial tumors were obtained using a head phantom. The the dose distributions of target volumes and adjacent regions were evaluated with PENELOPE Monte Carlo simulation code, MAGIC-f dosimeter and iPlan® treatment planning system. Radiochromic films were also used to determine the dose distribution on selected plans of the treatment. The obtained results for the proposed dosimetric tools were analyzed by the gamma index distributions, comparing the maps of the central dose distributions obtained with the four dosimetric tools. Using the dose criteria of 3% in 3 mm, the gamma index test showed equivalence in the region of dose prescription (95% isodose) and a different result was observed for lower isodoses, with maximum accordance of 76.5%. The volumetric dose distributions obtained with PENELOPE, MAGIC-f and iPlan were also compared using the dose-volume histograms for each studied case, showing that 95% of the absorbed dose yield within the target volume. The tumor control probability, TCP, was evaluated for the studied radiosurgery cases, from the dose distributions-volumetric, resulting in a maximum probability of tumor control of 72% for all cases, for the used mathematical model of TCP. From the results it can be inferred that the MAGIC-f gel dosimeter and the PENELOPE Monte Carlo simulation code can be used to determine 3D dose distributions for stereotactic radiosurgery. These dosimetric tools can assist the commissioning of treatment units and 3D dose verifications of patients treatments, allowing assessments in and around the target volume and may become routine in radiotherapy services.

Page generated in 0.4115 seconds