1

Glicosímetro de pulso / Pulse glucometer.

Castro Júnior, Roberto 07 April 2010 (has links)
Este trabalho descreve o desenvolvimento e a avaliação clínica de um instrumento para monitorização contínua e não-invasiva da concentração de glicose no sangue arterial adotando o mesmo método que a oximetria de pulso utiliza para determinação da saturação do sangue arterial. O sistema para medição de glicemia de pulso desenvolvido neste trabalho foi projetado a partir da utilização de um sensor óptico similar aos sensores de oximetria de pulso utilizando os comprimentos de onda de 805 e 1350 nm. Foi realizada uma avaliação clínica do instrumento com 20 voluntários masculinos e femininos entre 16 e 63 anos, de 48 a 112 kg e diferentes raças. Para estes voluntários, o instrumento apresentou uma exatidão (Arms) e desvio padrão (SDR) da ordem de 10 mg/dl, que podem ser considerados muito bons, quando comparado com monitores de glicemia do tipo ponta de dedo, que apresentam uma exatidão da leitura da ordem de 15 mg/dl para a faixa de medidas utilizada. / This paper describes the development and the clinical evaluation of a continuous non-invasive monitoring device for blood glucose concentration in arterial blood. The adopted method was the same one used in pulse oximetry for determining arterial blood saturation. The measurement system developed in this project to determine pulse blood glucose level was based on an optical sensor similar to the pulse oximetry sensors using wavelengths of 805 and 1350 nm. A clinical trial of the device was performed with 20 volunteers, both male and female, aged 16 to 63, weighting 48 to 112 kg and of different races. For this group of volunteers the device presented an accuracy (Arms) e standard deviation (SDR) in the magnitude of 10 mg/dl, considered very good when compared to blood glucose monitors of the fingertip type, which presents a reading accuracy in the magnitude of 15 mg/dl for the range of measurements employed.
2

Glicosímetro de pulso / Pulse glucometer.

Roberto Castro Júnior 07 April 2010 (has links)
Este trabalho descreve o desenvolvimento e a avaliação clínica de um instrumento para monitorização contínua e não-invasiva da concentração de glicose no sangue arterial adotando o mesmo método que a oximetria de pulso utiliza para determinação da saturação do sangue arterial. O sistema para medição de glicemia de pulso desenvolvido neste trabalho foi projetado a partir da utilização de um sensor óptico similar aos sensores de oximetria de pulso utilizando os comprimentos de onda de 805 e 1350 nm. Foi realizada uma avaliação clínica do instrumento com 20 voluntários masculinos e femininos entre 16 e 63 anos, de 48 a 112 kg e diferentes raças. Para estes voluntários, o instrumento apresentou uma exatidão (Arms) e desvio padrão (SDR) da ordem de 10 mg/dl, que podem ser considerados muito bons, quando comparado com monitores de glicemia do tipo ponta de dedo, que apresentam uma exatidão da leitura da ordem de 15 mg/dl para a faixa de medidas utilizada. / This paper describes the development and the clinical evaluation of a continuous non-invasive monitoring device for blood glucose concentration in arterial blood. The adopted method was the same one used in pulse oximetry for determining arterial blood saturation. The measurement system developed in this project to determine pulse blood glucose level was based on an optical sensor similar to the pulse oximetry sensors using wavelengths of 805 and 1350 nm. A clinical trial of the device was performed with 20 volunteers, both male and female, aged 16 to 63, weighting 48 to 112 kg and of different races. For this group of volunteers the device presented an accuracy (Arms) e standard deviation (SDR) in the magnitude of 10 mg/dl, considered very good when compared to blood glucose monitors of the fingertip type, which presents a reading accuracy in the magnitude of 15 mg/dl for the range of measurements employed.
3

Sistema de monitoramento digital de grandezas elétricas

Paranhos, Ígor Abrahão January 2007 (has links)
Made available in DSpace on 2013-08-07T18:53:39Z (GMT). No. of bitstreams: 1 000396050-Texto+Completo-0.pdf: 5610208 bytes, checksum: 53048425f8fbc45914d3914ccd959eb8 (MD5) Previous issue date: 2007 / The technology associated to modern electronic devices is helping the control over industrial processes, which has increased the productive and the reliability on many sectors, resulting in the production of high quality products. However, the usage of these equipments over production lines makes the system more susceptible to power quality events, because of the associated micro-electronics. The appearance of non-linear loads has been affected directly the voltage and current signals, making the environment electrically polluted. The concern with the power quality has significantly increased on the past few years, mainly due to the consumers aiming the avoidance of nonprogrammable stops in the production line (due to bad functioning of equipments), and also due to the concessionaires of electric energy desiring an adequate control over the system. Meanwhile, the power monitoring systems have appeared in the market with improved functions, mostly because of technology development. However, many of these monitoring systems are expensive, mainly in economies of developing countries, making harder for small companies to acquire one. Less expensive systems are available in the market, but with no capacity of database recourses. This work proposes the implementation of low cost electrical digital monitoring systems with database resources. In addition, the proposed monitoring system is capable of remote access to the database through an internet web page. To this end, hardware to acquire three-phase voltage and current signals and software to download the data are developed, where the software is capable of data processing, mathematical calculus, producing data graphics for analysis and to manage the information for the WEB interface. In addition, the state of the art in electric monitoring systems is revised in order to characterize the functionalities and resources of available commercial products, as well as a bibliographic review to give a picture of the tendencies in this area. / A alta tecnologia encontrada nos equipamentos modernos tem colaborado no controle de processos industriais, aumentando a produtividade e a confiabilidade em diversos setores, facilitando a elaboração de produtos de melhor acabamento. Entretanto, a utilização destes equipamentos em linhas de produção aumenta consideravelmente a susceptibilidade do sistema aos distúrbios na qualidade de energia, devido à micro-eletrônica associada. O aparecimento de cargas não-lineares tem afetado diretamente os sinais de corrente e tensão, de forma a deixar o ambiente eletricamente poluído. A preocupação com os níveis da qualidade da energia elétrica vem aumentando bastante nos últimos anos, tanto para consumidores como para as concessionárias. Em meio a isto, sistemas de monitoramento da qualidade da energia foram surgindo, e de acordo com o desenvolvimento tecnológico, sendo acrescidos de novas funções. Porém, muitos se tornaram de custo elevado, de forma a não serem acessíveis a empresas de recursos limitados. Sistemas mais simples também passaram a ser comercializados, todavia, sem determinadas ferramentas, como banco de dados. Este trabalho apresenta a implementação de um sistema de monitoramento digital de grandezas elétricas, que visa aliar o baixo custo à um recurso de banco de dados (para o armazenamento da informações), e à visualização remota dos mesmos, através de uma página da internet. Para isso, foi desenvolvido um hardware para fazer a leitura trifásica de tensão e corrente, baseado no micro-controlador MSP430f169; um software para a aquisição dos dados, apresentação de cálculos, gráficos e armazenagem, desenvolvido sob a plataforma Delphi 5; um banco de dados (em PostgreSQL) e uma interface WEB, fazendo-se uso da linguagem PHP. Também, é proposto um estudo a respeito do assunto, de forma a caracterizar alguns sistemas e recursos encontrados nos produtos comerciais, assim como uma revisão bibliográfica, apontando as tendências para essa área.