• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Mise au point de détecteurs Micromegas pour le spectromètre CLAS12 au laboratoire Jefferson / Development of Micromegas detectors for the CLAS12 experiment at Jefferson Laboratory

Charles, Gabriel 24 September 2013 (has links)
Cette thèse présente mon travail de recherche accompli depuis 2010 pour développer les détecteurs Micromegas du spectromètre CLAS12 qui sera installé dans le hall B du laboratoire Jefferson aux Etats-Unis. Les Micromegas sont des détecteurs gazeux robustes, rapides et bon marché. Ils doivent cependant être adaptés à l'environnement spécifique de CLAS12 car les défis sont nombreux : présence d'un champ magnétique fort, éloignement de l'électronique, fonctionnement avec un taux de hadrons élevé, nécessité de courber les détecteurs, espace disponible restreint. Ma thèse a commencé par des tests de détecteurs en faisceau au CERN qui ont permis d'estimer que le taux de décharges dans les Micromegas de CLAS12 serait de quelques Hertz. Une part importante de ce document est ainsi consacrée à l'étude de plusieurs méthodes innovantes dont l'objectif est de minimiser le temps mort dû aux décharges. J'ai donc mené des tests intensifs portant sur l'optimisation du filtre haute tension de la microgrille, l'introduction d'une feuille de GEM dans un Micromegas ou encore l'utilisation de Micromegas dits résistifs. Ces derniers donnant d'excellents résultats, des prototypes à l'échelle 1, dont l'un fabriqué par un industriel, ont été testés. La mécanique et le point de fonctionnement (gaz, tensions, géométrie...) des détecteurs ont ensuite été validés par des tests en laboratoire. Toutefois, afin de s'assurer un meilleur rapport signal sur bruit, des optimisations de la microgrille du détecteur ont été menées. Le CEA Saclay étant également responsable du développement de l'électronique des Micromegas pour CLAS12, j'ai comparé ses performances avec une autre électronique, vérifier sa résolution temporelle et déterminer le rapport signal sur bruit lorsque des limandes de 2 m connectent le détecteur à l'électronique. Les progrès réalisés dans le cadre de CLAS12 ont par ailleurs initié d'autres projets. J'ai ainsi effectué des simulations basées sur des pseudo-données pour valider la faisabilité d'une expérience portant sur les mésons exotiques pour laquelle nous avons proposé un trajectographe composé de Micromegas. / This thesis presents my work performed since 2010 to develop Micromegas detectors for the CLAS12 spectrometer that will be installed in the Hall B of Jefferson Laboratory (USA). The Micromegas are robust, fast and cheap gaseous detectors. Nevertheless, they must be adapted to the specific CLAS12 environment as there are many challenges to face : presence of a strong magnetic field, off-detector frontend electronics, high hadrons rate, necessity to curve the detectors, few space available. My PhD started by beam tests at CERN that allowed to evaluate the spark rate in CLAS12 Micromegas at a few Hertz. An important part of this document is therefore devoted to the study of several innovative methods to minimize the dead time induced by sparks. Thus, I have performed intensive tests on the optimization of the micromesh high voltage filter, with on Micromegas equipped with a GEM foild or on resistive Micromegas. The latter giving excellent results, full scale prototypes, one of which built by a company, have been tested. The mechanics and the working point (gas, voltages, geometry...) of the detectors have then be validated by laboratory tests. However, to ensure a better signal over noise ratio, the micromesh has been optimized. The CEA Saclay being also responsible for the development of the electronics for CLAS12 Micromegas, I have compared its performance with another electronics, verify its time resolution and determine the signal over noise ratio when 2 m long cables are connecting the electronics to the detector. The progress realized in the context of CLAS12 have furthermore triggered other projects. So, I have carried out simulations based on pseudo-data to validate the feasibility of a meson spectroscopy experiment for which we have proposed a Micromegas based tracker.
2

Réactions élastiques et inélastiques résonantes pour la caractérisation expérimentale de la cible active ACTAR TPC / Resonant elastic and inelastic scattering for the experimental characterization of the active target ACTAR TPC

Mauss, Benoit 05 October 2018 (has links)
ACTAR TPC (ACtive TARget and Time Projection Chamber) est une cible active de nouvelle génération construite au GANIL (Grand Accélérateur d'Ions Lourds). Les cibles actives sont des cibles gazeuses où le gaz permet de détecter le passage de particules chargées selon le principe des chambres à projection temporelle (TPC). La TPC d'ACTAR est formée d'une anode segmentée de 16384 pixels carrés de 2 mm de côté. La haute densité de voies est gérée par le système électronique GET (General Electronics for TPCs). Ce système digitalise également les signaux sur un intervalle de temps donné, pour une reconstruction 3D complète des évènements. Un démonstrateur huit fois plus petit a d'abord été construit pour vérifier le fonctionnement de l’électronique et la conception mécanique. La finalisation d’ACTAR TPC s’est basée sur les résultats du démonstrateur, qui a été testé avec des faisceaux de 6Li, de 24Mg et de 58Ni. Le commissioning d'ACTAR TPC a été effectué dans le cas de la diffusion résonante sur cible de protons avec des faisceaux de 18O et de 20Ne.Un algorithme de reconstruction des traces mesurées dans la TPC permet d'en extraire les angles et les énergies des ions impliqués dans les réactions. Les résultats sont comparés à des données connues pour déterminer les performances du système de détection. Les résolutions obtenues sur le commissioning à partir de calculs en matrice R valident l'utilisation d'ACTAR TPC pour de futures expériences. Par ailleurs, la diffusion résonante 6Li + 4He réalisée avec le démonstrateur a permis d'étudier les états d’agrégat alpha dans le 10B. Deux résonances à 8.58 MeV et 9.52 MeV sont observées pour la première fois en diffusion élastique dans cette voie de réaction. / ACTAR TPC (ACtive TARget and Time Projection Chamber) is a next generation active target that was designed and built at GANIL (Grand Accélérateur d'Ions Lourds). Active targets are gaseous targets in which the gas is also used to track charged particles following the principles of time projection chambers (TPC). The TPC of ACTAR has a segmented anode of 16384 2 mm side square pixels. The high density of pixels is processed using the GET (General Electronics for TPCs) electronic system. This system also digitizes the signals over a time interval, enabling a full 3D event reconstruction. An eight time smaller demonstrator was first built to verify the electronics operation and the mechanical design. ACTAR TPC's final design was based on results obtained with the demonstrator which was tested using 6Li, 24Mg and 58Ni beams. The commissioning of ACTAR TPC was then carried out for the case of resonant scattering on a proton target using 18O and 20Ne beams. A track reconstruction algorithm is used to extract the angles and energies of the ions involved in the reactions. Results are compared to previous data to determine the detection system performances. Comparing the commissioning data with R matrix calculations, excitation functions resolutions in different cases are obtained. The use of ACTAR TPC is validated for future experiments. Furthermore, alpha clustering was studied in 10B through the resonant scattering 6Li + 4He, carried out with the demonstrator. Two resonances at 8.58 MeV and 9.52 MeV are observed for the first time in elastic scattering with this reaction channel.