Commande et optimisation d'une installation multi-sources. / Control and Optimization of a Photovoltaic Installation.

Alotaibi, Lafi 30 March 2012 (has links)
Cette thèse traite la commande et l'optimisation d'une installation photovoltaïquepour un site isolé. Ainsi, nous avons proposé un algorithme par logique flouepermettant la poursuite du point de puissance maximal afin de remédier auxinconvénients des méthodes classiques. Ensuite, nous nous sommes intéressés àl'optimisation de la structure de l'installation. En effet, dans les installationsclassiques, dans le cas de défaillance d'un panneaux, tout le bloc série devientinutilisable, ce qui réduit considérablement les capacités de production del'installation. Pour résoudre ce problème, nous avons proposé un superviseur permettant la reconfiguration automatique de l'installation de telle sorte que seul lepanneaux défaillant est mis hors connexion. Par ailleurs, pour gérer le flux depuissance et pour répondre à la demande de l'utilisateur, nous avons développé un superviseur par logique floue. Ainsi, le surplus de production est stocké systématiquement dans la batterie pour l'utiliser ensuite en cas où la demandedépasse la production. De plus, la structure proposée permet de ne solliciter la batterie en cas de besoin de ce qui permet de prolonger considérablement sa duréede vie. / This thesis addresses the control and optimization of a stand-alone photovoltaicsystem. Thus, we proposed a fuzzy logic algorithm for tracking the maximum powerpoint to overcome the disadvantages of classical methods. Then we focused onoptimizing the structure of the installation. Indeed, in conventional systems, in thecase of failure of a panel, the whole serie block becomes unusable, greatly reducingthe production capacity. To resolve this problem, we proposed a supervisor for theautomatic reconfiguration of the installation so that only the failed panels is takenoffline. Furthermore, to manage the power flow and to meet user demand, wedeveloped a fuzzy supervisor. Thus, the surplus production is systematically storedin the battery for later use in cases where demand exceeds production. In addition,the proposed structure can not draining the battery in case of need thereby greatlyextend its lifetime.
2

Réalisation d'un système de conversion et de gestion de l'énergie d'un système photovoltaïque pour l'alimentation des réseaux de capteurs sans fil autonomes pour application aéronautique / Photovoltaic Power Generation and Management Strategies for a Wireless Sensor Network Deployed for Large Aircraft In-Flight Tests

Meekhun, Dariga 19 November 2010 (has links)
Le projet SACER vise à répondre aux demandes d’Airbus qui ont besoin de disposer de données décrivant le comportement d’un avion ou d’un satellite avant commercialisation ou lancement. Pour mieux répondre à cette demande, un réseau de capteurs sans fil remplacerait les équipements de test filaires existants. Le but est d’apporter des avantages tels qu’une réduction de poids, de coût et de connectique. Pour notre part, nous n’avons travaillé que sur l’application aéronautique.Pour alimenter les capteurs autonomes sans fil embarqués, dans le cadre de cette thèse, il faut concevoir une architecture de récupération d’énergie, un système de stockage de l’énergie ainsi que un circuit de gestion de ces énergies. La principale contrainte pour le système est qu’il doit pouvoir fonctionner de -50C à 100°C, tout en délivrant une puissance de sortie de 3 watts. De plus, l’épaisseur du système doit être inférieure à 3,2 mm.Pour notre travail, nous avons cherché, dans un premier temps, la meilleure solution possible sur le choix du type de cellules solaires. Le résultat sur les tests des cellules à différentes températures et irradiations dans les conditions de notre application est présenté. Dans un second temps, nous avons testé plusieurs types de systèmes de stockage d’énergie aux températures extrêmes. Enfin, la conception de l’architecture pour la gestion de l’énergie (vue d’ensemble des panneaux photovoltaïques, d’un circuit MPPT, des super condensateurs, et d’un régulateur) est présentée / Flight tests of a commercial aircraft consist in gathering data during flight to validate aircraft design. However they are very expensive for various reasons. One of them is that most of the sensors implemented to collect data are wired. As an example, for the sole system that monitors the vibrations onboard a large (more than 100 seats) aircraft, more than 100 sensors may be deployed. Such networks are complex to implement, mainly because of the required wiring. A wireless solution is therefore of great interest; however, such a cable-less implementation implies both wireless transmission of data together with energy autonomy.The purpose of this work is therefore to describe a design of a power generation system, focusing on photovoltaic, together with the associated management strategies for an autonomous wireless sensor network deployed for large aircraft in-flight tests. This work is a part of SACER project. The main requirements are related to the thickness of the system (less than 3,2mm in order not to disturb the aerodynamic air flow) and the output power (3 W per sensor node in order to power the sensor, data processing and transmission system). In addition, the system has to properly work at extremely high and low temperature (-50 to 100°C). Our system consists of three primary components to consider: Energy Harvesting system, Energy storage device and Energy management system.In this work, we firstly present the comparison of the performance of different photovoltaic technologies at different temperatures concerning their availability and achievable power density in aircraft applications. Secondly, we will investigate the possibility of using batteries and supercapacitor. Finally the power management system, composed by a photovoltaic panel, a power conditioning (MPPT function), supercapacitors and a DC/DC regulator, is presented
3

Contribution à la commande des systèmes photovoltaiques : application aux systèmes de pompages. / Contribution to the control of photovoltaic systems : application to pumping systems.

Abouda, Salim 14 April 2015 (has links)
L'objectif des travaux présentés dans cette thèse est d'apporter une contribution à l'étude d'un système photovoltaïque fonctionnant à sa puissance maximale et énergétiquement autonome. Le cas étudié, dans cette thèse, concerne la commande d'une chaine de pompage photovoltaïque dans un site isolé. Dans ce sens, et pour que le système photovoltaïque fonctionne à sa puissance maximale, il doit comporter un étage d'adaptation associé à un algorithme MPPT. Dans notre étude, nous avons utilisé deux algorithmes MPPT, l'algorithme “Perturb and Observe” (P&O) puis l'algorithme “ Increment of Conductance” (IncCond). Dans quelques applications industrielles, il est parfois nécessaire de maintenir la tension délivrée par le système photovoltaïque constante. Pour cela, un système de contrôle de cette tension est présenté. Les méthodes utilisées pour la simulation de ce système sont basées sur l'utilisation d'un régulateur PID, puis sur le contrôle par mode glissant, et enfin sur un contrôleur par logique floue. Ce système est testé pour une charge résistive puis pour le cas d'une pompe centrifuge entrainée par un moteur à courant continu à aimant permanent. Ensuite, nous avons étudié le cas d'une chaine de pompage utilisant un moteur asynchrone triphasé comme moteur d'entrainement. Dans le but d'avoir la possibilité de régler le débit d'eau, et en se basant sur la caractéristique de proportionnalité entre la vitesse et le débit, la méthode de contrôle direct du couple, Direct Torque Control - DTC est utilisée pour la commande de la vitesse du moteur asynchrone. / The aim of the work presented in this thesis is to contribute to the study of a photovoltaic system operating at its maximum power and energetically autonomous. The case studied in this thesis relates to the control of a chain of photovoltaic pumping in an isolated site. In this sense and for the PV system operates at its maximum power, it must include a converter associated with a MPPT algorithm. In our study, we used two MPPT algorithms, the algorithm “Perturb and Observe” (P & O), then the algorithm “Increment of Conductance” (IncCond). In some industrial applications, it is sometimes necessary to maintain the voltage delivered by the PV system constant. For this, a control system of this voltage is presented. The methods used for the simulation of this system are based on the use of a PID controller and the sliding mode control, and finally a fuzzy logic controller. This system was tested for a resistive load then for the case of a centrifugal pump driven by a permanent magnetic DC motor. Then we studied the case of a pumping chain using a three-phase induction motor as a drive motor. In order to be able to regulate the flow of water, the Direct Torque Control method “DTC” is used to control the speed of the induction motor because it is proportional with the water flow.
4

Design and Experimentation of Darrieus Vertical Axis Wind Turbines

Gonzalez Campos, Jose Alberto 07 September 2020 (has links)
No description available.
5

Ανάπτυξη δυναμικού μοντέλου και έλεγχος ανεμογεννήτριας συνδεδεμένης στο δίκτυο και σε αυτόνομη λειτουργία εφοδιασμένη με διάταξη αποθήκευσης ενέργειας

Δημητρακάκης, Στέφανος 18 June 2014 (has links)
Η παρούσα διπλωματική εργασία πραγματεύεται τη μελέτη και τη μοντελοποίηση ενός αιολικού συστήματος παραγωγής ηλεκτρικής ενέργειας βασισμένο σε σύγχρονη γεννήτρια μόνιμου μαγνήτη (PMSG). Ειδικότερα, παρουσιάζονται και αναλύονται όλα τα τμήματα που αποτελούν το αιολικό σύστημα καθώς και οι λογικές ελέγχου που ακολουθήθηκαν για την αποτελεσματική λειτουργία του. Επιπλέον, μελετάται και μοντελοποιείται μια διάταξη αποθήκευσης ενέργειας από την οποία πλαισιώνεται το αιολικό σύστημα κατά την αυτόνομη λειτουργία του. Τέλος, παρουσιάζονται και σχολιάζονται τα αποτελέσματα της προσομοίωσης της λειτουργίας του συστήματος, σε σύνδεση με το δίκτυο και κατά την αυτόνομη λειτουργία του. Για την ανάπτυξη του μοντέλου και την προσομοίωση χρησιμοποιήθηκε το πρόγραμμα Simulink/Matlab. Στο Κεφάλαιο 1 γίνεται αναφορά στο ενεργειακό πρόβλημα και μια γενική εισαγωγή στις ανανεώσιμες πηγές ενέργειας. Επιπλέον, δίνονται διάφορες πληροφορίες γύρω από την αιολική ενέργεια και αναλύονται τα πλεονεκτήματα και μειονεκτήματα της χρήσης ανεμογεννητριών. Επίσης, παρουσιάζεται η δομή μιας ανεμογεννήτριας και παραθέτονται διάφοροι τύποι ανεμογεννητριών, ενώ δίνονται και οι βασικές σχέσεις μετατροπής της αιολικής ενέργειας σε ηλεκτρική. Στο Κεφάλαιο 2 γίνεται ανάλυση κάθε τμήματος της ανεμογεννήτριας (πτερωτή, σύστημα μετάδοσης κίνησης, γεννήτρια) και παρατίθενται οι εξισώσεις που περιγράφουν τη λειτουργία τους. Επιπρόσθετα, παρουσιάζεται ο τρόπος μοντελοποίησης του κάθε τμήματος στο περιβάλλον του Simulink. Ιδιαίτερη έμφαση δόθηκε στη μελέτη της σύγχρονης γεννήτριας μόνιμου μαγνήτη καθώς παρουσιάζεται με λεπτομέρεια η δομή της καθώς και οι αρχές που διέπουν τη λειτουργία της. Τέλος, δίνονται όλα τα χαρακτηριστικά μεγέθη της ανεμογεννήτρια που χρησιμοποιήθηκε στην παρούσα εργασία. Στο Κεφάλαιο 3 αρχικά, γίνεται μια γενική παρουσίαση των στοιχείων που αποτελούν τους μετατροπείς, ενώ στη συνέχεια παρουσιάζονται οι βασικές κατηγορίες μετατροπέων που υπάρχουν και αναφέρονται μερικοί βασικοί τύποι μετατροπέων που βρίσκουν εφαρμογή σε αιολικά συστήματα γενικότερα. Έπειτα, το κεφάλαιο επικεντρώνεται στους μετατροπείς που χρησιμοποιήθηκαν στο αιολικό σύστημα της παρούσας εργασίας καθώς εξηγείται ο τρόπος λειτουργίας τους και παρουσιάζεται ο τρόπος μοντελοποίησης τους στο Simulink. Έμφαση δόθηκε στον dc/dc μετατροπέα ανύψωσης τάσης που χρησιμοποιήθηκε, όπου γίνεται διαστασιολόγηση και παρουσιάζεται μια μικρή προσομοίωση της λειτουργίας του. Τέλος, παρουσιάζεται, επίσης, το φίλτρο που τοποθετείται στην έξοδο του αντιστροφέα. Στο Κεφάλαιο 4 περιγράφονται αναλυτικά η τεχνική διαμόρφωσης εύρους παλμών (PWM) και η τεχνική της ημιτονοειδούς διαμόρφωσης εύρους παλμών (SPWM), οι οποίες και εφαρμόστηκαν για την παλμοδότηση των μετατροπέων. Στη συνέχεια, περιγράφονται αναλυτικά οι μηχανισμοί ελέγχου που εφαρμόστηκαν με τη βοήθεια PI ελεγκτών, τόσο στην πλευρά της μηχανής (dc/dc μετατροπέας ανύψωσης τάσης) όσο και στον αντιστροφέα του αιολικού συστήματος. Στο Κεφάλαιο 5 παρουσιάζονται και σχολιάζονται τα αποτελέσματα της προσομοίωσης του αιολικού συστήματος σε σύνδεση με το δίκτυο. Το σύστημα προσομοιώνεται για δύο περιπτώσεις, σε πρώτη φάση γίνεται προσομοίωση του συστήματος υπό σταθερή ταχύτητα ανέμου ίση με 12 m/s και σε δεύτερη φάση προσομοιώνεται η λειτουργία του συστήματος για βηματικές μεταβολές της ταχύτητας του ανέμου. Στο Κεφάλαιο 6 μελετάται η αυτόνομη λειτουργία του αιολικού συστήματος το οποίο, πλέον, πλαισιώνεται με μια διάταξη αποθήκευσης ενέργειας. Αρχικά, παρουσιάζεται το σύστημα αποθήκευσης ενέργειας που χρησιμοποιήθηκε. Συγκεκριμένα η συστοιχία μπαταριών της οποίας δίνονται τα χαρακτηριστικά μεγέθη, καθώς και το μοντέλο της στο Simulink. Επίσης, παρουσιάζεται και μοντελοποιείται ο dc/dc μετατροπέας δύο κατευθύνσεων ο οποίος συνδέει τη συστοιχία με το υπόλοιπο σύστημα. Στη συνέχεια, περιγράφεται αναλυτικά ο μηχανισμός ελέγχου που εφαρμόζεται στη διάταξη αποθήκευσης ενέργειας για τον έλεγχο της φόρτισης/εκφόρτισης. Στο τέλος του κεφαλαίου παρουσιάζονται τα αποτελέσματα της προσομοίωσης του αυτόνομου αιολικού συστήματος για σταθερή ταχύτητα ανέμου-μεταβαλλόμενο φορτίο και για μεταβαλλόμενο άνεμο-σταθερό φορτίο. / In this thesis, a wind energy conversion system (WECS) based on a permanent magnet synchronous generator (PMSG) was studied and simulated. All parts of the WECS are presented and discussed in detail. Furthermore, control strategies for the generator-side converter and the voltage source inverter are developed. The WECS is simulated both in grid connected and stand-alone mode. In the stand-alone mode, the WECS is supplied with an energy storage system for which a bi-directional buck/boost converter and control strategy was designed. Finally, simulation results are presented and performance of the system in various modes of operation is evaluated. Simulink/Matlab is used for modeling and simulating the WECS. At the beginning of Chapter 1, a discussion of energy crisis and renewable energy sources is held. Furthermore, information about wind energy has been reviewed and its benefits and drawbacks are examined. In addition, the structure of a wind turbine and the principles of converting wind energy into electricity are presented. In Chapter 2 all parts of the wind turbine are studied and its characteristics are specified. Even more, the model of every part in Simulink is presented. Theoretical background, structure and operation principles of PMSG are presented in detail. In Chapter 3, firstly a general presentation of converters components takes place. Then the major existing categories of converter are presented and some basic types of converters, which are generally used in WECS, are mentioned. Moreover, the chapter focuses on the converters that are used in this thesis, explaining the way they operate. After all, their models in Simulink are shown. Emphasis was given to the dc/dc boost converter whose parameters are calculated and its operation is simulated. Finally, there is a presentation of the filter which was placed at the output of the inverter. In Chapter 4, Pulse-width Modulation (PWM) and Sinusoidal Pulse-width Modulation (SPWM) techniques that are used in this thesis are described. Moreover, the control strategy for the generator-side converter with maximum power extraction is presented. The control strategy of the voltage sourced inverter is shown as well. In Chapter 5 simulation results of the grid connected WECS are presented and evaluated. On the first part of the presentation, the WECS is simulated for constant wind speed (12m/s), and in the second part for step-changed wind speed. In Chapter 6 the stand-alone operation of the WECS is studied and supplied with an energy storage system. Initially, there is an analysis of the energy storage system, which was used, and in particular the battery bank, whose characteristics are given. Moreover, a Bi-directional dc/dc Buck-Boost converter which is used to interconnect the battery bank to the dc-link is presented and modeled. Afterwards, there is a detailed description of the control strategy used in order to control charging / discharging of the battery bank. At the end of this chapter, simulation results of two different stand-alone operation modes are presented, one with constant wind speed and variable load and the other one with step-changing wind speed and constant load.