1

Avaliação da dose glandular e qualidade de imagem de pacientes submetidas a mamografias com processamento de imagem digital / EVALUATION OF MEAN GLANDULAR DOSE AND IMAGE QUALITY OF PATIENTS UNDERGOING MAMMOGRAPHY WITH DIGITAL IMAGE PROCESSING

Marcio Alves de Oliveira 30 August 2011 (has links)
Nenhuma / O câncer de mama é, nos dias de hoje, uma das maiores causas de morte entre as mulheres em todo o mundo, pois muitas vezes não são diagnosticados precocemente. Só no Brasil foram estimados, em 2010/2011, mais de 49 mil novos casos de câncer de mama. Por este motivo, a mamografia cresceu significativamente nos últimos anos. Porém, a mamografia é uma técnica de diagnóstico por imagem que necessita de um cuidado especial, pois radiografias sem qualidade adequada podem ocasionar um falso diagnóstico e, além disso, acarretar a necessidade de repetição do exame, aumentado a dose de radiação na paciente e o risco à indução de novos cânceres. Portanto, é necessário avaliar as doses em mamografia, pois estas devem ser mantidas tão baixas quanto possível, sem reduzir a elevada qualidade de imagem necessária para a detecção precoce do câncer de mama. Neste sentido, este estudo teve como objetivo, avaliar a dose glandular média e qualidade da imagem de pacientes submetidos a exames de rotina em mamografia com sistema de processamento digital na cidade de Belo Horizonte-MG. Para isso, foram selecionados dois serviços com sistemas de processamento digital distintos (FUJI e KODAK). Nestes foram avaliados qualidade de imagem clínica e dose glandular média a que as pacientes são submetidas. Como resultado, foi obtido para o serviço FUJI uma dose média de 1,82 mGy e 2,07 mGy 3,72% para os posicionamentos craniocaudal (CC) e médio lateral oblíqua (MLO), respectivamente. Enquanto que para o serviço KODAK as médias foram de 2,53 mGy e 2,85 mGy 3,72% para os posicionamentos CC e MLO, respectivamente. Portanto, conclui-se que os valores obtidos nesta pesquisa se apresentaram de 50 a 85% acima dos níveis de referência determinados por protocolos internacionais calculados com 50 mm de polimetilmetacrilato (PMMA), que podem estar superestimando a dose para baixas espessuras de mama e subestimando para altas espessuras. / Breast cancer is nowadays one of the biggest killers of women worldwide as they often are not diagnosed early. In Brazil was estimated in 2010/2011, more than 49 000 new cases of breast cancer. For this reason, the mammogram has increased significantly. However, mammography is a technique that requires special care, because poor quality images can cause a false diagnosis, and cause the need for repeat testing, increasing the radiation dose to the patient and the risk to the induction of new cancers. Therefore, it is necessary to evaluate the doses in mammography, as they should be kept as low as possible without reducing the image quality required for the early detection of breast cancer. Thus, this study aimed to evaluate the average glandular dose and image quality of patients undergoing routine screening mammography to digital processing system in the city of Belo Horizonte-MG. To this end, we selected two services with different digital processing systems (Fuji and Kodak). In these image quality were evaluated clinically and average glandular dose that patients are subjected. As a result, the FUJI service was obtained an average dose of 1.82 mGy and 2.07 mGy for the positions craniocaudal (CC) and oblique (MLO), respectively. While Kodak service, the averages were 2.53 mGy and 2.85 mGy for the CC and MLO positions, respectively. Therefore, we conclude that the values obtained in this research were presented from 50 to 85% above the limits set by international protocols calculated with polymethylmethacrylate (PMMA), which may be overestimating the dose to lower breast thickness and underestimated for high thicknesses.
2

Análise de parâmetros e controle da qualidade de sistemas de radiologia computadorizada para mamografia / Analyis of parameters and quality control in computed radiography systems for mammography

Frederico Ladeia Alvarenga 29 August 2008 (has links)
Nenhuma / O desenvolvimento e a consolidação de novas tecnologias na radiologia vêm se constituindo em uma estratégia permanente das empresas, uma vez que resulta em ganhos de produtividade, qualidade dos produtos e serviços, redução de custos, conscientização ambiental, eliminação de desperdícios, melhoria em atendimento e diagnósticos para os pacientes. O programa de controle da qualidade em mamografia é um instrumento para o gerenciamento da qualidade dos serviços que são oferecidos à população. A radiografia computadorizada (CR) em mamografia surge como uma importante ferramenta nas ações sistematizadas de controle do câncer de mama, na detecção precoce através de programas de rastreamento de segmentos populacionais, com exames periódicos. Para que se tenham mamografias de qualidade ótima na detecção do câncer de mama é necessário seguir critérios de qualidade da imagem e desempenho dos equipamentos. Os sistemas de radiografia computadorizada (CR) constituem um método eficiente e econômico de captura e conversão de radiografia em formato digital. Desde que as soluções digitais em mamografia vêm sendo utilizadas comercialmente, mostrou-se evidente que os sistemas de avaliação dos métodos analógicos não são apropriados para as tecnologias digitais. Por se tratar de um sistema novo no processo de aquisição de imagens médicas, ainda não se tem um método definido de avaliação estabelecido pelos órgãos reguladores nacionais. Os ensaios foram realizados no Laboratório de Calibração e Dosimetria do Centro de Desenvolvimento da Tecnologia Nuclear onde foi possível avaliar a cadeia da formação da imagem e parâmetros de qualidade da imagem como: contraste, resolução espacial, ruído, densidade ótica, razão sinal ruído, razão sinal contraste, distorção, artefatos e processamento. Esses parâmetros influenciam na capacidade de interpretação e visualização da imagem radiográfica, sendo estes determinantes para a tomada de decisão do diagnostico final. O propósito deste trabalho é o de analise de parâmetros e controle da qualidade de sistemas de radiologia computadorizada para mamografia a fim de apresentar indicadores que refletem a exposição à radiação em um detetor de imagem. O resultado final dos testes de caracterização do sistema digital avaliado foi satisfatório em todos os aspectos relativos à metodologia aplicada para avaliação dos testes, comprovando assim os benefícios dos sistemas digitais de aquisição de imagens médicas. O trabalho sugere um modelo de metodologia para avaliação do sistema de radiografia computadorizada em mamografia. / The development and the consolidation of new technologies in radiology became a permanent strategy of companies since they contribute to the increase of productivity, the upgrade of the quality of products and services, reduction of costs, environmental consciousness, elimination of waste and improvement of the diagnosis. The quality control program for mammography is an instrument for the management of the quality of services provided to the population. The Computed Radiography (CR) in mammography appears to be an important tool in the systematic actions for controlling the breast cancer; it also has an important role in the early detection through screening programs of population segments by periodic exams. Good mammography images are achieved if the criteria for image quality and equipment performance are complied with standards. The Computed Radiography systems are an efficient and economical method of capture and conversion of the diagnostic image to digital format. Since digital solutions in mammography have been used, it became evident that evaluation systems of analogical methods are not adequate to digital technologies. The CR is a new system for the acquisition process of medical images; therefore there are not yet standards with an established quality control evaluation method provided by national regulatory authority. Measurements were carried out in a CR of the Dosimetry and Calibration Laboratory of the Development Center of Nuclear Technology; it was possible to evaluate the image formation chain and image quality parameters as contrast, spatial resolution, noise, optical density, signal-noise ratio, signal-contrast ratio, distortion, test objects and processing method. The visualization and interpretation ability of the radiographic image are highly influenced by those parameters; they are determinant for taking decision of the final diagnostic. The purpose of this work was to analyze the image parameters and the quality control procedure of CR systems for mammography; indicators that reflect the radiation exposure in an image detector were recommended. The final result of the characterization tests in this digital system was statistically significant relative to all aspects to the applied methodology for tests evaluation, proving the benefits of this digital system for acquisition of medical images. This work suggests a methodology model for evaluating the computed radiography systems used for mammography purposes.
3

DOSE GLANDULAR E CONTROLE DE QUALIDADE DA IMAGEM EM SERVIÇOS DE MAMOGRAFIA COM SISTEMA DE RADIOGRAFIA COMPUTADORIZADA / GLANDULAR DOSE AND IMAGE QUALITY CONTROL IN MAMMOGRAPHY FACILITIES WITH COMPUTED RADIOGRAPHY SYSTEM

Marcelino Vicente de Almeida Dantas 05 March 2010 (has links)
O câncer de mama é o câncer mais comum entre as mulheres, e a detecção precoce é crucial para seu diagnóstico e tratamento. Atualmente, o método mais efetivo para a detecção precoce do câncer de mama é a mamografia, onde o sistema tela/filme é o padrão ouro. Entretanto, apesar do sistema tela/filme ter sido melhorado e otimizado ao longo dos anos, para imagens da mama, existem algumas limitações críticas, incluindo faixa de exposição, artefatos da imagem, problemas no processamento dos filmes, e inflexibilidade em processamento das imagens e gerenciamento dos filmes. Nos últimos anos, a mamografia digital tem sido introduzida nos programas de rastreamento do câncer, com o sistema tela/filme sendo gradualmente substituído. A radiografia computadorizada (computed radiography - CR), comumente conhecida também como photostimulable phosphor (PSP) ou storage phosphor, emprega placas de imagem reutilizáveis e computadores e programas associados para adquirir e mostrar as radiografias de projeção digital. Neste trabalho foi testado um modelo de protocolo para a realização do controle de qualidade de imagem e de avaliação de doses glandular em 19 instituições com sistemas de radiografia computadorizada em mamografia. O protocolo foi validado através de testes feitos no Laboratório de Radioproteção Aplicada à Mamografia (LARAM) do Centro de Desenvolvimento da Tecnologia Nuclear (CDTN). A avaliação visual da qualidade da imagem do phantom CDMAM mostrou que 53% dos serviços conseguiram produzir imagens de ótima qualidade. Já a avaliação automatizada da qualidade da imagem, através do software de análise cdcom.exe, mostrou que 57% das imagens eram de boa qualidade. O teste da linearidade do detector mostrou que a resposta do sistema CR é bastante linear, onde 95% dos serviços / Breast cancer is the most common cancer among women, and early detection is critical to its diagnosis and treatment. To date, the most effective method for early detection of breast cancer has been x-ray mammography for which the screen/film (SF) technique has been the gold standard. However, even though SF combinations have been improved and optimized over the years for breast imaging, there are some critical limitations, including a narrow exposure range, image artifacts, film processing problems, and inflexibility in image processing and film management. In recent years, digital mammography has been introduced in cancer screening programmes with the screen/film techniques gradually being phased out. Computed radiography (CR), also commonly known as photostimulable phosphor (PSP) imaging or storage phosphor, employs reusable imaging plates and associated hardware and software to acquire and to display digital projection radiographs. In this work, a protocol model was tested for performing image quality control and average glandular dose (AGD) evaluation in 19 institutions with computed radiography systems for mammography. The protocol was validated through tests at the Laboratório de Radioproteção Aplicada à Mamografia (LARAM) from the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN). The image quality visual evaluation of CDMAM phantom showed that 53% of the facilities were able to produce images of excellent quality. Furthermore, the automated evaluation of image quality, using the analyze software cdcom.exe, showed that 57% of the images were considered to be of good quality. The detector linearity test showed that the CR response is very linear, where 95% of facilities evaluated were considered to be compliant. For the image noise was found that only 20% of facilities are in agreement with the parameters established for this test.