1

Evaluation of design provisions for in-plane shear in masonry walls

Davis, Courtney Lynn, January 2008 (has links) (PDF)
Thesis (M.S. in civil engineering)--Washington State University, December 2008. / Title from PDF title page (viewed on Feb. 19, 2009). "Department of Civil and Environmental Engineering." Includes bibliographical references (p. 56-57).
2

Evaluation of masonry wall performance under cyclic loading

Vaughan, Timothy Phillips. January 2010 (has links) (PDF)
Thesis (M.S. in civil engineering)--Washington State University, May 2010. / Title from PDF title page (viewed on July 14, 2010). "Department of Civil and Environmental Engineering." Includes bibliographical references (p. 72-73).
3

Behavior and vulnerability of reinforced masonry shear walls /

Minaie, Ehsan. Moon, Franklin. January 2009 (has links)
Thesis (Ph.D.)--Drexel University, 2009. / Includes abstract and vita. Includes bibliographical references (leaves 363-370).
4

Performance of lap splices in concrete masonry shear walls

Mjelde, Jon Zachery, January 2008 (has links) (PDF)
Thesis (M.S. in civil engineering)--Washington State University, May 2008. / Includes bibliographical references (p. 53-54).
5

Seismic Performance Quantification of Reinforced Concrete Shear Walls with Different End Configurations: Experimental Assessment and Data-driven Performance Models

El-Azizy, Omar January 2022 (has links)
Well-detailed reinforced concrete (RC) shear walls did not achieve the expected seismic performance in the 2011 Christchurch earthquake as per the Canterbury earthquake royal commission report. Similarly, RC shear walls showed low seismic performance in the 2010 Maule earthquake. The two major seismic events intrigued this research dissertation, where six half-scaled RC shear walls were constructed and tested. The six walls were split into two phases, each phase had different end configurations (i.e., rectangular, flanged, and boundary elements). Phase II RC walls had 2.4 times the vertical reinforcement ratio of Phase I walls. The walls were detailed as per CSA A23.3-19, and they were tested laterally under a quasi-static cyclic fully-reversed loading while maintaining a constant axial load through the full test of the walls. The overall seismic performance of the six walls is evaluated in Chapters 2 and 3 in terms of their load-displacement relationships, crack patterns, displacement ductility capacities, stiffness degradation trends, curvature profiles, end strains, energy dissipation capabilities, and equivalent viscous damping ratios. In addition, damage states are specified according to the Federal Emergency Management Assessment (FEMA P58) guidelines. The results came in agreement with the Canterbury earthquake royal commission report, where the test walls with low vertical reinforcement ratios showed lower-than-expected seismic performance due to the concentration of their plastic hinges at the primary crack locations. Moreover, the results validated the Christchurch (2011) and Maule (2010) earthquake findings as concentrating the rebars at the end zones and providing adequate confinement enhanced the seismic performance of the test walls, which was the case for Phase II flanged and boundary element walls. The displacement ductility variations of the test walls inspired the work of Chapter 4, where the objective is to develop a data-driven expression for RC shear walls to better quantify their displacement ductility capacities. In this respect, an analytical model is developed and experimentally validated using several RC walls. The analytical model is then used to generate a dataset of RC walls with a wide range of geometrical configurations and design parameters, including cross-sectional properties, aspect ratios, axial loads, vertical reinforcement ratio, and concrete compressive strengths. This dataset is utilized to develop two data-driven prediction expressions for the displacement ductility of RC walls with rectangular and flanged/boundary element end configurations. The developed data-driven expressions accurately predicted the displacement ductility of such walls and they should be adopted by relevant building codes and design standards, instead of assigning a single ductility-related modification factor for all ductile RC shear walls, as per the 2020 National Building Code of Canada. Several researchers tested well-detailed Reinforced Masonry (RM) shear walls and the results concluded that RM shear walls showed high seismic performance similar to that of RC shear walls. This intrigued the research efforts presented in Chapter 5, where a comparative analysis is performed between the six RC walls tested in this dissertation and three RM walls tested in a previous experimental program. The analysis focuses on comparing the seismic performance of both wall systems in terms of their crack patterns, load-displacement envelopes, curvature profiles, displacement ductility, normalized periods, and equivalent viscous damping ratios. In addition, an economic assessment is performed to compare such RC and RM shear walls using their total rebar weights and the total construction costs. Overall, RM shear walls achieved an acceptable seismic performance coupled with low rebar weights and low construction costs when compared to their RC counterparts. / Thesis / Doctor of Philosophy (PhD)
6

Behaviour Of FRP Strengthened Masonry In Compression And Shear

Pavan, G S 03 1900 (has links) (PDF)
Masonry structures constitute a significant portion of building stock worldwide. Seismic performance of unreinforced masonry has been far from satisfactory. Masonry is purported to be a major source of hazard during earthquakes by reconnaissance surveys conducted aftermath of an earthquake. Reasons for the poor performance of masonry structures are more than one namely lack of deformational capacity, poor tensile strength & lack of earthquake resistance features coupled with poor quality control and large variation in strength of materials employed. Fibre Reinforced Plastic (FRP) composites have emerged as an efficient strengthening technique for reinforced concrete structures over the past two decades. Present thesis is focused towards analysing the behaviour of Fibre Reinforced Plastic (FRP) strengthened masonry under axial compression and in-plane shear loading. Determination of in-planes hear resistance of large masonry panels requires tremendous effort in terms of cost, labour and time. Masonry assemblages like prisms and triplets that represent the state of stress present in masonry walls and masonry in-fills when under the action of in-planes hear forces present an alternative option for research and analysis purposes. Hence, present research is focused towards analysing the performance of FRP strengthened masonry assemblages and unreinforced masonry assemblages. Chapter1 provides a brief review on the behaviour of masonry shear walls and masonry in-fills under the action of in-plane shear forces in addition to the performance of masonry structures during past earthquakes. Review of available literature on FRP confinement of masonry prisms with bed joints inclined from 00 to 900 to the loading axis under axial compression, analytical models available for FRP confined concrete, shear strength of masonry triplets attached with FRP is presented. Chapter 2 primarily focuses on determining the various properties of the materials involved in this research investigation. Test procedure and results of the tests conducted to determine the mechanical and related properties of the materials involved are presented. Elastic properties and stress-strain response of burnt clay brick, mortar and FRP laminates are presented. Studies conducted on behaviour of GFRP confined masonry prisms under monotonic axial compression are included in Chapter 3. The study comprised of testing masonry prisms, both unconfined and FRP confined masonry prisms under axial compression. Stretcher bond and English bond prisms, with bed joints normal and parallel to loading axis are included in this study. Two grades of GFRP,360g/m2 and 600 g/m2 are employed to confine masonry prisms. The experimental program involved masonry prism types that accounted for variations in masonry bonding pattern, bed joint inclination to the loading axis and grade of GFRP. Review of the available analytical models predicting compressive strength of FRP confined masonry prism is presented. Available models for FRP confinement of masonry are re-calibrated using the present experimental data generating new coefficients for the already existing model to develop new expression for predicting the compressive strength of FRP confined prisms. In addition to the prism types mentioned earlier, behaviour of unconfined and GFRP confined stretcher bond prisms with bed joints inclined at 300, 450 & 600 to the loading axis are further investigated. Chapter 4 primarily deals with the shear strength and deformational capacity of masonry triplets that represent joint shear failure in masonry. An experimental program involving masonry triplets attached with different types of FRP(GFRP and CFRP), grade of FRP, percentage area covered by FRP and reinforcement pattern is executed. This exercise determined the influence of these parameters over the enhancement achieved in terms of shear strength and ultimate displacement. Results of tests conducted on stretcher bond prisms presented in chapter 3 and results of tests on shear triplets presented in this chapter are combined to study the interaction between shear and normal stresses acting along the masonry bed joint at different angles of inclination. The thesis culminated with chapter 5 as concluding remarks highlighting the salient Information pertaining to the behaviour of FRP strengthened masonry under axial compression and in-plane shear loading obtained as an outcome of the research conducted as a part of this thesis.

Page generated in 0.0415 seconds