• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etude de faisabilité de l'estimation non-invasive de la fonction d'entrée artérielle B+ pour l'imagerie TEP chez l'homme

Hubert, Xavier 08 December 2009 (has links) (PDF)
Cette thèse traite de l'estimation de la concentration dans le sang artériel de molécules marquées par un radioélément émettant des positons. Cette concentration est appelée « fonction d'entrée artérielle B+ ». Elle doit être déterminée dans de nombreuses analyses en pharmacocinétique. Actuellement, elle est mesurée à l'aide d'une série de prélèvements artériels, méthode précise mais nécessitant un protocole contraignant. Des complications liées au caractère invasif de la méthode peuvent survenir (hématomes, infections nosocomiales).L'objectif de cette thèse est de s'affranchir de ses prélèvements artériels par l'estimation non-invasive de la fonction d'entrée B+ à l'aide d'un détecteur externe et d'un collimateur. Cela permet la reconstruction des vaisseaux sanguins afin de discriminer le signal artériel du signal contenu dans les autres tissus avoisinants. Les collimateurs utilisés en imagerie médicale ne sont pas adaptés à l'estimation de la fonction d'entrée artérielle B+ car leur sensibilité est très faible. Pour cette thèse, ils sont remplacés par des collimateurs codés, issus de la recherche en astronomie. De nouvelles méthodes pour utiliser des collimateurs à ouverture codée avec des algorithmes statistiques de reconstruction sont présentées.Des techniques de lancer de rayons et une méthode d'accélération de la convergence des reconstructions sont proposées. Une méthode de décomposition spatio-temporelle est également mise au point pour estimer efficacement la fonction d'entrée artérielle à partir d'une série d'acquisitions temporelles.Cette thèse montre qu'il est possible d'améliorer le compromis entre sensibilité et résolution spatiale en tomographie d'émission à l'aide de masques codés et d'algorithmes statistiques de reconstruction ; elle fournit également les outils nécessaires à la réalisation de tellesreconstructions.
2

Development of a portable gamma camera for accurate 3-D localization of radioactive hotspots / Dévelοppement d'une caméra gamma pοrtable pοur la lοcalisatiοn précise en trois dimensiοns de pοints chauds radiοactifs

Paradiso, Vincenzo 31 March 2017 (has links)
Le présent travail a pour but le développement d’une caméra gamma à masque codé permettant d’estimer la position tridimensionnelle (3D) des sources radioactives. Cela est d’un intérêt considérable dans le cadre d’un grand nombre d'applications, de la reconstruction de la forme 3D des objets radioactifs aux systèmes de réalité augmentée appliqués à la radioprotection. Les caméras gamma portables actuelles ne fournissent que la position angulaire relative des sources gamma à localiser, c'est-à-dire qu'aucune information métrique concernant les sources n’est disponible, comme par exemple leur distance par rapport à la caméra. Dans cette thèse, nous proposons principalement deux approches permettant d’estimer la position 3D des sources. La première approche consiste à étalonner la caméra gamma avec un capteur de profondeur à lumière structurée. La seconde approche permet d'estimer la distance source-détecteur par une méthode d’imagerie gamma stéréoscopique. Pour aligner géométriquement les images obtenues par la caméra gamma, le capteur de profondeur, et la caméra optique, une procédure d'étalonnage n’utilisant qu’une seule source ponctuelle radioactive a été conçue et mise en œuvre. Les résultats expérimentaux démontrent que les approches proposées permettent d'obtenir une précision inférieure au pixel, tant pour l’erreur de reprojection que pour la superposition des images gamma et optiques. Ces travaux présentent également une analyse quantitative de la précision et de la résolution relatives à l’estimation de la distance source-détecteur. De plus, les résultats obtenus ont validé le choix de la géométrie du modèle sténopé pour les caméras gamma à masque codé. / A coded aperture gamma camera for retrieving the three-dimensional (3-D) position of radioactive sources is presented. This is of considerable interest for a wide number of applications, ranging from the reconstruction of the 3-D shape of radioactive objects to augmented reality systems. Current portable γ-cameras only provide the relative angular position of the hotspots within their field of view. That is, they do not provide any metric information concerning the located sources. In this study, we propose two approaches to estimate the distance of the surrounding hotspots, and to autonomously determine if they are occluded by an object. The first consists in combining and accurately calibrating the gamma camera with a structured-light depth sensor. The second approach allows the estimation of the source-detector distance by means of stereo gamma imaging. To geometrically align the images obtained by the gamma, depth, and optical cameras used, a versatile calibration procedure has been designed and carried out. Such procedure uses a calibration phantom intentionally easy to build and inexpensive, allowing the procedure to be performed with only one radioactive point source. Experimental results showed that our calibration procedure yields to sub-pixel accuracy both in the re-projection error and the overlay of radiation and optical images. A quantitative analysis concerning the accuracy and resolution of the retrieved source-detector distance is also provided, along with an insight into the respective most influential factors. Moreover, the results obtained validated the choice of the geometry of the pinhole model for a coded aperture gamma camera.
3

Etude de faisabilité de l'estimation non-invasive de la fonction d'entrée artérielle B+ pour l'imagerie TEP chez l'homme / Feasibility study of the non-invasive estimation of the b+ arterial input function for human PET imaging

Hubert, Xavier 08 December 2009 (has links)
Cette thèse traite de l'estimation de la concentration dans le sang artériel de molécules marquées par un radioélément émettant des positons. Cette concentration est appelée « fonction d'entrée artérielle B+ ». Elle doit être déterminée dans de nombreuses analyses en pharmacocinétique. Actuellement, elle est mesurée à l'aide d'une série de prélèvements artériels, méthode précise mais nécessitant un protocole contraignant. Des complications liées au caractère invasif de la méthode peuvent survenir (hématomes, infections nosocomiales).L'objectif de cette thèse est de s'affranchir de ses prélèvements artériels par l'estimation non-invasive de la fonction d'entrée B+ à l'aide d'un détecteur externe et d'un collimateur. Cela permet la reconstruction des vaisseaux sanguins afin de discriminer le signal artériel du signal contenu dans les autres tissus avoisinants. Les collimateurs utilisés en imagerie médicale ne sont pas adaptés à l'estimation de la fonction d'entrée artérielle B+ car leur sensibilité est très faible. Pour cette thèse, ils sont remplacés par des collimateurs codés, issus de la recherche en astronomie. De nouvelles méthodes pour utiliser des collimateurs à ouverture codée avec des algorithmes statistiques de reconstruction sont présentées.Des techniques de lancer de rayons et une méthode d'accélération de la convergence des reconstructions sont proposées. Une méthode de décomposition spatio-temporelle est également mise au point pour estimer efficacement la fonction d'entrée artérielle à partir d'une série d'acquisitions temporelles.Cette thèse montre qu'il est possible d'améliorer le compromis entre sensibilité et résolution spatiale en tomographie d'émission à l'aide de masques codés et d'algorithmes statistiques de reconstruction ; elle fournit également les outils nécessaires à la réalisation de tellesreconstructions. / This work deals with the estimation of the concentration of molecules in arterial blood which are labelled with positron-emitting radioelements. This concentration is called “ B+ arterial input function”. This concentration has to be estimated for a large number of pharmacokinetic analyses. Nowadays it is measured through series of arterial sampling, which is an accurate method but requiring a stringent protocol. Complications might occur during arterial blood sampling because this method is invasive (hematomes, nosocomial infections).The objective of this work is to overcome this risk through a non-invasive estimation of B+ input function with an external detector and a collimator. This allows the reconstruction of blood vessels and thus the discrimination of arterial signal from signals in other tissues.Collimators in medical imaging are not adapted to estimate B+ input function because their sensitivity is very low. During this work, they are replaced by coded-aperture collimators, originally developed for astronomy.New methods where coded apertures are used with statistical reconstruction algorithms are presented. Techniques for analytical ray-tracing and for the acceleration of reconstructions are proposed. A new method which decomposes reconstructions on temporal sets and on spatial sets is also developped to efficiently estimate arterial input function from series of temporal acquisitions.This work demonstrates that the trade-off between sensitivity and spatial resolution in PET can be improved thanks to coded aperture collimators and statistical reconstruction algorithm; it also provides new tools to implement such improvements.

Page generated in 0.0502 seconds