• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Développement d'un capteur de gaz à transduction microonde / Development of a microwave transduction gas sensor

Barochi, Guillaume 11 July 2013 (has links)
Ce mémoire présente les recherches effectuées sur une nouvelle méthode de transduction, exploitant la propagation des ondes à haute fréquence, pour la détection de polluants atmosphériques. Dans un premier temps, les principaux modes de transduction exploités dans les capteurs existants sont présentés. Ils fonctionnent dans des gammes de fréquences différentes des microondes, afin de comprendre ce que peut apporter cette nouvelle transduction. La permittivité diélectrique est le principal paramètre physique responsable de la détection microonde. Cependant, la variation de la conductivité du matériau sensible modifie également la transmission de l'onde à travers le dispositif microonde. Les propriétés de propagation d'une onde sont formulées afin de comprendre comment l'onde est influencée par la propagation dans le matériau sensible et comment sa mesure est effectuée. Le traitement des données joue un rôle important dans la détermination de la réponse des capteurs. Les matériaux inorganiques (oxydes d'étain et de titane) ont permis de valider les modes de transduction. Différentes géométries de capteurs ont été modélisées et utilisées avec des poudres compressées et des films minces, en particulier avec un matériau moléculaire (phtalocyanine de cobalt). Ces études nous ont permis d'améliorer la transduction, grâce à l'évolution du format de la structure microonde. Cette évolution a permis d'obtenir une discrimination meilleure que 100 ppm pour l'ammoniac dans l'argon ou dans l'air, et ce à température ambiante. / In this work, we have developed a new gas-sensing transduction based on the propagation of microwave inside a sensitive material to detect atmospheric pollutants at room temperature. First, we present a short overview of the main gas-sensing transduction in the litterature. These techniques operate in frequency ranges different from microwaves. The dielectric permittivity is the main physical parameter in the microwave transduction. The principle is based on the excitation of a sensitive material by a microwave electromagnetic field in a propagative structure. The reflected wave is specific to the excitation's frequency. It depends on the interaction between the sensitive material and the pollutant gas and also on the geometry of the sensor. However, the variation of the conductivity of the sensitive material also changes the transmission of the wave through the microwave device. Inorganic materials (tin and titanium oxides) are used to validate the methods of transduction. Different geometries of sensor are studied with electromagnetic modeling and experimental testing. The sensitive material is used in compressed powders and thin films, in particular with a molecular material (cobalt phthalocyanine). This work improves the microwave transduction knowledge by the sensor geometries. The experimental tests in argon flux conduct to obtain a resolution better than 100 ppm. Few results are presented in air flux.
2

Effet de l'humidité sur la réponse à l'ammoniac de capteurs conductimétriques à base de matériaux moléculaires / Humidity effect on the response to ammonia of conductimetric sensors made of molecular materials

Sizun, Thibaut 02 October 2012 (has links)
De nombreux capteurs d'ammoniac existent, mais la prise en compte de l'effet de l'humidité sur la mesure capteur est rarement assurée, y compris chez les fabricants. L'objectif de cette thèse est de proposer un transducteur conductimétrique capable de mesurer le taux d'ammoniac de façon sélective, avec une précision suffisante, pour une application au contrôle de la qualité de l'air dans un environnement à taux d'humidité variable. Le moyen employé pour atteindre cet objectif est l'utilisation de résistors à base de phtalocyanines de cobalt, sous forme de films minces, comme matériaux semi-conducteurs. L'étude porte sur la mise en forme de ces films minces réalisés par évaporation sous vide, évaporation de solvant et électrodéposition. Des bancs de mesures automatisés ont été mis en place pour effectuer les mesures électriques sous argon et pour étudierles réponses à l'ammoniac sec ou humide en appliquant des cycles exposition / repos. A partir de ces cycles de 1 min et 4 min, des réponses relatives sont calculées pour obtenir des valeurs proportionnelles aux concentrations d'ammoniac. Les effets de l'humidité seule et de l'ozone ont également été étudiés. Des tests sur la sensibilité croisée ammoniac / humidité ont été réalisés sur quatre résistors différents, dans des gammes de concentration allant de 25 à 90 ppm et dans des gammes d'humidité allant de 0 à 80% d'HR, à température ambiante. Deux d'entre eux, un résistor de phtalocyanine de cobalt (PcCo) et un résistor hybride de phtalocyanine de cobalt sulfonée /polypyrrole (s-PcCo/PPy), ont donné des résultats particulièrement intéressants.PcCo permet de discriminer des concentrations de 25, 45 et 90 ppm d'ammoniac dans une gammede 20 à 60% d'HR, avec une réponse relative de 40% à 45 ppm. De plus, mêmes si les RRs à 80%d'HR divergent légèrement, la discrimination est toujours possible entre les différentesconcentrations de NH3.s-PcCo / PPy est moins sensible à l'ammoniac, mais son étude a permis de démontrer que l'ajout dephtalocyanine dans une matrice polypyrrole augmente la sensibilité de ce matériau. Il donne uneréponse relative de 3,3% à 45 ppm. Cependant, la gamme d'humidité couverte est plus large, allant de 20 à 80% d'HR.Cette étude a donc permis de comparer des matériaux et d'estimer leur potentiel pour des applications au contrôle de la qualité de l'air avec différents taux d'humidité / Many ammonia sensors are available but the consideration of the humidity effect is scarcely insured even by manufacturers. The aim of this thesis is to propose a conductimetric transducer capable tomeasure ammonia selectively, with enough accuracy for air quality control, in a variable humidity environment. To reach this goal, we used thin film resistors made of cobalt phthalocyanines as semiconductor. This study deals with thin films processing made by vacuum evaporation, solventcast and electrodeposition. Automated workbenches were developed to perform electrical measurements under argon and to study the response of sensors to dry or humid ammonia by meansof 1 min / 4 min-long exposure / recovery cycles. From those cycles, relative responses are calculated to obtain values proportional to ammonia concentrations. The humidity and ozone effects are also studied independently as well. Ammonia / humidity cross sensitivity tests are made with four different resistors exposed to ammonia concentration in a 25-90 ppm range and in a 0-80%relative humidity range, under ambient temperature. Two of them, a cobalt phthalocyanine (CoPc)resistor and a hybrid resistor made of sulfonated cobalt phthalocyanine / polypyrrole (s-CoPc/PPy)gave interesting results.CoPc allows to discriminate 25, 45 and 90 ppm ammonia concentrations under 20-60% RH range,with a relative response of 40% at 45 ppm. Moreover, even if the RRs at 80% RH shift slightly, it isstill possible to discriminate the different concentrations.s-CoPc / PPy is less sensitive to ammonia but its study allowed to show that adding phthalocyaninein a PPy matrix enhances the sensitivity of this material and gives a RR of 3.3% at 45 ppm.However, the covered humidity range is larger, from 20 to 80% RH. Thus, this study allows to compare molecular materials and estimate their potential for air quality control applications with different humidity levels
3

Développement d'un capteur de gaz à transduction microonde

Barochi, Guillaume 11 July 2013 (has links) (PDF)
Ce mémoire présente les recherches effectuées sur une nouvelle méthode de transduction, exploitant la propagation des ondes à haute fréquence, pour la détection de polluants atmosphériques. Dans un premier temps, les principaux modes de transduction exploités dans les capteurs existants sont présentés. Ils fonctionnent dans des gammes de fréquences différentes des microondes, afin de comprendre ce que peut apporter cette nouvelle transduction. La permittivité diélectrique est le principal paramètre physique responsable de la détection microonde. Cependant, la variation de la conductivité du matériau sensible modifie également la transmission de l'onde à travers le dispositif microonde. Les propriétés de propagation d'une onde sont formulées afin de comprendre comment l'onde est influencée par la propagation dans le matériau sensible et comment sa mesure est effectuée. Le traitement des données joue un rôle important dans la détermination de la réponse des capteurs. Les matériaux inorganiques (oxydes d'étain et de titane) ont permis de valider les modes de transduction. Différentes géométries de capteurs ont été modélisées et utilisées avec des poudres compressées et des films minces, en particulier avec un matériau moléculaire (phtalocyanine de cobalt). Ces études nous ont permis d'améliorer la transduction, grâce à l'évolution du format de la structure microonde. Cette évolution a permis d'obtenir une discrimination meilleure que 100 ppm pour l'ammoniac dans l'argon ou dans l'air, et ce à température ambiante.
4

Effet de l'humidité sur la réponse à l'ammoniac de capteurs conductimétriques à base de matériaux moléculaires

Sizun, Thibaut 02 October 2012 (has links) (PDF)
De nombreux capteurs d'ammoniac existent, mais la prise en compte de l'effet de l'humidité sur la mesure capteur est rarement assurée, y compris chez les fabricants. L'objectif de cette thèse est de proposer un transducteur conductimétrique capable de mesurer le taux d'ammoniac de façon sélective, avec une précision suffisante, pour une application au contrôle de la qualité de l'air dans un environnement à taux d'humidité variable. Le moyen employé pour atteindre cet objectif est l'utilisation de résistors à base de phtalocyanines de cobalt, sous forme de films minces, comme matériaux semi-conducteurs. L'étude porte sur la mise en forme de ces films minces réalisés par évaporation sous vide, évaporation de solvant et électrodéposition. Des bancs de mesures automatisés ont été mis en place pour effectuer les mesures électriques sous argon et pour étudierles réponses à l'ammoniac sec ou humide en appliquant des cycles exposition / repos. A partir de ces cycles de 1 min et 4 min, des réponses relatives sont calculées pour obtenir des valeurs proportionnelles aux concentrations d'ammoniac. Les effets de l'humidité seule et de l'ozone ont également été étudiés. Des tests sur la sensibilité croisée ammoniac / humidité ont été réalisés sur quatre résistors différents, dans des gammes de concentration allant de 25 à 90 ppm et dans des gammes d'humidité allant de 0 à 80% d'HR, à température ambiante. Deux d'entre eux, un résistor de phtalocyanine de cobalt (PcCo) et un résistor hybride de phtalocyanine de cobalt sulfonée /polypyrrole (s-PcCo/PPy), ont donné des résultats particulièrement intéressants.PcCo permet de discriminer des concentrations de 25, 45 et 90 ppm d'ammoniac dans une gammede 20 à 60% d'HR, avec une réponse relative de 40% à 45 ppm. De plus, mêmes si les RRs à 80%d'HR divergent légèrement, la discrimination est toujours possible entre les différentesconcentrations de NH3.s-PcCo / PPy est moins sensible à l'ammoniac, mais son étude a permis de démontrer que l'ajout dephtalocyanine dans une matrice polypyrrole augmente la sensibilité de ce matériau. Il donne uneréponse relative de 3,3% à 45 ppm. Cependant, la gamme d'humidité couverte est plus large, allant de 20 à 80% d'HR.Cette étude a donc permis de comparer des matériaux et d'estimer leur potentiel pour des applications au contrôle de la qualité de l'air avec différents taux d'humidité

Page generated in 0.0361 seconds