• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeitos dos erros de projeção sobre as grandezas cefalométricas das análises de Steiner e McNamara

Sakima, Paulo Roberto Tatsuo [UNESP] 18 April 2001 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-04-18Bitstream added on 2014-06-13T20:17:29Z : No. of bitstreams: 1 sakima_prt_me_arafo.pdf: 509492 bytes, checksum: 030daa33044ab67488b563f5e1934473 (MD5) / Desde o desenvolvimento do método cefalométrico radiológico por Broadbent, em 1931, estuda-se meios para se minimizar os efeitos de seus erros. Os erros de projeção foram descritos desde os primeiros trabalhos em cefalometria, porém seu conhecimento não é completo. Assim, o objetivo desse trabalho foi analisar os efeitos dos erros de projeção sobre os dados das análises cefalométricas de Steiner e de McNamara. Para isso, estudou-se uma amostra de vinte telerradiografias em norma lateral tomadas de pacientes sem problemas marcantes de simetria, e feitas em aparelhos radiográficos com especificações idênticas. Aplicou-se um tratamento de correção da ampliação da imagem radiográfica e outro para estimar as posições dos pontos médios de estruturas pares bilaterais e simétricas, e comparou-se esses valores com aqueles obtidos de forma convencional (sem correção dos erros de projeção). Nessas comparações utilizou-se teste t de Student para amostras correlatas. Observou-se que as grandezas cefalométricas angulares não sofreram influência da correção da ampliação da imagem; as grandezas lineares sofreram aumento na mesma proporção do grau de ampliação da imagem radiográfica; e os diferentes tratamentos dados a pontos bilaterais trouxeram resultados diferentes. Concluiu-se que a influência dos erros de projeção sobre as grandezas cefalométricas foi significante. / Since Broadbent introduced cephalometric radiology method, in 1931, means are studied for minimizing its errors and effects. Projection errors are discussed since the first studies in cephalometry, but their consequences are not thoroughly understood. The object of this research work is to analyze projection errors effects on linear and angular measurements from Steiner and McNamara cephalograms. A sample of twenty lateral radiographs from patients with no symmetry problem was studied; each radiograph was taken on radiographic systems with identical specifications. Two treatments were analyzed: one for magnification correction and other to minimize distortion effects on symmetric anatomical structures. These treatments brought values that were compared to those obtained in a conventional way (with no correction for projection errors). These statistical comparisons were performed by Student's t test for paired samples. The following observations were found: angular measurements were not influenced by magnification correction; linear measurements were increased in the same proportion as the magnification factor for that radiographic system; and, results were influenced by the way bilateral points were handled. This research work conclusion was that changes from the correction of projection errors were significant.
2

A statistical approach identifying and limiting the effect of influential observations in linear regression

Jones, Tamekia L. January 2008 (has links) (PDF)
Thesis (Ph.D.)--University of Alabama at Birmingham, 2008. / Title from first page of PDF file (viewed on June 25, 2009). Includes bibliographical references.
3

Efeitos dos erros de projeção sobre as grandezas cefalométricas das análises de Steiner e McNamara /

Sakima, Paulo Roberto Tatsuo. January 2001 (has links)
Orientador: João Roberto Gonçalves, Joel Claudio da Rosa Martins / Banca: Ary dos Santos Pinto / Banca: Guilherme dos Reis Pereira Janson / Resumo: Desde o desenvolvimento do método cefalométrico radiológico por Broadbent, em 1931, estuda-se meios para se minimizar os efeitos de seus erros. Os erros de projeção foram descritos desde os primeiros trabalhos em cefalometria, porém seu conhecimento não é completo. Assim, o objetivo desse trabalho foi analisar os efeitos dos erros de projeção sobre os dados das análises cefalométricas de Steiner e de McNamara. Para isso, estudou-se uma amostra de vinte telerradiografias em norma lateral tomadas de pacientes sem problemas marcantes de simetria, e feitas em aparelhos radiográficos com especificações idênticas. Aplicou-se um tratamento de correção da ampliação da imagem radiográfica e outro para estimar as posições dos pontos médios de estruturas pares bilaterais e simétricas, e comparou-se esses valores com aqueles obtidos de forma convencional (sem correção dos erros de projeção). Nessas comparações utilizou-se teste t de "Student" para amostras correlatas. Observou-se que as grandezas cefalométricas angulares não sofreram influência da correção da ampliação da imagem; as grandezas lineares sofreram aumento na mesma proporção do grau de ampliação da imagem radiográfica; e os diferentes tratamentos dados a pontos bilaterais trouxeram resultados diferentes. Concluiu-se que a influência dos erros de projeção sobre as grandezas cefalométricas foi significante. / Abstract: Since Broadbent introduced cephalometric radiology method, in 1931, means are studied for minimizing its errors and effects. Projection errors are discussed since the first studies in cephalometry, but their consequences are not thoroughly understood. The object of this research work is to analyze projection errors effects on linear and angular measurements from Steiner and McNamara cephalograms. A sample of twenty lateral radiographs from patients with no symmetry problem was studied; each radiograph was taken on radiographic systems with identical specifications. Two treatments were analyzed: one for magnification correction and other to minimize distortion effects on symmetric anatomical structures. These treatments brought values that were compared to those obtained in a conventional way (with no correction for projection errors). These statistical comparisons were performed by Student's "t" test for paired samples. The following observations were found: angular measurements were not influenced by magnification correction; linear measurements were increased in the same proportion as the magnification factor for that radiographic system; and, results were influenced by the way bilateral points were handled. This research work conclusion was that changes from the correction of projection errors were significant. / Mestre
4

Modelagem matemática da fluidodinâmica não-newtoniana e bifásica simplificada da hemólise induzida mecanicamente em sistemas de bombeamento centrífugo de sangue / Simplified two-phase description for the non-Newtonian flow induced hemolysis in centrifugal blood systems

Morales, Marcelo Mecchi 08 November 2017 (has links)
A hemólise induzida mecanicamente em sistemas de bombeamento centrífugo é um processo complexo para o qual ainda se almeja um modelo matemático que possa auxiliar eficazmente o desenvolvimento e otimização destes dispositivos médicos. Este trabalho propõe um equacionamento matemático do escoamento do fluido sanguíneo no interior de bombas centrífugas, levando-se em consideração as variações do campo de tensões através de uma abordagem reológica não-newtoniana. A destruição da fase globular é modelada matematicamente por uma distribuição estatística. Tal modelo bifásico simplificado é utilizado em simulações numéricas de experimentos virtuais propostos e padronizados pela comunidade científica internacional especializada. A validação do modelo é realizada através de comparação com resultados referenciais. Os resultados obtidos demonstram um nova possibilidade de solução numérico-computacional para o problema da hemólise por trauma mecânico. / Mechanically induced hemolysis in centrifugal pumping systems is a complex process for which a mathematical model is still desired. It can effectively aid the development and optimization of these medical devices. This work proposes a mathematical modeling for the blood flow into centrifugal pumps, taking into account the variations of the stress field through a non-Newtonian rheological approach. The destruction of the globular phase is mathematically modeled by a statistical distribution. Such a simplified two-phase model is used in numerical simulations of virtual experiments proposed and standardized by the international scientific community. The validation of the model is performed through comparison with reference results. The results obtained show a new mathematical solution for the problem of hemolysis induced by mechanical trauma.
5

Modelagem matemática da fluidodinâmica não-newtoniana e bifásica simplificada da hemólise induzida mecanicamente em sistemas de bombeamento centrífugo de sangue / Simplified two-phase description for the non-Newtonian flow induced hemolysis in centrifugal blood systems

Marcelo Mecchi Morales 08 November 2017 (has links)
A hemólise induzida mecanicamente em sistemas de bombeamento centrífugo é um processo complexo para o qual ainda se almeja um modelo matemático que possa auxiliar eficazmente o desenvolvimento e otimização destes dispositivos médicos. Este trabalho propõe um equacionamento matemático do escoamento do fluido sanguíneo no interior de bombas centrífugas, levando-se em consideração as variações do campo de tensões através de uma abordagem reológica não-newtoniana. A destruição da fase globular é modelada matematicamente por uma distribuição estatística. Tal modelo bifásico simplificado é utilizado em simulações numéricas de experimentos virtuais propostos e padronizados pela comunidade científica internacional especializada. A validação do modelo é realizada através de comparação com resultados referenciais. Os resultados obtidos demonstram um nova possibilidade de solução numérico-computacional para o problema da hemólise por trauma mecânico. / Mechanically induced hemolysis in centrifugal pumping systems is a complex process for which a mathematical model is still desired. It can effectively aid the development and optimization of these medical devices. This work proposes a mathematical modeling for the blood flow into centrifugal pumps, taking into account the variations of the stress field through a non-Newtonian rheological approach. The destruction of the globular phase is mathematically modeled by a statistical distribution. Such a simplified two-phase model is used in numerical simulations of virtual experiments proposed and standardized by the international scientific community. The validation of the model is performed through comparison with reference results. The results obtained show a new mathematical solution for the problem of hemolysis induced by mechanical trauma.

Page generated in 0.1211 seconds