• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 67
  • 3
  • 1
  • Tagged with
  • 76
  • 29
  • 20
  • 19
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise experimental de erros de medição de energia elétrica ativa em medidores eletromagnéticos tipo indução, sujeitos a distorções harmônicas de correntes e tensões, em sistemas equilibrados e desequilibrados /

Velasco, Loana Nunes. January 2007 (has links)
Resumo: Considerando-se as constantes mudanças que vêm ocorrendo no cenário de distribuição de energia elétrica, devido ao grande avanço da eletrônica de potência e cargas não lineares instaladas no sistema, fazem-se necessários estudos para diagnosticar como e quanto essas mudanças podem estar afetando os equipamentos instalados nas redes de distribuição. A proposta deste trabalho é a análise da influência de harmônicos e desequilíbrios nos erros de medição de energia elétrica ativa em medidores de energia tipo indução, classe de precisão 2%. Estes equipamentos são normalmente projetados para atuarem com condições ideais de freqüência constante, formas de onda de tensão e corrente senoidais e sistema equilibrado. Condições estas, que não são a realidade das redes de distribuição de energia elétrica. Para a realização da análise dos equipamentos selecionados, submetidos aos efeitos das componentes harmônicas nas tensões e correntes, inclusive desequilíbrios de tensões, montou-se um arranjo padrão de medição, onde foram ensaiados os medidores submetidos à estes distúrbios, sob as mesmas condições laboratoriais, considerando-se três repetições para cada amostra selecionada. As distorções harmônicas de tensões e correntes, admitidas para ensaios, foram obtidas por medições em consumidores em... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Considering the constant changes that have been occurring in the electric energy distribution scenery, due to the great improvements of the power electronics devices and non linear loads installed in the system, there are several studies developed in order to analyze and diagnosis the effects of these changes, and how much these loads affect the equipments installed on the distribution systems. The proposal of this research is to analyze the influence of harmonic contents and voltage unbalances in the systems on the measurement errors of the active electric energy using the induction watt-hour meters, with accuracy of 2%. These equipments are usually designed to operate in ideal conditions with constant frequency, sinusoidal voltage and current waveforms, and balanced system. However, these conditions are not the reality of the electric energy distribution systems. The procedures for the measurements, considering the selected samples of the induction watt-hour meters under influence of current and voltage harmonic contents, and voltage unbalances, were based on a measurement set-up established for testing, in the same conditions, all the selected samples considering its three repetitions. The harmonic voltage and current contents, admitted for testing, were obtained by measurements in consumers with different load... (Complete abstract click electronic access below) / Orientador: Carlos Alberto Canesin / Coorientador: Flávio Alessandro Serrão Gonçalves / Banca: Luis Carlos Origa de Oliveira / Banca: Fernando Luiz Marcelo Antunes / Mestre
2

ESTIMATIVA do Fator de Perfil k na Medição Ultrassônica Por Tempo de Trânsito em Escoamentos Assimétricos Utilizando a Técnica de Problemas Inversos Acoplada a Simulação Numérica

STANGE, R. 20 March 2017 (has links)
Made available in DSpace on 2018-08-02T00:02:59Z (GMT). No. of bitstreams: 1 tese_11316_RAFAEL STANGE.pdf: 18863643 bytes, checksum: 7eec06a241d800e3340182b1e220712c (MD5) Previous issue date: 2017-03-20 / A medic¸ao de vazao ´e uma importante opera¸cao no escopo das aplica¸coes industriais, sendo regulamentado por diversos ´orgaos reguladores. Para satisfazer tais exigencias, a tecnologia por medi¸cao ultrassonica tem passado por grande evolu¸cao nos u´ltimos anos, muito em func¸ao de sua caracter´ıstica de baixa perda de carga associada, devido `a sua configura¸cao. Contudo, acidentes de linha causam interferencia em suas leituras, devido a altera¸coes no perfil de velocidades do escoamento. Novas pesquisas e modelos sao apresentados de forma a entender e considerar tais perturba¸coes, e adaptar as condi¸coes das instala¸coes industriais. De modo a agregar novos esfor¸cos, o presente trabalho apresenta uma aproxima¸cao do fator de perfil k atrav´es de t´ecnicas de problemas inversos. Essa abordagem busca quantificar as altera¸coes no perfil de velocidade e considerar tais efeitos no fator k. Neste trabalho foram abordadas simulac¸oes de escoamentos com Nu´mero de Reynolds entre 1⇥104 a2⇥106 sob influencia de curvas. Aproxima¸coes foram feitas com simula¸coes a 10D, 20D e 80D a` jusante da curva. Os resultados encontrados mostram-se promissores, sendo que, as diferen¸cas entre as simulac¸oes obtidas atrav´es da presente proposta para o fator k e os valores de vazao de referencia, ficaram abaixo de 2% na maioria dos casos simulados. Palavras-chave: Medidor de vazao ultrassonico, canal acu´stico, escoamentos turbulentos, problema inverso, Levemberg-Marquardt.
3

Medidor inteligente de la energía eléctrica mediante el sistema de infraestructura de medición avanzada (AMI)

Quispe López, César 14 May 2016 (has links)
La presente investigación resolvió la siguiente interrogante ¿Cómo influye el sistema AMI en el medidor inteligente de la energía eléctrica desarrollado en un módulo de prueba en la I.E.E Politecnico Regional del Centro del Tambo?, siendo el objetivo general: Determinar la influencia del sistema AMI en el medidor inteligente de la energía eléctrica desarrollado en un módulo de prueba en la I.E.E Politecnico Regional del Centro del Tambo. Planteándose como hipótesis: El sistema AMI influye positivamente en el medidor inteligente de la energía eléctrica desarrollado en un módulo de prueba en la I.E.E Politécnico Regional del Centro. El estudio se desarrolló desde la perspectiva de una investigación tecnológica con un diseño cuasi experimental, utilizó una muestra de 40 estudiantes divididos en dos secciones “G” y “F” quienes manipularon el medidor con el sistema AMI y sin el sistema AMI, fue seleccionado mediante muestreo no estratificado, se recopiló los datos a través de mediciones por parte de los dos medidores, cuyos resultados se analizaron con la estadística descriptiva y correlacional según el consumo por kWh , costo por kWh y tipo de medidor utilizado . En conclusión se halló una influencia positiva directa entre el sistema AMI y medidor inteligente de la energía eléctrica realizado en un módulo de prueba en la I.E.E Politécnico Regional del centro con un 95% de confianza que refleja que en medidores que incluyan un sistema (AMI) el consumo en Kwh es menor dando como consecuencia menor costo y que el diseño del equipo está en promedio de los otros medidores que se expenden en el mercado. / Tesis
4

Análise Experimental da Sensibilidade da Tecnologia Ultrassônica para Medição de Gás de Queima Sob o Efeito de Curva

LIMA, E. S. M. 16 October 2013 (has links)
Made available in DSpace on 2016-08-29T15:33:03Z (GMT). No. of bitstreams: 1 tese_6920_ERIC SIMÃO MARTINS LIMA.pdf: 1134155 bytes, checksum: 13c24c3e34bc4d1bcf89e0bb7b001051 (MD5) Previous issue date: 2013-10-16 / A indústria de petróleo e gás requer medições de vazão com baixa incerteza, uma vez que são estabelecidas por lei. Contudo, curvas e outros obstáculos são comumente encontrados nesse cenário, o que pode afetar a qualidade da medição de vazão em função de perturbações no escoamento, tais como swirl e assimetrias no perfil de velocidades. Em sistemas de gás de tocha, que são comumente utilizados como sistemas de segurança e alivio em ativos produtores de hidrocarbonetos, a sua quantificação tem sido considerada por especialistas como uma condição de medição das mais desafiadoras, tendo em vista que esses escoamentos apresentam tipicamente características tais como, instalações em grandesdiâmetros, necessidade de baixos índices de manutenção, necessidade de baixa intrusividade ao processo, variações na composição química do gás, presença eventual de líquidos (condensado ou gotículas de óleo), que contribuem para que a adequação dessa medição aos requisitos da legislação seja um problema tecnológico de elevada relevância. Medidores de vazão por ultrassom de um canal acústico são frequentemente utilizados em instalações de queima de gás de tocha, apesar de serem sensíveis a tais perturbações promovidas pela presença de acidentes de instalação. À vista disso, este trabalho visa à análise experimental do efeito de curvas na medição de Gás de tocha. Sob esse aspecto, o objetivo deste trabalho é analisar experimentalmente o comportamento das leituras de um medidor ultrassônico (UFM) sob efeito de curvas em um túnel de vento atmosférico com medição de referência por tubo de Pitot. Os resultados obtidos demonstram que as leituras do UFM sofrem influência dos efeitos de curvas quando o trecho de medição é variado. Palavras chave: Medidor ultrassônico de vazão, Pitot, gás de queima
5

Efeitos das distorções harmônicas (tensões e correntes) e desequilíbrios (tensões) em medidores eletrônicos trifásicos de energia elétrica ativa /

Silva, Luiz Carlos Evangelista da. January 2008 (has links)
Orientador: Carlos Alberto Canesin / Coorientador: José Carlos Rossi / Banca: Flávio Alessandro Serrão Gonçalves / Banca: João Onofre Pereira Pinto / Resumo: Considerando-se as constantes mudanças que vêm ocorrendo no cenário de distribuição de energia elétrica, devido ao grande avanço da eletrônica de potência e cargas não lineares instaladas no sistema elétrico, fazem-se necessários estudos para diagnosticar como e quanto essas alterações interferem nos equipamentos instalados nas redes de distribuição. A proposta desta dissertação é a análise da influência das distorções harmônicas (tensões e correntes) e desequilíbrios (tensões) nos erros de medição de energia elétrica ativa em medidores eletrônicos trifásicos. Estes equipamentos são normalmente projetados para atuarem com condições ideais de freqüência constante, formas de onda de tensão e corrente senoidais e em sistemas equilibrados. Condições estas, que não refletem a realidade das redes de distribuição de energia elétrica. Para a realização da análise dos equipamentos selecionados, submetidos aos efeitos das componentes harmônicas nas tensões e correntes, inclusive desequilíbrios de tensões, montou-se um arranjo padrão de medição, onde foram ensaiados os medidores submetidos a estes distúrbios, sob as mesmas condições laboratoriais, considerando-se três repetições para cada amostra selecionada. As distorções harmônicas de tensões e correntes, aplicadas nos ensaios, foram obtidas por medições em consumidores em ramais de distribuição com características industrial, comercial, rural e residencial, e, os desequilíbrios de tensões admitidos para ensaios foram de 3% (limite atual) e de 5%, considerando-se determinados cenários de um sistema de distribuição real de uma concessionária de energia elétrica. Os resultados são apresentados em forma de tabelas e figuras, e, as análises dos erros são apresentadas considerando-se um padrão de medição composto por analisador de energia com classe de exatidão... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Considering the constant changes that have been occurring in the electric energy distribution scenery, due to the great improvements of the power electronics devices and non linear loads installed in the system, there are several studies developed in order to analyze and diagnosis the effects of these changes, and how much these loads affect the equipments installed on the distribution systems. The proposal of this research is to analyze the influence the harmonic contents (voltage and current) and unbalances (voltage) in the systems on the measurement errors of the active electric energy using three-phase electronic meters. These equipments are usually designed to operate on ideal conditions with constant frequency, sinusoidal voltage and current waveforms, and balanced system. However, these conditions are not the reality of the electric energy distribution systems. The procedures for the measurements, considering the selected samples of the electronics meters under influence of current and voltage harmonic contents, and voltage unbalances, were based on a measurement set-up established for testing, in the same conditions, all the selected samples considering its three repetitions. The harmonic voltage and current contents, applied in the tests, were obtained by measurements in consumers with different load characteristics (industrial, commercial, rural and residential), and the admitted voltage unbalances were of 3% (actual limit imposed by standards) and 5%, considering real cases of an electric energy distribution system of an utilities. The results are summarized in tables and figures, and the analyses of the errors are presented considering comparisons with a standard of measurement composed by an energy analyzer, with accuracy of 0.1% for voltages and currents, and, 0.2% for active power, considering the range of 60Hz until 1kHz. In addition, models were developed... (Complete abstract click electronic access below) / Mestre
6

Análise experimental de erros de medição de energia elétrica ativa em medidores eletromagnéticos tipo indução, sujeitos a distorções harmônicas de correntes e tensões, em sistemas equilibrados e desequilibrados

Velasco, Loana Nunes [UNESP] 30 April 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:36Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-04-30Bitstream added on 2014-06-13T19:08:16Z : No. of bitstreams: 1 velasco_ln_me_ilha.pdf: 5900543 bytes, checksum: 615cdafd17dd2d779ee50088aa3f060a (MD5) / Fundação de Ensino Pesquisa e Extensão de Ilha Solteira (FEPISA) / Considerando-se as constantes mudanças que vêm ocorrendo no cenário de distribuição de energia elétrica, devido ao grande avanço da eletrônica de potência e cargas não lineares instaladas no sistema, fazem-se necessários estudos para diagnosticar como e quanto essas mudanças podem estar afetando os equipamentos instalados nas redes de distribuição. A proposta deste trabalho é a análise da influência de harmônicos e desequilíbrios nos erros de medição de energia elétrica ativa em medidores de energia tipo indução, classe de precisão 2%. Estes equipamentos são normalmente projetados para atuarem com condições ideais de freqüência constante, formas de onda de tensão e corrente senoidais e sistema equilibrado. Condições estas, que não são a realidade das redes de distribuição de energia elétrica. Para a realização da análise dos equipamentos selecionados, submetidos aos efeitos das componentes harmônicas nas tensões e correntes, inclusive desequilíbrios de tensões, montou-se um arranjo padrão de medição, onde foram ensaiados os medidores submetidos à estes distúrbios, sob as mesmas condições laboratoriais, considerando-se três repetições para cada amostra selecionada. As distorções harmônicas de tensões e correntes, admitidas para ensaios, foram obtidas por medições em consumidores em... / Considering the constant changes that have been occurring in the electric energy distribution scenery, due to the great improvements of the power electronics devices and non linear loads installed in the system, there are several studies developed in order to analyze and diagnosis the effects of these changes, and how much these loads affect the equipments installed on the distribution systems. The proposal of this research is to analyze the influence of harmonic contents and voltage unbalances in the systems on the measurement errors of the active electric energy using the induction watt-hour meters, with accuracy of 2%. These equipments are usually designed to operate in ideal conditions with constant frequency, sinusoidal voltage and current waveforms, and balanced system. However, these conditions are not the reality of the electric energy distribution systems. The procedures for the measurements, considering the selected samples of the induction watt-hour meters under influence of current and voltage harmonic contents, and voltage unbalances, were based on a measurement set-up established for testing, in the same conditions, all the selected samples considering its three repetitions. The harmonic voltage and current contents, admitted for testing, were obtained by measurements in consumers with different load... (Complete abstract click electronic access below)
7

Avaliação Experimental do Desempenho de Protótipo de Medidor de Vazão para Óleos Pesados Por Tecnologia Ultrassônica Por Tempo de Trânsito

ABOUJAOUDE, F. 18 December 2017 (has links)
Made available in DSpace on 2018-03-22T15:51:24Z (GMT). No. of bitstreams: 1 tese_11637_FADY ABOUJAOUDE .pdf: 42298478 bytes, checksum: fa8b54eaf1878ccba2132f35dfd67c06 (MD5) Previous issue date: 2017-12-18 / A medição ultrassônica por tempo de trânsito vem sendo utilizado cada vez mais nos últimos anos, havendo, sem dúvida, a necessidade urgente de desenvolvimento de tecnologia brasileira neste campo da instrumentação. Este trabalho se dedica ao estudo de medição de vazão em óleos pesados por ultrassom com a pretensão de verificar experimentalmente a validade dos processos estatísticos utilizados visando a redução das incertezas nas leituras. Para isso o trabalho analisa experimentalmente efeitos de possíveis erros do medidor por tempo de trânsito validando-os em relação a um medidor de vazão de referência. Medidor Ultrassônico, tempo de trânsito, óleo pesado, medição de vazão
8

Sistema dosimétrico microcontrolado, baseado em detectores semicondutores, para análise de desempenho de equipamentos mamográficos

Vieira Batista, Eutrópio January 2006 (has links)
Made available in DSpace on 2014-06-12T23:15:43Z (GMT). No. of bitstreams: 2 arquivo9090_1.pdf: 1402063 bytes, checksum: a196fc79749f442b321d45f38cc0cca0 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2006 / Um dos parâmetros mais importantes para a implementação de programas de controle de qualidade em radiodiagnóstico é o desempenho do equipamento. Este trabalho apresenta as características de um instrumento projetado e construído para a avaliação do equipamento de raios-X mamográfico pelo método não invasivo. O instrumento é capaz de medir simultaneamente o tempo de irradiação, o kerma no ar incidente na pele e o valor da tensão aplicada ao tubo de raios-X. Ele consiste de um conjunto de três sensores semicondutores conectados no modo fotovoltaico à entrada de eletrômetros integradores especialmente construídos. Um desses detectores é fixado sob filtros de cobre e alumínio e os outros dois são fixados sem filtros. Um deles é usado somente para o controle do processo de medição e para ativar um temporizador eletrônico para medir o tempo de irradiação. O sinal do semicondutor sem filtro é usado para avaliar o kerma no ar incidente na pele. A razão entre as leituras desse detector e daquele coberto com os filtros fornece dados para a determinação da tensão do tubo. O instrumento denominado MAMO-KVDT-01 foi testado com um equipamento de raios-X mamográfico. Os resultados mostraram uma resposta linear do instrumento com dose de radiação no intervalo de 5,0 a 14,0 mGy, com um coeficiente de determinação de 0,9961. O teste de estabilidade da sua resposta para a medida de tensão também mostrou uma boa reprodutibilidade dentro de ±1,5%. Esses resultados qualificam o MAMO-KVDT-01 como instrumento adequado para o controle de qualidade de equipamentos mamográficos
9

Medidor de vazão de água, tipo \"Pitot-Cole\", com configuração prismática hexagonal. / Water flow meter, as \"Pilot-Cole\", with hexagonal prismatic configuration.

Siqueira, Natally Annunciato 22 June 2018 (has links)
A medição de vazão é fundamental para a gestão de processos que envolvem fluidos. Em empresas de saneamento, contabilizar as entradas e saídas de água é essencial para gerir faturamentos e perdas. A vazão pode ser mensurada através de diversos instrumentos com diferentes princípios de aplicação. O Tubo Pitot Cole é capaz de determinar a vazão em tubulações através do diferencial de pressão. Trata-se se um equipamento inventado em 1732 por Henri Pitot para determinar a velocidade, e aperfeiçoado por Eduard Cole, em 1896, permitindo sua aplicação em tubulações. As principais vantagens são o baixo custo e fácil instalação, que pode ocorrer com a tubulação em carga. Em contrapartida, a fragilidade e complexidade das suas peças motivaram este trabalho: a elaboração de um instrumento simples e robusto para medir a vazão. Propõe-se a construção de um protótipo com tomadas de pressão instaladas em faces opostas de um prisma hexagonal e a avalia-se a sua viabilidade na medição de vazão. Os resultados mostraram-se promissores dada a estabilidade e forte correlação linear obtida no coeficiente de calibração. / Flow measurements are essential for processes management that include fluids. In water companies, measuring inlets and outlets of water is essential to manage revenue and water losses. The water flow can be measured through different instruments with different application principles. The Pitot Cole Tube is able to determine flow in pipes through the pressure differential. This device was invented in 1732 by Henri Pitot to determine fluid velocity and it was improved by Eduard Cole in 1896, allowing to apply the instrument in pipes. The main advantages are the low cost and easy installation, that may occur with the pipe under load. However, the fragility and complexity of its pieces motivated this study: the construction of a simple and robust instrument to measure the water flow. It is proposed the construction of a prototype with pressure plugs installed on opposite faces of a hexagonal prism, then evaluation of its effectiveness in water flow measurements. The results were promising given the stability obtained in the calibration coefficient.
10

Medidor de vazão de água, tipo \"Pitot-Cole\", com configuração prismática hexagonal. / Water flow meter, as \"Pilot-Cole\", with hexagonal prismatic configuration.

Natally Annunciato Siqueira 22 June 2018 (has links)
A medição de vazão é fundamental para a gestão de processos que envolvem fluidos. Em empresas de saneamento, contabilizar as entradas e saídas de água é essencial para gerir faturamentos e perdas. A vazão pode ser mensurada através de diversos instrumentos com diferentes princípios de aplicação. O Tubo Pitot Cole é capaz de determinar a vazão em tubulações através do diferencial de pressão. Trata-se se um equipamento inventado em 1732 por Henri Pitot para determinar a velocidade, e aperfeiçoado por Eduard Cole, em 1896, permitindo sua aplicação em tubulações. As principais vantagens são o baixo custo e fácil instalação, que pode ocorrer com a tubulação em carga. Em contrapartida, a fragilidade e complexidade das suas peças motivaram este trabalho: a elaboração de um instrumento simples e robusto para medir a vazão. Propõe-se a construção de um protótipo com tomadas de pressão instaladas em faces opostas de um prisma hexagonal e a avalia-se a sua viabilidade na medição de vazão. Os resultados mostraram-se promissores dada a estabilidade e forte correlação linear obtida no coeficiente de calibração. / Flow measurements are essential for processes management that include fluids. In water companies, measuring inlets and outlets of water is essential to manage revenue and water losses. The water flow can be measured through different instruments with different application principles. The Pitot Cole Tube is able to determine flow in pipes through the pressure differential. This device was invented in 1732 by Henri Pitot to determine fluid velocity and it was improved by Eduard Cole in 1896, allowing to apply the instrument in pipes. The main advantages are the low cost and easy installation, that may occur with the pipe under load. However, the fragility and complexity of its pieces motivated this study: the construction of a simple and robust instrument to measure the water flow. It is proposed the construction of a prototype with pressure plugs installed on opposite faces of a hexagonal prism, then evaluation of its effectiveness in water flow measurements. The results were promising given the stability obtained in the calibration coefficient.

Page generated in 0.0461 seconds