• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Επίδραση κατανεμημένων παραγωγών στη λειτουργία συστήματος ηλεκτρικής ενέργειας

Παπανικολάου, Κωνσταντίνα 03 April 2015 (has links)
Στην παρούσα διπλωματική εργασία πραγματοποιείται μελέτη της επίδρασης ενός συστήματος διασύνδεσης ανεμογεννήτριας με το δίκτυο μέσης τάσης, όσον αφορά την έγχυση αρμονικών από την ανεμογεννήτρια προς το δίκτυο. Η μελέτη περιλαμβάνει τη μοντελοποίηση κάθε τμήματος ενός δικτύου μέσης τάσης με πραγματικά στοιχεία που πάρθηκαν από τη ΔΕΗ. Επιπλέον, μοντελοποιείται μια ανεμογεννήτρια τύπου σύγχρονης μόνιμων μαγνητών, καθώς και όλοι οι ηλεκτρονικοί μετατροπείς ισχύος που απαιτούνται για τη διασύνδεση αυτής με το δίκτυο μέσης τάσης. Όλα τα επιμέρους μοντέλα διασυνδέονται μεταξύ τους ώστε να αποτελέσουν το συνολικό μοντέλο που περιλαμβάνει το δίκτυο μέσης τάσης με τις γραμμές μεταφοράς, τους μετασχηματιστές, τα φορτία και τους πυκνωτές αντιστάθμισης που διαθέτει και την ανεμογεννήτρια μαζί με τους μετατροπείς συνδεδεμένη σε ένα ζυγό του δικτύου. Από το μοντέλο αυτό εξάγεται το αρμονικό περιεχόμενο τόσο στο ζυγό της ανεμογεννήτριας όσο και σε διπλανούς ζυγούς και συγκρίνεται κάθε φορά με το πρότυπο IEC 61000-3-6 που θέτει τα όρια για την έγχυση αρμονικών στο δίκτυο μέσης τάσης. Αρχικά, γίνεται μια αναφορά στα πλεονεκτήματα της αιολικής ενέργειας έναντι των άλλων συμβατικών μορφών ενέργειας. Επιπλέον, αναφέρονται τα προβλήματα που δημιουργούνται από την παρουσία ανώτερων αρμονικών στο δίκτυο. Έπειτα, πραγματοποιείται θεωρητική ανάλυση κάθε τμήματος του δικτύου μέσης τάσης. Για κάθε τμήμα δημιουργείται, επίσης, ένα μοντέλο στο Matlab/Simulink που βασίζεται σε στοιχεία από τη ΔΕΗ και εξισώσεις που αφορούν το εκάστοτε τμήμα. Στη συνέχεια, αναλύεται και μοντελοποιείται στο Matlab/Simulink και κάθε τμήμα του συστήματος διασύνδεσης της ανεμογεννήτριας με το δίκτυο μέσης τάσης που περιλαμβάνει την ανεμογεννήτρια τύπου σύγχρονης μόνιμων μαγνητών, ανορθωτική διάταξη, μετατροπέα συνεχούς τάσης σε συνεχή, τριφασικό αντιστροφέα, φίλτρο και μετασχηματιστή. Για κάθε μετατροπέα αναλύεται και μοντελοποιείται και έλεγχος κλειστού βρόχου. Τέλος, τα επιμέρους μοντέλα συγκροτούνται σε ένα συνολικό μοντέλο. Μεταβάλλοντας το συντελεστή φόρτισης των μετασχηματιστών του δικτύου, το συντελεστή ισχύος και το πλήθος των ανεμογεννητριών που συνδέονται στον ίδιο ζυγό, εξάγεται το αρμονικό περιεχόμενο για διάφορους ζυγούς και ελέγχεται αν αυτό συμφωνεί με το πρότυπο IEC 61000-3-6. Επιπλέον, εξετάζεται το αρμονικό περιεχόμενο της τάσης, όταν ο ζυγός διασύνδεσης αλλάζει θέση μέσα στο υπό μελέτη δίκτυο, καθώς και όταν αλλάζει η ταχύτητα του ανέμου. / In the present diploma thesis a study of the effect of a wind turbine system interconnection with medium voltage grid is conducted, in terms of harmonic injection of the turbine to the grid. The study includes the modeling of each part of a medium voltage grid with actual data taken from the Public Power Corporation of Greece. Furthermore, a synchronous wind turbine with permanent magnets is modeled along with all the electronic power converters that are required for the interconnection with the medium voltage grid. All the individual models are connected together to form the overall model, including the medium voltage transmission lines, transformers, loads and their compensation capacitors, along with the wind turbine and the power converters. The wind turbine is connected in a bus of the medium voltage grid. Then, the harmonic content in both the bus of the wind turbine and in other buses of the grid is extracted and compared with the standard IEC 61000-3-6 that sets the limits for harmonic injection in medium voltage grid. Initially, the advantages of use of wind energy are mentioned compared to other conventional forms of energy. Furthermore, the problems caused by the presence of harmonics in the grid are discussed. A theoretical analysis of each section of the medium voltage grid is conducted. For each section, a model in Matlab / Simulink is also created, based on data from the Public Power Corporation of Greece and on equations related to each section. Then, every part of the system connecting the wind turbine to the medium voltage grid is analyzed and modeled in Matlab/Simulink. This system consists of a synchronous wind turbine with permanent magnets, DC-to-DC converter, three-phase inverter, filter and transformer. A closed loop control for each converter is also analyzed and modeled. Finally, the aforementioned models are built up into one single model. By varying the load factor of the grid transformers, the power factor and the number of wind turbines connected to the same bus, the harmonic content of various buses is extracted and checked if it complies with the standard IEC 61000-3-6. Moreover, the harmonic content of the voltage is calculated, when the system of wind turbine changes position in the present medium voltage grid, as well as when the wind speed is changed.
2

Kabeldiagnostik i mellanspänningsnät

Våglöf, Patrik January 2018 (has links)
Sundsvall elnät har länge jobbat med att vädersäkra sitt elnät genom att gräva ner sitt mellanspänningsnät och det finns i dagsläget inga riktlinjer för hur mellanspänningskablar skall inspekteras. Målet med denna rapport var att utveckla en metod för hur Sundsvall elnät skulle kunna bedöma skicket på sina mellanspänningskablar, utreda vilka referensvärden borde användas, samt utforma rekommendationer för hur mätningarna borde tolkas i förhållande till möjligheten att fortsätta att ha kablarna i drift. För att möta målen genomfördes en litteraturstudie där olika diagnostikmetoder undersöks, referensvärden togs fram. Kablarnas åldringsmekanismer undersöktes samt konsekvenser av dåliga kablar förklaras. Utöver detta så utfördes ett antal mätningar i fält med tillgängliga mätmetoder. Rapporten visar på att det finns många tillgängliga mätmetoder för kabeldiagnostik men att få metoder har erkända referensvärden för bedömning. Rapporten påvisar att en kombination av mätningar med tangens med VLF, mätning av partiella urladdningar samt resistansmätning av kabelskärm/följeledare kan vara en bra metod bedöma skicket på mellanspänningskablar. / Sundsvall elnät has been working to weatherproof their grid by placing their medium voltage grid underground and to this date there are no regulations with regards to how to inspect underground cables. The aim of this survey was to develop a method for Sundsvall elnät on how to assess the condition of their medium voltage cables, investigate which reference values should be used, and to formulate recommendations on how measurements should be interpreted with regards to how long the cable can remain in service. To meet the aim of the survey a literature study was conducted where different methods for cable diagnostics, reference values, ageing mechanisms for medium voltage cables and consequences of bad cables was investigated. Furthermore some measurements are performed in field environment with available equipment. The report shows that there are many available methods for diagnostics of medium voltage cables but few methods that have recognized reference values. The report also shows that a combination of measurements containing tangens  with VLF, measurement of partial discharges and a resistance measurement of the cable screen and ground line could be a useful method for assessing the condition of medium voltage cables.

Page generated in 0.0655 seconds