• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • Tagged with
  • 31
  • 31
  • 26
  • 17
  • 17
  • 15
  • 12
  • 9
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Utilização da técnica de espectrometria de fluorescência de raios X para determinação de resíduos catalíticos em polímeros comerciais

Bichinho, Katia Messias January 2008 (has links)
A quantificação de teores de resíduos catalíticos em resinas produzidas pela indústria petroquímica constitui-se em etapa importante para controlar a qualidade do produto. Embora teoricamente ofereça condições interessantes, ressaltando a possibilidade de análise direta de matrizes poliméricas em corpos de prova com espessuras e tamanhos variados, procedimentos simplificados para a preparação das amostras, tempo e custo operacional baixos para a quantificação, uma rápida busca na literatura aponta que a técnica de XRF é pouco utilizada para esse fim. No presente trabalho, estudos foram desenvolvidos para avaliar a adequação da técnica de XRF para a quantificação de teores residuais de metais em polímeros comerciais. Para tanto, polietilenos produzidos por catalisadores Ziegler-Natta, Philips e metalocenos foram analisados por XRF. Padrões sintéticos a partir de cera comercial foram confeccionados visando à determinação quantitativa de resíduos metálicos e foram comparados àqueles preparados através de mistura de polietileno isento de metais, empregado como matriz, com óxido metálico pulverizado, seguido pelo processamento de moagem, para homogeneização adequada. A homogeneidade de distribuição dos metais nos padrões sintéticos foi avaliada estatisticamente e considerada adequada para aplicação em determinações quantitativas. Disponível comercialmente, o material de referência certificado ERM - EC680 (IRMM) foi utilizado nos estudos. Os limites de detecção obtidos para os metais estudados nas diferentes amostras de polietilenos por WDXRF foram: 12 mg kg-1 para Mg, 0,8 mg kg-1 para Ti, 1,6 mg kg-1 para Cr, 1,2 mg kg-1 para Zr e 1,9 mg kg-1 para V. Por SR - TXRF, o limite de detecção obtido para V foi igual a 1,4 µg L-1. Por razões comparativas, a determinação de resíduos metálicos foi avaliada também por RBS. / Commercial polyethylenes produced by Ziegler-Natta, Philips and metallocene technology were analyzed by X-ray fluorescence spectroscopy. Synthetic standards using wax matrix was shown to be suitable for the calibration curve in comparison to those prepared by milling and grinding virgin polymer mixed with standard metal oxide as matrix. The detection limits obtained for the studied metal in different polymers by WDXRF were: 12 mg kg-1 for Mg, 0.8 mg kg-1 for Ti, 1.6 mg kg-1 for Cr, 1.2 mg kg-1 for Zr and 1.9 mg kg-1 for V. By SR - TXRF, the detection limit obtained for V was 1,4 µg L-1. For comparative reasons, the determination of residual metal content by Rutherford backscattering spectrometry (RBS) and total-reflection X-ray fluorescence spectrometry (TXRF) is also discussed.
2

Determinação espectrofotométrica de cromo(VI) na presença de cromo(III) usando Br-PADAP

Rocha, Sérgio Anunciação January 2000 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-09-30T14:20:32Z No. of bitstreams: 3 Rocha, Sérgio Anunciação.pdf: 189596 bytes, checksum: 4b0caf2405235f9ebce32b24034c6cf9 (MD5) Rocha, Sérgio Anunciação 1.pdf: 347820 bytes, checksum: 62a704a656fac6e71c3d1d08cfc8c577 (MD5) Tabela de resultados corrigida.pdf: 20946 bytes, checksum: 7b7af125e0636429338049c0b0eca2da (MD5) / Approved for entry into archive by NUBIA OLIVEIRA (nubia.marilia@ufba.br) on 2016-10-10T14:04:25Z (GMT) No. of bitstreams: 3 Rocha, Sérgio Anunciação.pdf: 189596 bytes, checksum: 4b0caf2405235f9ebce32b24034c6cf9 (MD5) Rocha, Sérgio Anunciação 1.pdf: 347820 bytes, checksum: 62a704a656fac6e71c3d1d08cfc8c577 (MD5) Tabela de resultados corrigida.pdf: 20946 bytes, checksum: 7b7af125e0636429338049c0b0eca2da (MD5) / Made available in DSpace on 2016-10-10T14:04:25Z (GMT). No. of bitstreams: 3 Rocha, Sérgio Anunciação.pdf: 189596 bytes, checksum: 4b0caf2405235f9ebce32b24034c6cf9 (MD5) Rocha, Sérgio Anunciação 1.pdf: 347820 bytes, checksum: 62a704a656fac6e71c3d1d08cfc8c577 (MD5) Tabela de resultados corrigida.pdf: 20946 bytes, checksum: 7b7af125e0636429338049c0b0eca2da (MD5) / CNPQ / A especiação de cromo é muito importante porque o cromo(VI) é conhecido por ser tóxico para seres humanos, enquanto que o cromo(III) é essencial a nível de traços para manutenção da taxa normal de glicose em animais inclusive o homem. No presente trabalho, é proposto um método indireto para a determinação de cromo(VI) na presença de cromo(III). O método é baseado na reação de redução do cromo(VI) por ferro(II) e reação de complexação do ferro(II) que não reagiu com o reagente 2-(5-bromo-2-piridilazo)-5-dietilaminofenol (Br-PADAP). O ferro(II) reage com Br-PADAP, formando um complexo estável que absorve a 560 e 748 nm. Os seguintes parâmetros foram estudados: efeito do volume da solução de referência na reação de oxidação, efeito de pH na reação de oxidação, quantidade de ferro(II), efeito de pH na reação de complexação, quantidade de Br-PADAP, quantidade de EDTA, sensibilidade de calibração, sensibilidade analítica, efeito de outros íons e precisão. Os resultados demonstraram que cromo(VI) pode ser determinado na presença de cromo(III), com absortividade molar aparente de 7,3 x 104 l. mol-1. cm-1 a 748 nm. O uso de EDTA permite um procedimento com boa seletividade. Os resultados revelaram que 275,0 g de cromo(III) não interfere durante a determinação de 5,0 g de cromo(VI). Uma boa precisão (R.S.D.  2%) foi obtida. Este método foi usado para determinação de cromo(VI) em amostras de água coletadas no efluente do rio Catu na cidade de Pojuca, na Bahia. / The speciation of chromium is very important because the chromium(VI) is known to be toxic to humans, while that the chromium(III) is essential at trace levels to maintain normal glucose to animals and man. In the present work a indirect method for chromium(VI) determination in the presence of chromium(III) is proposed. It is based on the oxidation reaction of iron(II) by chromium(VI) and complexation reaction of unreacted iron(II) with the spectrophotometric reagent 2-(5-bromo-2-piridilazo)-5-dietilaminofenol (Br-PADAP). The iron(II) reacts with Br-PADAP, forming a stable complex which absorbs at 560 and 748 nm. The sequentes parameters were studied: effect of reference solution volume on the oxidation reaction, effect of pH of reference solution on the oxidation reaction, amount of iron(II), effect of pH on the complexation reaction, amount of Br-PADAP, amount of EDTA, calibration sensitivity, analytical sensitivity, effect of other ions and precision. The results demonstrated that chromium(VI) can be determinated in the presence of chromium(III), with apparent molar absorptivity of 7,3 . 104 l. mol-1. cm-1 at 748 nm. The use of EDTA as masking agent allowed a procedure with great selectivity. The results revealed that 275.0g of chromium(III) do not interfere during the determination of 5.0 g of chromium(VI). A good precision (R.S.D.  2%) was obtained. This method was used for chromium(VI) determination in water samples in the effluent of the Catu river, in the Pojuca city, Bahia.
3

Utilização da técnica de espectrometria de fluorescência de raios X para determinação de resíduos catalíticos em polímeros comerciais

Bichinho, Katia Messias January 2008 (has links)
A quantificação de teores de resíduos catalíticos em resinas produzidas pela indústria petroquímica constitui-se em etapa importante para controlar a qualidade do produto. Embora teoricamente ofereça condições interessantes, ressaltando a possibilidade de análise direta de matrizes poliméricas em corpos de prova com espessuras e tamanhos variados, procedimentos simplificados para a preparação das amostras, tempo e custo operacional baixos para a quantificação, uma rápida busca na literatura aponta que a técnica de XRF é pouco utilizada para esse fim. No presente trabalho, estudos foram desenvolvidos para avaliar a adequação da técnica de XRF para a quantificação de teores residuais de metais em polímeros comerciais. Para tanto, polietilenos produzidos por catalisadores Ziegler-Natta, Philips e metalocenos foram analisados por XRF. Padrões sintéticos a partir de cera comercial foram confeccionados visando à determinação quantitativa de resíduos metálicos e foram comparados àqueles preparados através de mistura de polietileno isento de metais, empregado como matriz, com óxido metálico pulverizado, seguido pelo processamento de moagem, para homogeneização adequada. A homogeneidade de distribuição dos metais nos padrões sintéticos foi avaliada estatisticamente e considerada adequada para aplicação em determinações quantitativas. Disponível comercialmente, o material de referência certificado ERM - EC680 (IRMM) foi utilizado nos estudos. Os limites de detecção obtidos para os metais estudados nas diferentes amostras de polietilenos por WDXRF foram: 12 mg kg-1 para Mg, 0,8 mg kg-1 para Ti, 1,6 mg kg-1 para Cr, 1,2 mg kg-1 para Zr e 1,9 mg kg-1 para V. Por SR - TXRF, o limite de detecção obtido para V foi igual a 1,4 µg L-1. Por razões comparativas, a determinação de resíduos metálicos foi avaliada também por RBS. / Commercial polyethylenes produced by Ziegler-Natta, Philips and metallocene technology were analyzed by X-ray fluorescence spectroscopy. Synthetic standards using wax matrix was shown to be suitable for the calibration curve in comparison to those prepared by milling and grinding virgin polymer mixed with standard metal oxide as matrix. The detection limits obtained for the studied metal in different polymers by WDXRF were: 12 mg kg-1 for Mg, 0.8 mg kg-1 for Ti, 1.6 mg kg-1 for Cr, 1.2 mg kg-1 for Zr and 1.9 mg kg-1 for V. By SR - TXRF, the detection limit obtained for V was 1,4 µg L-1. For comparative reasons, the determination of residual metal content by Rutherford backscattering spectrometry (RBS) and total-reflection X-ray fluorescence spectrometry (TXRF) is also discussed.
4

Utilização da técnica de espectrometria de fluorescência de raios X para determinação de resíduos catalíticos em polímeros comerciais

Bichinho, Katia Messias January 2008 (has links)
A quantificação de teores de resíduos catalíticos em resinas produzidas pela indústria petroquímica constitui-se em etapa importante para controlar a qualidade do produto. Embora teoricamente ofereça condições interessantes, ressaltando a possibilidade de análise direta de matrizes poliméricas em corpos de prova com espessuras e tamanhos variados, procedimentos simplificados para a preparação das amostras, tempo e custo operacional baixos para a quantificação, uma rápida busca na literatura aponta que a técnica de XRF é pouco utilizada para esse fim. No presente trabalho, estudos foram desenvolvidos para avaliar a adequação da técnica de XRF para a quantificação de teores residuais de metais em polímeros comerciais. Para tanto, polietilenos produzidos por catalisadores Ziegler-Natta, Philips e metalocenos foram analisados por XRF. Padrões sintéticos a partir de cera comercial foram confeccionados visando à determinação quantitativa de resíduos metálicos e foram comparados àqueles preparados através de mistura de polietileno isento de metais, empregado como matriz, com óxido metálico pulverizado, seguido pelo processamento de moagem, para homogeneização adequada. A homogeneidade de distribuição dos metais nos padrões sintéticos foi avaliada estatisticamente e considerada adequada para aplicação em determinações quantitativas. Disponível comercialmente, o material de referência certificado ERM - EC680 (IRMM) foi utilizado nos estudos. Os limites de detecção obtidos para os metais estudados nas diferentes amostras de polietilenos por WDXRF foram: 12 mg kg-1 para Mg, 0,8 mg kg-1 para Ti, 1,6 mg kg-1 para Cr, 1,2 mg kg-1 para Zr e 1,9 mg kg-1 para V. Por SR - TXRF, o limite de detecção obtido para V foi igual a 1,4 µg L-1. Por razões comparativas, a determinação de resíduos metálicos foi avaliada também por RBS. / Commercial polyethylenes produced by Ziegler-Natta, Philips and metallocene technology were analyzed by X-ray fluorescence spectroscopy. Synthetic standards using wax matrix was shown to be suitable for the calibration curve in comparison to those prepared by milling and grinding virgin polymer mixed with standard metal oxide as matrix. The detection limits obtained for the studied metal in different polymers by WDXRF were: 12 mg kg-1 for Mg, 0.8 mg kg-1 for Ti, 1.6 mg kg-1 for Cr, 1.2 mg kg-1 for Zr and 1.9 mg kg-1 for V. By SR - TXRF, the detection limit obtained for V was 1,4 µg L-1. For comparative reasons, the determination of residual metal content by Rutherford backscattering spectrometry (RBS) and total-reflection X-ray fluorescence spectrometry (TXRF) is also discussed.
5

Desenvolvimento de método de determinação de cálcio, magnésio e zinco em amostras de óleo lubrificante por espectrometria de absorção atômica com chama

Zmozinski, Ariane Vanessa January 2010 (has links)
Neste trabalho foi desenvolvido um método para a determinação de Ca, Mg e Zn em óleos lubrificantes e quantificação por Espectrometria de Absorção Atômica com Chama (F AAS). As amostras foram diluídas com uma pequena quantidade de querosene de aviação (QAV), propanol e água formando uma solução de três componentes. Para a calibração, foram utilizados padrões inorgânicos aquosos. Para a avaliação da exatidão do método desenvolvido foi utilizado a norma ABNT NBR 14066, que consiste na diluição das amostras com QAV e quantificação por F AAS. Dois outros métodos para avaliar a exatidão foram empregados: digestão ácida e análise de material de referência certificado NIST (SRM 1084a). O método proposto apresentou as seguintes vantagens quando comparado com o método de referência: significativa redução do uso de QAV, maior estabilidade dos analitos no meio, utilização de padrões inorgânicos aquosos na calibração. Os valores dos limites de detecção para o Ca, Mg e Zn foram 1,3 μg g-1, 0,052 μg g-1 e 0,41 μg g-1 respectivamente. O método desenvolvido foi aplicado para amostras reais e os resultados foram concordantes com os obtidos pelos métodos de referência. / Lubricating oils are used to decrease wear and friction of movable parts. The presence of metals such as Ca, Mg and Zn show the addition of specific additives that improve the performance of these lubricants. In this work, a method for determination of Ca, Mg and Zn in lubricating oil by flame atomic absorption spectrometry (F AAS) was developed. The samples were diluted with a small quantity of aviation kerosene (AVK), n-propanol and water to form a three component solution before its introduction in the F AAS. Aqueous inorganic standards diluted in the same way have been used for calibration. To assess the accuracy of the new method, the comparison with the ABNT NBR 14066 standard method, which consist in diluting the sample with AVK and quantification by F AAS, was employed. Two other methods to evaluate the accuracy have also been used: the acid digestion method and the certified reference material NIST (SRM 1084a). The proposed method provides the following advantages when compared with the standard method: significant reduction of the use of AVK, higher stability of the analytes in the medium and application of aqueous organic standards for calibration. The limits of detection for Ca, Mg and Zn were 1.3 μg g-1, 0.052 μg g-1 and 0.41 μg g-1 respectively. The proposed method was applied to real samples and the results were consistent with those obtained by reference methods.
6

Estratégias de análise direta de amostras para determinação de elementos traço em biomassa e seus produtos de pirólise por espectrometria de absorção atômica de alta resolução com fonte contínua e forno de grafite

Duarte, Álvaro Tavares January 2014 (has links)
No presente trabalho foi investigada a viabilidade da aplicação da técnica de análise direta (com mínimo preparo de amostra) por espectrometria de absorção atômica de alta resolução com fonte continua e fomo de grafite (DS-HR-CS GF AAS). Métodos foram desenvolvidos para a determinação de chumbo, cádmio e cromo em amostras de biomassa, bio-óleo, água de pirólise e cinzas de biomassa (obtidos através de processo de pirólise ). As determinações foram realizadas sem adição de modificador quimico e utilizando calibração com soluções padrão aquosas. A determinação de cádmio e cromo foi realizada de maneira sequencial, ou seja, feita somente uma pesagem de amostra para determinação dos dois elementos, que possibilita trabalhar com uma menor quantidade de amostra e aumenta a velocidade analítica do método. Os métodos desenvolvidos se mostraram sensíveis, exatos, precisos e aplicáveis à rotina, com exceção do método desenvolvido para determinação sequencial de cádmio e cromo em amostras de bio-óleo, que apresentou limitações para determinação de cádmio. Após a determinação desses metais nas amostras analisadas, foi realizado um balanço de massas e estimado que a maior parte de chumbo e cromo presente na biomassa é eliminada para o ambiente durante o processo de pirólise, ficando uma parte significante retida nas cinzas. / In this work was investigated the feasibility of applying the technique of direct analysis (with a minimum sample preparation) by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry (HR-CS DS-GF AAS). Methods have been developed for the determination o f lead, cadmium and chromium in biomass, bio-oil, the aqueous phase o f the pyrolysis, and biomass ashes ( obtained by the pyrolysis process ). Ali measurements were performed without chemical modifier and using aqueous standard solutions for calibration. The determination of cadmium and chromium was performed in a sequential mode, determining both elements from the same sample aliquot, which allows work:ing with a small quantity of sample and increases the speed of the analytical method. The developed methods were sensitive, accurate and applicable to routine, with the exception of the method for sequential determination of cadmium and chromium in bio-oil, which presented lirnitations for the determination of cadmium. After determination ofthese metais in the samples, a mass balance was performed and estimated that most of the lead and chromium present in the biomass were emitted to the environment during the pyrolysis process, with a significant portion retained in the ashes.
7

Desenvolvimento de método analítico para determinação de metais em biodiesel e óleo vegetal por espectometria de absorção atômica com chama

Jesus, Alexandre de January 2008 (has links)
Os metais sódio, potássio, magnésio e cálcio podem danificar a estabilidade do biodiesel, pois tendem a reagir com ésteres e produzir sabão. Neste trabalho foi desenvolvido um método para a determinação desses metais em amostras de biodiesel e óleo vegetal, através da microemulsificação das amostras e determinação por espectrometria de absorção atômica com chama (F AAS). Amostras de biodiesel obtidas de diferentes fontes e de óleo vegetal foram analisadas. Foram obtidas microemulsões do tipo óleo-em-água pela mistura de biodiesel ou óleo vegetal, um surfactante, água e um co-surfactante. Na fase aquosa das microemulsões, foram adicionados HNO3 diluído e padrões inorgânicos dos metais para calibração. Vantagens em relação ao método de diluição com solvente, que é o método oficial adotado para as determinações (método de referência) foram observadas, tais como: maior estabilidade dos analitos no meio microemulsificado, possibilidade de calibração usando padrões aquosos nas microemulsões, limites de quantificação melhores e não utilização de solventes orgânicos carcinogênicos. Os resultados obtidos pelo método proposto foram concordantes com os resultados obtidos pelo método de referência, tornando assim o novo método uma eficiente alternativa para a determinação de metais em biodiesel, além de suprir as deficiências apresentadas pelo método de diluição com solvente. / The metals sodium, potassium, magnesium and calcium can damage biodiesel stability because these metals tend to react with esters and produce soap. In this work a method was developed for the determination of these metals in biodiesel and vegetable oil samples, through microemulsification of the samples and determination by flame atomic absorption spectrometry (F AAS). Biodiesel samples obtained from different sources and vegetable oil samples were analyzed. The water-in-oil microemulsion systems were obtained mixing biodiesel, a surfactant, water and a co-surfactant. Inorganic standards were added within the water portion to prepare the microemulsions used for calibration and nitric acid. The proposed method was compared with the method adopted by Brazilian’s regulations of dilution with organic solvent (reference method) for these determinations and some advantages were observed, as: higher stability of analytes in the microemulsions, feasibility of calibration using aqueous standards in the microemulsions, better limits of quantification and no use carcinogenic solvents. The results obtained by the new proposed method were a good agreement with the results obtained by the reference method. The new proposed method was an efficient alternative for the determination of metals in biodiesel, and overcome some deficiencies presented by the dilution method.
8

Desenvolvimento de métodos analíticos para a determinação de metais e metalóides utilizando pré-concentração no ponto nuvem e ICP OES

Depoi, Fernanda dos Santos January 2012 (has links)
Neste trabalho foram desenvolvidos métodos para pré-concentração de As, Bi, Cd, Hg, Pb, Sb, Se e lantanídeos mediante extração no ponto nuvem. Os elementos foram determinados por espectrometria de emissão óptica com fonte de plasma indutivamente acoplado (ICP OES) utilizando, para a introdução da amostra no plasma, diferentes sistemas (geração química de vapor - CVG para a determinação de As, Hg, Bi, Sb e Se; nebulização pneumática com dessolvatação do aerossol para a determinação de Bi e lantanídeos e nebulização pneumática convencional para a determinação de Cd, Pb e Se). Como agente complexante do As, Bi, Cd, Hg, Pb, Sb e Se foi utilizado o O,Odietilditiofosfato de amônio (DDTP), em meio HNO3 para a complexação de Bi, Cd e Pb e em meio HCl para a complexação de As, Hg, Sb e Se, sendo o octilfenoxipolietoxietanol (Triton X-114) usado como surfactante para todos os analitos. Diversos parâmetros foram avaliados no desenvolvimento do método de pré-concentração destes elementos, entre eles, as concentrações dos reagentes (HNO3, HCl, DDTP e Triton X-114). Os fatores de enriquecimento obtidos mediante a pré-concentração baseada na extração no ponto nuvem, foram 10, 18, 6, 12, 8, 11 e 8 para As, Bi, Cd, Hg, Pb, Sb e Se, respectivamente. Os limites de detecção (LDs) variaram de 0,04 μg L-1 (para o As) até 0,9 μg L-1 (para o Se). Os métodos desenvolvidos foram aplicados para a análise de mel de abelha, água de rio, água do mar, água de torneira, água de coco, urina, vinho branco, fertilizante químico, sementes (castanha do Pará, noz, amêndoa doce e avelã) e materiais de referência certificados (CRMs) de sedimento marinho (PACS-2), água enriquecida com diversos elementos (NIST 1643e), fígado de peixe (DOLT-3), folha de arbusto (GBW 07602), folha de tabaco (CTA-OTL-1) e tecido de ostra (NIST 1566b). Apesar das amostras analisadas possuírem matrizes complexas, os resultados obtidos estavam de acordo com os valores certificados ou as recuperações dos elementos em grande parte das amostras foram quantitativas, entre 90 e 110%. Os efeitos do surfactante e do solvente orgânico no plasma puderam ser reduzidos devido ao uso de sistema de CVG para Hg, As, Sb e Bi. No caso do Bi, foi utilizada também nebulização pneumática com dessolvatação do aerossol para a introdução da fase rica em surfactante no plasma, mas a mesma não pôde ser empregada para Cd e Pb, por causa da imprecisão dos resultados. Além disso, não foi possível eliminar a interferência da fase rica em surfactante e quantificar o Se mediante CVG. Dessa forma, para a determinação do elemento foi utilizada nebulização pneumática convencional para a introdução da fase rica em surfactante no plasma. A matriz Doehlert foi utilizada para a otimização dos fatores envolvidos na préconcentração de catorze elementos da série dos lantanídeos (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb e Lu) mediante CPE, usando-se o 1-(2-tenoil)-3,3,3- trifluoracetona (2-TTA) como complexante e o Triton X-114 como surfactante. Com o uso do sistema com dessolvatação do aerossol para a introdução da fase rica no plasma e o procedimento de pré-concentração, foram obtidos baixos LDs (entre 0,002 e 0,100 μg L-1) e bom fator de enriquecimento (entre 9 e 14). O método foi aplicado à determinação dos lantanídeos em água de rio, água mineral e água certificada (SPS-SW1). Foram obtidas recuperações quantitativas de todos os lantanídeos investigados, entre 88 e 108%. No entanto, para outras matrizes investigadas (cinza de carvão, folha de planta e sedimento marinho) foram observadas interferências na etapa de pré-concentração do analito, impossibilitando a determinação dos lantanídeos nessas amostras. / Methods were developed for preconcentration of As, Bi, Cd, Hg, Pb, Sb, Se and lanthanides using cloud point extraction (CPE). These elements were determined by inductively coupled plasma optical emission spectrometry (ICP OES), using different systems for sample introduction into the plasma (chemical vapor generation - CVG for As, Hg, Bi, Sb and Se determination; nebulization/aerosol desolvation for Bi and lanthanides determination and pneumatic nebulization for Cd, Pb and Se determination). The complexant used was O,O-diethyldithiophosphate ammonium (DDTP) in HNO3 medium for Bi, Cd, and Pb, and in HCl medium for As, Hg, Sb and Se, while octylphenoxypolyethoxyethanol (Triton X-114) was used as surfactant for all elements. Several parameters were evaluated in the development of the methods, including the influence of concentrations of HNO3, HCl, DDTP and Triton X-114. The enrichment factors obtained by using preconcentration based on the CPE were 10, 18, 6, 12, 8, 11 and 8 for As, Bi, Cd, Hg, Pb, Sb and Se, respectively. The limits of detection (LODs) ranged from 0.04 μg L-1 (for As) to 0.9 μg L-1 (for Se). The developed methods were applied to the analysis of honey, river water, sea water, tap water, coconut water, urine, white wine, chemical fertilizer, seeds (Brazil nut, walnut, almond and hazelnut) and the following certified reference materials: marine sediment (PACS-2), trace elements in water (NIST 1643e), dogfish liver (DOLT-3), bush branches and leaves (GBW 07602), oriental tobacco leaves (CTA-OTL-1) and oyster tissue (NIST 1566b). Although these samples have complex matrices, the results obtained were in accordance with certified value or the recoveries of the elements in most of samples were quantitative, between 90 and 110%. The effects of surfactant and organic solvent in the plasma could be reduced due to the use of CVG for introduction of the sample in the plasma for Hg, As, Sb and Bi. In the case of Bi, nebulization/aerosol desolvation was also used for introduction of the surfactant-rich phase into the plasma, but it was not possible for Cd and Pb due to poor precision. Moreover, it was not possible to eliminate the interference of the surfactant-rich phase and quantify Se using CVG. Thus, for Se determination pneumatic nebulization was used for introducing the sample into the plasma. A Doehlert matrix design was used for optimization of the factors involved in the preconcentration of fourteen elements of the lanthanides series (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu) by using CPE, and 1-(2-thenoyl)-3,3,3-trifluoraceton (2-TTA) as complexant and Triton X-114 as surfactant. By using nebulization/aerosol desolvation for introducing the surfactant rich phase into the plasma, low LODs were obtained (between 0.002 and 0.100 μg L-1) and good enrichment factor (between 9 and 14). The method was applied for determination of the investigated lanthanides in river water, mineral water and certified water (SPS-SW1). Quantitative recoveries of all investigated lanthanides were obtained, from 88 to 108%. However, interferences were observed for other samples investigated (coal ash, plant leaves, and marine sediment) in the preconcentration step, hindering lanthanides determination in these samples.
9

Estratégias analíticas para determinação sequencial de metais em vinhos por espectrometria de absorção atômica de alta resolução com fonte contínua por chama

Boschetti, Wiliam January 2012 (has links)
Neste trabalho foi desenvolvido e otimizado um método para determinação sequencial rápida por espectrometria de absorção atômica de alta resolução com fonte contínua por chama (HR-CS FS-FAAS) de metais em amostras de vinhos, produzidos em diferentes regiões do Brasil. As amostras foram obtidas de 8 regiões brasileiras diferentes: Serra Gaúcha, Vale dos Vinhedos, Pinto Bandeira, Campos de Cima da Serra, Campanha Gaúcha, Serra Catarinense, Oeste do Paraná e Vale do São Francisco. Os elementos avaliados foram: Be, Ca, Co, Cu, K, Li, Mn, Na, Rb e Sr. Estes metais têm grande importância nas propriedades organolépticas do vinho, assim como para produção de uvas de qualidade. A validação do método foi feita pelo estabelecimento de curvas de calibração, realização de ensaios de recuperação e comparação dos resultados encontrados por HR-CS FS-FAAS com aqueles obtidos por espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES). Padrões aquosos foram utilizados para a calibração e o coeficiente de correlação encontrado, para todos os analitos avaliados, foi maior que 0,9994. A partir das curvas de calibração os limites de detecção foram calculados para cada elemento: 44 μg L-1 para Cu, 5,0 μg L-1 para Li, 20 μg L-1 para Rb, 42 μg L-1 para Mn, 58 μg L-1 para Co, 15 μg L-1 para Sr, 23 μg L-1 para Be, 0,90 mg L-1 para Na, 4,4 mg L-1 para K e 0,92 mg L-1 para Ca. Ensaios de recuperação para cada analito foram realizados, encontrando recuperações entre 91 e 111%. A partir dos resultados encontrados, fazendo-se uso das técnicas de reconhecimento de padrões Análise por Componentes Principais (PCA) e Análise por Agrupamento Hierárquico (HCA) foi observada a formação de 7 grupos distintos, quando empregados os teores de K, Mn, Rb e Sr, dentre os 8 grupos (regiões do Brasil) avaliados. Com este conjunto de informações, portanto, é possível o monitoramento de fraudes e da qualidade do vinho produzido em cada região produtora. / In this work a method has been developed for the determination of metals in wine samples, produced in different regions of Brazil, using high-resolution continuum source fastsequential flame atomic absorption spectrometry (HR-CS FS-FAAS). The samples were obtained from eight different regions: Serra Gaúcha, Vale dos Vinhedos, Pinto Bandeira, Campos de Cima da Serra, Campanha Gaúcha, Serra Catarinense, Oeste do Paraná e Vale do São Francisco. The investigated elements were: Be, Ca, Co, Cu, K, Li, Mn, Na, Rb and Sr. These metals are important for the organoleptic properties of wine and for the production of grapes. The method was validated by recovery tests and comparison between the results obtained by HR-CS FS-FAAS and inductively coupled plasma optical emission spectrometry (ICP OES). Aqueous standards were used for calibration and the correlation coefficient found was higher than 0.9994 for all investigated elements. The detection limits were calculated from the calibration curves for each analyte: 44 μg L-1 for Cu, 5.0 μg L-1for Li, 20 μg L-1 for Rb, 42 μg L-1 for Mn, 58 μg L-1 for Co, 15 μg L-1 for Sr, 23 μg L-1 for Be, 0.90 mg L-1 for Na, 4.4 mg L-1 for K and 0.92 mg L-1 for Ca. The recovery tests showed results between 91 and 111%. After method validation the samples were evaluated. With the results obtained and using pattern recognition techniques Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) was possible to find seven different groups, evaluating K, Mn, Rb and Sr concentration values, among the eight original groups (Brazilian regions) evaluated. Finally, using all the information obtained in this work, it’s possible to control frauds and the wine produced quality.
10

Estratégias de análise direta de amostras para determinação de elementos traço em biomassa e seus produtos de pirólise por espectrometria de absorção atômica de alta resolução com fonte contínua e forno de grafite

Duarte, Álvaro Tavares January 2014 (has links)
No presente trabalho foi investigada a viabilidade da aplicação da técnica de análise direta (com mínimo preparo de amostra) por espectrometria de absorção atômica de alta resolução com fonte continua e fomo de grafite (DS-HR-CS GF AAS). Métodos foram desenvolvidos para a determinação de chumbo, cádmio e cromo em amostras de biomassa, bio-óleo, água de pirólise e cinzas de biomassa (obtidos através de processo de pirólise ). As determinações foram realizadas sem adição de modificador quimico e utilizando calibração com soluções padrão aquosas. A determinação de cádmio e cromo foi realizada de maneira sequencial, ou seja, feita somente uma pesagem de amostra para determinação dos dois elementos, que possibilita trabalhar com uma menor quantidade de amostra e aumenta a velocidade analítica do método. Os métodos desenvolvidos se mostraram sensíveis, exatos, precisos e aplicáveis à rotina, com exceção do método desenvolvido para determinação sequencial de cádmio e cromo em amostras de bio-óleo, que apresentou limitações para determinação de cádmio. Após a determinação desses metais nas amostras analisadas, foi realizado um balanço de massas e estimado que a maior parte de chumbo e cromo presente na biomassa é eliminada para o ambiente durante o processo de pirólise, ficando uma parte significante retida nas cinzas. / In this work was investigated the feasibility of applying the technique of direct analysis (with a minimum sample preparation) by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry (HR-CS DS-GF AAS). Methods have been developed for the determination o f lead, cadmium and chromium in biomass, bio-oil, the aqueous phase o f the pyrolysis, and biomass ashes ( obtained by the pyrolysis process ). Ali measurements were performed without chemical modifier and using aqueous standard solutions for calibration. The determination of cadmium and chromium was performed in a sequential mode, determining both elements from the same sample aliquot, which allows work:ing with a small quantity of sample and increases the speed of the analytical method. The developed methods were sensitive, accurate and applicable to routine, with the exception of the method for sequential determination of cadmium and chromium in bio-oil, which presented lirnitations for the determination of cadmium. After determination ofthese metais in the samples, a mass balance was performed and estimated that most of the lead and chromium present in the biomass were emitted to the environment during the pyrolysis process, with a significant portion retained in the ashes.

Page generated in 0.0553 seconds