1

Aplicação da análise modal estática no estudo de estabilidade de tensão /

Amorim, Estelio da Silva. January 2011 (has links)
Orientador: Dilson Amancio Alves / Banca: Carlos Roberto Minussi / Banca: Luiz Carlos Pereira da Silva / Resumo: O objetivo do trabalho proposto é o de apresentar aplicações práticas da técnica de análise modal na avaliação da estabilidade de tensão e à redução da perda total de potência reativa na transmissão. A análise modal tem demonstrado ser uma ferramenta de análise estática muito útil que pode ser utilizada para identificar áreas propensas à instabilidade de tensão. Seus resultados são usados para identificar as medidas de reforço mais adequadas para aumentar a margem de estabilidade de tensão de sistemas elétricos de potência. A melhor localização para a instalação de compensação reativa shunt e série é determinada baseada nos fatores de participação de barra e de ramos, respectivamente. Outros objetivos deste trabalho são os de apresentar uma metodologia alternativa para a alocação de bancos de capacitores shunt, e o efeito da compensação de bancos de capacitores série na margem de carregamento. Os objetivos são à redução da perda total de potência reativa na transmissão e o aumento na margem de carregamento do sistema. Os valores dos montantes de compensação reativa shunt a serem alocados são determinados com base nas curvas de perda total de potência reativa na transmissão versus magnitude de tensão da barra. No caso da compensação série, o valor da reatância capacitiva escolhido é limitado pelo valor prático de compensação que é da ordem de 80%. Também são investigados os efeitos individuais que cada um destes procedimentos traz para o sistema. Entre os efeitos investigados estão: a redução das perdas reativas, a variação na margem de estabilidade estática de tensão, e a melhoria do perfil de tensão. Os resultados obtidos para os sistemas do IEEE (14, 57 e 118 barras) mostram que o procedimento conduz a uma sensível redução da perda total de potência... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of the proposed work is to present practical applications of the modal analysis technique applied to voltage stability assessment and reactive power losses reduction. Modal analysis has proven to be a useful steady-state analysis approach which can be applied to identify areas prone to voltage instability. Its results are used to identify the most effective remedial actions to increase system voltage stability margin. The best location for placing shunt and series capacitor is determined based on the bus and branch participations factors respectively. Other goals of the proposed work are to present an alternative procedure to the allocation of shunt capacitor, and the effects of series capacitor compensation on the system loading margin. The objectives are the total reactive power losses reduction in the transmission and the loading margin increase. The values of shunt reactive compensation to be allocated are determined based on the curve of total transmission reactive power losses versus bus voltage magnitude. In case of series compensation, the chosen reactive capacitance values are limited by a practical upper limit of series compensation degree of 80%. The individual effects that each one of these procedures brings for the system are also investigated. Among the investigated effects are: the reduction in the total reactive power losses, the changes in the static voltage stability margin, and the improvement of voltage profile. The results obtained for the IEEE system (14, 57 and 118 bus) show that the procedure leads to a sensible reduction of total reactive power losses and simultaneously, an improvement in the voltage profile and load margin increase. / Mestre
2

Fluxo de carga continuado considerando o controle de intercâmbio entre áreas

Avila Carhuallanqui, Hebert [UNESP] 18 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-18Bitstream added on 2014-06-13T19:08:06Z : No. of bitstreams: 1 avilacarhuallanqui_h_me_ilha.pdf: 1893312 bytes, checksum: ec763667b361d0d73bde9d8c3f0c7265 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O cálculo da capacidade de transferência de potência em sistemas interligados é calculado considerando o sistema como uma única área e uma única barra de folga. A máxima potência ativa que poderia ser transferida pelas linhas de intercâmbio, sem problemas relacionados com a estabilidade estática de tensão, é obtida efetuando-se a soma dos correspondentes fluxos nas linhas de intercâmbio no ponto de operação correspondente a máxima potência ativa. Cabe ressaltar que neste caso, o sistema de equações não inclui as equações do controle de intercâmbio entre áreas (CIA). Neste trabalho propõe-se a inclusão do CIA no fluxo de carga continuado de forma a possibilitar com isso a obtenção da capacidade de transferência de potência entre as diversas áreas, considerando múltiplas barras folga por área. Cada área atua como um sistema independente controlando seu intercâmbio no processo de carregamento do sistema. O objetivo é o de mostrar os efeitos resultantes desta inclusão sobre a capacidade de transferência de potência dentro de uma mesma área ou entre as diversas áreas. Utilizando-se o fluxo de carga continuado proposto, apresentam-se os resultados obtidos para os sistemas de IEEE de 9 barras, o New England 30 barras e o IEEE de 118 barras, os quais foram divididos em áreas com o objetivo de evidenciar as diferenças entre as margens de carregamento e de transferência de potência obtidas sem e com as restrições impostas pelo CIA. Foram realizados estudos sobre a capacidade de transferência de potência considerando-se duas formas distintas de carregamento e contingências de ramos do sistema. Dos resultados obtidos se constata a importância da consideração das equações do CIA nas análises relacionadas com a estabilidade estática de tensão, as quais podem conduzir, dependendo... / The calculation of power transfer capability of interconnected systems is calculated considering the system as a single area and a single bus slack. The maximum power active that could be transferred through the tie lines, without the problems related with the static voltage stability is obtained by making the sum of the corresponding flows the tie lines in operation point corresponding the maximum power active. In this case, the system of equations does not include equations of area interchange control (AIC). This work proposes the inclusion of AIC in continuation power flow, with this is possible to obtain the power transfer capacity between different areas, and multiple slacks buses per area. Each area acts as an independent system controlling its exchange in the process of loading system. The objective is to show the effects of this inclusion on power transfer capability within the same area or between different areas. Using the proposed continuation power flow, shows the results obtained in the IEEE 9 buses, New England 30 buses and IEEE 118 buses systems, which were divided in areas with the objective of evidencing the differences between the margins of loading and transfer power obtained with and without the restrictions imposed by the AIC. We realize studies about power transfer capacity considering two different ways of loading the system and branches contingencies of the system. The results obtained show the importance the consideration equations of AIC in the analysis related to the static voltage stability, which may lead, in each case and the system in analysis, an increase or decrease active power transfer capability. The analysis also enables a better understanding of the effects of the loop flow, that are... (Complete abstract click electronic access below)
3

Fluxo de carga continuado considerando o controle de intercâmbio entre áreas /

Avila Carhuallanqui, Hebert. January 2012 (has links)
Orientador: Dilson Amancio Alves / Banca: Marcos Julio Rider Flores / Banca: Rogério Rocha Matarucco / Resumo: O cálculo da capacidade de transferência de potência em sistemas interligados é calculado considerando o sistema como uma única área e uma única barra de folga. A máxima potência ativa que poderia ser transferida pelas linhas de intercâmbio, sem problemas relacionados com a estabilidade estática de tensão, é obtida efetuando-se a soma dos correspondentes fluxos nas linhas de intercâmbio no ponto de operação correspondente a máxima potência ativa. Cabe ressaltar que neste caso, o sistema de equações não inclui as equações do controle de intercâmbio entre áreas (CIA). Neste trabalho propõe-se a inclusão do CIA no fluxo de carga continuado de forma a possibilitar com isso a obtenção da capacidade de transferência de potência entre as diversas áreas, considerando múltiplas barras folga por área. Cada área atua como um sistema independente controlando seu intercâmbio no processo de carregamento do sistema. O objetivo é o de mostrar os efeitos resultantes desta inclusão sobre a capacidade de transferência de potência dentro de uma mesma área ou entre as diversas áreas. Utilizando-se o fluxo de carga continuado proposto, apresentam-se os resultados obtidos para os sistemas de IEEE de 9 barras, o New England 30 barras e o IEEE de 118 barras, os quais foram divididos em áreas com o objetivo de evidenciar as diferenças entre as margens de carregamento e de transferência de potência obtidas sem e com as restrições impostas pelo CIA. Foram realizados estudos sobre a capacidade de transferência de potência considerando-se duas formas distintas de carregamento e contingências de ramos do sistema. Dos resultados obtidos se constata a importância da consideração das equações do CIA nas análises relacionadas com a estabilidade estática de tensão, as quais podem conduzir, dependendo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The calculation of power transfer capability of interconnected systems is calculated considering the system as a single area and a single bus slack. The maximum power active that could be transferred through the tie lines, without the problems related with the static voltage stability is obtained by making the sum of the corresponding flows the tie lines in operation point corresponding the maximum power active. In this case, the system of equations does not include equations of area interchange control (AIC). This work proposes the inclusion of AIC in continuation power flow, with this is possible to obtain the power transfer capacity between different areas, and multiple slacks buses per area. Each area acts as an independent system controlling its exchange in the process of loading system. The objective is to show the effects of this inclusion on power transfer capability within the same area or between different areas. Using the proposed continuation power flow, shows the results obtained in the IEEE 9 buses, New England 30 buses and IEEE 118 buses systems, which were divided in areas with the objective of evidencing the differences between the margins of loading and transfer power obtained with and without the restrictions imposed by the AIC. We realize studies about power transfer capacity considering two different ways of loading the system and branches contingencies of the system. The results obtained show the importance the consideration equations of AIC in the analysis related to the static voltage stability, which may lead, in each case and the system in analysis, an increase or decrease active power transfer capability. The analysis also enables a better understanding of the effects of the loop flow, that are... (Complete abstract click electronic access below) / Mestre
4

Proposta de parametrização para o fluxo de carga continuado visando redução de perdas na transmissão e o aumento da margem estática de estabilidade de tensão /

Malange, Francisco Carlos Vieira. January 2008 (has links)
Orientador: Dílson Amâncio Alves / Banca: Luiz Fernando Bovolato / Banca: Luis Carlos Origa de Oliveira / Banca: Vivaldo Fernando da Costa / Banca: Eduardo Nobuhiro Asada / Resumo: Este trabalho apresenta uma metodologia alternativa para a melhoria da margem de carregamento e redução da perda total de potência ativa com base no método da continuação. Para atingir esta meta, uma equação de parametrização baseada na perda de potência ativa total e as equações da potência reativa nas barras de geração são acrescentadas às equações de fluxo de carga convencional. As tensões nas barras PV são consideradas como variáveis de controle e um novo parâmetro é escolhido para reduzir as perdas de potência ativa nas linhas de transmissão. Os resultados mostram que este procedimento, em geral, conduz a um aumento no ponto de máximo carregamento e por conseguinte, melhoria na margem estática da estabilidade de tensão. Este procedimento também leva a uma redução nos custos operacionais e, simultaneamente, uma melhoria no perfil da tensão. / Abstract: This work presents an alternative methodology for loading margin improvement and total real power losses reduction by using a continuation method. In order to attain this goal, a parameterizing equation based on the total real power losses and the equations of the reactive power at the slack and generation buses are added to the conventional Power Flow equations. The voltages at these buses are considered as control variables and a new parameter is chosen with to reduce the real power losses in the transmission lines. The results show that this procedure leads to maximum loading point increase and consequently, in static voltage stability margin improvement. Besides, this procedure also takes to a reduction in the operational costs and, simultaneously, to voltage profile improvement. / Doutor
5

Aplicação da análise modal estática no estudo de estabilidade de tensão

Amorim, Estelio da Silva [UNESP] 14 January 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-01-14Bitstream added on 2014-06-13T18:08:29Z : No. of bitstreams: 1 amorim_es_me_ilha.pdf: 2160628 bytes, checksum: 3be5e9c0540f3af6109d0248dc52ede1 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do trabalho proposto é o de apresentar aplicações práticas da técnica de análise modal na avaliação da estabilidade de tensão e à redução da perda total de potência reativa na transmissão. A análise modal tem demonstrado ser uma ferramenta de análise estática muito útil que pode ser utilizada para identificar áreas propensas à instabilidade de tensão. Seus resultados são usados para identificar as medidas de reforço mais adequadas para aumentar a margem de estabilidade de tensão de sistemas elétricos de potência. A melhor localização para a instalação de compensação reativa shunt e série é determinada baseada nos fatores de participação de barra e de ramos, respectivamente. Outros objetivos deste trabalho são os de apresentar uma metodologia alternativa para a alocação de bancos de capacitores shunt, e o efeito da compensação de bancos de capacitores série na margem de carregamento. Os objetivos são à redução da perda total de potência reativa na transmissão e o aumento na margem de carregamento do sistema. Os valores dos montantes de compensação reativa shunt a serem alocados são determinados com base nas curvas de perda total de potência reativa na transmissão versus magnitude de tensão da barra. No caso da compensação série, o valor da reatância capacitiva escolhido é limitado pelo valor prático de compensação que é da ordem de 80%. Também são investigados os efeitos individuais que cada um destes procedimentos traz para o sistema. Entre os efeitos investigados estão: a redução das perdas reativas, a variação na margem de estabilidade estática de tensão, e a melhoria do perfil de tensão. Os resultados obtidos para os sistemas do IEEE (14, 57 e 118 barras) mostram que o procedimento conduz a uma sensível redução da perda total de potência... / The objective of the proposed work is to present practical applications of the modal analysis technique applied to voltage stability assessment and reactive power losses reduction. Modal analysis has proven to be a useful steady-state analysis approach which can be applied to identify areas prone to voltage instability. Its results are used to identify the most effective remedial actions to increase system voltage stability margin. The best location for placing shunt and series capacitor is determined based on the bus and branch participations factors respectively. Other goals of the proposed work are to present an alternative procedure to the allocation of shunt capacitor, and the effects of series capacitor compensation on the system loading margin. The objectives are the total reactive power losses reduction in the transmission and the loading margin increase. The values of shunt reactive compensation to be allocated are determined based on the curve of total transmission reactive power losses versus bus voltage magnitude. In case of series compensation, the chosen reactive capacitance values are limited by a practical upper limit of series compensation degree of 80%. The individual effects that each one of these procedures brings for the system are also investigated. Among the investigated effects are: the reduction in the total reactive power losses, the changes in the static voltage stability margin, and the improvement of voltage profile. The results obtained for the IEEE system (14, 57 and 118 bus) show that the procedure leads to a sensible reduction of total reactive power losses and simultaneously, an improvement in the voltage profile and load margin increase.
6

Proposta de parametrização para o fluxo de carga continuado visando redução de perdas na transmissão e o aumento da margem estática de estabilidade de tensão

Malange, Francisco Carlos Vieira [UNESP] 07 November 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-11-07Bitstream added on 2014-06-13T19:47:13Z : No. of bitstreams: 1 malange_fcv_dr_ilha.pdf: 1077798 bytes, checksum: 6e2455ed107dc7931eb5bc7473ecce8a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho apresenta uma metodologia alternativa para a melhoria da margem de carregamento e redução da perda total de potência ativa com base no método da continuação. Para atingir esta meta, uma equação de parametrização baseada na perda de potência ativa total e as equações da potência reativa nas barras de geração são acrescentadas às equações de fluxo de carga convencional. As tensões nas barras PV são consideradas como variáveis de controle e um novo parâmetro é escolhido para reduzir as perdas de potência ativa nas linhas de transmissão. Os resultados mostram que este procedimento, em geral, conduz a um aumento no ponto de máximo carregamento e por conseguinte, melhoria na margem estática da estabilidade de tensão. Este procedimento também leva a uma redução nos custos operacionais e, simultaneamente, uma melhoria no perfil da tensão. / This work presents an alternative methodology for loading margin improvement and total real power losses reduction by using a continuation method. In order to attain this goal, a parameterizing equation based on the total real power losses and the equations of the reactive power at the slack and generation buses are added to the conventional Power Flow equations. The voltages at these buses are considered as control variables and a new parameter is chosen with to reduce the real power losses in the transmission lines. The results show that this procedure leads to maximum loading point increase and consequently, in static voltage stability margin improvement. Besides, this procedure also takes to a reduction in the operational costs and, simultaneously, to voltage profile improvement.
7

Método da continuação aplicado na análise de contingência de linhas de transmissão

Matarucco, Rogério Rocha [UNESP] 18 February 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-02-18Bitstream added on 2014-06-13T20:07:53Z : No. of bitstreams: 1 matarucco_rr_dr_ilha.pdf: 2669428 bytes, checksum: c42a359efd2169b25baa0b6c3a967339 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho apresenta dois métodos para a análise estática de contingências em Sistemas Elétricos de Potência utilizando o Método da Continuação. No primeiro método a margem de carregamento pós-contingência é obtida a partir do ponto de máximo carregamento do caso base. A magnitude de tensão de uma barra qualquer é usada como parâmetro na etapa de parametrização do fluxo de carga continuado. O ramo selecionado para avaliação da contingência é parametrizado por um fator de escalonamento que possibilita a remoção gradual do ramo e assegura a convergência nos casos em que o método diverge para a retirada total da linha de transmissão. Em geral, para a maioria das contingências analisadas são necessárias poucas iterações para a determinação do ponto de máximo carregamento pós-contingência. Mostra-se que o método pode ser usado como uma técnica alternativa para a averiguação e até mesmo para a obtenção da lista de contingências críticas fornecida pela função de análise de segurança de sistemas elétricos. No outro método, o qual obtém o ponto de máximo carregamento de pós-contingência a partir do caso base, as variáveis ângulo de fase e magnitude de tensão de uma barra k qualquer, e a perda total de potência ativa, são propostas como parâmetros para a etapa de parametrização do fluxo de carga continuado utilizado na averiguação da lista de contingências críticas fornecida pela função de análise de segurança de sistemas elétricos. Nos casos em que há divergência do fluxo de carga, o método proposto possibilita confirmar se esta ocorre devido à deficiência numérica do método em si ou a inexistência de um ponto de operação factível de pós-contingência. O uso da perda total de potência ativa como parâmetro traz como vantagem a possibilidade da determinação de pontos além do ponto de singularidade sem a necessidade... / This work presents two methods for static contingency analysis of electric power systems by using Continuation Methods. In the first the post-contingency loading margin is obtained from the base case maximum loading point. The voltage magnitude of any bus can be used as a parameter in the parameterization step of the proposed continuation power flow. The branch selected for contingency evaluation is parameterized by a scaling factor which allows its the gradual removal and assures the continuation power flow convergence for the cases where the method would diverge for the complete transmission line removal. In general, for most of the analyzed contingencies little iterations are necessary for the determination of the post-contingency maximum loading point. It is shown that the method can be used as an alternative technique to verify and even to obtain the list of critical contingencies supplied by the electric power systems security analysis function. In the other method, which obtains the maximum loading point from the base case, new parameters, namely the voltage magnitudes, phase angles and the total power losses, for evaluating the effects of branch outages. The approach can be used as a verification tool after a list of critical contingencies had been ranked according to their severities by the contingency selection functions. It is then possible to find whether the non-convergence of a power flow is due to a numerical problem or to an infeasible operating situation. The mains advantage of using the total real power losses as a parameter is that it is not necessary to change parameters during the solutions tracing until beyond the simple limit point, where the original Jacobian is singular. The proposed methods facilitate the development and the implementation of continuation methods for contingencies analysis
8

Proposição de uma técnica de parametrização geométrica para o fluxo de carga continuado /

Garbelini, Enio. January 2008 (has links)
Orientador: Dílson Amâncio Alves / Banca: Carlos Roberto Minussi / Banca: Francisco Villarreal Alvarado / Banca: Vivaldo Fernando da Costa / Banca: Walmir de Freitas Filho / Resumo: O fluxo de carga convencional é considerado inadequado para a obtenção do ponto de máximo carregamento devido a singularidade da matriz Jacobiana. Os métodos da continuação são ferramentas eficientes para a solução deste tipo de problema, e diferentes parametrizações são utilizadas para evitar a singularidade da matriz. Neste trabalho apresentase uma técnica de parametrização geométrica que possibilita o traçado completo das curvas PV sem os problemas de mal condicionamento. A técnica proposta associa a robustez com a simplicidade e a facilidade de compreensão. A singularidade da matriz Jacobiana é eliminada pela adição da equação de uma reta que passa por um ponto no plano formado pelas variáveis perdas de potência ativa totais e o fator de carregamento, dois parâmetros físicos de fácil compreensão. A técnica, aplicada aos sistemas do IEEE (14, 30, 57, 118 e 300 barras) e ao sistema brasileiro sul-sudeste (638 e 787 barras), mostra que as características do fluxo de carga não só são preservadas, mas também melhoradas. Diversos testes são realizados para proporcionar a comparação do desempenho do esquema de parametrização proposto para o método do fluxo de carga continuado. / Abstract: The conventional Newton's method has been considered inadequate to obtain the maximum loading point of power systems due to the Jacobian matrix singularity. Continuation methods are efficient tools for solving this kind of problem, and different parameterizations are used to avoid the matrix singularity. This paper presents a new geometric parameterization scheme that allows the complete tracing of the PV curves without ill-conditioning problems. The proposed technique associates the robustness to the simplicity and easy understanding. The Jacobian matrix singularity is overcome by the addition of a line equation, which passes through a point in the plane, determined by the real power losses and loading factor variables, two parameters with clear physical meaning. The application of this new technique to the IEEE systems (14, 30, 57, 118 and 300 buses) and to the Brazilian systems south-southeast (638 and 787 buses) shows that the characteristics of the conventional Newton's method are not only preserved but also improved. Several tests are carried out to compare the performance of the proposed parameterization scheme for the continuation power flow method. / Doutor
9

Método da continuação aplicado na análise de contingência de linhas de transmissão /

Matarucco, Rogério Rocha. January 2010 (has links)
Orientador: Dilson Amancio Alves / Banca: Percival Bueno de Araujo / Banca: Carlos Roberto Minussi / Banca: Geraldo Roberto Martins da Costa / Banca: Luiz Carlos Pereira da Silva / Resumo: Este trabalho apresenta dois métodos para a análise estática de contingências em Sistemas Elétricos de Potência utilizando o Método da Continuação. No primeiro método a margem de carregamento pós-contingência é obtida a partir do ponto de máximo carregamento do caso base. A magnitude de tensão de uma barra qualquer é usada como parâmetro na etapa de parametrização do fluxo de carga continuado. O ramo selecionado para avaliação da contingência é parametrizado por um fator de escalonamento que possibilita a remoção gradual do ramo e assegura a convergência nos casos em que o método diverge para a retirada total da linha de transmissão. Em geral, para a maioria das contingências analisadas são necessárias poucas iterações para a determinação do ponto de máximo carregamento pós-contingência. Mostra-se que o método pode ser usado como uma técnica alternativa para a averiguação e até mesmo para a obtenção da lista de contingências críticas fornecida pela função de análise de segurança de sistemas elétricos. No outro método, o qual obtém o ponto de máximo carregamento de pós-contingência a partir do caso base, as variáveis ângulo de fase e magnitude de tensão de uma barra k qualquer, e a perda total de potência ativa, são propostas como parâmetros para a etapa de parametrização do fluxo de carga continuado utilizado na averiguação da lista de contingências críticas fornecida pela função de análise de segurança de sistemas elétricos. Nos casos em que há divergência do fluxo de carga, o método proposto possibilita confirmar se esta ocorre devido à deficiência numérica do método em si ou a inexistência de um ponto de operação factível de pós-contingência. O uso da perda total de potência ativa como parâmetro traz como vantagem a possibilidade da determinação de pontos além do ponto de singularidade sem a necessidade...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work presents two methods for static contingency analysis of electric power systems by using Continuation Methods. In the first the post-contingency loading margin is obtained from the base case maximum loading point. The voltage magnitude of any bus can be used as a parameter in the parameterization step of the proposed continuation power flow. The branch selected for contingency evaluation is parameterized by a scaling factor which allows its the gradual removal and assures the continuation power flow convergence for the cases where the method would diverge for the complete transmission line removal. In general, for most of the analyzed contingencies little iterations are necessary for the determination of the post-contingency maximum loading point. It is shown that the method can be used as an alternative technique to verify and even to obtain the list of critical contingencies supplied by the electric power systems security analysis function. In the other method, which obtains the maximum loading point from the base case, new parameters, namely the voltage magnitudes, phase angles and the total power losses, for evaluating the effects of branch outages. The approach can be used as a verification tool after a list of critical contingencies had been ranked according to their severities by the contingency selection functions. It is then possible to find whether the non-convergence of a power flow is due to a numerical problem or to an infeasible operating situation. The mains advantage of using the total real power losses as a parameter is that it is not necessary to change parameters during the solutions tracing until beyond the simple limit point, where the original Jacobian is singular. The proposed methods facilitate the development and the implementation of continuation methods for contingencies analysis / Doutor
10

Proposição de uma técnica de parametrização geométrica para o fluxo de carga continuado

Garbelini, Enio [UNESP] 06 November 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-11-06Bitstream added on 2014-06-13T19:00:48Z : No. of bitstreams: 1 garbelini_e_dr_ilha.pdf: 758680 bytes, checksum: 9f08146d542679d2c1da479912ffd576 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O fluxo de carga convencional é considerado inadequado para a obtenção do ponto de máximo carregamento devido a singularidade da matriz Jacobiana. Os métodos da continuação são ferramentas eficientes para a solução deste tipo de problema, e diferentes parametrizações são utilizadas para evitar a singularidade da matriz. Neste trabalho apresentase uma técnica de parametrização geométrica que possibilita o traçado completo das curvas PV sem os problemas de mal condicionamento. A técnica proposta associa a robustez com a simplicidade e a facilidade de compreensão. A singularidade da matriz Jacobiana é eliminada pela adição da equação de uma reta que passa por um ponto no plano formado pelas variáveis perdas de potência ativa totais e o fator de carregamento, dois parâmetros físicos de fácil compreensão. A técnica, aplicada aos sistemas do IEEE (14, 30, 57, 118 e 300 barras) e ao sistema brasileiro sul-sudeste (638 e 787 barras), mostra que as características do fluxo de carga não só são preservadas, mas também melhoradas. Diversos testes são realizados para proporcionar a comparação do desempenho do esquema de parametrização proposto para o método do fluxo de carga continuado. / The conventional Newton’s method has been considered inadequate to obtain the maximum loading point of power systems due to the Jacobian matrix singularity. Continuation methods are efficient tools for solving this kind of problem, and different parameterizations are used to avoid the matrix singularity. This paper presents a new geometric parameterization scheme that allows the complete tracing of the PV curves without ill-conditioning problems. The proposed technique associates the robustness to the simplicity and easy understanding. The Jacobian matrix singularity is overcome by the addition of a line equation, which passes through a point in the plane, determined by the real power losses and loading factor variables, two parameters with clear physical meaning. The application of this new technique to the IEEE systems (14, 30, 57, 118 and 300 buses) and to the Brazilian systems south-southeast (638 and 787 buses) shows that the characteristics of the conventional Newton’s method are not only preserved but also improved. Several tests are carried out to compare the performance of the proposed parameterization scheme for the continuation power flow method.