Spelling suggestions: "subject:"phaseninterferometrie"" "subject:"gitterinterferometrie""
1 |
A time domain optical coherence tomograph for laboratory investigations on phantoms and human skin / Utveckling av en tidsupplöst optisk koherenstomograf för undersökning av fantom och hudFreiberger, Manuel January 2005 (has links)
<p>Optical coherence tomography is an imaging modality with an outstanding resolution. During the project, a time domain OCT system based on a Michelson fibre interferometer was implemented and put into operation. A super-luminescent diode with a centre wavelength of 1295nm and a bandwidth of 45nm was selected as light source and a linear variable delay line as reference. Basic tests were made on phantoms constructed of filter foils and on gel-like agar slices with optical properties similar to human tissue. It was shown that the achievable resolution was at least 36um and can be increased. The system can easily be enhanced to create two-dimensional images.</p> / <p>Optische Kohärenztomographie ist ein bildgebendes Verfahren mit einer hervorragenden räumlichen Auflösung. Im Laufe des Projekts wurde ein OCT-System basierend auf einem faseroptischen Michelson-Interferometer implementiert und in Betrieb genommen. Als Lichtquelle wurde eine Superlumineszenzdiode mit einer Mittenwellenlänge von 1295nm und einer Bandbreite von 45nm gewählt. Eine variable optische Verzögerungsleitung diente als Referenz. Erste Messungen an Filterfolien und gelähnlichen Agarphantomen, die die optischen Eigenschaften von menschlichem Gewebe nachbildeten, lieferten eine räumliche Auflösung von mindestens 36um. Durch die modulare Bauweise ist das System leicht für zweidimensionale Aufnahmen erweiterbar.</p>
|
2 |
A time domain optical coherence tomograph for laboratory investigations on phantoms and human skin / Utveckling av en tidsupplöst optisk koherenstomograf för undersökning av fantom och hudFreiberger, Manuel January 2005 (has links)
Optical coherence tomography is an imaging modality with an outstanding resolution. During the project, a time domain OCT system based on a Michelson fibre interferometer was implemented and put into operation. A super-luminescent diode with a centre wavelength of 1295nm and a bandwidth of 45nm was selected as light source and a linear variable delay line as reference. Basic tests were made on phantoms constructed of filter foils and on gel-like agar slices with optical properties similar to human tissue. It was shown that the achievable resolution was at least 36um and can be increased. The system can easily be enhanced to create two-dimensional images. / Optische Kohärenztomographie ist ein bildgebendes Verfahren mit einer hervorragenden räumlichen Auflösung. Im Laufe des Projekts wurde ein OCT-System basierend auf einem faseroptischen Michelson-Interferometer implementiert und in Betrieb genommen. Als Lichtquelle wurde eine Superlumineszenzdiode mit einer Mittenwellenlänge von 1295nm und einer Bandbreite von 45nm gewählt. Eine variable optische Verzögerungsleitung diente als Referenz. Erste Messungen an Filterfolien und gelähnlichen Agarphantomen, die die optischen Eigenschaften von menschlichem Gewebe nachbildeten, lieferten eine räumliche Auflösung von mindestens 36um. Durch die modulare Bauweise ist das System leicht für zweidimensionale Aufnahmen erweiterbar.
|
Page generated in 0.0743 seconds