• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação clínica da efetividade de mascaramento de manchas fluoróticas: microabrasão x infiltração resinosa / Clinical evaluation of fluorotic stains masking capability: microabrasion x resin infiltration

Schubert, Edward Werner 26 March 2018 (has links)
Submitted by Eunice Novais (enovais@uepg.br) on 2018-06-07T17:48:37Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Schubert, Edward W.pdf: 1787844 bytes, checksum: 2e08c3f7dcbfcfcaac48fc1d884ea8b5 (MD5) / Made available in DSpace on 2018-06-07T17:48:37Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Schubert, Edward W.pdf: 1787844 bytes, checksum: 2e08c3f7dcbfcfcaac48fc1d884ea8b5 (MD5) Previous issue date: 2018-03-26 / Este estudo avaliou a efetividade do mascaramento de manchas de fluorose utilizando a técnica da infiltração resinosa em comparação com a técnica de microabrasão. Método: Vinte pacientes, de 12 a 16 anos, apresentando manchas de fluorose no esmalte dental, foram selecionados e divididos randomicamente em dois grupos (n=10): microabrasão e infiltração resinosa. Ambas as técnicas foram executadas, segundo as orientações do fabricante. A avaliação ocorreu de três formas distintas: quantitativa, qualitativa e “Grau de satisfação do paciente/responsável”. Fotografias estandardizadas foram feitas (baseline e 1 semana após a intervenção), para serem analisadas utilizando o software Adobe Photoshop CS5, para obter os dados para o cálculo dos valores de ΔL, Δa, Δb e ΔE, nos pontos onde a mancha da fluorose era mais intensa, em cada um dos dentes tratados. Para avaliar a otimização estética obtida nas manchas fluoróticas dois avaliadores cegos e calibrados, basearam-se nas mesmas imagens pareadas (baseline e 7 dias após a intervenção) utilizadas na análise quantitativa, registrando na escala de percepção visual (VAS), os valores de ”1” (Nenhuma melhora na aparência ou lesão não removida totalmente), à “7” (Melhora excepcional da estética, ou lesão totalmente removida). Aos pacientes e/ou os pais foi solicitado que informassem o seu grau de satisfação. Para esse efeito, foi aplicada a mesma escala VAS, variando de insatisfeito até excepcionalmente satisfeito. Os dados da análise quantitativa foram submetidos à análise estatística pelo “Teste “t” de Student” e os da análise qualitativa e do “Grau de satisfação” pelo “Teste Exato de Fisher” (α = 0,05). Resultados: Não foi observada diferença significativa entre os grupos quando as medidas objetivas foram levadas em consideração (valores de ΔL, Δa, Δb e ΔE) (p> 0,49). Em relação à avaliação qualitativa, os pacientes estavam completamente satisfeitos em 88% e 100% dos casos, respectivamente, para as técnicas de microabrasão e infiltração resinosa (p=0,42). No entanto, os examinadores observaram que a infiltração resinosa mudou completamente a aparência estética dos dentes em 70% dos casos, enquanto que isso ocorreu em apenas 10% dos casos quando a microabrasão foi aplicada (p= 0,02). Conclusão: As técnicas de microabrasão e de infiltração resinosa foram capazes de remover/mascarar manchas de fluorose e promoveram um alto nível de satisfação para os pacientes, diante de uma maior preservação de estrutura dental na técnica da infiltração resinosa, ambas as técnicas tiveram melhoria na estética obtida, ainda que diferenças positivas foram observadas em favor da infiltração resinosa. / This study evaluated the masking capability of fluorosis stains using the microabrasion technique in comparison to the resin infiltration technique. Method: Twenty patients, from 12 to 16 years old, presenting fluorosis stains on dental enamel were randomly divided into two groups (n = 10): microabrasion and resin infiltration. Both techniques were performed according to the manufacturer's guidelines. The evaluation occurred in three different ways: quantitative, qualitative and "Degree of patient/responsible satisfaction". Standardized photographs were taken (baseline and 1 week after the intervention), to be analyzed using Adobe Photoshop CS5 software, to obtain the data for calculating the values of ΔL, Δa, Δb and ΔE at the points where the spot of fluorosis was more intense in each of the treated teeth. To evaluate the aesthetic optimization, by qualitative/satisfaction degree, obtained in the fluorotic stains, two blind and calibrated evaluators were based on the same paired images (baseline and 7 days after the intervention) used in the quantitative analysis, recording in a visual perception scale (VAS) values between "1" (No improvement in appearance or injury not completely removed), to "7" (Exceptional aesthetic improvement, or stain totally removed); patients and/or parents were asked to indicate their satisfaction degree, in the same VAS scale used by the evaluators, who ranged from “1” (totally dissatisfied) to “7” (exceptionally satisfied). The data of the quantitative analysis were submitted to statistical analysis by Student's “t” Test and those of the qualitative analysis Fisher's Exact Test (α = 0.05). Results: There was no significant difference between groups when the objective measurements were considered (values ΔL, Δa, and Δb ΔE) (p> 0.49). Regarding qualitative evaluation, patients were completely satisfied by 88% and 100% of the cases, respectively, to techniques and microabrasion resin infiltration (p = 0.42). However, investigators found that the resin infiltration completely changed the aesthetic appearance of teeth in 70% of cases, while it occurred in only 10% of cases when the microabrasion was applied (p = 0.02). Conclusion: The both techniques (microabrasion and resin infiltration) were able to remove/mask fluorosis stains and promoted a high level of patient satisfaction, due to a greater dental structure preservation in the resin infiltration technique, both techniques obtained aesthetics results although positive differences were observed in favor of resin infiltration.
2

Influência da natureza e topografia da superfície na micro-abrasão e micro-abrasão-corrosão / Influence of nature and surface topography on micro-abrasion and micro-abrasion-corrosion

Ardila, Miguel Angel Narvaez 06 September 2017 (has links)
CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / O trabalho tem como objetivo contribuir ao entendimento do efeito das caraterísticas superficiais no desgaste abrasivo com e sem efeito corrosivo. Utilizou-se o equipamento de micro-abrasão-corrosão desenvolvido no Laboratório de Tribologia e Materiais (LTM). Foi utilizado nos testes: amostras de aço inoxidável austenítico AISI 304, partículas abrasivas de sílica e velocidade de rotação de 150 rpm. Para a parte corrosiva foi usada solução eletrolítica com 1N de H2SO4. Para a influência da topografia de superfície do corpo de prova o aço AISI 304 foi preparado em lixas de carbeto de silício de granulometria #80 e #4000, e com disposições de lixamento perpendicular e paralelo com respeito ao sentido de rotação da esfera. Esferas de zircônia (Ø 25,4 mm) foram usadas como contra-corpos. Para avaliar a influência da natureza e evolução topográfica da superfície do contra-corpo usaram-se cinco contra-corpos esféricos (Ø 25,4 mm): um cerâmico (nitreto de silício, Si3N4), um metálico (aço AISI 52100) e três polímeros termoplásticos (polipropileno, PP, poliacetal, POM, e poliamida 6,6, PA 6,6); para os testes de micro-abrasão-corrosão foram usados um cerâmico (Si3N4) e um polímero termoplástico (PP). Foi acompanhada a evolução topográfica ao longo dos testes nos contra-corpos por meio de interferometria e perfilometría. O deslizamento das partículas abrasivas foi predominante nas calotas geradas em todos os testes realizados. A topografia de superfície do corpo e contra-corpo mostrou ter relação com a taxa de desgaste na micro-abrasão e micro-abrasão-corrosão. Topografia de superfície com parâmetros de rugosidade maiores apresentam maiores taxas de desgaste, tendo maior sensibilidade na micro-abrasão-corrosão. Atribuiu-se que, com maiores valores dos parâmetros de rugosidade, consegue-se maior efetividade no arraste e participação de partículas abrasivas no contato. / The aim of this work is to contribute to the understanding of the effect of surface characteristics on abrasive wear with and without corrosive effect. The micro-abrasion-corrosion apparatus developed at the Tribology and Materials Laboratory (LTM) was used. The following tests were used: AISI 304 austenitic stainless steel test specimens (body), silica abrasive particles and rotational speed of 150 rpm. For the corrosive analysis, an 1N H2SO4 electrolytic solution was used. For the influence of the surface topography of the specimen, the AISI 304 steel was grinded using silicon carbide (SiC) (#80 and # 4000), and tested with perpendicular and parallel arrangements with respect to the direction of rotation of the sphere. Zirconia balls (Ø 25.4 mm) were used as counter bodies. In order to analyze the influence of the nature and topographic evolution of the counter-body surface, five spherical counter bodies (Ø 25.4 mm) were used in the micro-abrasion tests: one ceramic (silicon nitride, Si3N4), one metal (AISI steel 52100) and three thermoplastic polymers (polypropylene, PP, polyacetal, POM and polyamide 6.6, PA 6.6); For the micro-abrasion-corrosion tests one ceramic (silicon nitride) and one thermoplastic polymer (PP) were used. The topographic evolution of the counter bodies was monitored along the tests through interferometry and profilometry. The grooving of the abrasive particles was predominant in the wear scars generated in all tests performed. The surface topographies of the body and counter-body showed to have relation with the wear rate in the micro-abrasion and micro-abrasion-corrosion tests. Higher roughness parameters induced higher wear rates, and show greater sensitivity in micro-abrasion-corrosion. It was attributed that higher values of the roughness parameters achieved greater effectiveness in the drag and participation of abrasive particles in the contact. / Tese (Doutorado)

Page generated in 0.05 seconds