• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da microdureza e rugosidade do esmalte bovino submetido ao clareamento com géis de alta e baixa concentração com ou sem adição de cálcio na sua composição / Evaluation of microhardness and roughness of bovine enamel after bleaching at low and high concentration with or without calcium

Kandice Valente Martins 29 April 2015 (has links)
Avaliar a microdureza e rugosidade de superfície do esmalte bovino antes e após clareamento com agentes de baixa e alta concentração, ambos com ou sem adição de cálcio. Método: Foram utilizados sessenta fragmentos dentais bovinos, aleatoriamente divididos em cinco grupos (n=12), de acordo com o agente clareador utilizado. As amostras foram clareadas utilizando-se peróxido de carbamida 20% (PC 20%) ou peróxido de hidrogênio 40% (PH 40%), ambos com ou sem adição de cálcio (2000ppm) na sua formulação, e o tempo de aplicação foi de acordo com as instruções do fabricante. Em seguida, as amostras foram lavadas e armazenadas em saliva artificial até a próxima sessão de clareamento. Os tratamentos foram realizados por 14 dias (quatorze dias). A análise da superfície do esmalte foi realizada com os testes de Rugosidade superficial (`cutoff 0,25mm) e Microdureza Knoop (50g/15s), antes e após os tratamentos. Foi realizada uma análise exploratória dos dados e os grupos foram submetidos à análise de variância (ANOVA) e teste de Tukey (significância de 5%). Resultados: Após o clareamento o grupo clareado com PH 40% apresentou valores mais baixos de microdureza mas sem diferença significativa para o PC 20% e PH 40% com cálcio. Houve diferença estatística significativa entre as leituras iniciais e finais. Para rugosidade superficial não foram observadas diferenças entre os materiais testados; porém houve aumento da rugosidade para todos os grupos após o clareamento, exceto para o grupo controle. Conclusão: Concluiu-se que houve diminuição da microdureza para todos os agentes clareadores testados. Houve um aumento da rugosidade superficial logo após o clareamento dental. / Objective: To evaluate the effects of bleaching with hydrogen peroxide 40% (HP 40%) and carbamide peroxide 20% (CP 20%), with and without the addition of calcium (2000ppm), in enamel through the Knoop microhardness and roughness tests. Method: bovine enamel blocks (3mm2) were prepared and included and randomly divided into five experimental groups (n=12) and subjected to different treatments. The Group 1 and 2 were bleached carbamide peroxide with or without calcium, and G3 e G4 were bleached HP 40% with or without calcium. The group 5 were immersed in saliva artificial (control group). The samples were washed and stored in artificial saliva to the next bleaching session. The treatments were carried out for 14 days. The analysis of the enamel surface was performed with test surface roughness and Microhardness, before and after treatment. An exploratory analysis of the data and the groups were subjected to analysis of variance was performed (ANOVA) and Tukey test (5% significance). Results: All specimens were subjected to testing Knoop microhardness before the treatment (initial reading), after the bleaching treatment. The bleached group with 40% PH had the lowest values of microhardness. There was a statistically significant difference between the initial and final readings. For surface roughness were no differences between the tested materials; but there was an increase of roughness for all groups after bleaching. Conclusion: It was concluded that there was decrease of microhardness for all tested bleaching agents. There was an increase in surface roughness after tooth whitening.
2

Avaliação da resistência à abrasão, microdureza superficial e estabilidade de cor de dentes artificiais de resina acrílica / Evaluation of the abrasion resistance, superficial microhardness and color stability of acrylic resin artificial teeth.

Pâmela Carbone Mello 20 December 2007 (has links)
O objetivo deste trabalho foi avaliar in vitro a resistência a abrasão, a microdureza superficial e a estabilidade de cor de dentes artificiais de resina acrílica. Sete grupos (1- Biolux, 2- Trilux, 3- Blue Dent, 4- Biocler, 5- Orthosit-Vivodent, 6- Postaris-Antaris, 7- Gnathostar-Ivostar), compostos de 12 pre-molares superiores de cada fabricante, sendo 6 contra antagonistas metálicos (Ni-Cr) e 6 contra antagonistas de resina indireta (Solidex), foram delineados em um perfilômetro, antes e após serem submetidos ao ensaio de abrasão. A diferença linear entre a primeira e a segunda leitura foi medida com um paquímetro digital (precisao 0,01mm). Após a análise estatística (análise de variância, teste de Tukey-Kramer, nível de significancia em p<0,05), observou-se que houve diferenças estatísticas significantes entre os grupos e que a marca Postaris apresentou os menores valores de desgaste contra ambos os antagonistas (R=2,33±0,91&micro;m e M=1,78±0,42&micro;m). Para a análise da microdureza superficial Vickers, foram utilizados 6 incisivos laterais superiores de cada marca e 3 leituras (terços incisal, médio e cervical) foram feitas com o auxílio de um microdurômetro. As médias de microdureza superficial Vickers foram submetidas a análise estatística (nível de significancia p<0,05) e com os resultados obtidos concluiu-se que o grupo Biolux (22,1±0,91VHN) seguido do Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) e Biocler (21,0±1,80VHN) apresentaram maiores valores de dureza diferenciando-se do Vivodent (19,1±0,99VHN) e Blue Dent (18,9±1,54VHN), menos duros. Para o ensaio de estabilidade de cor foram utilizados 6 incisivos centrais superiores direitos de cada marca comercial (n=42), submetidos ao processo de envelhecimento artificial acelerado. O aparelho de leitura de cor utilizado foi um Espectrocolorímetro Portátil Modelo Color Guide 45/0 (BYK-Gardner, Alemanha). Cada dente teve sua cor lida antes e imediatamente após o ensaio de envelhecimento artificial. Os valores de &Delta;E foram submetidos a análise estatística com auxílio do programa JMP 5.1 (SAS Institute, EUA) e mostraram que houve diferenças estatisticamente significantes entres os grupos e que apenas a marca Blue Dent (4,37±0,32) apresentou valores de &Delta;E>3,3 considerado, segunda a literatura, clinicamente inaceitável. Para os grupos que tiveram alterações clinicamente aceitáveis, o grupo Antaris/Postaris teve a maior variação de cor (&Delta;E=2,73±0,96) e o grupo Biolux apresentou a menor variação de cor (1,39±0,27). Dentro das limitações da metodologia empregada, concluiu-se que o antagonista utilizado (metal ou resina) influencia a escolha do dente artificial, e que os dentes artificiais testados tem comportamentos diferentes quanto a resistência a abrasão, microdureza superficial e estabilidade de cor. / The objective of this work was to evaluate in vitro the abrasion resistance, the superficial microhardness and the color stability of acrylic resin artificial teeth. Seven groups (1-Biolux, 2 - Trilux, 3 - Blue Dent, 4 - Biocler, 5 - Orthosit-Vivodent, 6 - Postaris-Antaris, 7 - Gnathostar-Ivostar), composed of 12 upper premolar for each manufacturer\'s, being 6 against metallic antagonists (Ni-Cr) and 6 against indirect resin (Solidex) antagonists, were delineated in a perfilometer, before and after the abrasion test. The linear difference between the first and the second readings was measured with a digital calliper (0,01mm precision). After the statistical analysis (variance analysis, Tukey-Kramer\'s test, p<0.05), it was observed that there were significant differences among the groups and that the trademark Postaris presented the smallest wear values against both antagonists (R=2,33±0,91&micro;m and M=1,78±0,42&micro;m). For Vickers superficial microhardness, 6 lateral upper incisors of each mark and 3 readings were used (incisal, medium, and cervical thirds) done with the microdurometer. The averages of Vickers superficial microhardness were submitted to the statistical analysis (p<0.05) and the obtained results show that the group Biolux (22,1±0,91VHN) followed by Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) and Biocler (21,0±1,80VHN) presented higher values, differing from Vivodent (19,1±0,99VHN) and Blue Dent (18,9±1,54VHN), less harders. For the color stability test 6 upper right central incisors of each commercial mark were used (n=42), submitted to the accelerated artificial aging process. The apparel for color reading was a Portable Spectruncolorimeter Model Color Guide 45/0 (BYK-Gardner, Germany). Each tooth had his color read before and immediately after the artificial aging. The &Delta;E values were submitted to the statistical analysis with JMP 5.1 (HEALTHY Institute, USA) software and show that significant differences were found among the groups and that only Blue Dent (4,37±0,32) presented clinically unacceptable values of &Delta;E (&Delta;E>3.3). For the groups that had clinically acceptable color alterations, the Antaris/Postaris group had the largest color variation (&Delta;E=2.73±0.96) and the Biolux group presented to smallest color variation (&Delta;E=1.39±0.27). Within the limitations of the methodology, was concluded that the antagonist (metal or resin) influence the choice of the artificial tooth, and that the tested artificial teeth have different behaviors for the abrasion resistance, superficial microhardness and color stability.
3

Avaliação da resistência à abrasão, microdureza superficial e estabilidade de cor de dentes artificiais de resina acrílica / Evaluation of the abrasion resistance, superficial microhardness and color stability of acrylic resin artificial teeth.

Mello, Pâmela Carbone 20 December 2007 (has links)
O objetivo deste trabalho foi avaliar in vitro a resistência a abrasão, a microdureza superficial e a estabilidade de cor de dentes artificiais de resina acrílica. Sete grupos (1- Biolux, 2- Trilux, 3- Blue Dent, 4- Biocler, 5- Orthosit-Vivodent, 6- Postaris-Antaris, 7- Gnathostar-Ivostar), compostos de 12 pre-molares superiores de cada fabricante, sendo 6 contra antagonistas metálicos (Ni-Cr) e 6 contra antagonistas de resina indireta (Solidex), foram delineados em um perfilômetro, antes e após serem submetidos ao ensaio de abrasão. A diferença linear entre a primeira e a segunda leitura foi medida com um paquímetro digital (precisao 0,01mm). Após a análise estatística (análise de variância, teste de Tukey-Kramer, nível de significancia em p<0,05), observou-se que houve diferenças estatísticas significantes entre os grupos e que a marca Postaris apresentou os menores valores de desgaste contra ambos os antagonistas (R=2,33±0,91&micro;m e M=1,78±0,42&micro;m). Para a análise da microdureza superficial Vickers, foram utilizados 6 incisivos laterais superiores de cada marca e 3 leituras (terços incisal, médio e cervical) foram feitas com o auxílio de um microdurômetro. As médias de microdureza superficial Vickers foram submetidas a análise estatística (nível de significancia p<0,05) e com os resultados obtidos concluiu-se que o grupo Biolux (22,1±0,91VHN) seguido do Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) e Biocler (21,0±1,80VHN) apresentaram maiores valores de dureza diferenciando-se do Vivodent (19,1±0,99VHN) e Blue Dent (18,9±1,54VHN), menos duros. Para o ensaio de estabilidade de cor foram utilizados 6 incisivos centrais superiores direitos de cada marca comercial (n=42), submetidos ao processo de envelhecimento artificial acelerado. O aparelho de leitura de cor utilizado foi um Espectrocolorímetro Portátil Modelo Color Guide 45/0 (BYK-Gardner, Alemanha). Cada dente teve sua cor lida antes e imediatamente após o ensaio de envelhecimento artificial. Os valores de &Delta;E foram submetidos a análise estatística com auxílio do programa JMP 5.1 (SAS Institute, EUA) e mostraram que houve diferenças estatisticamente significantes entres os grupos e que apenas a marca Blue Dent (4,37±0,32) apresentou valores de &Delta;E>3,3 considerado, segunda a literatura, clinicamente inaceitável. Para os grupos que tiveram alterações clinicamente aceitáveis, o grupo Antaris/Postaris teve a maior variação de cor (&Delta;E=2,73±0,96) e o grupo Biolux apresentou a menor variação de cor (1,39±0,27). Dentro das limitações da metodologia empregada, concluiu-se que o antagonista utilizado (metal ou resina) influencia a escolha do dente artificial, e que os dentes artificiais testados tem comportamentos diferentes quanto a resistência a abrasão, microdureza superficial e estabilidade de cor. / The objective of this work was to evaluate in vitro the abrasion resistance, the superficial microhardness and the color stability of acrylic resin artificial teeth. Seven groups (1-Biolux, 2 - Trilux, 3 - Blue Dent, 4 - Biocler, 5 - Orthosit-Vivodent, 6 - Postaris-Antaris, 7 - Gnathostar-Ivostar), composed of 12 upper premolar for each manufacturer\'s, being 6 against metallic antagonists (Ni-Cr) and 6 against indirect resin (Solidex) antagonists, were delineated in a perfilometer, before and after the abrasion test. The linear difference between the first and the second readings was measured with a digital calliper (0,01mm precision). After the statistical analysis (variance analysis, Tukey-Kramer\'s test, p<0.05), it was observed that there were significant differences among the groups and that the trademark Postaris presented the smallest wear values against both antagonists (R=2,33±0,91&micro;m and M=1,78±0,42&micro;m). For Vickers superficial microhardness, 6 lateral upper incisors of each mark and 3 readings were used (incisal, medium, and cervical thirds) done with the microdurometer. The averages of Vickers superficial microhardness were submitted to the statistical analysis (p<0.05) and the obtained results show that the group Biolux (22,1±0,91VHN) followed by Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) and Biocler (21,0±1,80VHN) presented higher values, differing from Vivodent (19,1±0,99VHN) and Blue Dent (18,9±1,54VHN), less harders. For the color stability test 6 upper right central incisors of each commercial mark were used (n=42), submitted to the accelerated artificial aging process. The apparel for color reading was a Portable Spectruncolorimeter Model Color Guide 45/0 (BYK-Gardner, Germany). Each tooth had his color read before and immediately after the artificial aging. The &Delta;E values were submitted to the statistical analysis with JMP 5.1 (HEALTHY Institute, USA) software and show that significant differences were found among the groups and that only Blue Dent (4,37±0,32) presented clinically unacceptable values of &Delta;E (&Delta;E>3.3). For the groups that had clinically acceptable color alterations, the Antaris/Postaris group had the largest color variation (&Delta;E=2.73±0.96) and the Biolux group presented to smallest color variation (&Delta;E=1.39±0.27). Within the limitations of the methodology, was concluded that the antagonist (metal or resin) influence the choice of the artificial tooth, and that the tested artificial teeth have different behaviors for the abrasion resistance, superficial microhardness and color stability.
4

A ação de sucos de frutas sobre materiais restauradores utilizados em lesões cervicais não cariosas / The action of fruit juices upon restorative materials used in noncarious cervical lesions

Cruz, Andréa Ferreira Santos da 07 November 2013 (has links)
O presente estudo in vitro analisou o efeito de 3 sucos de fruta com baixo pH (suco de cupuaçu, taperebá e laranja), e saliva artificial (controle) sobre materiais restauradores indicados em lesões cervicais não cariosas: resina composta nanoparticulada (Filtek Z350 XT), cimento de ionômero de vidro resino modificado (Vitremer) e um cimento de ionômero de vidro convencional (Fuji II). Os materiais foram avaliados, quantitativamente, quanto à alteração de: peso, rugosidade superficial e microdureza superficial, e qualitativamente, por microscopia eletrônica de varredura (MEV). Foram confeccionados 144 corpos de prova para cada teste quantitativo (n=12) e 45 para o MEV (n=3), de (8mm de diâmetro x 2mm de altura). Os corpos de prova foram preparados, mantidos em saliva artificial por 24 h à 37º C, receberam acabamento em politriz, e em seguida foram realizadas as leituras iniciais. Durante um período de 10 dias consecutivos, os corpos de prova foram submetidos ao desafio erosivo (nos respectivos sucos de frutas) durante 30 minutos três vezes ao dia, totalizando 90 minutos/dia e mantidos em saliva artificial entre os intervalos. Após o período de ciclagem erosiva, foram realizadas as leituras finais. Os resultados obtidos foram submetidos ao teste t, ANOVA e Tukey. As médias de alteração entre os valores de peso finais e iniciais demonstraram diferença significativa (p<0,01) nos materiais estudados e em todos os sucos estudados, com exceção do Vitremer quando imerso no suco de taperebá (p>0,01). As médias de alteração entre os valores de rugosidade superficial final e inicial demonstraram diferença significativa (p<0,01) para todos os materiais estudados em todos os sucos, exceto a Filtek Z350 XT no grupo controle que não apresentou diferença significativa (p>0,01). A comparação entre os valores de microdureza final e inicial demonstrou diferença significativa (p<0,01) na microdureza dos materiais estudados em todos os meios de imersão, inclusive no grupo controle. De um modo geral o suco de taperebá foi o que provocou a maior alteração na superfície dos materiais restauradores quanto ao peso, rugosidade, microdureza e na microscopia eletrônica de varredura. A resina composta Filtek Z350 XT foi o material restaurador que menos sofreu alterações de superfície. Concluiu-se que os sucos das frutas estudados são capazes de alterar os materiais restauradores, sendo que a resina composta foi o material que sofreu menor alteração. / This in vitro study examined the effects of 3 fruit juices with low pH (cupuaçu, taperebá and orange) and artificial saliva (control) upon restorative materials indicated in noncarious cervical lesions: nanoparticle composite resin (Filtek Z350 XT), resin-modified glass ionomer cement (Vitremer) and a glass ionomer cement (Fuji II). The materials were evaluated quantitatively as for alterations in weight, surface roughness and surface microhardness, and qualitatively by scanning electronic microscopy (SEM). 144 specimens were prepared for each quantitative test (n = 12) and 45 for the SEM (n = 3), of (8mm diameter x 2mm height). The specimens were prepared, stored in artificial saliva for 24 hours at 37º C, were finished in a polishing machine, and then the initial readings were performed. During a period of 10 consecutive days, the specimens were subjected to erosive challenge (in the respective juices) for 30 minutes, three times a day, and totaling 90 minutes/day and kept in artificial saliva between intervals. After the erosive cycling period, the final readings were taken. The data were analyzed using t test, ANOVA and Tukey.Test The average alterations between the values of initial and final weight showed significant difference (p < 0.01) in the material studied and all the juices studied, except for Vitremer when immersed in taperebá juice (p > 0.01). The average alterations between the values of initial and final surface roughness showed a significant difference (p < 0.01) for all materials studied in all juices, except for Filtek Z350 XT, in the control group, that showed no significant differences (p > 0.01). The comparison between the values of initial and final microhardness showed a significant difference (p < 0.01) in microhardness of the materials studied in all immersion means, including the control group. In general, taperebá juice was the one that caused the biggest alterations in the surface of restorative materials with respect to weight, roughness, hardness and scanning electronic microscopy. The composite resin Filtek Z350 XT was the restorative material that suffered less surface alterations. It was concluded that the fruit juices studied are capable of altering the restorative materials, and composite resin was the material that has undergone minor changes.
5

A ação de sucos de frutas sobre materiais restauradores utilizados em lesões cervicais não cariosas / The action of fruit juices upon restorative materials used in noncarious cervical lesions

Andréa Ferreira Santos da Cruz 07 November 2013 (has links)
O presente estudo in vitro analisou o efeito de 3 sucos de fruta com baixo pH (suco de cupuaçu, taperebá e laranja), e saliva artificial (controle) sobre materiais restauradores indicados em lesões cervicais não cariosas: resina composta nanoparticulada (Filtek Z350 XT), cimento de ionômero de vidro resino modificado (Vitremer) e um cimento de ionômero de vidro convencional (Fuji II). Os materiais foram avaliados, quantitativamente, quanto à alteração de: peso, rugosidade superficial e microdureza superficial, e qualitativamente, por microscopia eletrônica de varredura (MEV). Foram confeccionados 144 corpos de prova para cada teste quantitativo (n=12) e 45 para o MEV (n=3), de (8mm de diâmetro x 2mm de altura). Os corpos de prova foram preparados, mantidos em saliva artificial por 24 h à 37º C, receberam acabamento em politriz, e em seguida foram realizadas as leituras iniciais. Durante um período de 10 dias consecutivos, os corpos de prova foram submetidos ao desafio erosivo (nos respectivos sucos de frutas) durante 30 minutos três vezes ao dia, totalizando 90 minutos/dia e mantidos em saliva artificial entre os intervalos. Após o período de ciclagem erosiva, foram realizadas as leituras finais. Os resultados obtidos foram submetidos ao teste t, ANOVA e Tukey. As médias de alteração entre os valores de peso finais e iniciais demonstraram diferença significativa (p<0,01) nos materiais estudados e em todos os sucos estudados, com exceção do Vitremer quando imerso no suco de taperebá (p>0,01). As médias de alteração entre os valores de rugosidade superficial final e inicial demonstraram diferença significativa (p<0,01) para todos os materiais estudados em todos os sucos, exceto a Filtek Z350 XT no grupo controle que não apresentou diferença significativa (p>0,01). A comparação entre os valores de microdureza final e inicial demonstrou diferença significativa (p<0,01) na microdureza dos materiais estudados em todos os meios de imersão, inclusive no grupo controle. De um modo geral o suco de taperebá foi o que provocou a maior alteração na superfície dos materiais restauradores quanto ao peso, rugosidade, microdureza e na microscopia eletrônica de varredura. A resina composta Filtek Z350 XT foi o material restaurador que menos sofreu alterações de superfície. Concluiu-se que os sucos das frutas estudados são capazes de alterar os materiais restauradores, sendo que a resina composta foi o material que sofreu menor alteração. / This in vitro study examined the effects of 3 fruit juices with low pH (cupuaçu, taperebá and orange) and artificial saliva (control) upon restorative materials indicated in noncarious cervical lesions: nanoparticle composite resin (Filtek Z350 XT), resin-modified glass ionomer cement (Vitremer) and a glass ionomer cement (Fuji II). The materials were evaluated quantitatively as for alterations in weight, surface roughness and surface microhardness, and qualitatively by scanning electronic microscopy (SEM). 144 specimens were prepared for each quantitative test (n = 12) and 45 for the SEM (n = 3), of (8mm diameter x 2mm height). The specimens were prepared, stored in artificial saliva for 24 hours at 37º C, were finished in a polishing machine, and then the initial readings were performed. During a period of 10 consecutive days, the specimens were subjected to erosive challenge (in the respective juices) for 30 minutes, three times a day, and totaling 90 minutes/day and kept in artificial saliva between intervals. After the erosive cycling period, the final readings were taken. The data were analyzed using t test, ANOVA and Tukey.Test The average alterations between the values of initial and final weight showed significant difference (p < 0.01) in the material studied and all the juices studied, except for Vitremer when immersed in taperebá juice (p > 0.01). The average alterations between the values of initial and final surface roughness showed a significant difference (p < 0.01) for all materials studied in all juices, except for Filtek Z350 XT, in the control group, that showed no significant differences (p > 0.01). The comparison between the values of initial and final microhardness showed a significant difference (p < 0.01) in microhardness of the materials studied in all immersion means, including the control group. In general, taperebá juice was the one that caused the biggest alterations in the surface of restorative materials with respect to weight, roughness, hardness and scanning electronic microscopy. The composite resin Filtek Z350 XT was the restorative material that suffered less surface alterations. It was concluded that the fruit juices studied are capable of altering the restorative materials, and composite resin was the material that has undergone minor changes.

Page generated in 0.0857 seconds