• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito do tamanho do abrasivo no desgaste de metais. / The effect of abrasive size on the wear resistance of metallic materials.

Coronado Marin, John Jairo 08 June 2010 (has links)
Neste trabalho, foi investigado o efeito do tamanho do abrasivo na resistência ao desgaste de cinco ligas metálicas. Foi usado, para este estudo, o equipamento pino contra lixa e alumina como abrasivo, com tamanho médio entre 16 µm e 192 µm. A microestrutura das ligas metálicas foi caracterizada com microscopia ótica e os mecanismos de desgaste abrasivo e os microcavacos (partículas de desgaste) foram caracterizados usando microscopia eletrônica de varredura (MEV). Em uma primeira série de experimentos, foi usado ferro fundido mesclado com carbonetos M3C (temperado e revenido a temperaturas entre 300 e 600°C). Para abrasivos pequenos, a perda de massa elevou-se com o aumento do tamanho do abrasivo. Entretanto, para abrasivos grandes, a perda de massa aumenta com inclinação menor e o mecanismo prevalente de desgaste é o microcorte. Para abrasivos maiores, o mecanismo prevalente de desgaste é microsulcamento. Em uma segunda série de experimentos, foi usado ferro fundido branco (FFB), com matrizes austenítica e martensítica. O FFB com matriz austenítica apresentou um tamanho crítico de abrasivo (TCA) de 36 µm e, para o ferro fundido martensítico, foi aproximadamente de 116 µm. A perda de massa do ferro fundido com matriz austenítica aumentou linearmente com o aumento do tamanho dos abrasivos, após o TCA a perda de massa aumenta com inclinação menor. O FFB martensítico, com menores tamanhos do abrasivo, apresentou um comportamento linear. Existe, porém, uma região de transição não-linear e achatada, quando o tamanho de partícula crítico é atingido, tornando-se independente do tamanho do abrasivo. Antes do TCA, o micromecanismo prevalente de desgaste foi microcorte e a lixa apresentou cavacos contínuos e finos e, após o TCA, o mecanismo prevalente de desgaste foi microsulcamento e apresentou cavacos descontínuos e deformados. O efeito do tamanho de abrasivo observado na perda de massa foi apresentado na energia especifica de corte e no coeficiente de atrito. Em uma terceira série de experimentos, foi usado alumínio e aço AISI 1045. O alumínio (estrutura cristalina cúbica de fase centrada) apresentou um comportamento similar ao observado no FFB com matriz austenítica, e o aço AISI 1045 apresentou um comportamento similar ao FFB com matriz martensítica. Verificou-se que, no alumínio e no aço AISI 1045, também se apresenta mudança na morfologia dos cavacos e nos micromecanismos de desgaste, observados nos materiais com segunda fase dura. Em uma quarta série de experimentos, foi usado o ferro fundido cinzento para corroborar a mudança dos micromecanismos de desgaste abrasivo e dos microcavacos com o TCA. O ferro fundido cinzento não apresentou uma transição (TCA) na curva de tamanho de abrasivo contra perda de massa. A morfologia dos cavacos foi similar para os diferentes tamanhos de abrasivos (descontínua). Para abrasivos menores, porém, apresentaram-se alguns cavacos contínuos e finos. O micromecanismo prevalente de desgaste abrasivo foi de microcorte para os diferentes abrasivos usados. Portanto, nesta pesquisa, foi demonstrado que o tamanho crítico de abrasivo está relacionado com os micromecanismos de desgaste e com a morfologia dos microcavacos. / In this research, the effect of abrasive size on the wear resistance of five metallic materials was investigated. Abrasive wear tests using a pin test on alumina paper were carried out using abrasive sizes between 16 µm and 192 µm. The wear surface of the specimens was examined by scanning electron microscopy for identifying the wear micromechanism and the type of microchips formed on the abrasive paper (wear debris). In a first series of experiments mottled cast iron samples with M 3 C carbides were tested. The samples were quenched and tempered in temperatures ranging from 300°C to 600°C. For small abrasive particles, the wear mass loss increased linearly with the increase of particle size. However, for higher abrasive sizes the wear mass loss increased much more slowly. For lower abrasive sizes the main wear mechanism was microcutting. For higher abrasive sizes, the main wear mechanism was microploughing. In a second series of experiments white cast iron with M 3 C carbide with austenitic and martensitic matrix were tested. The results show that the mass loss for cast irons with austenitic and martensitic matrices increases linearly with the increase of particle size until the critical particle size is reached. The cast iron with austenitic matrix presented a critical abrasive size of 36 µm and for the martensitic cast iron, the critical particle size was about 116 µm. After the critical particle size is reached, the rate of mass loss of the cast iron with austenitic matrix diminishes to a lower linear rate, and for cast irons with martensitic matrix the curve of mass loss is non-linear and flattens when the critical particle size is reached. It becomes, then, constant, independent of additional size increases. The abrasive paper in contact with the iron of both austenitic and martensitic matrices presents fine continuous microchips and the main wear mechanism was microcutting before reaching critical particle size, and after that it presents deformed discontinuous microchips and the main wear mechanism was microploughing. This behavior of change in rates after reaching a critical size happened not only for mass loss versus abrasive size, but it was also observed both in curves of friction coefficient and specific cutting energy versus abrasive size. In a third series of experiments aluminum and AISI 1045 steel were tested. The first (FCC structure) showed similar behavior to that observed in the white cast iron with austenitic matrix and the latter showed similar behavior to that observed in white cast iron with martensitic matrix. Both aluminum and AISI 1045 steel show similar changes in the microchips morphology and in the wear micromechanisms, something that had been observed before in materials with hard second phase. In a fourth series of experiments gray cast iron was tested in order to demonstrate the relationship between the abrasive wear micromechanisms and the type of microchips, before and after achieving critical abrasive size. The grey cast iron did not show a transition in the curve of abrasive size against mass loss. The morphology of the chips was similar for the different sizes of abrasive (discontinuous). However, smaller abrasive sizes some thin continuous microchips were formed. The main abrasive wear micromechanism was microcutting for the different abrasives sizes tested. Therefore, it was shown that the critical abrasive size is related to the wear micromechanisms and the microchips morphology.
2

Efeito do tamanho do abrasivo no desgaste de metais. / The effect of abrasive size on the wear resistance of metallic materials.

John Jairo Coronado Marin 08 June 2010 (has links)
Neste trabalho, foi investigado o efeito do tamanho do abrasivo na resistência ao desgaste de cinco ligas metálicas. Foi usado, para este estudo, o equipamento pino contra lixa e alumina como abrasivo, com tamanho médio entre 16 µm e 192 µm. A microestrutura das ligas metálicas foi caracterizada com microscopia ótica e os mecanismos de desgaste abrasivo e os microcavacos (partículas de desgaste) foram caracterizados usando microscopia eletrônica de varredura (MEV). Em uma primeira série de experimentos, foi usado ferro fundido mesclado com carbonetos M3C (temperado e revenido a temperaturas entre 300 e 600°C). Para abrasivos pequenos, a perda de massa elevou-se com o aumento do tamanho do abrasivo. Entretanto, para abrasivos grandes, a perda de massa aumenta com inclinação menor e o mecanismo prevalente de desgaste é o microcorte. Para abrasivos maiores, o mecanismo prevalente de desgaste é microsulcamento. Em uma segunda série de experimentos, foi usado ferro fundido branco (FFB), com matrizes austenítica e martensítica. O FFB com matriz austenítica apresentou um tamanho crítico de abrasivo (TCA) de 36 µm e, para o ferro fundido martensítico, foi aproximadamente de 116 µm. A perda de massa do ferro fundido com matriz austenítica aumentou linearmente com o aumento do tamanho dos abrasivos, após o TCA a perda de massa aumenta com inclinação menor. O FFB martensítico, com menores tamanhos do abrasivo, apresentou um comportamento linear. Existe, porém, uma região de transição não-linear e achatada, quando o tamanho de partícula crítico é atingido, tornando-se independente do tamanho do abrasivo. Antes do TCA, o micromecanismo prevalente de desgaste foi microcorte e a lixa apresentou cavacos contínuos e finos e, após o TCA, o mecanismo prevalente de desgaste foi microsulcamento e apresentou cavacos descontínuos e deformados. O efeito do tamanho de abrasivo observado na perda de massa foi apresentado na energia especifica de corte e no coeficiente de atrito. Em uma terceira série de experimentos, foi usado alumínio e aço AISI 1045. O alumínio (estrutura cristalina cúbica de fase centrada) apresentou um comportamento similar ao observado no FFB com matriz austenítica, e o aço AISI 1045 apresentou um comportamento similar ao FFB com matriz martensítica. Verificou-se que, no alumínio e no aço AISI 1045, também se apresenta mudança na morfologia dos cavacos e nos micromecanismos de desgaste, observados nos materiais com segunda fase dura. Em uma quarta série de experimentos, foi usado o ferro fundido cinzento para corroborar a mudança dos micromecanismos de desgaste abrasivo e dos microcavacos com o TCA. O ferro fundido cinzento não apresentou uma transição (TCA) na curva de tamanho de abrasivo contra perda de massa. A morfologia dos cavacos foi similar para os diferentes tamanhos de abrasivos (descontínua). Para abrasivos menores, porém, apresentaram-se alguns cavacos contínuos e finos. O micromecanismo prevalente de desgaste abrasivo foi de microcorte para os diferentes abrasivos usados. Portanto, nesta pesquisa, foi demonstrado que o tamanho crítico de abrasivo está relacionado com os micromecanismos de desgaste e com a morfologia dos microcavacos. / In this research, the effect of abrasive size on the wear resistance of five metallic materials was investigated. Abrasive wear tests using a pin test on alumina paper were carried out using abrasive sizes between 16 µm and 192 µm. The wear surface of the specimens was examined by scanning electron microscopy for identifying the wear micromechanism and the type of microchips formed on the abrasive paper (wear debris). In a first series of experiments mottled cast iron samples with M 3 C carbides were tested. The samples were quenched and tempered in temperatures ranging from 300°C to 600°C. For small abrasive particles, the wear mass loss increased linearly with the increase of particle size. However, for higher abrasive sizes the wear mass loss increased much more slowly. For lower abrasive sizes the main wear mechanism was microcutting. For higher abrasive sizes, the main wear mechanism was microploughing. In a second series of experiments white cast iron with M 3 C carbide with austenitic and martensitic matrix were tested. The results show that the mass loss for cast irons with austenitic and martensitic matrices increases linearly with the increase of particle size until the critical particle size is reached. The cast iron with austenitic matrix presented a critical abrasive size of 36 µm and for the martensitic cast iron, the critical particle size was about 116 µm. After the critical particle size is reached, the rate of mass loss of the cast iron with austenitic matrix diminishes to a lower linear rate, and for cast irons with martensitic matrix the curve of mass loss is non-linear and flattens when the critical particle size is reached. It becomes, then, constant, independent of additional size increases. The abrasive paper in contact with the iron of both austenitic and martensitic matrices presents fine continuous microchips and the main wear mechanism was microcutting before reaching critical particle size, and after that it presents deformed discontinuous microchips and the main wear mechanism was microploughing. This behavior of change in rates after reaching a critical size happened not only for mass loss versus abrasive size, but it was also observed both in curves of friction coefficient and specific cutting energy versus abrasive size. In a third series of experiments aluminum and AISI 1045 steel were tested. The first (FCC structure) showed similar behavior to that observed in the white cast iron with austenitic matrix and the latter showed similar behavior to that observed in white cast iron with martensitic matrix. Both aluminum and AISI 1045 steel show similar changes in the microchips morphology and in the wear micromechanisms, something that had been observed before in materials with hard second phase. In a fourth series of experiments gray cast iron was tested in order to demonstrate the relationship between the abrasive wear micromechanisms and the type of microchips, before and after achieving critical abrasive size. The grey cast iron did not show a transition in the curve of abrasive size against mass loss. The morphology of the chips was similar for the different sizes of abrasive (discontinuous). However, smaller abrasive sizes some thin continuous microchips were formed. The main abrasive wear micromechanism was microcutting for the different abrasives sizes tested. Therefore, it was shown that the critical abrasive size is related to the wear micromechanisms and the microchips morphology.
3

Resistência à abrasão de aço Hadfield para britadores: efeito do tamanho do abrasivo e do pH do meio. / Abrasion resistance of Hadfield steel for crushers: effect of the abrasive size and the pH of the environment.

Andrade, Gustavo Tressia de 29 May 2015 (has links)
Neste trabalho, foi investigado o efeito do tamanho do abrasivo e do pH do meio na resistência ao desgaste abrasivo do aço H-13 com matriz martensítica e do aço Hadfield com matriz austenítica. Ensaios de abrasão foram realizados utilizando o equipamento roda de borracha a úmido, variando o tamanho do abrasivo entre 0,15 e 2,40 mm e o pH do meio entre 5,5 e 12,8. As microestruturas dos materiais estudados foram analisadas utilizando microscopia óptica, as superfícies de desgaste e as partículas de desgaste foram analisadas em microscópio eletrônico de varredura. A macrodureza e a microdureza, antes e após os ensaios, foram obtidas utilizando durômetro Vickers. A topografia da região central da superfície de desgaste foi obtida utilizando Perfilometria 3D, visando obter valores de profundidade de penetração do abrasivo. Os resultados mostraram que o aço Hadfield é mais resistente do que o aço H-13 em todos os valores de pH e tamanhos de abrasivo utilizados. Para os dois materiais, a perda de massa aumenta linearmente até um tamanho crítico de abrasivo (TCA) e, após este, a mesma continua a aumentar, mas com uma intensidade menor. Para os dois materiais e para todos os tamanhos de abrasivo, o aumento do pH do meio resultou em menores perdas de massa, sendo este efeito maior para os dois menores tamanhos de abrasivo. Para maiores valores de pH, foram observadas menores profundidades de penetração do abrasivo. A microdureza da superfície de desgaste do aço H-13 sofreu um pequeno aumento com o aumento do tamanho do abrasivo enquanto que para o aço Hadfield esse aumento foi mais intenso. A análise das partículas de desgaste mostraram que, para todas as condições ensaiadas, os debris do aço H-13 tinham duas morfologias, contínuas e descontínuas enquanto que os cavacos do aço Hadfield foram sempre descontínuos. Para os dois materiais, foram observados dois micromecanismos de desgaste, sendo eles microcorte e microsulcamento. Por fim, os resultados apresentados neste trabalho sugerem que a análise de desempenho do aço Hadfield em serviço deve considerar o pH do meio bem como a granulometria do abrasivo em contato. / In this work, the effects of abrasive particle size and pH value of the aqueous solution on abrasive wear resistance of the H-13 steel with martensitic matrix and the Hadfield steel with austenitic matrix were investigated. Abrasive wear tests, using a wet rubber wheel abrasion tester, were carried out using abrasive sizes between 0.15 and 2.40 mm and pH values of the aqueous solution between 5.5 and 12.8. The microstructures of the materials studied were analyzed by optical microscopy and the wear surfaces and wear particles were analyzed by scanning electron microscopy. The hardness and microhardness before and after the tests were measured using a Vickers hardness tester. The topography of the middle of wear scars, were obtained by a noncontact 3D profiler in order to measure the depth of abrasive penetrations.The results show that the Hadfield steel is more wear resistant than the H-13 steel at all pH values and abrasive sizes conditions tested. For both materials, mass loss increases linearly up to a critical abrasive size, and after this the mass loss continues to increase, but with a lower intensity. Moreover, for both materials and all the abrasive sizes, increases in the pH values of the aqueous solution resulted in lower mass losses, and this effect is greater for the two smaller grain sizes. For higher pH values, lower depths of penetration of abrasive were observed. The microhardness in the wear scar surface of the H-13 steel presented a slight increase with the abrasive size, while for the Hadfield steel, this microhardness increases in a more intense form with the abrasive size. The analysis of the wear particles showed that, for all test conditions, the chips of H-13 steel has two types of morphologies, continuous or discontinuous, and for Hadfield steel only discontinuous. For both materials, two abrasive wear micromechanisms were observed, microcutting and microploughing. Finally, the results presented in this work suggest that the wear performance analysis of the Hadfield steel, to be used in an abrasive environment, must consider the effects of pH of the aqueous solution and particle size.
4

Resistência à abrasão de aço Hadfield para britadores: efeito do tamanho do abrasivo e do pH do meio. / Abrasion resistance of Hadfield steel for crushers: effect of the abrasive size and the pH of the environment.

Gustavo Tressia de Andrade 29 May 2015 (has links)
Neste trabalho, foi investigado o efeito do tamanho do abrasivo e do pH do meio na resistência ao desgaste abrasivo do aço H-13 com matriz martensítica e do aço Hadfield com matriz austenítica. Ensaios de abrasão foram realizados utilizando o equipamento roda de borracha a úmido, variando o tamanho do abrasivo entre 0,15 e 2,40 mm e o pH do meio entre 5,5 e 12,8. As microestruturas dos materiais estudados foram analisadas utilizando microscopia óptica, as superfícies de desgaste e as partículas de desgaste foram analisadas em microscópio eletrônico de varredura. A macrodureza e a microdureza, antes e após os ensaios, foram obtidas utilizando durômetro Vickers. A topografia da região central da superfície de desgaste foi obtida utilizando Perfilometria 3D, visando obter valores de profundidade de penetração do abrasivo. Os resultados mostraram que o aço Hadfield é mais resistente do que o aço H-13 em todos os valores de pH e tamanhos de abrasivo utilizados. Para os dois materiais, a perda de massa aumenta linearmente até um tamanho crítico de abrasivo (TCA) e, após este, a mesma continua a aumentar, mas com uma intensidade menor. Para os dois materiais e para todos os tamanhos de abrasivo, o aumento do pH do meio resultou em menores perdas de massa, sendo este efeito maior para os dois menores tamanhos de abrasivo. Para maiores valores de pH, foram observadas menores profundidades de penetração do abrasivo. A microdureza da superfície de desgaste do aço H-13 sofreu um pequeno aumento com o aumento do tamanho do abrasivo enquanto que para o aço Hadfield esse aumento foi mais intenso. A análise das partículas de desgaste mostraram que, para todas as condições ensaiadas, os debris do aço H-13 tinham duas morfologias, contínuas e descontínuas enquanto que os cavacos do aço Hadfield foram sempre descontínuos. Para os dois materiais, foram observados dois micromecanismos de desgaste, sendo eles microcorte e microsulcamento. Por fim, os resultados apresentados neste trabalho sugerem que a análise de desempenho do aço Hadfield em serviço deve considerar o pH do meio bem como a granulometria do abrasivo em contato. / In this work, the effects of abrasive particle size and pH value of the aqueous solution on abrasive wear resistance of the H-13 steel with martensitic matrix and the Hadfield steel with austenitic matrix were investigated. Abrasive wear tests, using a wet rubber wheel abrasion tester, were carried out using abrasive sizes between 0.15 and 2.40 mm and pH values of the aqueous solution between 5.5 and 12.8. The microstructures of the materials studied were analyzed by optical microscopy and the wear surfaces and wear particles were analyzed by scanning electron microscopy. The hardness and microhardness before and after the tests were measured using a Vickers hardness tester. The topography of the middle of wear scars, were obtained by a noncontact 3D profiler in order to measure the depth of abrasive penetrations.The results show that the Hadfield steel is more wear resistant than the H-13 steel at all pH values and abrasive sizes conditions tested. For both materials, mass loss increases linearly up to a critical abrasive size, and after this the mass loss continues to increase, but with a lower intensity. Moreover, for both materials and all the abrasive sizes, increases in the pH values of the aqueous solution resulted in lower mass losses, and this effect is greater for the two smaller grain sizes. For higher pH values, lower depths of penetration of abrasive were observed. The microhardness in the wear scar surface of the H-13 steel presented a slight increase with the abrasive size, while for the Hadfield steel, this microhardness increases in a more intense form with the abrasive size. The analysis of the wear particles showed that, for all test conditions, the chips of H-13 steel has two types of morphologies, continuous or discontinuous, and for Hadfield steel only discontinuous. For both materials, two abrasive wear micromechanisms were observed, microcutting and microploughing. Finally, the results presented in this work suggest that the wear performance analysis of the Hadfield steel, to be used in an abrasive environment, must consider the effects of pH of the aqueous solution and particle size.

Page generated in 0.1125 seconds