• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 201
  • 11
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 217
  • 141
  • 103
  • 86
  • 82
  • 68
  • 55
  • 48
  • 41
  • 39
  • 37
  • 36
  • 31
  • 30
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Análise quantitativa da anatomia dos canais radiculares distais dos molares inferiores mediante a microtomografia computadorizada

Carolina Altagracia Filpo Perez 26 June 2013 (has links)
O objetivo deste estudo foi avaliar, por meio de imagens obtidas a partir da microtomografia computadorizada (micro-ct), a morfologia interna de canais radiculares distais de molares inferiores. Cem imagens de raízes distais de primeiros e segundos molares inferiores foram obtidas com os microtomógrafos (Skyscan 1176 e 1174, Bélgica) utilizando uma resolução de 18.1μm. Após, a reconstrução das imagens foram feitos os modelos 3D com ajuda da ferramenta CTan e CTvol para a visualização e padronização segundo a classificação de Vertucci. Os seguintes parâmetros foram estudados: classificação morfológica, prevalência do canal principal e ramificações, classificação e prevalência de istmos, forma dos canais, diâmetro apical por meio das distâncias mesiodistais e vestibulolinguais e avaliação do volume apical. Para a avaliação do número, forma dos canais e a presença de istmos foi feito um registro de 9 cortes de cada imagem desde 1,0 até 5,0 mm apicais, considerando 0,5 mm aquém do comprimento real do canal. Para fazer a mensuração do diâmetro mesiodistal e vestibulolingual foi alinhada cada imagem por meio do programa DataViewer e depois foram feitas as anotações das medidas dos canais nos 5,0 mm apicais. O volume apical foi calculado de acordo com a ferramenta 3D Analysis do software CTan. Os resultados foram submetidos ao análise descritiva com o cálculo da porcentagem de ocorrência. Os resultados mostraram que a morfologia do canal mais prevalente foi a tipo I de Vertucci (76%), seguida do tipo V de Vertucci (11%). A forma do canal mais comum foi a circular de 1,0 a 3,5 mm, seguido pela oval de 4,0 a 5,0 mm. A presença de um canal único foi a mais prevalente nos níveis de 1,0 a 5,0 mm. O istmo mais observado foi o do tipo I de Hsu & Kim (86%) no nivel de 1,0 mm, seguido do tipo 5 (39%) a 5,0 mm. Na mensuração das distâncias, a vestibulolingual foi maior que a mesiodistal e o volume aumentou de apical para cervical. Conclui-se que nos canais distais a classificação de Vertucci mais comum foi a tipo I, seguida do tipo V; a presença de um canal único foi o mais prevalente tanto nos níveis de 1,0 como 5,0 mm; quanto a forma do canal, a circular foi a mais predominante desde 1,0 a 3,5 mm (65%), seguida pela forma oval em 4,0 a 5,0 mm (40%); a forma achatada foi a menos prevalente em todos os níveis. A presença de istmos mais observada foi a do tipo I, nos níveis de 1,0 a 5,0 mm. As medidas das distâncias vestibulo-linguais foram maiores em todos os níveis da raiz comparadas com as medidas mesio-distais, e o volume aumentou de apical para cervical. / The objective of this study to evaluate by means of images obtained from computed microtomography (micro-ct), the morphology of the distal root canals of mandibular molars. One hundred images of distal roots of first and second lower molars were obtained with the microtomography (Skyscan 1176 and 1174, Belgium) using a resolution of 18.1 μm. After the reconstruction of the images were analyzed with CTan and CTvol to viewing and standardization according to the classification of Vertucci. The following parameters were evaluated: morphological classification, prevalence the principal canals and ramifications, classification and prevalence isthmus, shape of the canals, through apical diameter mesio-distal and bucco-lingual interval and apical volume. For evaluation of the number, shape of the canals and the presence of isthmus were searched 9 sections of each image from apical 1.0 to 5.0 mm, 0.5 mm before the canals length. To measure mesio-distal and bucco-lingual diameter each image ranged up through DataViewer and then made notations of measurements of the canals in the apical 5.0 mm. The apical volume was calculated in according to the 3D Analysis. The results were subjected to descriptive analysis with the calculation of the percentage of occurrence. The results showed that the morphology the most prevalent was canal type I the Vertucci (76%), followed by type V the Vertucci (11%). The most common canal shape was circular 1.0 to 3.5 mm, followed by the oval in 4.0 mm to 5.0 mm. The presence of a single canal was the most prevalent in levels of 1.0 to 5.0 mm. The isthmus was the most frequently observed type I of the Hsu & Kim (86%) in the level of 1.0 mm, followed by type V (39%) to 5.0 mm. In the measurements of distances, the bucco-lingual was greater than the mesio- distal and volume increased from apical to cervical. The most common Vertuccis classification of the distal canal was the type I, followed by type V; the presence of a single canal was the most prevalent in the levels of 1.0 to 5.0 mm; in the shape of canal, the circular shape was the most common from 1.0 to 3.5 mm (65%), followed by oval shape at 4.0 to 5.0 mm (40%), the flattened shape was less frequent in all levels. The presence of isthmuses most observed was the type I, at levels of 1.0 to 5.0 mm. The measures of bucco-lingual interval were greater at all levels of the root compared to mesio-distal measures, and the volume increased from apical to cervical.
72

Estudo da anatomia radicular de segundos molares superiores por meio da Microtomografia Computadorizada

Marcela Milanezi de Almeida 29 May 2013 (has links)
O objetivo deste estudo foi avaliar qualitativa e quantitativamente a anatomia do sistema de canais radiculares de segundos molares superiores por meio de microtomografia computadorizada. Cem dentes foram escaneados no micrótomografo (SkyScan 1174) utilizando uma resolução de 19,7 μm e reconstruídos para análises bidimensionais dos número de canais principais e ramificações, diâmetro maior (V-P) e menor (M-D) a 1, 2, 3, 4 e 5mm do forame apical e área (mm2) das raízes mésio-vestibular, disto-vestibular e palatina. Após a reconstrução tridimensional das amostras escaneadas a classificação do sistema de canais radiculares foi realizada de acordo com Vertucci e os tipos adicionais. Os resultados evidenciaram que nos 2mm apicais iniciais a raiz mésio-vestibular mostrou uma frequência maior do número de canais. O diâmetro maior (V-P) das raízes avaliadas aumentou gradualmente a cada milímetro no sentido ápico-cervical, o diâmetro menor (M-D) das raízes avaliadas diminuiu no segundo milímetro apical, voltando a aumentar a partir deste, a cada milímetro avaliado. A análise tridimensional revelou uma equivalência de dados com relação a classificação de Vertucci, principalmente na raiz palatina e disto-vestibular 98% e em menor escala a raiz mésio-vestibular com 64%. Dentre os tipos de classificações adicionais foram encontrados no presente estudo, 18% dessas classificações para as raízes mésio-vestibulares, 2% para as raízes disto-vestibulares e 1% para a raiz palatina. Este estudo registrou também novos tipos de anatomia, que não se enquadraram nas classificações de Vertucci e nas classificações adicionais dos outros autores: 18% das raízes mésio-vestibulares e 1% da raiz palatina. O presente estudo confirmou por meio do microCT, a alta incidência de canais mésio-palatinos e grande quantidad de ramificações nas raízes mésio-vestibulares nos segundos molares superiores. / The aim of this study was to evaluate qualitatively and quantitatively the anatomy of the root canal system of maxillary second molars using computerized microtomography.One hundred samples were scanned at microCT (SkyScan 1174) using a resolution of 19.7 μm and reconstructed in two-dimensional slices to determine the number of main canals and branches, root canal diameter (B-P) and lower diameter (M-D) direction at 1, 2, 3, 4 and 5mm from the apical foramen. Also, the area (mm2) of the mesiobuccal, distobuccal and palatal roots was analyzed. The classification of the root canal system was performed according to Vertucci and additional authors classifications. The results showed that at the apical third, the mesiobuccal root showed a higher frequency of root canals and ramifications. In overall, the bucco-palatal diameter (B-P) and mesio-distal diameter (M-D) gradually increased from the apical to the cervical third. Threedimensional analysis revealed that 98% of disto-buccal and palatal canals fits in the Vertuccis classification. In the mesiobuccal canal 64% of the anatomies could be described by the Vertucci classification. Other authors classifications were found in 18% of mesiobuccal roots, 2% on distobuccal roots and 1% on palatal roots. This study found new types of root canal anatomies that were not previously described, mainly, in the mesiobuccal and palatal roots (19%). It can be concluded that the mesial buccal roots in maxillary second molars show a higher complexity in comparison to the distobuccal and palatal root.
73

Avaliação do reparo tecidual em defeito ósseo por microtomografia tridimensional por raio X / Evaluation of tissue repair after bone fracture using 3D X-ray microtomography

Simone Orlandi Introini 01 July 2011 (has links)
A fratura é uma descontinuidade óssea que pode ser produzida cirurgicamente ou causada por um impacto que excede a resistência mecânica do osso dando início a uma sequência de eventos sistêmicos e específicos de resposta do tecido. Exames radiológicos são comumente realizados na clínica e em experimentos com animais para o monitoramento do reparo ósseo dando informações sobre o alinhamento dos fragmentos e da evolução de reparo. Outras técnicas de monitoramento qualitativas e quantitativas podem ser utilizadas em experimento animal (histologia e ensaios mecânicos) e em experimento animal e clínico (tomografia computadorizada por raio X, ressonância magnética, ultra-sonografia). A microtomografia 3D por raio X é uma nova técnica de monitoramento para uso em experimento animal e com grande potencialidade. A quantificação do reparo ósseo com novas metodologias tem larga aplicação em investigações sobre técnicas invasivas e não-invasivas de tratamento de fraturas utilizando-se experimento animal. O objetivo dessa investigação foi a utilização da microtomografia 3D por raio X policromático (\'mü\'CT) para a avaliação do reparo ósseo em defeito ósseo na tíbia direita de rato macho da raça Wistar com peso aproximado de 280 g. O defeito foi produzido por uma broca odontológica com alta rotação. Foram estabelecidos quatro grupos experimentais caracterizados pela utilização ou não utilização do tratamento do defeito por ultra-som pulsado de baixa intensidade (LIPUS, 30 mW/\'CM POT.2\') e pela duração do experimento. No grupo 1 o tratamento por ultra-som teve a duração de 14 dias, 5 sessões de tratamento por semana. No grupo 2 não houve tratamento por ultra-som e a duração foi de 14 dias. No grupo 3 o tratamento por ultra-som teve a duração de 21 dias, 5 sessões de tratamento por semana. No grupo 4 não houve tratamento por ultra-som e a duração foi de 21 dias. Nos grupos 1 a 4 foram utilizados 10 animais para a avaliação por CT. O defeito ósseo da tíbia direita nos animais dos grupos 1 e 3 foi tratado com ultra-som de baixa intensidade. A avaliação por CT foi realizada através dos softwares NRecon, Data Viewer , CT-Analyzer e CT-Vol fornecidos pelo fabricante do microtomógrafo (Skyscan, Bélgica). Não foi observada diferença estatísticamente significante na quantificação do reparo ósseo dos defeitos dos grupos 1 e 2 e dos grupos 3 e 4. / Fracture is a bone discontinuity that can be surgically produced or caused by an impact that exceeds the mechanical strength of bone by initiating a series of systemic events and specific tissue response. Radiological tests are commonly performed in clinical and animal experiments for monitoring the bone healing by providing information about the alignment of the fragments and the evolution of repair. Other techniques for monitoring quality and quantity can be used in experimental animals (histology and mechanical tests) and in animal experiments and clinical studies (computed tomography X-ray, MRI, ultrasound). The 3D microtomography by X-ray is a new monitoring technique for use in animal experiment and with great potential. The quantification of bone repair with new methods has wide application in research on invasive and noninvasive treatment of fractures using animal experiment. The goal of this research was to use the 3D microtomography by non monochromatic X-ray (\'mü\'CT) to evaluate the bone healing in bone defect in the tibia of Wistar male rat weighing approximately 280 g. The defect was produced by a dental drill with high speed. It was established four experimental groups characterized by the use or non use of low intensity pulsed ultrasound (LIPUS, 30 mW/\'CM POT.2\') for the bone defect treatment as well as the duration of the experiment. In group 1 the LIPUS treatment last 14 days, 5 treatment sessions per week. In group 2 the LIPUS treatment was not used and the duration was 14 days. In group 3 the LIPUS treatment last 21 days, 5 treatment sessions per week. In group 4 the LIPUS treatment was not used and the duration was 21 days. In groups 1 to 4, 10 animals were used for evaluation by CT. The evaluation was conducted by CT through software NRecon, Data Viewer, CT-Vol and CT-Analyzer supplied by the microtomography manufacturer (SkyScan, Belgium). No significant statistical differences were found between the results of groups 1 and 2 as well as the results of groups 3 and 4.
74

Avaliação, por meio de microtomografia computadorizada, da anatomia interna e externa de primeiros pré-molares superiores / Evaluation of the external and internal anatomy of maxillary first premolars, using computed microtomography

Amanda Buosi de Biagi 29 August 2014 (has links)
O objetivo do presente estudo foi avaliar a anatomia do sistema de canais radiculares (SCR) de 72 primeiros pré-molares superiores (32 unirradiculares, 30 birradiculares com sulcos e 10 trirradiculares), por meio de microtomografia computadorizada (μCT). As amostras foram escaneadas no microtomógrafo SkyScan 1174 v2, e as imagens geradas foram reconstruídas para análise dos parâmetros bidimensionais (número, área, circularidade , diâmetro maior e menor, fator de forma) a 1, 2, 3 mm do forame apical e tridimensionais (volume, área de superfície, índice de estrutura do modelo - SMI, número e localização de canais acessórios), bem como avaliação das características anatômicas externas da raiz (presença, localização, profundidade e extensão do sulco e espessura interna e externa de dentina) e análise qualitativa dos modelos tridimensionais. Os resultados mostraram que o número máximo de canais no terço apical foi três. A 1 mm do forame apical, nos dentes unirradiculares, o diâmetro maior foi, em média, duas vezes maior que o diâmetro menor. O padrão de circularidade demonstrou forma circular com tendência ao achatamento dos canais dos dentes unirradiculares e uma forma mais circular nos canais dos bi e trirradiculares, principalmente nas raízes palatinas. Os resultados do fator de forma confirmaram a forma mais circular dos canais em todos os dentes avaliados. Na análise tridimensional, as maiores médias de volume (14,84±10,78mm³) e área de superfície (83,65±48,26mm²) foram encontradas nos canais radiculares dos pré-molares unirradiculares, e as menores médias de volume (3,78±1,61mm³) e área de superfície (25,11±6,17mm²) foram observadas na raiz disto-vestibular dos primeiros pré-molares superiores trirradiculares. Os valores de SMI foram semelhantes em todas as raízes nos três grupos dentais avaliados, evidenciando uma forma tridimensional cônica com tendência cilíndrica dos canais radiculares. A presença de um canal acessório variou de 45% a 100% no terço apical e de 15% a 100% no terço médio em todas as raízes dos grupos dentais avaliados. Na análise radicular externa, foram encontrados 35 sulcos radiculares (23 únicos e 12 duplos), sendo encontrados na face palatina da raiz vestibular em 100% dos pré-molares superiores birradiculares. A profundidade do sulco apresentou maior valor médio (0,57±0,27mm) na secção transversal correspondente à 1mm acima da metade da extensão total do sulco. O teste de correlação mostrou que nas secções transversais mais cervicais em relação ao suco, quanto maior a sua profundidade, maior é o achatamento e a ocorrência de divisão dos canais radiculares. Os modelos tridimensionais evidenciaram a prevalência da classificação tipo IV de Vertucci. Dessa forma, conclui-se que a μCT possibilitou o estudo detalhado da anatomia interna e externa do SCR em primeiros pré-molares superiores uni, bi e trirradiculares. / The aim of this study was to evaluate the anatomy of the root canal system (RCS) of 72 maxillary first premolars (32 single-rooted, 30 two-rooted with radicular grooves and 10 three-rooted), using computed microtomography (μTC). The specimens were scanned with the SkyScan 1174v2 microtomography device and the images were reconstructed for analysis of two-dimensional parameters (number, area, roundness, major diameter, minor diameter, and form factor) at 1, 2 and 3 mm of the apical foramen, and three-dimensional parameters (volume, surface area, structure model index - SMI, number and location of accessory canals), as well as examination of external anatomic characteristics of the roots (presence, location, depth and extension of the grooves, and internal and external dentin thickness) and qualitative analysis of the three-dimensional models. No more than three canals were found in the apical third. At 1 mm from the apical foramen in single-rooted teeth, mean values of the major diameter were twice as higher than those of the minor diameter. The roundness pattern of the canals revealed a round shape with a tendency to flattening in the single-rooted premolars, and a shape with more accentuated roundness in the two- and three-rooted premolars, mainly in the palatal roots. The form factor results confirmed the more circular shape of all teeth. In the three-dimensional analysis, the highest values of mean volume (14.84±10.78mm³) and surface area (83.65±48.26mm²) were found in the canals of the single-rooted premolars, and the lowest values of mean volume (3,78±1,61mm³) and surface área (25,11±6,17mm²) were observed in the distobuccal root of the three-rooted premolars. The mean SMI values were similar in all roots of the three groups of premolars, indicating a tendency to a 3D cylinder-like geometry of the canals. The presence of one accessory canal ranged from 45 to 100% in the apical third and 15 to 100% in the middle third in all evaluated roots. In the examination of the external root surface, 35 radicular grooves (23 singles and 12 doubles) were found, with prevalence (100%) in the palatal face of the buccal root in two-rooted premolars. The radicular groove depth presented higher mean value (0.57±0.27mm) in the cross-section corresponding to 1 mm above the middle point of the full length of the groove. The correlation test showed that in the cross-sections more coronal to the groove, the greater the depth, the more accentuated the flattening and the greater the occurrence of division of the canals within the root. The analysis of the tree-dimensional models demonstrated the prevalence of Vertucci\'s type IV configuration. In conclusion, the use of μCT provided a detailed evaluation of the internal and external anatomy of the RCS in singlerooted, two-rooted and three-rooted maxillary first premolars.
75

Efeito da Interação Entre o Flúor e a Irradiação com Lazer Nd: YAG na Prevenção de Desmineralização IN VITRO

Gomes, Angelinne Ribeiro Angelo 14 August 2015 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-05-19T15:10:35Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE ANGELINNE UFPE final.pdf: 3581361 bytes, checksum: 1339333592e5d5e1f75e70ed7c727620 (MD5) / Made available in DSpace on 2016-05-19T15:10:35Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE ANGELINNE UFPE final.pdf: 3581361 bytes, checksum: 1339333592e5d5e1f75e70ed7c727620 (MD5) Previous issue date: 2015-08-14 / Introdução. Esforços têm sido direcionados para a redução do risco à cárie dentária através da adoção de medidas preventivas e motivacionais. Evidências recentes apontam que a irradiação com laser é eficaz no aumento da resistência dentária à desmineralização promovida durante o processo cariogênico. No entanto, ainda não há um consenso quanto a melhor forma de uso clínico do laser. Objetivos. Este estudo visou avaliar, num modelo in vitro, o efeito da interação entre e a irradiação do laser Nd:YAG com um verniz de flúor na prevenção da desmineralização do esmalte dentário. Materiais e Métodos. Cento e dez espécimes de esmalte foram distribuídos em 5 grupos, a saber: Grupo 1 – Controle, Grupo 2 – Flúor, Grupo 3 – Laser, Grupo 4 – Flúor/Laser e Grupo 5 – Laser/Flúor. Os grupos 3,4 e 5 foram subdivididos em 3 subgrupos cada de acordo com as potências utilizadas (0,5, 075 e 1W), totalizando 11 grupos com 10 espécimes cada. Os tratamentos superficiais consistiram no uso do laser Nd:YAG e verniz fluoretado isolados e em associação, seguido de um processo de desmineralização in vitro por 48 horas. Em sequência, as amostras foram escaneadas em um microtomógrafo de raios–X (XTEK XT-H 225 ST microfocos) e as imagens obtidas foram reconstruídas e processadas para quantificar a perda mineral e a diferença de densidade mineral entre as áreas exposta e não-exposta do esmalte dentário. Resultados. O grupo 1 apresentou maior perda mineral (89,8 ± 24,6μm) (p<0,001). Amostras tratadas com flúor apresentaram perda mineral semelhante aos grupos tratados com laser e associações de laser flúor (p>0,05). A diferença de densidade mineral do esmalte apresentou-se maior no grupo 1 (1.756 ± 746HU) (p<0,001). O uso isolado do flúor e os tratamentos laser/flúor demonstraram as menores médias na variação da densidade. Conclusões. O uso exclusivo do laser e suas associações com o verniz fluoretado mostraram-se semelhantes ao uso exclusivo do flúor. A associação do verniz fluoretado com o laser apresenta melhor performance quando o laser Nd:YAG é utilizado previamente ao verniz. / Introduction. Efforts have been directed to reducing the risk of caries adopting preventive and motivational measures. New found evidence suggests that the laser irradiation is effective in increasing the resistance to tooth demineralization promoted during the cariogenic process. However, there is still no consensus on the best way of laser clinical use. Objectives. This study aimed to evaluate an in vitro model, the effect of interaction between the radiation and the Nd:YAG laser with a fluoride varnish on the prevention of demineralization of dental enamel. Materials and methods. One hundred and ten enamel specimens were distributed into 5 groups as follows: Group 1 - Control, Group 2 - Fluoride, Group 3 - Laser, Group- 4 - Fluoride/Laser, Group 5 - Laser /Fluoride. Groups 3,4 and 5 were each subdivided into 3 subgroups according to the power (0.5, 075, and 1W), a total of 11 groups of 10 specimens each. The surface treatment consisted in the use of Nd: YAG laser and fluoride varnish isolated and in combination, followed by a process of demineralization in vitro for 48 hours. In the following, the specimens were scanned at a X-ray microtomography (XT-H Xtek microfocus ST 225) and images were reconstructed and processed to quantify the mineral loss and the mineral density difference between the exposed and non-exposed areas enamel. Results. Group 1 showed higher mineral loss (89.8 ± 24,6μm) (p <0.001). Samples treated with fluoride mineral loss showed similar to the groups treated with laser and Fluorine laser associations. The difference mineral density was higher in Group 1 (1.756 ± 746HU) (p <0.001). The isolated use of fluoride and treatments laser/fluoride promoted smaller mean of density. Conclusions. The exclusive use of laser and their association with fluoride varnish were similar to the exclusive use of fluoride. The association of fluoride varnish with laser shows better performance when the Nd: YAG laser is first used to varnish.
76

Avaliação do efeito do ácido zoledrônico na periodontite induzida em ratos: análise histológica e microtomográfica / Avaliação do efeito do ácido zoledrônico na progressão da doença periodontal em ratos: análise morfológica e microtomográfica

MARCELOS, Priscylla Gonçalves Correia Leite de 15 February 2017 (has links)
Submitted by Pedro Barros (pedro.silvabarros@ufpe.br) on 2018-08-08T20:41:30Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Priscylla Gonçalves Correia Leite de Marcelos.pdf: 1912691 bytes, checksum: 75b6cc38aa3a5515bf5ed8df03dbc52c (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-08-16T22:53:15Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Priscylla Gonçalves Correia Leite de Marcelos.pdf: 1912691 bytes, checksum: 75b6cc38aa3a5515bf5ed8df03dbc52c (MD5) / Made available in DSpace on 2018-08-16T22:53:15Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Priscylla Gonçalves Correia Leite de Marcelos.pdf: 1912691 bytes, checksum: 75b6cc38aa3a5515bf5ed8df03dbc52c (MD5) Previous issue date: 2017-02-15 / CAPES / O objetivo neste trabalho foi avaliar a ação do ácido zoledrônico (zometa) na progressão da periodontite induzida em primeiros molares inferiores de ratos. Foram utilizados 48 ratos Wistar distribuídos aleatoriamente em 6 grupos experimentais (n=8 cada grupo), sendo 3 grupos expostos ao fármaco zometa (0,15mg/kg) e 3 grupos controles tratados com soro a 0,9%: Zom/Lig30 – animais expostos ao fármaco por 4 semanas com posterior indução da periodontite com de fio de sutura no último dia de droga e eutanásia 30 dias após a indução; Zom/Lig15 – grupo tratado por 4 semanas com posterior indução da periodontite no último dia de droga e eutanásia 15 dias após a indução; Lig/Zom – grupo no qual foi induzida a periodontite e 15 dias após, o zometa foi administrado por 8 semanas. A eutanásia ocorreu 1 semana após a última dosagem. Os grupos Con/Lig30, Com/Lig15 e Lig/Con, representam, respectivamente, os controles dos grupos citados acima. Após o sacrifício, as hemi-mandíbulas esquerdas foram removidas e avaliadas por meio de microtomografia computadorizada (μCT) e histometria. A perda óssea foi mensurada nas regiões de furca e raiz distal na microtomografia e na histometria. A presença da osteonecrose foi avaliada histologicamente. Os dados foram avaliados utilizando o teste t Student, para análise da microtomografia e Mann-Whitney para a histometria, ambos com nível de significância de 5%. Na histologia, foi possível evidenciar osteonecrose nos grupos Zom/Lig30, Zom/Lig15 e Con/Lig30. Na μCT, a raiz distal no grupo Lig/Con apresentou maior reabsorção comparado com o Lig/Zom (p<0,05). Na histometria, o osso alveolar da raiz distal apresentou maior reabsorção nos grupos Zom/Lig30 (p=0,005), Con/Lig15 (p<0,001) e Lig/com (p=0,001). Enquanto que a furca teve maior reabsorção nos grupos Zom/Lig30 (p=0,046) e no grupo Lig/Con (p<0,001). Conclui-se que o ácido zoledrônico diminui a reabsorção óssea alveolar em periodontite induzida em ratos tratados com a droga a longo prazo, além de apresentar o risco de desenvolver osteonecrose dos maxilares associados a bisfosfonatos na presença de trauma tecidual e infecção. / The aim of this study was to evaluate the action of zoledronic acid (zometa) on the progression of periodontitis induced in the lower first molars of rats. A total of 48 Wistar rats randomly distributed in 6 experimental groups (n = 8 each) were used. Three groups were exposed to drug zometa (0.15mg/kg) and three control groups treated with 0.9% serum: Zom/Lig30 - Animals exposed to the drug for 4 weeks with subsequent induction of periodontitis with suture wire on the last day of drug and euthanasia 30 days after induction; Zom/Lig15 - group treated for 4 weeks with subsequent induction of periodontitis on the last day of drug and euthanasia 15 days after induction; Lig/Zom - group in which periodontitis was induced and 15 days later, zometa was given for 8 weeks. Euthanasia occurred 1 week after the last dosing. The groups Con/Lig30, Con/Lig15 and Lig/Con, respectively, represent the controls of the groups mentioned above. After sacrifice, the left hemi-jaws were removed and evaluated by means of Computerized Microtomography (μCT) and histometry. Bone loss was measured in the furcation and distal root regions in microtomography and histometry. The presence of osteonecrosis was evaluated histologically. The data were evaluated using Student's t test for microtomography and Mann-Whitney for histometry, both with significance level of 5%. In histology, it was possible to show osteonecrosis in the Zom/Lig30, Zom/Lig15 and Con/Lig30 groups. In the μCT, the distal root in the Lig/Con group presented greater resorption compared to the Lig/Zom (p <0.05). In histometry, alveolar bone of the distal root presented greater resorption in the Zom/Lig30 (p = 0.005), Con/Lig15 (p <0.001) and Lig/Con (p = 0.001) groups. While the furca had greater resorption in the Zom/Lig30 groups (p = 0.046) and in the Lig/Con group (p <0.001). It is concluded that zoledronic acid decreases alveolar bone resorption in periodontitis induced in rats treated with the drug in the long term, and presents the risk of developing osteonecrosis of the maxilla associated with bisphosphonates in the presence of tissue trauma and infection.
77

Avaliação da anatomia de molares decíduos por meio de microtomografia computadorizada / Evaluation of the anatomy of primary molars using the microcomputed tomography

Ana Caroline Fumes 25 June 2013 (has links)
O conhecimento prévio da anatomia interna e externa dos dentes decíduos é de fundamental importância para o sucesso do tratamento endodôntico. O objetivo do presente estudo foi analisar a morfologia das raízes e dos canais radiculares de molares decíduos superiores e inferiores, por meio de microtomografia computadorizada (micro-CT). Foram usados 40 molares decíduos, divididos em quatro grupos, sendo 10 primeiros molares inferiores, 10 segundos molares inferiores, 10 primeiros molares superiores e 10 segundos molares superiores. Os dentes foram escaneados e avaliados quantitativamente por meio de parâmetros bidimensionais no terço apical (número, área, circularidade, maior e menor diâmetro) a 1, 2 e 3 mm do bisel de rizólise e tridimensionais (volume, área de superfície e SMI), assim como a medida da espessura na face interna e externa da dentina e qualitativamente por meio da observação dos modelos tridimensionais. Os resultados mostraram que o número máximo de canais radiculares encontrados por raiz foi 2. Os canais apresentaram valores de SMI entre 1,98 ± 0,45 e 2,74 ± 0.38, sugerindo forma geométrica tridimensional com tendência a um cone. Para a espessura da dentina, observou-se que a espessura da dentina na face interna das raízes foi, em geral, menor que a espessura na face externa. Os valores de espessura interna variaram entre 0,25 e 0,90 mm na raiz mesial e 0,20 e 0,92 mm na raiz distal para os molares inferiores e, 0,14 e 1,00 mm na raiz mesiovestibular, 0,24 e 1,14 mm na raiz distovestibular e 0,26 e 1,54 mm na raiz palatina para os molares superiores. Em relação à espessura externa, a variação foi de 0,35 a 1,45 mm na raiz mesial e 0,32 a 1,52 mm na raiz distal para os molares inferiores e, 0,22 a 1,33 mm na raiz mesiovestibular, 0,28 a 1,40 mm na raiz distovestibular e 0,44 a 2,24 mm na raiz palatina nos molares superiores. Foi observado também, que a extensão da raiz foi sempre maior que a extensão do canal. Dessa forma, conclui-se que as variações anatômicas observadas e os parâmetros obtidos a partir da micro-CT, método não destrutivo, reprodutível e confiável para o estudo de anatomia interna e externa, são importantes para determinar protocolos clínicos nos casos de dentes decíduos. / The previous knowledge of the internal and external anatomy of primary teeth is of fundamental importance for the success of the endodontic treatment. The purpose of this study was to analyze the morphology of the roots and root canals of the upper and lower primary molars, using the microcomputed tomography (micro-CT). Forty primary molars, divided in four groups, ten first lower molars, ten second lower molars, ten first upper molars and ten second upper molars. The teeth were scanned and assessed quantitatively by the observation of two-dimensional parameters in the apical third (number, area, roundness, major and minor diameter) at 1, 2 and 3 millimeters of the resorption bevel and three-dimensional parameters (volume, surface area and SMI), as well as the measurement of internal and external dentin thickness and qualitatively by means of observation of the three-dimensional models. The results showed that the maximum number of root canals found for each root was 2. The canals have SMI values between 1.98 ± 0.45 and 2.74 ± 0.38, suggesting a three-dimensional geometrical shape with a tendency to conical. For the dentin thickness of the internal wall of the roots, in general the values were lower than the ones for the external wall. The values of the internal thickness ranged between 0.25 and 0.90 mm in the mesial root and 0.20 and 0.92 mm in the distal root for the lower molars and 0.14 and 1.00 mm on the mesio-vestibular root, 0.24 and 1.14 mm on the disto-vestibular and 0.26 and 1.54 mm on the palatal for the upper molars. Regarding the external thickness, it ranged between 0.35 and 1.45 mm on the mesial root and 0.32 and 1.52 mm on the distal for the lower molars, and 0.22 and 1.33 mm on the mesio-vestibular, 0.28 and 1.40 mm on the disto-vestibular and 0.44 and 2.24 mm on the palatal root of the upper molars. It was observed that the dentin thickness of the external wall was always higher than the extension of the canal. That way, it can be concluded that the observed anatomical variations and the obtained parameters from the micro-CT, a non-destructive method, reproducible and reliable for the study of internal and external anatomy, are important to define clinical protocols for the primary teeth.
78

Efeito do LED infravermelho sobre a movimentação dentária induzida em ratos / Infrared LED phototherapy effects on induced tooth movement in rats

Simone Peixe Friedrichsdorf 14 August 2015 (has links)
O LED infravermelho tem sido considerado uma alternativa efetiva para o laser na bioestimulação. Entretanto, o efeito na remodelação óssea durante o movimento ortodôntico ainda deve ser esclarecido. Oitenta ratos machos com 10 semanas de idade, foram divididos em dois grupos de 40 animais cada: grupo LED (GLED) e grupo controle (GCON), e tiveram seu 1ºmolar superior esquerdo submetido a força de 10 g com uma mola helicoidal fixada entre o 1ºmolar superior esquerdo e incisivo superior esquerdo. Durante os primeiros cinco dias de movimentação dentária foi aplicada a luz infravermelha LED (850nm, 30mW) durante 5 minutos no GLED. O GCON não foi irradiado. Em 0, 7, 14 e 21 dias, 5 animais de cada grupo foram submetidos a microtomografia computadorizada. Para a avaliação histológica, todos os ratos foram subdivididos em subgrupos de 20 animais cada de acordo com a o dia da eutanásia 4, 7, 14 e 21 dias e as maxilas foram dissecadas e processadas para a microscopia de luz (HE e TRAP). A quantidade de movimento, segundo as microtomografias computadorizadas, foi maior no grupo LED em T1 (intervalo entre os dias 0 e 7) e em T3 (intervalo entre os dias 14 e 21). No dia 4 foi observada hialinização na área de pressão em ambos os grupos; nos períodos posteriores, 7, 14, a área hialina foi vista apenas no grupo controle. A reabsorção radicular ocorreu em ambos os grupos após o dia 7. A fototerapia LED melhora a movimentação dentária e minimiza a hialinização durante o movimento ortodôntico. Entretanto, não reduz o risco de reabsorção da superfície radicular. / Infrared LED has been considered an effective alternative to infrared LASER for biostimulation purposes. However, its effect on bone remodeling during orthodontic tooth movement (OTM) is unknown. Eighty 10 week-old male Wistar rats were divided into two groups of forty animals each: LED group (GLED) and control group (GCON) and had a coiled spring bonded to the first upper molar and upper incisor exerting 10g force to mesially move the molar. During the first five days of OTM the maxillae were daily irradiated with infrared LED (850nm, 30mW) during 5 minutes (LED group). The controls were not irradiated (GCON). At 0, 7, 14 and 21 days, 5 LED group and 5 CON group rats were submitted to ?CT. For the histological study, all rats were subvided into subgroups of 20 animal each according to the euthanasia day 4, 7, 14 e 21 days. The rats were euthanized after 4, 7, 14 and 21 days and the maxillae were processed to light microscopy and TRAP histochemistry. The amount of tooth movement was greater in the GLED on days 7 and 14. At 4 day, hyalinization was seen at the pressure areas in both groups; on the subsequent days it was seen only in the GCON. Root resorption occurred in both groups after 7 days. LED phototherapy enhances early tooth movement and minimizes periodontal hyalinization during OTM. However, it does not reduce the risk of tooth resorption.
79

Análise ex vivo de cortes apicais de dentes humanos em 3D empregando microtomografia computadorizada / Ex vivo analysis of apical human tooth in 3D sections using computed micro-CT

Marcia Regina Ramalho da Silva Bardauil 08 July 2010 (has links)
O objetivo deste estudo in vivo foi investigar as imagens obtidas por microtomografia computadorizada (micro-TC) no estudo da anatomia apical de dentes humanos portadores de polpa viva e mortificada. Trinta e cinco dentes humanos unirradiculares ou multirradiculares que tiveram suas raízes separadas totalizando quarenta e uma raízes foram rigorosamente pré-selecionadas e divididas em dois grupos: com polpa viva (PV) n = 21 e com polpa mortificada (PM) n = 20. Os dentes de ambos os grupos foram escaneados pelo sistema de microtomografia computadorizada (SkyScan 1172) com resolução de 6,7m e suas imagens reconstruídas para a análise da região apical nos cortes sagital e coronal. O diâmetro do forame apical (FA) e da junção cemento-dentina (JCD) foram medidos bem como suas distâncias (extensão do cemento) em ambos os lados da raiz. Posteriormente a coroa dos dentes foi cortada no seu colo anatômico e suas raízes foram medidas com paquímetro eletrônico e a odontometria realizada com localizador eletrônico apical (RomiApex A15). A subtração desses dois dados foi correlacionada com as medidas obtidas pela micro-TC na avaliação da posição da JCD. As raízes foram preparadas para avaliação histológica em cortes longitudinais de 6m de espessura e corados com HE. Os cortes que apresentaram a emergência do FA foram fotografados digitalmente e as imagens correspondentes de micro-TC foram sobrepostas com o intuito de ilustrar a metodologia utilizada. As medidas da micro-TC foram realizadas por dois examinadores devidamente instruídos. A concordância inter-examinadores foi confirmada pelo coeficiente de correlação intraclasse (ICC) e as medidas foram comparadas pelo teste de Mann-Whitney (teste de Wilcoxon rank sum - p0,05). Os resultados indicaram que não houve diferença estatisticamente significante quanto à extensão do cemento intrarradicular nos grupos quer de polpa viva como mortificada com distâncias de 0,32±0,1mm e 0,36±0,16mm respectivamente. As medidas realizadas pelo localizador apical, a 1,0mm aquém, garantiu o estabelecimento do limite dentro do canal dentinário. Os resultados encontrados para o diâmetro do forame apical foi 619,32±32 m para o grupo PV e 630,542±140,99m para o grupo PM sem diferença estatisticamente significante. O diâmetro do canal radicular na junção cemento-dentina não apresentou diferença estatisticamente significante entre PV com 330,37±126,62m e PM com 357,62±996,14m. O posicionamento da JCD em relação ao FM não foi influenciado pelo estado de vitalidade pulpar. / This ex vivo study aimed to investigate the apical anatomy of vital and necrotic human roots by microcomputed tomography (micro-CT). Thirty-five single or multirooted human teeth that had their roots separated totaling forty-one roots were carefully pre-selected and divided into two groups: vital pulp (VP) n = 21 and necrotic pulp (NP) n = 20. Both groups were scanned by microcomputed tomography system (SkyScan 1172) with 6.7m resolution and the apical region was analyzed by reconstructed images in sagittal and coronal sections. The diameters of the apical foramen (AF) and root canal at the cemento-dentino canal junction (CDJ) were measured. The cementum extension into the root canal was measured on both sides of the root canal. Thereafter the teeth crown was cut at the cemento-enamel junction, the length of roots was measured with a caliper and the working length was performed by an electronic apex locator (RomiApex A15). The result of the subtraction of these two data was correlated with measures obtained by micro-CT in the evaluation of CDJ position. The roots were sectioned in longitudinal histological sections of 6m thickness and stained with HE. The sections that showed the emergence of the FA were digitally photographed and the corresponding micro-CT sections were correlated by superimposition in order to illustrate the methodology. Measures of micro-CT scans were performed by two calibrated examiners. The interexaminers agreement was confirmed by intraclass correlation coefficient (ICC) and measurements were compared by Mann-Whitney test (Wilcoxon rank sum test - p0.05). The results indicated that there was no statistically significant difference in relation to the extension of cementum into the root canal in both goups VP or NP with average distances of 0.32±0.1mm and 0.36±0.16mm respectively. The measurements taken by the apex locator 1 mm from the apex were within the limits of dentinal canal. The diameter of the apical foramen corresponded to the NP group was 619.32±201.61m and 619.32±140.99m on average, not statistically significant. The average diameter of the root at the CDJ was 330.37±126.62m for VP and 357.62 ±96.14m for NP groups presenting no statistically significant difference. The distance of the CDJ in relation to AF was not influenced by the pulp vitality.
80

Avaliação por densitometria óssea e microtomografia computadorizada 3D de (compósito) manta óssea à base de quitosana, hidroxiapatita e colágeno, como reparo de falhas ósseas induzidas experimentalmente em tíbias de ovinos / Evaluation by bone densitometry and 3D micro-computed tomography of chitosan, hydroxyapatite and collagen composite as bone substitute in bone defect experimentally induced in the tibia of sheep

Cinthia Lima Lhamas 16 November 2016 (has links)
A ocorrência de fraturas em animais e, especialmente nas espécies de grande porte, geram preocupação quanto ao custo do tratamento e a ocorrência de sequelas, pois há a possibilidade de complicações pela carga excessiva que esses animais exercem sobre os membros. Dessa forma é importante a imobilização imediata do membro e de maneira adequada, e avaliar se há necessidade de se realizar cirurgia para estabilização da fratura. Em algumas fraturas pode haver falhas ósseas, principalmente em fraturas cominutivas com extensa lesão de tecidos adjacentes, o que dificulta e prolonga o tempo de consolidação. Por essas razões vem sendo estudado, há alguns anos, o uso de substitutos ósseos na forma de cimentos ou mantas ósseas para reparar esses defeitos. O estudo com biomateriais como substitutos ósseos tem tido grande evolução nos últimos anos, e aqueles à base de quitosana, hidroxiapatita e colágeno apresentam grande vantagem, pois a quitosana estimula a regeneração óssea, a hidroxiapatita confere a dureza que o material exige, e o colágeno fornece maleabilidade. O presente projeto teve por objetivo avaliar o reparo ósseo após implante de compósito à base de quitosana, hidroxiapatita e colágeno, em falhas ósseas de tíbias de ovinos induzidas experimentalmente. Foram utilizados os métodos de imagem por densitometria ótica radiográfica e microtomografia computadorizada 3D para avaliar o grau e o tempo de reparo ósseo, assim como a densidade mineral óssea durante a cicatrização. As falhas ósseas foram confeccionadas nas tíbias de ovelhas, em ambos os membros, onde foi implantado o biomaterial em um deles, e o membro contralateral mantido como controle. Posteriormente, os animais foram submetidos a exames radiográficos, quinzenalmente, até 90 dias de pós operatório. Após este período, os animais foram submetidos à eutanásia e fragmentos das tíbias foram colhidos para avaliação por microtomografia computadorizada 3D. Observou-se, pelos resultados qualitativos das imagens radiográficas e dos dados estatísticos, que houve absorção gradativa do biomaterial, e que não houve diferença estatística em relação à densidade mineral óssea entre os dois grupos estudados, embora a DMO tenha sido maior nos membros com o biomaterial. Este método mostrou-se prático e eficaz, além de ser uma técnica não invasiva. A microtomografia computadorizada 3D revelou importantes informações quanto à porosidade óssea e volume ósseo entre os dois grupos. As imagens em 3D mostraram detalhes do osso que não eram possíveis de visualizar por meio das radiografias. Dessa forma é uma técnica bastante eficaz e detalhada, mas é necessária padronização de todas as amostras para poder quantificar os valores adequadamente. O estudo estatístico não mostrou diferenças entre os grupos com biomaterial e controle para os parâmetros de volume ósseo, grau de porosidade e porcentagem de volume ósseo. Porém, pelas imagens em 3D observa-se nitidamente maior quantidade de poros nas amostras controle em relação às amostras com biomaterial. Conclui-se com este estudo que as técnicas de densitometria óssea por raios-X e &micro;CT 3D são bastante eficazes para avaliar a cicatrização óssea em ovinos / The occurrence of fractures in animals and, especially, in large animals are conditions that generate concern about the cost of treatment and the occurrence of future complications because there is the possibility of complications due to excessive load that these animals receive in their limbs. Thus, it is important the limb immobilization immediately and appropriately and assess whether it is necessary to perform surgery to stabilize the fracture. In some kinds of fractures, it might have large bone defects, mainly in comminuted fractures with extensive damage to surrounding tissue, which makes it more difficult and prolongs the consolidation time. For these reasons, scientists have been studied the use of bone substitutes in the form of bone cements to repair these defects. The study of biomaterials as bone substitutes has had great progress in last years, and those based on chitosan, hydroxyapatite and collagen had great advantage because chitosan stimulates bone regeneration, hydroxyapatite confers the hardness that the material requires, and collagen provides flexibility to the material. This project aims to assess bone repair after deploying a composite of chitosan, collagen and hydroxyapatite in bone defects experimentally induced in sheep tibiae. For assessing the degree and the time of bone healing, it was used imaging techniques like radiographic bone densitometry and 3D micro-computed tomography. Bone defects were made in the sheep tibiae in both limbs where the biomaterial was deployed in one of them, and the control was the contralateral limb. After the surgeries, the animals were submitted to radiographic exams every two weeks until 90 days postoperatively. After this period, the animals were euthanized and harvested tibiae fragments for evaluation by 3D micro-computed tomography. Through the qualitative results of images and statistical data, it was observed, radiographically, that there was a gradual absorption of the biomaterial, and also that there was no statistical difference in relation to bone mineral density between the two groups. The method of determining the X-ray BMD proved to be practical and effective, and it is a noninvasive technique. 3D micro-computed tomography revealed important information about bone porosity and bone volume between the two groups. The 3D images showed bone details that were not possible to visualize through radiographs. Thus it is a highly effective and detailed technique, but it requires patterning of all the samples in order to quantify the amounts properly. Statistical analysis showed no differences between the groups for bone volume parameters, degree of porosity and percentage of bone volume. However in the 3D images, it can be observed clearly larger amount of pores in the control samples in comparison to those with biomaterial. It is concluded from this study that the techniques of bone densitometry X-ray and 3D &micro;CT are very effective to evaluate bone healing in sheep. Bone mineral density was higher in limbs with biomaterial and there was a higher bone volume and lower degree of porosity in the samples with biomaterial compared to the control group

Page generated in 0.1006 seconds