• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Replication of mixing achieved in large co-rotating screw extruder using a novel laboratory 10-100g minimixer

Benkreira, Hadj, Patel, Rajnikant, Butterfield, R., Gale, Martin January 2008 (has links)
Yes / When compounding polymers with additives to develop materials at specifications (colouring plastics is the simplest example), the difficulties is in getting the formulation right the first time. Also, when developing completely new materials such as in nanotechnology applications, there is a need to do the initial trials safely and with as small quantities as possible to enable a wide range of experimentation. Wiith traditional applications, often the initial compounding formulation is done using small single or twin screw extruders but with machines that have a fair output to instruct the large scale operation. This step is costly in material wastage and time but more importantly it often does not provide the right formulation which in turn results in bigger wastage cost at the industrial scale before the right formulation is eventually obtained. With the very new material formulations, any reduction in cost of development is always essential. With these aims in mind, we have developed a new minimixer capable of handling tiny quantities of order 10-100g but the minimixer is capable of reproducing the very high mixing conditions experienced in large machines. This invention provides a new opportunity to develop new products quickly, safely and cheaply. The application is not restricted to polymers and can be extended to other soft materials. It has also other spin-offs as a research tool for studying mixing and developing new, more efficient, mixing flows. In this paper we explain the principle of operation we have engineered to produce such intense mixing. Basically, the device is based on combining two opposing flows: a single screw extruder circulation flow with a twin screw extruder mixing flow. The mixing is carried out as a batch but on its completion, the single screw extruder flow is reversed and becomes co-current with the twin extruder flow to enable the discharging of the batch through a die. In the paper we present mixing data obtained with various polymer-additive combinations tested in the minimixer under various conditions of screw speeds, mixing times and temperatures and at the larger scale to underpin the operation of this novel mixer. The quality of mixing of the extrudate was measured using a variety of methods depending on applications: using image analysis of microtome sections of the extrudate or of blown film samples produced from the formulations or measuring electrical properties.
2

Processing melt blended polymer nanocomposites using a novel laboratory mini-mixer : development of polymer nanocomposites in the melt phase using a novel mini-mixer

Khan, Atif Hussain January 2012 (has links)
Research into the processing conditions and parameters of polymeric nanocomposites has always been challenging to scientists and engineers alike. Many have developed tools and procedures to allow materials to be exploited and their properties improved with the addition of nanofillers to achieve the desired end material for various applications. Initial trials are mostly conducted using conventional small scale experiments using specialised equipment within the laboratory that can replicate the larger industrial equipment. This is a logical approach as it could save time and costs as many nanocomposites are relatively expensive to produce. Experiments have previously been done using the likes of the Haake twin screw extruder to manufacture nanocomposites within the laboratory but this research project has used a novel minimixer specifically developed to replicate mixing like large twin screw extrusion machines. The minimixer uses a twin paddle system for high shear mixing in conjunction with a single screw thus theoretically allowing an infinitely long recirculation. It is this ability to mix intensely whilst allowing for as long as desired recirculation which enables the replication in this very small mixer (10-30g capacity) of the mixing conditions in a large twin screw extruder. An added feature of the minimixer is that it can undertake inline data analysis in real time. The main experiments were conducted using a comprehensive DOE approach with several different factors being used including the temperature, screw speed, residence time, clay and compatibiliser loading and two polymer MFI's. The materials used included PP, Cloisite 20A, Polybond 3200, PET, Somasif MTE, Polyurethane 80A and Single / Multi-walled Carbon nanotubes. Detailed experimental results highlighted that rheological analysis of the nanocomposite materials as an initial testing tool were accurate in determining the Elastic and Loss modulus values together with the Creep and Recovery, Viscosity and Phase Angle properties in the molten state. This approach was also used in an additional set of experiments whereby the temperature, speed, residence time and compatibiliser were kept constant but the clay loading was increased in 1% wt. increments. These results showed that the G' & G'' values increased with clay loading. Another important finding was the bi-axial stretching step introduced after the processing stage of the nanocomposite materials which highlighted a further improvement in the modulus values using rheological testing. Other tests included using inline monitoring to look into both the viscosity and ultrasound measurements in real time of the molten polymer nanocomposite through a slit die attachment to the minimixer.
3

Processing melt blended polymer nanocomposites using a novel laboratory mini-mixer. Development of polymer nanocomposites in the melt phase using a novel mini-mixer.

Khan, Atif H. January 2012 (has links)
Research into the processing conditions and parameters of polymeric nanocomposites has always been challenging to scientists and engineers alike. Many have developed tools and procedures to allow materials to be exploited and their properties improved with the addition of nanofillers to achieve the desired end material for various applications. Initial trials are mostly conducted using conventional small scale experiments using specialised equipment within the laboratory that can replicate the larger industrial equipment. This is a logical approach as it could save time and costs as many nanocomposites are relatively expensive to produce. Experiments have previously been done using the likes of the Haake twin screw extruder to manufacture nanocomposites within the laboratory but this research project has used a novel minimixer specifically developed to replicate mixing like large twin screw extrusion machines. The minimixer uses a twin paddle system for high shear mixing in conjunction with a single screw thus theoretically allowing an infinitely long recirculation. It is this ability to mix intensely whilst allowing for as long as desired recirculation which enables the replication in this very small mixer (10-30g capacity) of the mixing conditions in a large twin screw extruder. An added feature of the minimixer is that it can undertake inline data analysis in real time. The main experiments were conducted using a comprehensive DOE approach with several different factors being used including the temperature, screw speed, residence time, clay and compatibiliser loading and two polymer MFI¿s. The materials used included PP, Cloisite 20A, Polybond 3200, PET, Somasif MTE, Polyurethane 80A and Single / Multi-walled Carbon nanotubes. Detailed experimental results highlighted that rheological analysis of the nanocomposite materials as an initial testing tool were accurate in determining the Elastic and Loss modulus values together with the Creep and Recovery, Viscosity and Phase Angle properties in the molten state. This approach was also used in an additional set of experiments whereby the temperature, speed, residence time and compatibiliser were kept constant but the clay loading was increased in 1% wt. increments. These results showed that the G¿ & G¿¿ values increased with clay loading. Another important finding was the bi-axial stretching step introduced after the processing stage of the nanocomposite materials which highlighted a further improvement in the modulus values using rheological testing. Other tests included using inline monitoring to look into both the viscosity and ultrasound measurements in real time of the molten polymer nanocomposite through a slit die attachment to the minimixer. / EPSRC

Page generated in 0.0192 seconds