• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Mixed Convection In Shallow Enclosures With A Series Of Heat Generating Components : A Numerical Study

Bhoite, Mayur Tarasing 06 1900 (has links) (PDF)
No description available.
2

Estudo do comportamento de ligações viga-pilar preenchido submetidas a ações cíclicas / Study on behavior of steel beam to CFT column connection subjected to cyclic loading

Kataoka, Marcela Novischi 28 June 2011 (has links)
No presente trabalho foi analisado o comportamento de ligações viga-pilar em estruturas mistas de aço e concreto com o auxílio de simulação numérica e experimentação. A simulação numérica foi realizada no programa DIANA, baseado no método dos Elementos Finitos. Os modelos de ligações analisados são compostos por ligações com parafusos passantes entre pilares metálicos preenchidos com concreto e vigas metálicas. A laje utilizada foi do tipo com fôrma de aço incorporada, com a utilização de conectores de cisalhamento para resistir aos esforços em conjunto com a viga. Para simular a situação de pilar intermediário, foram utilizados modelos com formato cruciforme, os quais foram submetidos à força cíclica reversível com a finalidade de submeter à estrutura a esforços semelhantes aos provocados por vento e sismo. Além do efeito da força cíclica, este trabalho avaliou também a influência na rigidez da ligação causada pela taxa de armadura da laje e pelo detalhe de ancoragem da armadura de continuidade ao pilar misto. Para isso foram ensaiados quatro modelos. Dentro da metodologia proposta, obteve-se numérica e experimentalmente, dados que permitiram a construção de curvas momento versus rotação e força versus deslocamento para a quantificação da rigidez e determinação da ductilidade da ligação. Como resultado das análises concluiu-se que a laje contribui mais na rigidez da ligação quando ela está submetida a momento fletor positivo e com relação ao método de ancoragem não houve diferença significativa nas rigidezes. / This research studied the behavior of beam-column connection in composite steel-concrete structures and was developed with the use of numerical simulation and experimentation. The numerical simulation was performed using the program DIANA which is based on the finite element method. The models are composed of connections with bolts passing through the concrete filled tube (CFT) column and steel beams with a steel deck. It was used shear connectors for the slab works together with the beam to resist the bend. To simulate the situation of the middle column, they are used models with cruciform form, which were subjected to reversible cyclic loading in order to bring structure the efforts similar to those caused by wind and earthquake. Besides the effect of cyclic loading, this research also evaluated the influence on the connection stiffness caused by the slab reinforcement ratio and anchors detail to the column of some bars. To obtain this information four models were tested. Within the proposed methodology numerical and experimental data were obtained which made possible the construction of moment versus rotation curves and loading versus displacement for the quantification of stiffness and ductility of the connections. The result of this research shows that the slab contributes more on the increase of stiffness when the connection is subjected to sagging moment and about the method of anchoring, there is no significant difference on stiffness between the two methods.
3

Estudo do comportamento de ligações viga-pilar preenchido submetidas a ações cíclicas / Study on behavior of steel beam to CFT column connection subjected to cyclic loading

Marcela Novischi Kataoka 28 June 2011 (has links)
No presente trabalho foi analisado o comportamento de ligações viga-pilar em estruturas mistas de aço e concreto com o auxílio de simulação numérica e experimentação. A simulação numérica foi realizada no programa DIANA, baseado no método dos Elementos Finitos. Os modelos de ligações analisados são compostos por ligações com parafusos passantes entre pilares metálicos preenchidos com concreto e vigas metálicas. A laje utilizada foi do tipo com fôrma de aço incorporada, com a utilização de conectores de cisalhamento para resistir aos esforços em conjunto com a viga. Para simular a situação de pilar intermediário, foram utilizados modelos com formato cruciforme, os quais foram submetidos à força cíclica reversível com a finalidade de submeter à estrutura a esforços semelhantes aos provocados por vento e sismo. Além do efeito da força cíclica, este trabalho avaliou também a influência na rigidez da ligação causada pela taxa de armadura da laje e pelo detalhe de ancoragem da armadura de continuidade ao pilar misto. Para isso foram ensaiados quatro modelos. Dentro da metodologia proposta, obteve-se numérica e experimentalmente, dados que permitiram a construção de curvas momento versus rotação e força versus deslocamento para a quantificação da rigidez e determinação da ductilidade da ligação. Como resultado das análises concluiu-se que a laje contribui mais na rigidez da ligação quando ela está submetida a momento fletor positivo e com relação ao método de ancoragem não houve diferença significativa nas rigidezes. / This research studied the behavior of beam-column connection in composite steel-concrete structures and was developed with the use of numerical simulation and experimentation. The numerical simulation was performed using the program DIANA which is based on the finite element method. The models are composed of connections with bolts passing through the concrete filled tube (CFT) column and steel beams with a steel deck. It was used shear connectors for the slab works together with the beam to resist the bend. To simulate the situation of the middle column, they are used models with cruciform form, which were subjected to reversible cyclic loading in order to bring structure the efforts similar to those caused by wind and earthquake. Besides the effect of cyclic loading, this research also evaluated the influence on the connection stiffness caused by the slab reinforcement ratio and anchors detail to the column of some bars. To obtain this information four models were tested. Within the proposed methodology numerical and experimental data were obtained which made possible the construction of moment versus rotation curves and loading versus displacement for the quantification of stiffness and ductility of the connections. The result of this research shows that the slab contributes more on the increase of stiffness when the connection is subjected to sagging moment and about the method of anchoring, there is no significant difference on stiffness between the two methods.

Page generated in 0.0879 seconds