• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • 1
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modeling and model based fault diagnosis of dry vacuum pumps in the semiconductor industry

Choi, Jae-Won, active 2013 11 February 2014 (has links)
Vacuum technology is ubiquitous in the high tech industries and scientific endeavors. Since vacuum pumps are critical to operation, semiconductor manufacturers desire reliable operations, ability to schedule downtime, and less costly maintenance services. To better cope with difficult maintenance issues, interests in novel fault diagnosis techniques are growing. This study concerns model based fault diagnosis and isolation (MB-FDI) of dry vacuum pumps in the semiconductor industry. Faults alter normal operation of a vacuum pump resulting in performance deviations, discovered by measurements. Simulations using an appropriate mathematical model with suitably chosen parameters can mimic faulty behavior. This research focuses on the construction of a detailed multi-stage dry vacuum pump model for MB-FDI, and the development of a simple and efficient FDI method to analyze common incipient faults such as particulate deposition and gas leak inside the pump. The pump model features 0-D thermo-fluid dynamics, scalable geometric representations of Roots blower, claw pumps and inter-stage port interfaces, a unified pipe model seamlessly connecting from free molecular to turbulent regimes, sophisticated internal leakage model considering true pump geometry and tribological aspects, and systematic assembly of a multi-stage configuration using single stage pump models. Design of a simple FDI technique for the dry vacuum pump includes staged fault simulations using faulty pump models, parametric study of faulty pump behaviors, and design of a health indicator based on classification. The main research contributions include the developments of an accurate multi-stage dry pump model with many features not found in existing pump models, and the design of a simple MB-FDI technique to detect and isolate the common faults found in dry vacuum pumps. The proposed dry pump model can pave the way for the future development of advanced MB-FDI methods, also performance improvement of existing dry vacuum pumps. The proposed fault classification charts can serve as a quick guideline for vacuum pump manufactures to isolate roots causes from faulty symptoms. / text
2

Analyse Structurelle pour le Diagnostic des Systèmes Distribués / Structural analysis for the diagnosis of distributed systems

Perez zuniga, Carlos gustavo 21 August 2017 (has links)
Les récents développements des systèmes technologiques ont mené à une complexification des comportements des systèmes actuels. Une solution pour gérer cette complexité croissante consiste à les considérer comme un ensemble de sous-systèmes hétérogènes et à développer des techniques distribuées pour les contrôler et les gérer. Cette solution soulève plusieurs problèmes. Tout d’abord, l’augmentation de la taille et du nombre de composants entraîne immanquablement l’augmentation du nombre de fautes qui peuvent conduire le système dans un état de défaillance critique. De fait, parmi les fonctions opérationnelles, les tâches de détection et d’isolation des fautes (Fault Detection and Isolation ou FDI), de maintenance et de réparation sont devenues prédominantes et elles influent considérablement sur le coût total des produits finaux.Cette thèse porte sur la détection et l’isolation de fautes. Parmi les différentes méthodes pour générer des tests de diagnostic utilisant la redondance analytique, cette thèse adopte l’approche par espace de parité qui utilise les relations de redondance analytique (RRA). Étant donné un modèle du système sous la forme d’un ensemble d’équations différentielles, les RRA sont des relations obtenues à partir du modèle en éliminant les variables non mesurées. Ceci peut être effectué dans un cadre analytique en utilisant la théorie de l’élimination. Une autre solution consiste à utiliser l’analyse structurelle. L’analyse structurelle est basée sur une abstraction du modèle qui ne conserve que les liens entre variables et équations. Malgré son apparente simplicité, l’analyse structurelle fournit un ensemble d’outils puissants, s’appuyant sur la théorie des graphes, pour analyser et inférer des informations sur le système. Par ailleurs, elle a l’avantage de s’appliquer indifféremment sur les systèmes linéaires ou non linéaires.L’objectif de cette thèse est de développer des techniques efficaces basées sur l’analyse structurelle pour le diagnostic des systèmes continus distribué. Dans ce cadre, le système se décompose en un ensemble de sous-systèmes en fonction de contraintes fonctionnelles, géographiques ou de confidentialité. La thèse se divise principalement en deux parties :• la première partie cherche à mettre à lumière, à partir des modèles structurels obtenus au niveau des sous-systèmes, les redondances qui généreront des tests de diagnostic pertinents au niveau du système global,• la deuxième partie vise à formuler et résoudre le problème d’optimisation lié au choix d’un sous-ensemble de tests de diagnostic au niveau des sous-systèmes permettant une diagnosticabilité maximale pour le système global.La première partie utilise le concept d’ensemble minimal structurellement surdéterminé guidé par les fautes (Fault-Driven Minimal Structurally Overdetermined Set ou FMSO set). Ce concept est introduit dans la thèse. Il s’agit d’un sousensemble d’équations du modèle avec une redondance minimale à partir de laquelle une RRA sensible à un ensemble de fautes peut être obtenu. Deux solutions pour générer des ensembles FMSO pour le système global sont présentées, d’une part dans un cadre décentralisé avec des superviseurs imbriqués suivant une hiérarchie; d’autre part dans un cadre totalement distribué. Ces solutions sont basées sur les propriétés des ensembles FMSO au niveau des sous-systèmes qui sont présentées dans la thèse. La deuxième partie pose un problème d’optimisation dans le cadre d’une recherche heuristique et propose trois solutions basées sur un algorithme A* itératif combiné avec une fonction capable d’évaluer si un ensemble FMSO au niveau global peut être obtenu à partir des ensembles FMSO locaux sélectionnés. Les concepts introduits dans la thèse et les résultats sont appliqués à deux cas d’étude industriels. Le premier est une usine de désalinisation. Le second est un système de détermination et de contrôle d’attitude pour un satellite en orbite basse. / The recent development of technological systems implies a high complexity of behaviors for today’s systems. An answer to the increased system’s complexity is to look at them as a multitude of heterogeneous subsystems and develop distributed techniques to control and manage them. This raises a number of problems. Firstly, as the size and number of components increase, so does the number of fault occurrences that may drive the system to undergo critical failures. Fault detection and isolation (FDI), maintenance and repair are an increasing part of the operational everyday’s tasks and they impact drastically the total cost of final products.This thesis focuses on fault detection and isolation. Among the different methods to generate diagnosis tests by taking advantage of analytical redundancy, this thesis adopts the so-called parity space approach based on analytical redundancy relations (ARRs). Given a model of the system in the form of a set of differential equations, ARRs are relations that are obtained from the model by eliminating non measured variables. This can be performed in an analytical framework using elimination theory but another way of doing this is to use structural analysis. Structural analysis is based on a structural abstraction of the model that only retains a representation of which variables are involved in which equations. Despite the rusticity of the abstract model, structural analysis provides a set of powerful tools, relying on graph theory, to analyze and infer information about the system. Interestingly, it applies indifferently to linear or nonlinear systems. The goal of this thesis is to develop effective techniques based on structural analysis for diagnosis of distributed continuous systems. In this framework, the system is decomposed into a set of subsystems according to functional, geographical or privacy constraints. The thesis is organized in two parts:• highlighting the redundancies that are built into the global structural model and that can be used to generate diagnosis tests starting from the redundancies existing in the subsystem’s models,• formulating and solving the optimization problem linked to the choice of a subset of diagnosis tests at the subsystems level that can lead to a set of diagnosis tests achieving maximum diagnosability for the global system.The first part takes benefit of the concept of Fault-Driven Minimal Structurally Overdetermined Set (FMSO set) that is introduced in the thesis. An FMSO set determines a subset of equations of the model with minimal redundancy from which an ARR sensitive to a set of faults can be obtained. Two solutions for generating FMSOs for the global system are presented, in a decentralized framework with supervisors at each level of a hierarchy and in a totally distributed framework.These are based on the properties of the FMSO sets for the subsystems in relation to those of the global system derived in the thesis.
3

Détection robuste et précoce des pannes oscillatoires dans les systèmes de commandes de vol

Simon, Pascal 07 December 2011 (has links)
Le travail de recherche effectué dans cette thèse a été réalisé dans le cadre d'une convention CIFRE entre le laboratoire IMS de l'université Bordeaux 1 et la société Airbus Operations S.A.S. Cette thèse traite de la détection robuste et précoce des pannes oscillatoires de faible amplitude dans les systèmes de commandes de vol électriques. Une panne oscillatoire est une oscillation anormale d'une surface de contrôle due à un dysfonctionnement dans la chaîne d'asservissement de la servocommande d'une gouverne. Les pannes oscillatoires ont une influence sur la structure, l'aéroélasticité et la pilotabilité de l'avion, lorsqu'ils sont situés dans la bande passante de l'actionneur. La capacité à détecter ces pannes est très importante car elles ont un impact sur la conception structurale de l'avion. Au plan méthodologique, nous nous sommes focalisés sur l'estimation adaptative des paramètres et de l'état à base d'une technique de filtrage non linéaire local. Le mécanisme de filtrage opère sur un modèle non linaire de la chaine de contrôle-commande de l’actionneur hydraulique en amont des surfaces de contrôle. L'algorithme d'estimation est basé sur une interpolation polynomiale d'opérateurs linéaire, et offre l'avantage d'une implémentation relativement aisée. Un problème crucial et sous-jacent est la détermination des hyper-paramètres de réglage de cet algorithme. Nous avons proposé une démarche hors-ligne dédiée, en intégrant un critère de sensibilité vis-à-vis des pannes que nous devons détecter. La technique proposée a été implémentée et testée: les résultats expérimentaux obtenus sur banc essai et sur un simulateur A380 ont clairement mis en évidence l'apport de la nouvelle approche en termes de performances, tout en gardant le même niveau de robustesse. / The research work done in this PhD has been caried out in the frame of an industrial convention (CIFRE) between the IMS laboratory and Airbus Operations S.A.S. The thesis deals with robust and early detection of oscillatory failures (OFC: Oscillatory Failure Case) in the Electrical Flight Control System. An oscillatory failure is an abnormal oscillation of a control surface due to component malfunction in control surface servoloops. OFCs have an influence on structural loads, aeroelasticity and controllability when located within the actuator bandwidth. The ability to detect these failures is very important because they have an impact on the structural design of the aircraft. Usual monitoring techniques cannot always guarantee to remain within an envelope with acceptable robustness. In this work, we develop a model based strategy to detect such failures with small amplitude at a very early stage. The monitoring strategy is based on dedicated non linear local filtering for on-line joint parameter/state estimation, allowing for model parameter variations during A/C flight. This strategy is associated with the same decision making rules as currently used for in-service Airbus A380. We propose a method for adjusting the tuning parameters so that various design goals and trades-off can be easily formulated and managed. The performance of the proposed fault detection scheme is measured by its detection delay, its propensity to issue false alarms and whether it permits a failure to go undetected. The proposed technique has been implemented and tested with success on Airbus test facilities including an A380 flight simulator.
4

Fault Diagnosis for Functional Safety in Electrified and Automated Vehicles

Li, Tianpei 25 September 2020 (has links)
No description available.
5

Model-Based Fault Diagnosis For Automotive Functional Safety

Zhang, Jiyu January 2016 (has links)
No description available.

Page generated in 0.1 seconds