• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Instalação e capacidade de carga axial de estacas modelo fluidizadas em solos arenosos / Installation and axial load capacity of fluidized model piles in sandy soils

Passini, Larissa de Brum January 2015 (has links)
O objetivo desta tese foi verificar a viabilidade de utilização de jatos de água verticais circulares, únicos e contínuos, provenientes da ponteira de uma estaca torpedo, para auxiliar sua instalação por peso próprio no leito marinho, através da fluidização do solo. Foram realizados ensaios de laboratório, em modelo reduzido, utilizando hastes para simular estacas torpedo (sem aletas) seguindo a lei de semelhança pelo número de Froude. Os ensaios de instalação por peso próprio, com e sem fluidização, ocorreram sem altura de queda, com a estaca modelo em contato com a superfície do leito. Trabalhou-se com três diâmetros de estacas, seis massas, quatros vazões e areia fina saturada compactada em duas densidades relativas iniciais (média e densa). Os ensaios de arrancamento, em leito arenoso fluidizado e não fluidizado, foram realizados imediatamente, 4, 24 e 48 horas após a instalação dos modelos. A metodologia de instalação proposta mostrou-se viável, quando o jateamento é aplicado desde a superfície em solo arenoso. As profundidades instaladas atingidas por fluidização (L/de > 50) foram consideravelmente superiores às profundidades cravadas por apenas peso próprio (L/de < 5). A geometria da zona perturbada durante a instalação por fluidização dos modelos, permaneceu constante e paralela ao fuste, com geometria de aproximadamente 2de em relação ao modelo, independentemente da vazão aplicada e da densidade relativa inicial do solo. A partir das leis de análise dimensional, uma expressão para a profundidade instalada das estacas modelo foi proposta, mostrando que a mesma é função do peso e da geometria do modelo, das propriedades físicas do solo e do fluido, e de sua vazão. Quanto maior a massa do modelo e a vazão aplicada e menor a densidade relativa, maior a profundidade atingida e maior a velocidade inicial de instalação. Constatou-se que a capacidade de carga axial dos modelos depende da densidade relativa, do diâmetro do modelo e do método de instalação (com e sem fluidização). Independentemente da densidade relativa inicial, o solo fluidizado convergiu para a mesma densidade relativa final, próxima as suas condições no estado crítico. As estacas em solo fluidizado apresentaram ganho resistência com o tempo (efeito de setup), com capacidade de carga inferior às estacas cravadas em solo não fluidizado. / The aim of this thesis was to investigate the feasibility of using circular vertical water jets, single and continuous, from the tip of a torpedo pile, to assist its installation by own weight on the seabed, through soil fluidization. Laboratory model tests were carried out, using tubes to simulate torpedo piles (without wings) following the law of similarity defined by the Froude number. The installation tests by the pile own weight, with and without fluidization, occurred without drop height, with the piles in contact with the surface of the bed. Three diameters of model piles and six masses, four flow rates and saturated sand at two initial relative densities (medium and dense) have been used in this set of experiments. Pullout tests in fluidized and nonfluidized soils were performed immediately, 4, 24 and 48 hours after the installation of the models. The proposed installation methodology proved to be feasible when the fluidization is applied from the surface in sandy soils. The installation depths achieved by fluidization (L/de > 50) were significantly higher than the depths reached by pile own weight (L/de < 5). The geometry of the perturbed zone during model installation by fluidization remained constant and parallel to the shaft in a geometry of about 2de of the pile model, regardless of the applied flow rate and the initial relative density of the soil. Following the laws of dimensional analysis, an expression for the embedment of fluidized piles is derived, showing that the penetration depth is a function of pile weight and geometry, fluidized water jet flow rate and velocity, as well as the soil and fluid properties. Increasing the model mass and fluidized flow rate and decreasing the relative density leads to an increase in the depth reached and the initial speed of installation. The axial load capacity of the models depends on the soil relative density, piles diameter and installation method (with and without fluidization). Regardless the initial relative density, the fluidized soil converged to the same final relative density, near its conditions of critical state. Piles installed in fluidized soil presented gain of axial capacity over time (setup effect) with lower resistance than piles driven in nonfluidized soil.
2

Instalação e capacidade de carga axial de estacas modelo fluidizadas em solos arenosos / Installation and axial load capacity of fluidized model piles in sandy soils

Passini, Larissa de Brum January 2015 (has links)
O objetivo desta tese foi verificar a viabilidade de utilização de jatos de água verticais circulares, únicos e contínuos, provenientes da ponteira de uma estaca torpedo, para auxiliar sua instalação por peso próprio no leito marinho, através da fluidização do solo. Foram realizados ensaios de laboratório, em modelo reduzido, utilizando hastes para simular estacas torpedo (sem aletas) seguindo a lei de semelhança pelo número de Froude. Os ensaios de instalação por peso próprio, com e sem fluidização, ocorreram sem altura de queda, com a estaca modelo em contato com a superfície do leito. Trabalhou-se com três diâmetros de estacas, seis massas, quatros vazões e areia fina saturada compactada em duas densidades relativas iniciais (média e densa). Os ensaios de arrancamento, em leito arenoso fluidizado e não fluidizado, foram realizados imediatamente, 4, 24 e 48 horas após a instalação dos modelos. A metodologia de instalação proposta mostrou-se viável, quando o jateamento é aplicado desde a superfície em solo arenoso. As profundidades instaladas atingidas por fluidização (L/de > 50) foram consideravelmente superiores às profundidades cravadas por apenas peso próprio (L/de < 5). A geometria da zona perturbada durante a instalação por fluidização dos modelos, permaneceu constante e paralela ao fuste, com geometria de aproximadamente 2de em relação ao modelo, independentemente da vazão aplicada e da densidade relativa inicial do solo. A partir das leis de análise dimensional, uma expressão para a profundidade instalada das estacas modelo foi proposta, mostrando que a mesma é função do peso e da geometria do modelo, das propriedades físicas do solo e do fluido, e de sua vazão. Quanto maior a massa do modelo e a vazão aplicada e menor a densidade relativa, maior a profundidade atingida e maior a velocidade inicial de instalação. Constatou-se que a capacidade de carga axial dos modelos depende da densidade relativa, do diâmetro do modelo e do método de instalação (com e sem fluidização). Independentemente da densidade relativa inicial, o solo fluidizado convergiu para a mesma densidade relativa final, próxima as suas condições no estado crítico. As estacas em solo fluidizado apresentaram ganho resistência com o tempo (efeito de setup), com capacidade de carga inferior às estacas cravadas em solo não fluidizado. / The aim of this thesis was to investigate the feasibility of using circular vertical water jets, single and continuous, from the tip of a torpedo pile, to assist its installation by own weight on the seabed, through soil fluidization. Laboratory model tests were carried out, using tubes to simulate torpedo piles (without wings) following the law of similarity defined by the Froude number. The installation tests by the pile own weight, with and without fluidization, occurred without drop height, with the piles in contact with the surface of the bed. Three diameters of model piles and six masses, four flow rates and saturated sand at two initial relative densities (medium and dense) have been used in this set of experiments. Pullout tests in fluidized and nonfluidized soils were performed immediately, 4, 24 and 48 hours after the installation of the models. The proposed installation methodology proved to be feasible when the fluidization is applied from the surface in sandy soils. The installation depths achieved by fluidization (L/de > 50) were significantly higher than the depths reached by pile own weight (L/de < 5). The geometry of the perturbed zone during model installation by fluidization remained constant and parallel to the shaft in a geometry of about 2de of the pile model, regardless of the applied flow rate and the initial relative density of the soil. Following the laws of dimensional analysis, an expression for the embedment of fluidized piles is derived, showing that the penetration depth is a function of pile weight and geometry, fluidized water jet flow rate and velocity, as well as the soil and fluid properties. Increasing the model mass and fluidized flow rate and decreasing the relative density leads to an increase in the depth reached and the initial speed of installation. The axial load capacity of the models depends on the soil relative density, piles diameter and installation method (with and without fluidization). Regardless the initial relative density, the fluidized soil converged to the same final relative density, near its conditions of critical state. Piles installed in fluidized soil presented gain of axial capacity over time (setup effect) with lower resistance than piles driven in nonfluidized soil.
3

Instalação e capacidade de carga axial de estacas modelo fluidizadas em solos arenosos / Installation and axial load capacity of fluidized model piles in sandy soils

Passini, Larissa de Brum January 2015 (has links)
O objetivo desta tese foi verificar a viabilidade de utilização de jatos de água verticais circulares, únicos e contínuos, provenientes da ponteira de uma estaca torpedo, para auxiliar sua instalação por peso próprio no leito marinho, através da fluidização do solo. Foram realizados ensaios de laboratório, em modelo reduzido, utilizando hastes para simular estacas torpedo (sem aletas) seguindo a lei de semelhança pelo número de Froude. Os ensaios de instalação por peso próprio, com e sem fluidização, ocorreram sem altura de queda, com a estaca modelo em contato com a superfície do leito. Trabalhou-se com três diâmetros de estacas, seis massas, quatros vazões e areia fina saturada compactada em duas densidades relativas iniciais (média e densa). Os ensaios de arrancamento, em leito arenoso fluidizado e não fluidizado, foram realizados imediatamente, 4, 24 e 48 horas após a instalação dos modelos. A metodologia de instalação proposta mostrou-se viável, quando o jateamento é aplicado desde a superfície em solo arenoso. As profundidades instaladas atingidas por fluidização (L/de > 50) foram consideravelmente superiores às profundidades cravadas por apenas peso próprio (L/de < 5). A geometria da zona perturbada durante a instalação por fluidização dos modelos, permaneceu constante e paralela ao fuste, com geometria de aproximadamente 2de em relação ao modelo, independentemente da vazão aplicada e da densidade relativa inicial do solo. A partir das leis de análise dimensional, uma expressão para a profundidade instalada das estacas modelo foi proposta, mostrando que a mesma é função do peso e da geometria do modelo, das propriedades físicas do solo e do fluido, e de sua vazão. Quanto maior a massa do modelo e a vazão aplicada e menor a densidade relativa, maior a profundidade atingida e maior a velocidade inicial de instalação. Constatou-se que a capacidade de carga axial dos modelos depende da densidade relativa, do diâmetro do modelo e do método de instalação (com e sem fluidização). Independentemente da densidade relativa inicial, o solo fluidizado convergiu para a mesma densidade relativa final, próxima as suas condições no estado crítico. As estacas em solo fluidizado apresentaram ganho resistência com o tempo (efeito de setup), com capacidade de carga inferior às estacas cravadas em solo não fluidizado. / The aim of this thesis was to investigate the feasibility of using circular vertical water jets, single and continuous, from the tip of a torpedo pile, to assist its installation by own weight on the seabed, through soil fluidization. Laboratory model tests were carried out, using tubes to simulate torpedo piles (without wings) following the law of similarity defined by the Froude number. The installation tests by the pile own weight, with and without fluidization, occurred without drop height, with the piles in contact with the surface of the bed. Three diameters of model piles and six masses, four flow rates and saturated sand at two initial relative densities (medium and dense) have been used in this set of experiments. Pullout tests in fluidized and nonfluidized soils were performed immediately, 4, 24 and 48 hours after the installation of the models. The proposed installation methodology proved to be feasible when the fluidization is applied from the surface in sandy soils. The installation depths achieved by fluidization (L/de > 50) were significantly higher than the depths reached by pile own weight (L/de < 5). The geometry of the perturbed zone during model installation by fluidization remained constant and parallel to the shaft in a geometry of about 2de of the pile model, regardless of the applied flow rate and the initial relative density of the soil. Following the laws of dimensional analysis, an expression for the embedment of fluidized piles is derived, showing that the penetration depth is a function of pile weight and geometry, fluidized water jet flow rate and velocity, as well as the soil and fluid properties. Increasing the model mass and fluidized flow rate and decreasing the relative density leads to an increase in the depth reached and the initial speed of installation. The axial load capacity of the models depends on the soil relative density, piles diameter and installation method (with and without fluidization). Regardless the initial relative density, the fluidized soil converged to the same final relative density, near its conditions of critical state. Piles installed in fluidized soil presented gain of axial capacity over time (setup effect) with lower resistance than piles driven in nonfluidized soil.

Page generated in 0.0653 seconds