• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento e análise da eficácia de guia cirúrgico paciente-específico produzido por impressão 3D para aplicação de pinos transarticulares atlantoaxiais em cães miniatura / Development and efficacy assessment of a patientspecific 3d-printed surgical guide for implantation of atlantoaxial transarticular pin fixation in miniature dogs

Monteiro, Bianca Fiuza 07 June 2018 (has links)
A subluxação atlantoaxial em cães miniatura culmina em compressão da medula espinhal e mielopatia cervical de graus variáveis. Frequentemente o tratamento cirúrgico se faz necessário, sendo os implantes transarticulares uma das opções terapêuticas. Convencionalmente a passagem desses implantes baseia-se em pontos anatômicos de referência e ângulos genéricos preestabelecidos, todavia, devido ao estreito corredor ósseo o posicionamento ideal é desafiador. O desenvolvimento de métodos de planejamento cirúrgico individualizados poderia aumentar a acurácia na aplicação de implantes atlantoaxiais. O presente estudo teve como objetivo desenvolver um guia cirúrgico paciente-específico (GCPE) para colocação de pinos atlantoaxiais em cães miniaturas e comparar a eficácia desses dispositivos em relação a técnica cirúrgica convencional. Para tanto, dezesseis cadáveres de cães de até seis quilogramas foram dispostos aleatoriamente em dois grupos de oito cães, para serem submetidos a cirurgia de estabilização transarticular atlantoaxial com pinos lisos de 1,6 mm. Nos cães do Grupo A (GrA) a aplicação dos pinos foi guiada por um GCPE, desenvolvido com base em imagens de tomografia computadorizada (TC), a partir de técnicas de prototipagem rápida e impressão 3D por modelagem por fusão e deposição. Os cães do Grupo B (GrB), foram submetidos ao procedimento operatório convencional, sendo a passagem dos pinos guiada por referências anatômicas. Posteriormente ambos os grupos foram submetidos à exame de TC para avaliação da acurácia dos pinos. Para a avaliação do posicionamento dos implantes criou-se uma escala que ponderou a manutenção nos corredores seguros e os classificou de acordo com a estabilidade oferecida e a segurança da aplicação. Observou-se que não houve diferença significativa entre o método com GCPE e a cirurgia convencional, sendo que ambos grupos tiveram resultados expressivos de pinos inadequadamente aplicados, incluindo violação de corticais com obliteração do forame vertebral em 3 (37,5%) cães do GrA e 4 (50%) cães do GrB e obliteração do forame transverso em 3 (37,5%) animais do GrA e 1 (12,5%) do GrB. A aplicação de pinos em posição adequada bilateralmente foi observada em apenas 2 (25%) cães de cada grupo. Concluímos que a confecção de um GCPE para pinos transarticulares em cães miniaturas é viável, todavia, o modelo criado não foi capaz de aumentar a eficácia e segurança da cirurgia em relação à técnica convencional. / The atlantoaxial subluxation in miniature dogs leads to spinal cord compression and cervical myelopathy in several degrees. Commonly the surgical treatment is necessary, and one of therapeutic options are the transarticular fixation. Conventionally the passage of these implants is based on anatomical reference points and generics pre-established angles, however, due to the narrow bony corridor the ideal positioning is challenging. The development of individual surgical planning methods could improve the accuracy of atlantoaxial implants application. The present study aimed to develop a patient-specific surgical guide (PSSG) for placement of atlantoaxial pins in miniature dogs and to compare the efficacy of these devices related to the conventional surgical technique. Sixteen cadavers of dogs, up to six kilograms, were randomly placed in two groups of eight dogs each, to undergo atlantoaxial transarticular stabilization with Kirschner wires. On the Group A (GrA) the application of Kirschner wire were guided by a PSSG, developed based on computed tomography (CT) images, using rapid prototyping and fused deposition modeling 3D impression technique. The dogs of Group B (GrB) were submitted to conventional procedure, with the passage of the Kirschner wires guided by anatomical references. After surgeries, dogs in both groups were submitted to a CT scan to evaluate the accuracy of the implants. To evaluate the implants position a scale was created and considered the maintenance of the pins in the safe corridors and classified them according to the stability and safety of the application. It was observed that there was no significant difference between the PSSG method and the conventional surgery, and that both groups had expressive results of inappropriately applied pins, including obliteration of vertebral foramen in 3 (37.5%) dogs from GrA and 4 (50%) dogs from GrB and obliteration of the transverse foramen in 3 (37.5%) dogs from GrA and 1 (12, 5%) dog of GrB. The bilaterally application of pins in a suitable position was observed in only 2 (25%) dogs of each group. We concluded that the development of a PSSG for transarticular pins in miniature dogs is feasible, however, the model that we design was not able to increase the efficacy and safety of the surgery, compared to the conventional surgical technique.
2

Elaboração de protocolo de ensaios mecânicos para avaliação da performance do material PLA através da manufatura aditiva por meio do processo FDM / Preparation of mechanical test protocol for evaluation of pla material performance through additive manufacturing by fdm process

Branco, Rodolfo Ramos Castelo 19 December 2016 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2018-05-24T14:11:32Z No. of bitstreams: 1 PDF - Rodolfo Ramos Castelo Branco.pdf: 33386528 bytes, checksum: d16a1c9b6b747be04f2968cf6f66ceaf (MD5) / Approved for entry into archive by Secta BC (secta.csu.bc@uepb.edu.br) on 2018-06-05T11:33:25Z (GMT) No. of bitstreams: 1 PDF - Rodolfo Ramos Castelo Branco.pdf: 33386528 bytes, checksum: d16a1c9b6b747be04f2968cf6f66ceaf (MD5) / Made available in DSpace on 2018-06-05T11:33:25Z (GMT). No. of bitstreams: 1 PDF - Rodolfo Ramos Castelo Branco.pdf: 33386528 bytes, checksum: d16a1c9b6b747be04f2968cf6f66ceaf (MD5) Previous issue date: 2016-12-19 / Technological innovation has been a constant in several areas in the contemporary world, emphasizing in the areas of engineering and health. In this scenario, there is the Additive Manufacturing (MA), which consists of a manufacturing process using the addition of material in successive flat layers, in which it is possible to generate 3D physical parts obtained directly from CAD (Computer Aided Design). The MA is divided into several processes, in this study it will be highlighted by Fusion and Deposition Modeling (FDM) of the solids class, which uses solid polymer coils, especially Poly lactic acid (PLA). This technology of manufacturing process has been gaining more and more prominence in the technological scenario, with which it is possible to affirm that the Additive Manufacturing is on a scale of growth, being considered by many scholars as the new industrial revolution, which obviously opens space for New research in the area, thus necessitating the consolidation of processes, machinery and materials. In this context of recognition of the participation that the Additive Manufacturing process has been achieving, this study aimed to elaborate mechanical testing protocols for the evaluation of PLA material performance through the MA from the FDM process. The applied methodology was based on studying the parameters of construction of the pieces in FDM (structure, raster, deposition rate, temperature, loops, orientation of the raster angle, position orientation of the pieces, among others), to perform the mechanical tests of the Type and analyze the results obtained through strain-strain graphs (maximum tensions, rupture and modulus of elasticity). The result obtained evidenced little difference between the deposition rates (20%, 50% and 100%) regarding the construction time. Regarding the mechanical properties, the pieces with 100% fill characteristics in their internal structure presented better tensions. It was also observed the influence of the position of construction of the specimens in the printing tray, changing its mechanical characteristics. / A inovação tecnológica tem sido uma constante em diversas áreas no mundo contemporâneo, destacando-se nas áreas de engenharia e saúde. Neste cenário, encontra-se a Manufatura Aditiva (MA), que consiste em um processo de fabricação utilizando a adição de material em camadas planas sucessivas, no qual é possível gerar peças físicas em 3D, obtidas diretamente de arquivos de modelagem CAD (Computer Aided Design). A MA divide-se em vários processos, neste estudo será destacado por Modelagem de fusão e deposição (FDM) da classe dos sólidos, o qual utiliza bobinas de polímeros sólidos, especialmente o Poli ácido láctico (PLA). Esta tecnologia de processo de fabricação vem ganhando cada vez mais destaque no cenário tecnológico, com isso é possível afirmar que a Manufatura aditiva se encontra em uma escala de crescimento, sendo considerada por muitos estudiosos como a nova revolução industrial, o que obviamente abre espaço para novas pesquisas na área, havendo assim a necessidade da consolidação dos processos, máquinas e materiais. Neste contexto de reconhecimento da participação que o processo de Manufatura Aditiva vem alcançando, este estudo visou elaborar protocolos de ensaios mecânicos para avaliação de performance do material PLA através da MA a partir do processo FDM. A metodologia aplicada baseou-se em estudar os parâmetros de construção das peças em FDM (estrutura, raster, taxa de deposição, temperatura, loops, orientação do ângulo raster, orientação da posição das peças, dentre outros), em realizar os ensaios mecânicos do tipo tração e analisar os resultados obtidos através dos gráficos de tensão-deformação (tensões máxima, ruptura e modulo de elasticidade). O resultado obtido evidenciou pouca diferença entre as taxas de deposição (20%, 50% e 100%) no tocante ao tempo de construção. Em relação as propriedades mecânicas, as peças de características 100% de preenchimento em sua estrutura interna apresentaram melhores tensões. Observou-se também, a influência da posição de construção dos corpos de prova na bandeja de impressão, alterando suas características mecânicas.

Page generated in 0.0909 seconds