• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicação de algoritmos bio-inspirados na parametrização dos controladores suplementares de amortecimento e dispositivo FACTS UPFC /

Martins, Luís Fabiano Barone. January 2017 (has links)
Orientador: Percival Bueno de Araujo / Resumo: Neste trabalho são apresentados quatro métodos de otimização bio-inspirados, Colônia de Abelhas Artificiais, Otimização por Enxame de Partículas, Algoritmo dos Vagalumes e um híbrido aqui denominado por Bee – PSO, que combina particularidades dos outros três. Estes métodos são utilizados no ajuste coordenado dos parâmetros dos controladores Proporcional-Integral e Suplementares de Amortecimento (Estabilizadores de Sistemas de Potência e o conjunto Unified Power Flow Controller – Power Oscillation Damping). O objetivo é inserir amortecimento adicional aos modos oscilatórios de baixa frequência e, consequentemente, garantir a estabilidade do sistema elétrico frente a pequenas perturbações. São considerados três cenários que englobam duas configurações de instalação dos controladores suplementares e duas condições de carregamento, uma fixa e outra variável. Uma formulação por injeções de corrente do dispositivo Unified Power Flow Controller é sugerida e incorporada ao Modelo de Sensibilidade de Corrente, utilizado para representar o sistema elétrico de potência. Análises estática e dinâmica foram realizadas nos sistemas teste Simétrico de Duas Áreas e New England para validar o modelo de injeções de corrente proposto para o Unified Power Flow Controller e determinar qual dos algoritmos apresentados é o mais eficiente no ajuste coordenado dos parâmetros dos controladores. Dos resultados obtidos foi possível concluir que a versão híbrida proposta neste trabalho possui desempenho s... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this work four bio-inspired optimization methods, Artificial Bee Colony, Particle Swarm Optimization, Firefly Algorithm, and a hybrid called Bee – PSO, which combines the characteristics of the other three are presented. These methods are used in the coordinated adjustment of the parameters of Proportional-Integral and Supplementary Damping Controllers (Power System Stabilizers and the Unified Power Flow Controller - Power Oscillation Damping). The goal is to insert additional damping into the low-frequency oscillatory modes and thus ensure the stability of the electrical system against minor disturbances. Three scenarios are considered that include two installation configurations of the supplementary controllers and two charging conditions, one fixed and one variable. A current injection formulation of the Unified Power Flow Controller is suggested and incorporated into the Current Sensitivity Model used to represent the electric power system. Static and dynamic analyzes were performed in the Two-Zone Symmetric and New England test systems to validate the proposed current injection model for the Unified Power Flow Controller and to determine which of the presented algorithms is the most efficient in the coordinated adjustment of the parameters of the controllers. From the results obtained it was possible to conclude that the hybrid version proposed in this work has superior performance in most scenarios analyzed, providing solutions with sufficient damping, even when smal... (Complete abstract click electronic access below) / Doutor
2

Aplicação de algoritmos bio-inspirados na parametrização dos controladores suplementares de amortecimento e dispositivo FACTS UPFC / Application of bio-inspired algorithms in the parametrization of supplementary damping controllers and UPFC FACTS device

Martins, Luís Fabiano Barone [UNESP] 22 August 2017 (has links)
Submitted by LUIS FABIANO BARONE MARTINS null (luis_barone@ig.com.br) on 2017-08-30T14:29:52Z No. of bitstreams: 1 tese-luis-fabiano-barone-martins.pdf: 3400963 bytes, checksum: 6361e93ee21ab8eb5a35cb9dd7d0bd28 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-08-30T17:52:14Z (GMT) No. of bitstreams: 1 martins_lfb_dr_ilha.pdf: 3400963 bytes, checksum: 6361e93ee21ab8eb5a35cb9dd7d0bd28 (MD5) / Made available in DSpace on 2017-08-30T17:52:14Z (GMT). No. of bitstreams: 1 martins_lfb_dr_ilha.pdf: 3400963 bytes, checksum: 6361e93ee21ab8eb5a35cb9dd7d0bd28 (MD5) Previous issue date: 2017-08-22 / Neste trabalho são apresentados quatro métodos de otimização bio-inspirados, Colônia de Abelhas Artificiais, Otimização por Enxame de Partículas, Algoritmo dos Vagalumes e um híbrido aqui denominado por Bee – PSO, que combina particularidades dos outros três. Estes métodos são utilizados no ajuste coordenado dos parâmetros dos controladores Proporcional-Integral e Suplementares de Amortecimento (Estabilizadores de Sistemas de Potência e o conjunto Unified Power Flow Controller – Power Oscillation Damping). O objetivo é inserir amortecimento adicional aos modos oscilatórios de baixa frequência e, consequentemente, garantir a estabilidade do sistema elétrico frente a pequenas perturbações. São considerados três cenários que englobam duas configurações de instalação dos controladores suplementares e duas condições de carregamento, uma fixa e outra variável. Uma formulação por injeções de corrente do dispositivo Unified Power Flow Controller é sugerida e incorporada ao Modelo de Sensibilidade de Corrente, utilizado para representar o sistema elétrico de potência. Análises estática e dinâmica foram realizadas nos sistemas teste Simétrico de Duas Áreas e New England para validar o modelo de injeções de corrente proposto para o Unified Power Flow Controller e determinar qual dos algoritmos apresentados é o mais eficiente no ajuste coordenado dos parâmetros dos controladores. Dos resultados obtidos foi possível concluir que a versão híbrida proposta neste trabalho possui desempenho superior na maioria dos cenários analisados, fornecendo soluções com amortecimento suficiente, mesmo quando pequenas variações no carregamento do sistema são consideradas. / In this work four bio-inspired optimization methods, Artificial Bee Colony, Particle Swarm Optimization, Firefly Algorithm, and a hybrid called Bee – PSO, which combines the characteristics of the other three are presented. These methods are used in the coordinated adjustment of the parameters of Proportional-Integral and Supplementary Damping Controllers (Power System Stabilizers and the Unified Power Flow Controller - Power Oscillation Damping). The goal is to insert additional damping into the low-frequency oscillatory modes and thus ensure the stability of the electrical system against minor disturbances. Three scenarios are considered that include two installation configurations of the supplementary controllers and two charging conditions, one fixed and one variable. A current injection formulation of the Unified Power Flow Controller is suggested and incorporated into the Current Sensitivity Model used to represent the electric power system. Static and dynamic analyzes were performed in the Two-Zone Symmetric and New England test systems to validate the proposed current injection model for the Unified Power Flow Controller and to determine which of the presented algorithms is the most efficient in the coordinated adjustment of the parameters of the controllers. From the results obtained it was possible to conclude that the hybrid version proposed in this work has superior performance in most scenarios analyzed, providing solutions with sufficient damping, even when small variations in system loading are considered.
3

Aplicação do algoritmo genético de Chu-Beasley especializado no ajuste dos parâmetros dos controladores suplementares e dispositivo FACTS IPFC / Application of the specialized Chu-Beasley's genetic algorithm for adjusting the parameters of supplementary controllers and the IPFC FACTS device

Fortes, Elenilson de Vargas [UNESP] 21 October 2016 (has links)
Submitted by ELENILSON DE VARGAS FORTES null (vargasfortes@yahoo.com.br) on 2016-10-27T22:01:08Z No. of bitstreams: 1 Tese.pdf: 4090366 bytes, checksum: c721654fbc082e717b79dc074adcbfa0 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-11-03T18:32:27Z (GMT) No. of bitstreams: 1 fortes_ev_dr_ilha.pdf: 4090366 bytes, checksum: c721654fbc082e717b79dc074adcbfa0 (MD5) / Made available in DSpace on 2016-11-03T18:32:27Z (GMT). No. of bitstreams: 1 fortes_ev_dr_ilha.pdf: 4090366 bytes, checksum: c721654fbc082e717b79dc074adcbfa0 (MD5) Previous issue date: 2016-10-21 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este trabalho apresenta o Algoritmo Genético de Chu-Beasley Especializado para realizar o ajuste coordenado dos parâmetros de controladores Proporcional-Integral e suplementares de amortecimento (Estabilizadores de Sistemas de Potência e Interline Power Flow Controller - Power Oscillation Damping) em sistemas elétricos de potência multimáquinas. O objetivo principal deste trabalho é inserir amortecimento adicional às oscilações eletromecânicas de baixa frequência classificadas como local e interárea. Para representar o sistema, é utilizado o Modelo de Sensibilidade de Corrente. Desse modo, todos os seus dispositivos e componentes foram modelados por injeção de corrente e, portanto, um novo modelo de injeção de corrente para o Interline Power Flow Controller é apresentado. Três sistemas teste foram utilizados nas simulações realizadas neste trabalho, sendo: Simétrico de Duas Áreas, New England e o Sul Brasileiro Reduzido. O desempenho da metodologia proposta (Algoritmo Genético de Chu-Beasley Especializado), no que concerne ao ajuste dos parâmetros dos controladores, foi comparado a outros dois algoritmos bastantes difundidos na literatura: Particle Swarm Optimization e o Algoritmo Genético com Elitismo. Os resultados demonstraram que o algoritmo Genético de Chu-Beasley Especializado foi mais eficiente que as demais técnicas apresentadas, obtendo soluções robustas quando variações de cargas foram consideradas, sendo, portanto, credenciado como ferramenta no estudo da análise da estabilidade a pequenas perturbações. / CNPq: 141084/2016-2
4

Aplicação do algoritmo genético de Chu-Beasley especializado no ajuste dos parâmetros dos controladores suplementares e dispositivo FACTS IPFC /

Fortes, Elenilson de Vargas January 2016 (has links)
Orientador: Percival Bueno de Araujo / Resumo: Este trabalho apresenta o Algoritmo Genético de Chu-Beasley Especializado para realizar o ajuste coordenado dos parâmetros de controladores Proporcional-Integral e suplementares de amortecimento (Estabilizadores de Sistemas de Potência e Interline Power Flow Controller - Power Oscillation Damping) em sistemas elétricos de potência multimáquinas. O objetivo principal deste trabalho é inserir amortecimento adicional às oscilações eletromecânicas de baixa frequência classificadas como local e interárea. Para representar o sistema, é utilizado o Modelo de Sensibilidade de Corrente. Desse modo, todos os seus dispositivos e componentes foram modelados por injeção de corrente e, portanto, um novo modelo de injeção de corrente para o Interline Power Flow Controller é apresentado. Três sistemas teste foram utilizados nas simulações realizadas neste trabalho, sendo: Simétrico de Duas Áreas, New England e o Sul Brasileiro Reduzido. O desempenho da metodologia proposta (Algoritmo Genético de Chu-Beasley Especializado), no que concerne ao ajuste dos parâmetros dos controladores, foi comparado a outros dois algoritmos bastantes difundidos na literatura: Particle Swarm Optimization e o Algoritmo Genético com Elitismo. Os resultados demonstraram que o algoritmo Genético de Chu-Beasley Especializado foi mais eficiente que as demais técnicas apresentadas, obtendo soluções robustas quando variações de cargas foram consideradas, sendo, portanto, credenciado como ferramenta no estudo da análise d... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
5

Aplicação do algoritmo genético adaptativo com hipermutação no ajuste dos parâmetros dos controladores suplementares e dispositivo FACTS IPFC /

Cordero Bautista, Luis Gustavo January 2019 (has links)
Orientador: Percival Bueno de Araujo / Resumo: As perturbações ou variações de carga produzem oscilações eletromecânicas que devem ser amortecidas o mais rápido possível para garantir confiabilidade e estabilidade da rede. Neste trabalho apresenta-se uma análise do dispositivo FACTS Interline Power Flow Controller (IPFC) e o controlador Proporcional Integral (PI) no gerenciamento dos fluxos de potência e a influência dos Estabilizadores do Sistema de Potência (ESP) e do IPFC Power Oscillation Damping (POD) sobre a estabilidade do sistema elétrico de potência. Neste trabalho enfoca-se nos estudos de estabilidade a pequenas perturbações usando um Algoritmo Genético Adaptativo com Hiper-mutação (AGAH) para ajustar os parâmetros dos controladores suplementares de amortecimento, o Estabilizador de sistema de potência (ESPs) e o Power Oscillation Damping (POD) em forma coordenada. O AGAH tem como objetivo encontrar os parâmetros ótimos do controlador para melhorar o amortecimento fraco das oscilações de baixa frequência locais e inter-área. Neste trabalho representa-se o sistema de elétrico de potência com a inclusão do dispositivo Interline Power Flow Controller com o modelo de sensibilidade de corrente (MSC). Considera-se como sistema teste o sistema Simétrico de Duas Áreas e o sistema New England como o intuito de avaliar o algoritmo proposto. As simulações são feitas no ambiente do MatLab. Por fim, apresenta-se a comparação do algoritmo genético com o desempenho do algoritmo proposto. / Abstract: Small-magnitude disturbances happen to produce electro-mechanical oscillations which should be damped as quickly as possible to ensure reliability and stability of the network. This work presents an analysis of Interline Power Flow Controller (IPFC) FACTS device and PI controller to control and manage power flow and also how Power System Stabilizers and IPFC Power Oscillations Damping (POD) controller influence over an electric power system stability. This work focuses on small-signal stability studies using an Adaptive Genetic Algorithm with Hyper-mutation (AGAH) in order to tune controller parameters in a coordinated way ensuring proper damping. AGAH aims to find optimal controller parameters to enhance the poor damping of local and inter-area low frequency oscillations. This works represents the electric power system and Interline Power Flow Controller device by a current sensitivity model (CSM). This paper considers two areas 14 bus symmetrical power system and New England power system in order to assess proposed algorithm. Coding and Simulations take place in MatLab platform. AGAH and GA get compared by time convergence and performance. This paper shows AGAH is an interesting optimization technique which outweighs GA. / Mestre

Page generated in 0.1666 seconds