Spelling suggestions: "subject:"codificadores químicos"" "subject:"modificadores químicos""
1 |
Emprego de análise térmica na avaliação do comportamento térmico de níquel em presença de modificadores químicos /Sousa, Wellyngton Rosado de. January 2007 (has links)
Orientador: Clóvis Augusto Ribeiro / Banca: Marisa Veiga Capela / Banca: Eder Tadeu Gomes Cavalheiro / Resumo: O presente trabalho consiste na avaliação dos parâmetros cinéticos (E, A, f(a)) relativo à decomposição térmica do nitrato de níquel hexahidratado isolado e em presença de carbeto de tungstênio, de grafite, e de carbeto de tungstênio mais grafite, a partir da utilização de métodos não isotérmicos na avaliação de dados obtidos por análise termogravimétrica (TG). Identificação dos resíduos de decomposição térmica de nitrato de níquel e de suas misturas com ligantes orgânicos (ácido oxálico, ácido cítrico, ácido etileno diaminotetraacético (EDTA), ácido ascórbico e sacarose) em suporte de alumina e em presença de carbeto de tungstênio, de grafite, e de carbeto de tungstênio mais grafite, através de cálculos com dados e comportamento térmico obtidos das curvas TG sob atmosfera inerte e por análise de difração de raios - X (método do pó). Os resultados mostram que para a decomposição do nitrato de níquel puro e em presença de WC (carbeto de tungstênio), grafite, WC e grafite o modelo cinético que melhor se aplica em toda extensão é o modelo ESTÁK - BERGGREN ou autocalitico (SB), porém até aproximadamente 50% o processo pode ser governado por nucleação/crescimento, modelo Johnson - Mehl - Avrami - Erofeev - Kolgomorov (JMAEK). A presença de ligantes orgânicos influência de forma diferente na decomposição térmica no nitrato de níquel com formação de resíduos favorecendo ou não a formação de Ni0, NiO ou NiWO4; em complemento podem proteger ou favorecer a oxidação de WC por oxigênio residual. / Abstract: Not available. / Mestre
|
2 |
Emprego de análise térmica na avaliação do comportamento térmico de níquel em presença de modificadores químicosSousa, Wellyngton Rosado de [UNESP] 13 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:08Z (GMT). No. of bitstreams: 0
Previous issue date: 2007-07-13Bitstream added on 2014-06-13T19:17:24Z : No. of bitstreams: 1
sousa_wr_me_araiq.pdf: 1471121 bytes, checksum: 02a8f19f5f1305b98fe374ef6264bb94 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho consiste na avaliação dos parâmetros cinéticos (E, A, f(a)) relativo à decomposição térmica do nitrato de níquel hexahidratado isolado e em presença de carbeto de tungstênio, de grafite, e de carbeto de tungstênio mais grafite, a partir da utilização de métodos não isotérmicos na avaliação de dados obtidos por análise termogravimétrica (TG). Identificação dos resíduos de decomposição térmica de nitrato de níquel e de suas misturas com ligantes orgânicos (ácido oxálico, ácido cítrico, ácido etileno diaminotetraacético (EDTA), ácido ascórbico e sacarose) em suporte de alumina e em presença de carbeto de tungstênio, de grafite, e de carbeto de tungstênio mais grafite, através de cálculos com dados e comportamento térmico obtidos das curvas TG sob atmosfera inerte e por análise de difração de raios - X (método do pó). Os resultados mostram que para a decomposição do nitrato de níquel puro e em presença de WC (carbeto de tungstênio), grafite, WC e grafite o modelo cinético que melhor se aplica em toda extensão é o modelo ESTÁK - BERGGREN ou autocalitico (SB), porém até aproximadamente 50% o processo pode ser governado por nucleação/crescimento, modelo Johnson - Mehl - Avrami - Erofeev - Kolgomorov (JMAEK). A presença de ligantes orgânicos influência de forma diferente na decomposição térmica no nitrato de níquel com formação de resíduos favorecendo ou não a formação de Ni0, NiO ou NiWO4; em complemento podem proteger ou favorecer a oxidação de WC por oxigênio residual. / Not available.
|
3 |
Uso de modificadores permanentes em filamento de tungstênio para aprisionamento de hidretos de arsênio, selênio, antimônio e vapor de mercúrio e determinação por espectrometria de absorção atômica. / Use of permanent modifiers on tungsten coil for in situ trapping of hydrides of arsenic, selenium, antimony and mercury vapor and determination by atomic absorption.Souza, Samuel Simião de 08 December 2005 (has links)
Made available in DSpace on 2016-06-02T20:35:06Z (GMT). No. of bitstreams: 1
TeseSSS.pdf: 746207 bytes, checksum: 400bbde10cd3eda1342840875126ef5b (MD5)
Previous issue date: 2005-12-08 / Universidade Federal de Minas Gerais / In this work, a systematic evaluation of permanent chemical
modifiers on tungsten coil atomizer for in situ trapping of selenium hydride (H2Se), arsine (AsH3), stibine (SbH3) and mercury vapor was done. The trapping occurred on tungsten coil surface coated with rhodium, iridium or ruthenium. A continuous flow system for generating the volatile species was coupled to the atomizer by a capillary quartz tube (50 mm long and 2.0 mm inner diameter) positioned at 0.5 mm from the modified tungsten surface. In this thesis, a new device for automatic in situ trapping of hydrides in tungsten coil was developed. This device is controlled by a program
written in Visual Basic that is also used for management of the continuous flow system for hydride generation. This coupling can be easily implemented in any spectrometer simplifying the in situ trapping of hydrides in this electrothermal atomizer. The same system was used for the determination of Se and As in water and biological materials, and for investigating the possibilities for the determination of
Sb and Hg. The coating with Rh showed higher efficiency to trap the species than Ir and Ru, resulting in better sensitivities. Using tungsten coil coated with 200 µg Rh
pre-heated at 400 °C, sample flowing at 3.0 mL min-1 and trapping time of 30 s, enrichment factors of approximately 150 times for As and Se were obtained with limits of detection of 35 ng L-1 Se and 110 ng L-1 As. With Ir and Ru the enrichment factors for As and Se were 100 and 115 times, respectively. Using the proposed system it was also possible the speciation of inorganic arsenic in water samples. The
evaluation of trapping efficiency on tungsten coil was made by conventional atomic absorption measurements and with the aid of radiotracers. The results obtained in the two modes of evaluation showed conflicting values, indicating a possible
difference between the atomization mechanism of analytes when injected in the atomizer as liquid solution and when trapped as hydride on the tungsten coil surface with a permanent chemical modifier. The results obtained with radiotracers showed 69 ± 2% trapping efficiency of H2Se on tungsten coated with Rh. The trapping efficiencies with Ir and Ru were approximately 55%. For SbH3 the trapping efficiency
was 82 ± 1% on tungsten coil coated with Rh. The behavior of generation and collection of SbH3 on tungsten coil still needs better evaluation due to the problems of reproducibility influenced by possible losses during hydride transport. Trapping of mercury vapor on tungsten coil coated with Rh showed a pronounced saturation of the tungsten surface resulting in limited linearity of calibration curve and comparatively poor repeatability ( RSD > 9%). / No presente trabalho, realizou-se um estudo sistemático do uso de modificadores químicos permanentes sobre atomizador de filamento de tungstênio para o aprisionamento de hidreto de selênio (H2Se), arsina (AsH3), estibina (SbH3) e vapor elementar de mercúrio. O aprisionamento deu-se sobre o filamento de tungstênio revestido com ródio ou irídio ou rutênio. Um sistema de fluxo contínuo para geração das espécies voláteis foi acoplado ao atomizador por um tubo capilar de quartzo (50 mm de comprimento e 2,0 mm de diâmetro interno) conectado por tubos de PTFE e posicionado a 0,5 mm da superfície modificada do filamento. Nesta tese também foi desenvolvido um dispositivo automático para coletar diretamente sobre o filamento de tungstênio os hidretos formados. Esse dispositivo é controlado por um programa escrito em Visual Basic que também é utilizado no gerenciamento do sistema de fluxo contínuo para geração de hidretos. Esse dispositivo pode ser utilizado em qualquer equipamento, simplificando-se a implantação do método de geração de hidretos com aprisionamento no próprio atomizador. O mesmo sistema foi utilizado para determinar Se e As em diferentes matrizes. Condições para determinação de Sb e Hg foram estudadas. O revestimento constituído por Rh mostrou-se mais eficaz na retenção das espécies estudadas resultando em melhores sensibilidades. Utilizandose filamento de tungstênio revestido com 200 µg Rh pré-aquecido a 400°C, amostra fluindo a 3,0 mL min-1 e tempo de coleta de 30 s, obtiveram-se fatores de enriquecimento de aproximadamente 150 vezes para As e Se com limites de detecção de 35 ng L-1 Se e 110 ng L-1 As. Os fatores de enriquecimento com Ir e Ru
como modificadores permanentes para Se e As, foram de aproximadamente 100 e 115 vezes, respectivamente. Utilizando-se o sistema proposto foi possível fazer a especiação de arsênio inorgânico em águas. A avaliação das eficiências de retenção das espécies sobre filamento de tungstênio foi feita por medidas de absorção atômica e com radioisótopos. O resultados obtidos nos dois modos de avaliação mostraram valores discordantes, indicando possíveis diferenças nos mecanismos de atomização dos analitos quando injetados em solução aquosa e quando retidos na superfície modificada do filamento na forma de hidretos. Os estudos com radioisótopos mostraram que as eficiências de retenção do H2Se sobre filamento revestido foram de 69 ± 2% com Rh, 54 ± 3% com Ir e 55 ± 3% com Ru. Para SbH3 a eficiência foi de 82 ± 1% utilizando-se Rh como modificador permanente. O comportamento da geração e retenção de bismutina sobre o filamento foi bastante crítico, e estudos complementares são recomendados para uma melhor avaliação
devido aos problemas de reprodutibilidade causados por possíveis perdas durante o transporte. A retenção de vapor de mercúrio sobre filamento revestido com Rh foi marcada por fácil saturação da superfície do filamento, resultando numa estreita faixa linear da curva analítica de calibração e por problemas de repetibilidade do sinal.
|
Page generated in 0.0697 seconds