• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Fator de Correção de Dose Individual Em Grupos Ocupacionais Obtido Por Monitoração Individual Externa Em Serviço de Medicina Nuclear

SILVA NETO, José Almeida da 11 September 2012 (has links)
Submitted by Eduarda Figueiredo (eduarda.ffigueiredo@ufpe.br) on 2015-03-04T18:08:30Z No. of bitstreams: 2 DISSERTAÇÃO - JOSE ALMEIDA DA SILVA NETO.pdf: 1960336 bytes, checksum: da6ce93440f3f182289989e6e6fbdcd0 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-04T18:08:30Z (GMT). No. of bitstreams: 2 DISSERTAÇÃO - JOSE ALMEIDA DA SILVA NETO.pdf: 1960336 bytes, checksum: da6ce93440f3f182289989e6e6fbdcd0 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012-09-11 / CAPES / A Comissão Internacional de Proteção Radiológica recomenda a dose efetiva como relacionamento do risco de exposição humana aos limites de doses de corpo inteiro, sendo uma medida de proteção para o público e indivíduos ocupacionalmente expostos (IOE). Na rotina dos IOE onde há proximidade às fontes radioativas faz-se uso de avental de chumbo, ao qual gera heterogeneidade de exposição. Sabe-se que o uso de um único dosímetro estima a dose efetiva equivocadamente. No Brasil, a dose efetiva é estimada por uso do dosímetro na região do tórax, sobre o avental, aplicando o fator de correção de 1/10, voltado apenas para área de radiodiagnósticos. Portanto, objetivou-se o fator de correção por monitoração individual externa da rotina dos IOE no Serviço de Medicina Nuclear-Hospital das Clínicas/UFPE. O método teve como base mensurar doses sob e sobre o avental, em etapas de monitorações de rotina dos IOE periodicamente, e exposições experimentais aos radionuclídeos 99mTc e 131I. Após cada mês, nas monitorações de rotina, obteve-se a leitura dos dosímetros e fator de correção calculado na razão dose sob o avental/dose sobre o avental. Obtiveram-se na rotina os fatores de médias 0,88±0,13 (99mTc) e 0,98±0,08 (131I) (Ambos: 0,91±0,12). Experimentalmente as médias foram de 0,81 (99mTc) e 0,99 (131I). Dessa forma, sugere-se o fator 0,91±0,12, porém, se fazem necessárias análises mais abrangentes em procedimentos com outros radionuclídeos e em rotinas adicionais de exposição aos IOE, pois, o fator de correção demonstrou-se variável aos radionuclídeos.
2

Desenvolvimento do dosímetro termoluminescente de CaSO4:Ce, Eu para a monitoração individual e a dosimetria clínica de fótons e elétrons / Development of CaSO4:Ce,Eu thermoluminescent dosimeters for individual monitoring for external exposures and clinical dosimetry

Maíra Goes Nunes 17 December 2012 (has links)
Detectores de sulfato de cálcio ativado com cério IV e európio III utilizando o politetrafluoretileno (PTFE, Teflon®) free-flow como aglutinante (CaSO4:Ce,Eu + Teflon®) foram produzidos pelo método da estampagem, desenvolvido em colaboração com a empresa Tecnoflon, a partir de cristais crescidos de acordo com uma nova variação da rota da evaporação lenta, também apresentada nesse trabalho, com as concentrações de 0,16 mol% de Eu3+ e de 0,15 mol% de Ce4+ na solução ácida precursora. O modelo de dosímetro pessoal desenvolvido consiste em cinco detectores aderidos a um cartão de 30 x 48 mm de cloreto de polivinila (PVC) 95% opaco à luz na faixa do espectro eletromagnético que vai do infravermelho ao ultravioleta, idêntico aos cartões de identificação utilizados no IPEN, por uma tira de 10 x 35 mm de filme adesivo do mesmo material e foi submetido aos testes de aceitação descritos no regulamento técnico IRD-RT Nº 002.01/95, Desempenho de Sistemas de Monitoração Individual Critérios e Condições, sendo aprovado em todos os testes. Para a dosimetria clínica, os próprios detectores foram considerados dosímetros termoluminescentes e submetidos aos testes de aceitação descritos no código de práticas da Agência Internacional de Energia Atômica Technical Report Series Nº 398, Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water, [TRS-398, IAEA, 2000] adotado como protocolo de dosimetria pela maioria dos hospitais, sendo igualmente aprovados nesses testes. Os dosímetros desenvolvidos podem ser utilizados para a monitoração individual externa e para dosimetria clínica, apresentando a diferenciação do tipo e da energia da radiação com que foram irradiados e a redução de custos como as principais vantagens em relação aos dosímetros termoluminescentes atualmente utilizados nessas aplicações. / Calcium sulphate activated with cerium IV and europium III using the free-flow polytetrafluoroethylene (PTFE, Teflon®) as bonder were produced by the stamping method, developed by the collaboration of Tecnoflon industries, from crystals growth according to a new variation of the slow evaporation method, also described in this study, with Eu3+ and Ce4+ concentrations of respectively 0.15 mol% and 0.16 mol% in the precursory acid solution. The developed personal dosimeter consist of five detectors adhered to a 30 x 48 mm polyvinyl chloride (PVC) card 95% mat to light in the infrared to ultraviolet wavelengths, identical to the access cards used by IPEN staff, by a 10 x 35 mm adhesive strip of the same material and it passed the acceptance tests required by Brazilian national regulatory committee for appliance in individual monitoring of external exposure services. The own detector is considered a dosimeter as far as clinical dosimetry is concerned and it passed the acceptance tests suggested by the International Atomic Energy Agency in the Technical Report Series Nº 398, Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water, [TRS-398, IAEA, 2000] adopted as the dosimetry protocol by most hospitals. Hence, the developed dosimeters can be applied in the individual monitoring for external exposure and in the clinical dosimetry, having the radiation type and energy differentiation and the cost reduction as the key advantages over the currently used thermoluminescent dosimeters in such applications.
3

Desenvolvimento do dosímetro termoluminescente de CaSO4:Ce, Eu para a monitoração individual e a dosimetria clínica de fótons e elétrons / Development of CaSO4:Ce,Eu thermoluminescent dosimeters for individual monitoring for external exposures and clinical dosimetry

Nunes, Maíra Goes 17 December 2012 (has links)
Detectores de sulfato de cálcio ativado com cério IV e európio III utilizando o politetrafluoretileno (PTFE, Teflon®) free-flow como aglutinante (CaSO4:Ce,Eu + Teflon®) foram produzidos pelo método da estampagem, desenvolvido em colaboração com a empresa Tecnoflon, a partir de cristais crescidos de acordo com uma nova variação da rota da evaporação lenta, também apresentada nesse trabalho, com as concentrações de 0,16 mol% de Eu3+ e de 0,15 mol% de Ce4+ na solução ácida precursora. O modelo de dosímetro pessoal desenvolvido consiste em cinco detectores aderidos a um cartão de 30 x 48 mm de cloreto de polivinila (PVC) 95% opaco à luz na faixa do espectro eletromagnético que vai do infravermelho ao ultravioleta, idêntico aos cartões de identificação utilizados no IPEN, por uma tira de 10 x 35 mm de filme adesivo do mesmo material e foi submetido aos testes de aceitação descritos no regulamento técnico IRD-RT Nº 002.01/95, Desempenho de Sistemas de Monitoração Individual Critérios e Condições, sendo aprovado em todos os testes. Para a dosimetria clínica, os próprios detectores foram considerados dosímetros termoluminescentes e submetidos aos testes de aceitação descritos no código de práticas da Agência Internacional de Energia Atômica Technical Report Series Nº 398, Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water, [TRS-398, IAEA, 2000] adotado como protocolo de dosimetria pela maioria dos hospitais, sendo igualmente aprovados nesses testes. Os dosímetros desenvolvidos podem ser utilizados para a monitoração individual externa e para dosimetria clínica, apresentando a diferenciação do tipo e da energia da radiação com que foram irradiados e a redução de custos como as principais vantagens em relação aos dosímetros termoluminescentes atualmente utilizados nessas aplicações. / Calcium sulphate activated with cerium IV and europium III using the free-flow polytetrafluoroethylene (PTFE, Teflon®) as bonder were produced by the stamping method, developed by the collaboration of Tecnoflon industries, from crystals growth according to a new variation of the slow evaporation method, also described in this study, with Eu3+ and Ce4+ concentrations of respectively 0.15 mol% and 0.16 mol% in the precursory acid solution. The developed personal dosimeter consist of five detectors adhered to a 30 x 48 mm polyvinyl chloride (PVC) card 95% mat to light in the infrared to ultraviolet wavelengths, identical to the access cards used by IPEN staff, by a 10 x 35 mm adhesive strip of the same material and it passed the acceptance tests required by Brazilian national regulatory committee for appliance in individual monitoring of external exposure services. The own detector is considered a dosimeter as far as clinical dosimetry is concerned and it passed the acceptance tests suggested by the International Atomic Energy Agency in the Technical Report Series Nº 398, Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water, [TRS-398, IAEA, 2000] adopted as the dosimetry protocol by most hospitals. Hence, the developed dosimeters can be applied in the individual monitoring for external exposure and in the clinical dosimetry, having the radiation type and energy differentiation and the cost reduction as the key advantages over the currently used thermoluminescent dosimeters in such applications.

Page generated in 0.0747 seconds