• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 2
  • 1
  • Tagged with
  • 12
  • 12
  • 9
  • 7
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo laboratorial dos danos causados pelo broqueamento e retificação em corpos-de-prova testemunhos

Lerissa Hydaradaya Moura Santos de Farias, Hannah January 2006 (has links)
Made available in DSpace on 2014-06-12T17:39:56Z (GMT). No. of bitstreams: 2 arquivo6156_1.pdf: 2781091 bytes, checksum: b63f1b31346dece241dd73b026baad61 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2006 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / É comum na prática da engenharia a utilização de corpos-de-prova testemunhos para avaliação da resistência à compressão do concreto; isso ocorre em edificações antigas quando não se têm dados a respeito do concreto por ocasião da restauração das estruturas ou em estruturas novas quando há dúvidas em relação à qualidade do concreto executado. Diversos são os fatores que interferem na determinação do valor da resistência do concreto quando utilizamos testemunhos, por exemplo: nível de resistência do concreto, diâmetro e altura do testemunho, a relação entre diâmetro/altura, umidade do corpo-de-prova, idade, posição do corpo-de-prova extraído da estrutura, efeito causado pela extratora, etc. Diversas normas de projetos citam a influência do efeito do broqueamento, mas não apresentam coeficientes de correção, exceto a do ACI 214.4R-03. Neste trabalho são descritos e analisados os resultados experimentais de corpos-de-prova extraídos com objetivo de identificar o efeito do broqueamento e da retificação levando-se em consideração a posição da concretagem com relação à extração e a relação altura diâmetro. Foram confeccionados 180 blocos de tamanho 30x30cm dos quais foram extraídos 180 corpos-de-prova testemunhos de uma única resistência (fcm=29MPa) produzidos em um caminhão betoneira. Os testemunhos e os corpos-de-prova de referência foram submetidos as mesmas condições de umidade. A relação altura/diâmetro dos corpos-de-prova testemunhos foi variável. Foram extraídos testemunhos com relações h/d iguais a 1,0, 1,5 e 2,0. Foram moldados 57 corpos-de-prova de tamanho 150x300 e 60 de tamanho 100x200 que foram os corpos-de-prova para comparação. Os testemunhos foram extraídos com a idade de 180 dias. Os resultados dos ensaios foram tratados estatisticamente e garantem sua confiabilidade. Para os testemunhos de relação altura/diâmetro igual a dois o coeficiente de 1,06, como fator de correção devido aos danos causados pela extratora, preconizado pela norma ACI 214.4R-03 foi observado neste trabalho
2

Estudo laboratorial dos danos causados pelo broqueamento e retificação em corpos-de-prova testemunhos

Leressa Hydaradaya Moura Santos de Farias, Hannah January 2006 (has links)
Made available in DSpace on 2014-06-12T17:41:44Z (GMT). No. of bitstreams: 2 arquivo6520_1.pdf: 2781091 bytes, checksum: b63f1b31346dece241dd73b026baad61 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2006 / É comum na prática da engenharia a utilização de corpos-de-prova testemunhos para avaliação da resistência à compressão do concreto; isso ocorre em edificações antigas quando não se têm dados a respeito do concreto por ocasião da restauração das estruturas ou em estruturas novas quando há dúvidas em relação à qualidade do concreto executado. Diversos são os fatores que interferem na determinação do valor da resistência do concreto quando utilizamos testemunhos, por exemplo: nível de resistência do concreto, diâmetro e altura do testemunho, a relação entre diâmetro/altura, umidade do corpo-de-prova, idade, posição do corpo-de-prova extraído da estrutura, efeito causado pela extratora, etc. Diversas normas de projetos citam a influência do efeito do broqueamento, mas não apresentam coeficientes de correção, exceto a do ACI 214.4R-03. Neste trabalho são descritos e analisados os resultados experimentais de corpos-de-prova extraídos com objetivo de identificar o efeito do broqueamento e da retificação levando-se em consideração a posição da concretagem com relação à extração e a relação altura diâmetro. Foram confeccionados 180 blocos de tamanho 30x30cm dos quais foram extraídos 180 corpos-de-prova testemunhos de uma única resistência (fcm=29MPa) produzidos em um caminhão betoneira. Os testemunhos e os corpos-de-prova de referência foram submetidos as mesmas condições de umidade. A relação altura/diâmetro dos corpos-de-prova testemunhos foi variável. Foram extraídos testemunhos com relações h/d iguais a 1,0, 1,5 e 2,0. Foram moldados 57 corpos-de-prova de tamanho 150x300 e 60 de tamanho 100x200 que foram os corpos-de-prova para comparação. Os testemunhos foram extraídos com a idade de 180 dias. Os resultados dos ensaios foram tratados estatisticamente e garantem sua confiabilidade. Para os testemunhos de relação altura/diâmetro igual a dois o coeficiente de 1,06, como fator de correção devido aos danos causados pela extratora, preconizado pela norma ACI 214.4R-03 foi observado neste trabalho
3

Fator de Correção de Dose Individual Em Grupos Ocupacionais Obtido Por Monitoração Individual Externa Em Serviço de Medicina Nuclear

SILVA NETO, José Almeida da 11 September 2012 (has links)
Submitted by Eduarda Figueiredo (eduarda.ffigueiredo@ufpe.br) on 2015-03-04T18:08:30Z No. of bitstreams: 2 DISSERTAÇÃO - JOSE ALMEIDA DA SILVA NETO.pdf: 1960336 bytes, checksum: da6ce93440f3f182289989e6e6fbdcd0 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-04T18:08:30Z (GMT). No. of bitstreams: 2 DISSERTAÇÃO - JOSE ALMEIDA DA SILVA NETO.pdf: 1960336 bytes, checksum: da6ce93440f3f182289989e6e6fbdcd0 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012-09-11 / CAPES / A Comissão Internacional de Proteção Radiológica recomenda a dose efetiva como relacionamento do risco de exposição humana aos limites de doses de corpo inteiro, sendo uma medida de proteção para o público e indivíduos ocupacionalmente expostos (IOE). Na rotina dos IOE onde há proximidade às fontes radioativas faz-se uso de avental de chumbo, ao qual gera heterogeneidade de exposição. Sabe-se que o uso de um único dosímetro estima a dose efetiva equivocadamente. No Brasil, a dose efetiva é estimada por uso do dosímetro na região do tórax, sobre o avental, aplicando o fator de correção de 1/10, voltado apenas para área de radiodiagnósticos. Portanto, objetivou-se o fator de correção por monitoração individual externa da rotina dos IOE no Serviço de Medicina Nuclear-Hospital das Clínicas/UFPE. O método teve como base mensurar doses sob e sobre o avental, em etapas de monitorações de rotina dos IOE periodicamente, e exposições experimentais aos radionuclídeos 99mTc e 131I. Após cada mês, nas monitorações de rotina, obteve-se a leitura dos dosímetros e fator de correção calculado na razão dose sob o avental/dose sobre o avental. Obtiveram-se na rotina os fatores de médias 0,88±0,13 (99mTc) e 0,98±0,08 (131I) (Ambos: 0,91±0,12). Experimentalmente as médias foram de 0,81 (99mTc) e 0,99 (131I). Dessa forma, sugere-se o fator 0,91±0,12, porém, se fazem necessárias análises mais abrangentes em procedimentos com outros radionuclídeos e em rotinas adicionais de exposição aos IOE, pois, o fator de correção demonstrou-se variável aos radionuclídeos.
4

Modelagem computacional do desempenho térmico de trocadores de calor de fluxo cruzado e casco e tubos / Numerical methodologies for thermal performance of crossflow and shell-and-tube heat exchangers

Magazoni, Felipe Costa 18 November 2016 (has links)
O presente trabalho descreve e introduz uma metodologia numérica de simulação térmica de trocadores de calor de fluxo cruzado e de casco e tubo. A metodologia computacional é utilizada para simular doze configurações de arranjos de escoamento de trocadores de calor de fluxo cruzado com número de passes e tubos por passe arbitrários, assim como diversas condições de mistura de ambos os fluidos. O procedimento computacional é desenvolvido, baseado em diversos trabalhos da literatura, para calcular a efetividade de temperatura e o fator de correção da diferença média logarítmica de temperatura para trocadores de calor de fluxo cruzado em escoamentos contracorrente e paralelo. Novos dados da efetividade de temperatura e do fator de correção para configurações complexas de trocadores de calor são apresentados em diversas tabelas e figuras. As condições de mistura do fluido interno depois de cada passe são analisadas e caracterizadas por três configurações: misturado, não misturado com uma ordem idêntica das fileiras e não misturado com uma ordem inversa das fileiras. A influência da mistura do fluido externo entre os tubos do trocador de calor também é analisada. A metodologia computacional também é utilizada para trocadores de calor de casco e tubo tipo TEMA E com um passe de ambos os fluidos (fluidos do casco e dos tubos) em escoamentos contracorrente e paralelo de acordo com as entradas do trocador de calor. O algoritmo é baseado em diversas hipóteses e considerações de modelagem adotadas em diversos trabalhos de trocadores de calor de fluxo cruzado e de casco e tubo. Cada seção entre as chicanas é idealizada como um trocador de calor não misturado - não misturado. Além disso, este estudo fornece um sumário de correlações matemáticas exatas e aproximadas para algumas configurações de trocadores de calor de fluxo cruzado e de casco e tubo, que são muito apropriadas para análises computacionais e que facilitam o cálculo de efetividade de temperatura e do fator de correção. Os resultados encontrados são comparados com o algoritmo HETE e com soluções e relações matemáticas disponíveis em outras literaturas e mostram a capacidade dos algoritmos desenvolvidos. / The present thesis describes and introduces the numerical simulation methodologies for thermal modeling of crossflow and shell-and-tube heat exchangers. The computational methodology is used for simulating twelve general flow arrangement configurations of crossflow heat exchangers with arbitrary number of passes and tubes per pass, as well as, several mixture conditions of both fluids. The computational procedures are developed, based on some works from literature, to calculate the temperature effectiveness and the mean logarithm temperature difference (MLTD) correction factor for crossflow and parallel and counter-crossflow heat exchangers. New temperature effectiveness and correction factor data for the treated complex flow arrangements configurations are provided and showed in various tables and plots. Tube fluid mixing conditions after each pass, characterized by three types of configuration: tube fluid mixed; tube fluid unmixed keeping identical order of the rows; and tube fluid unmixed with inverted order of the rows, are analyzed. The influence of external fluid mixing between tube rows along the heat exchanger configurations is also addressed. The computational methodology is also addressed to TEMA E shell-and-tube heat exchangers type with one-pass of both fluids (in-tube and shell side) flowing in counterflow and parallel regarding the heat exchangers inlets. The algorithm is based on various assumptions and modelling considerations adopted in several works of crossflow and shell-and-tube heat exchangers. Each section between two baffles is idealized as an unmixed-unmixed crossflow heat exchanger. In addition, this study provides a summary of exact and approximate correlations for some configurations of crossflow and shell-and-tube heat exchangers, that are very appropriate for computerized analysis and that facilitate the computation of both parameters, the temperature effectiveness and the mean logarithmic temperature difference correction factor. The results found are compared to algorithm HETE and with available relations and solutions of other works and show the capability of the developed algorithm.
5

Desenvolvimento de uma metodologia de calibração de monitores de contaminação de superfície considerando o mapeamento da uniformidade das fontes extensas de referência / Development of a calibration methodology of surface contamination monitors considering the uniformity mapping of the large area reference sources

Silva Junior, Iremar Alves da 06 December 2017 (has links)
Uma das exigências na calibração de monitores de radiação de contaminação de superfície consiste no uso de fontes extensas de referência com um valor de uniformidade superior a 90%. Entretanto, foi verificado em alguns laboratórios de calibração que suas fontes não atendiam essa exigência, o que obrigaria esses laboratórios a não utilizarem tais fontes em suas calibrações. Foi neste contexto que foi desenvolvido um estudo para propor o uso dessas fontes, desde que sejam utilizados fatores de correção, que são propostos neste trabalho, que foram avaliados e desenvolvidos usando o código de transporte MCNP como ferramenta de análise e avaliação, a partir dos dados de mapeamento da uniformidade. Também foi desenvolvido um software para calcular esses fatores de correção, utilizando o mapeamento da uniformidade das fontes como dados de entrada e um sistema automatizado para calibração de monitores de radiação de contaminação de superfície. O grande ganho com esse trabalho foi poder utilizar fontes extensas de referência, mesmo quando essas estão em desacordo com as exigências de uniformidade da norma ABNT ISO 8769:2016. / One of the requirements in the calibration of surface contamination radiation monitors is the use of wide area reference sources with a uniformity value greater than 90%. However, it has been found, in some calibration laboratories, that their sources were not meeting this requirement, which would not allow these laboratories to use such sources in their calibration procedures. It was in this context that a study was developed to propose the use of these sources, provided that correction factors are used, which are proposed in this work, which were evaluated and developed using the MCNP radiation transport code as an evaluation tool, from the uniformity mapping data. A software was also developed to calculate these correction factors using the source uniformity mapping as an input data along with an automated system for calibration of surface contamination radiation monitors. The great gain in this work was to be able to use wide area reference sources, even when they are in disagreement with the uniformity requirements of ISO 8769:2016.
6

Study and evaluation of correction factors applied to ionization chambers in radiotherapy photon beams / Estudo e avaliação de fatores de correção aplicados a câmaras de ionização em feixes de fótons radioterápicos.

Reis, Cristiano Queiroz Melo dos 30 July 2015 (has links)
The use of a beam quality correction factor,kQ, is needed in dosimetry of radiotherapy beams for correcting differences between chamber responses at the calibration beam quality, Q0 and at the quality beam of the user, Q. The purpose of this study is to determine the beam quality correction factor for the NE2571 ionization chamber widely used in radiotherapy and its dependence with the stopping-power and the chamber perturbation factors. In addition, an investigation of the use of parallel plate chambers for determining surface doses in photon beams is also performed using the EGSrnc Monte Carlo code system. Results obtained with PENELOPE show that simulations with phase-space files appropriately scored can be up to ten times shorter than using a full spectrum in the input-file. Values of kQ, and its components show good agreement with published values in the literature and are provided with typical statistical uncertainties of 0.2%. Values of kQ and absorbed dose to water conversion factors obtained with egs_chamber user code for parallel plate chambers are also provided with maximum statistical uncertainty of 0.7%. Therefore, the results obtained are expected to contribute with improving dosimetry protocols and the quality of life of radiotherapy patients. / O uso de uma fator de correção para a qualidade do feixe, kQ, é necessário em dosimetria de feixes radioterápicos para a correçãoo das diferenças entre a resposta de câmaras de ionização nas qualidades do feixe de calibração, Q0 e do usuário Q. O propósito deste trabalho consiste em determinar o fator de correção da qualidade de feixe para a câmara de ionização NE2571 amplamente utilizada em radioterapia e sua dependência com o stopping-power e os fatores de perturbação da câmara. Além disso, uma investigação do uso de câmaras de placas paralelas para determinar doses na superfície em feixes de fótons é também realizada usando o sistem de códigos em Monte Carlo EGSnrc. Resultados obtidos com o PENELOPE mostram que simulações usando phase-space, podem ser cerca de dez vezes menos longa do que simula ções usando um espectro completo no arquivo de entrada. Valores de kQ e suas componentes mostraram boa concordncia com dados publicados na literatura e são fornecidos com incertezas estatísticas típicas de 0.2%. Valores de kQ e fatores de conversão pra dose absorvida na água obtidos para as câmaras de placas paralelas com o código de usuário egs_chamber são também fornecidos com incerteza estatística máxima de 0.7%. Deste modo, espera-se que os resultados obtidos possam contribuir com o aperfeiçoamento de protocolos de dosimetria e com a qualidade de vida de pacientes radioterpicos.
7

Simulaçõeses numéricas de efeitos de acidentes de linha causados por curvas à montante de medidores de vazão por ultrassom de um canal por tempo de trânsito para gás de flare / Numerical simulations of installation effects caused by upstream elbows on single-path transit-time ultrasonic flare flow meters

Martins, Ramon Silva 23 May 2012 (has links)
Made available in DSpace on 2016-12-23T14:08:08Z (GMT). No. of bitstreams: 1 Martins RS Part 1.pdf: 212782 bytes, checksum: 40ca14a4b97179f5b3af71f964306b97 (MD5) Previous issue date: 2012-05-23 / Oil and gas industry requires accurate flow measurements since they are stated by law. Nevertheless, curves and other obstacles are commonly found in such industry field, which may affect the quality of flow measurement due to flow disturbances, such as swirl and velocity profile asymmetries. Single-path ultrasonic flow meters are often used in flare gas installations, despite being sensitive to such disturbances. The present work use commercial CFD codes to obtain disturbed flow fields downstream from single and double elbow pipe installations, aiming to investigate both magnitude and behaviour of such effects on ultrasonic flow measurement. Numerical integration is applied for several acoustic path arrangements, simulating single-path ultrasonic flow meters in different situations in order to evaluate its correction factor deviation under disturbed conditions. Reynolds numbers from 1X10 4 to 2 X10 6 are considered. Transducers mounting angles from 0° to 180° are tested and axial positions up to 80D downstream from the curve are evaluated. Results indicate that single-path ultrasonic flow meters are sensitive to installation effects. Correction factor deviations usually showed to be significantly higher than 2% for axial positions shorter than 20D, as recommended by several manufacturers or regulations. Nevertheless, deviations may reach 0.01% in some specific configurations, which suggests that ultrasonic flow measurement might be improved by rearranging flow meter device in favourable angular position and mainly by implementation of specific functions for correction factors under disturbed conditions / A indústria de petróleo e gás requer medições de vazão de baixa incerteza, uma vez que são estabelecidas por lei. Contudo, curvas e outros obstáculos são comumente encontrados nesse cenário e podem afetar a qualidade da medição de vazão em função de perturbações no escoamento, tais como swirl e assimetrias no perfil de velocidades. Medidores de vazão por ultrassom de um canal são frequentemente utilizados em instalações de gás de queimadores, apesar de serem sensíveis a tais perturbações. O presente trabalho usa códigos comerciais de CFD para obter o escoamento à jusante de instalações com uma curva e duas curvas, visando a investigar a magnitude e o comportamento de tais efeitos na medição de vazão. Integração numérica é utilizada para diversos arranjos de caminho acústico, simulando medidores de vazão por ultrassom de um canal em várias condições para avaliar o desvio do fator de correção em escoamentos perturbados. Números de Reynolds de 1×10 4 a 2×10 6 são considerados. Ângulos de montagem dos transdutores de 0° a 180° são testados e posições axiais até 80D à jusante do obstáculo são avaliadas. Os resultados indicam que medidores de vazão por ultrassom são sensíveis aos efeitos de acidente de linha. O desvio do fator de correção mostra-se, em geral, consideravelmente maior que 2% em distâncias menores que 20D, conforme recomendado por alguns fabricantes e por leis. Não obstante, tais desvios podem atingir 0,01% em algumas configurações específicas, o que sugere que a medição de vazão por ultrassom pode ser melhorada pelo rearranjo do aparato em posição angular favorável e, principalmente, pela implementação de funções específicas para fatores de correção em condições perturbadas
8

Desenvolvimento de uma metodologia de calibração de monitores de contaminação de superfície considerando o mapeamento da uniformidade das fontes extensas de referência / Development of a calibration methodology of surface contamination monitors considering the uniformity mapping of the large area reference sources

Iremar Alves da Silva Junior 06 December 2017 (has links)
Uma das exigências na calibração de monitores de radiação de contaminação de superfície consiste no uso de fontes extensas de referência com um valor de uniformidade superior a 90%. Entretanto, foi verificado em alguns laboratórios de calibração que suas fontes não atendiam essa exigência, o que obrigaria esses laboratórios a não utilizarem tais fontes em suas calibrações. Foi neste contexto que foi desenvolvido um estudo para propor o uso dessas fontes, desde que sejam utilizados fatores de correção, que são propostos neste trabalho, que foram avaliados e desenvolvidos usando o código de transporte MCNP como ferramenta de análise e avaliação, a partir dos dados de mapeamento da uniformidade. Também foi desenvolvido um software para calcular esses fatores de correção, utilizando o mapeamento da uniformidade das fontes como dados de entrada e um sistema automatizado para calibração de monitores de radiação de contaminação de superfície. O grande ganho com esse trabalho foi poder utilizar fontes extensas de referência, mesmo quando essas estão em desacordo com as exigências de uniformidade da norma ABNT ISO 8769:2016. / One of the requirements in the calibration of surface contamination radiation monitors is the use of wide area reference sources with a uniformity value greater than 90%. However, it has been found, in some calibration laboratories, that their sources were not meeting this requirement, which would not allow these laboratories to use such sources in their calibration procedures. It was in this context that a study was developed to propose the use of these sources, provided that correction factors are used, which are proposed in this work, which were evaluated and developed using the MCNP radiation transport code as an evaluation tool, from the uniformity mapping data. A software was also developed to calculate these correction factors using the source uniformity mapping as an input data along with an automated system for calibration of surface contamination radiation monitors. The great gain in this work was to be able to use wide area reference sources, even when they are in disagreement with the uniformity requirements of ISO 8769:2016.
9

Comportamento e correção da radiação solar difusa obtida com o anel de sombreamento

Drechmer, Patricia Aparecida de Oliveira 01 August 2005 (has links)
Made available in DSpace on 2017-07-10T19:25:06Z (GMT). No. of bitstreams: 1 Patricia de Oliveira Drechmer.pdf: 703873 bytes, checksum: c5f64d1a8f42cf596ce9e2edd113b6b8 (MD5) Previous issue date: 2005-08-01 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This paper shows the comportment of solar radiation global, direct and diffuse radiation at Cascavel, classifies the sky s cover in function of the cloudiness index and studies the applicability of the numeric correction of RICIERI (1998) on diffuse radiation measured with a shadow ring. The research was done at meteorological experimental station of UNIOESTE, Cascavel. The solar radiation components were monitored from January 03, 2001 to February 14, 2003. The global radiation was monitored by a pyranometer KIPP & ZONEN-CM3 and the direct radiation were monitored by a pyrheliometer EPPLEY-NIP coupled to a solar tracer. The diffuse radiation was monitored by the difference between global radiation and direct radiation projected over the horizontal surface and by a pyranometer covered by a shadow ring. The monthly average levels of the global, direct and diffuse irradiations were 51,8%, 31,7% and 20,17% of the irradiation over the atmosphere s top. The diffuse irradiation measured by the difference method and by the shadow ring method corrected by DRUMMOND s factor and compared through the relative daily deviation. It was observed that, in 94% of the days, the diffuse radiation by DRUMMOND s factor was lower than the difference method. The deviations were higher for cloudless days (19,82%), than for partially cloudy days (9,55%) and cloudy days (2,68%). The RICIERI s correction (1998), that proposes the correlation of diffuse irradiation without correction with the diffuse irradiation by the difference method, was used and the linear function Rd=0,16545+1,21715R d was found to correct the diffuse by the shadow ring method. This correction increases the precision of the diffuse fraction obtained by shadow ring, decreasing the average relative deviation from 11,79%, when the DRUMMOND s correlation was applied, to 7,37%. In order to increase the model s precision, it was proposed the partial numeric equation fitted in function of the sky s cover. It was verified decrease mean values of relative deviation, when compared with the DRUMMOND s correction: 4,8% in cloudless sky, 4,66% in partially cloudy sky and, 4,6% in cloudy sky. The average relative deviation was 4,68%. The diffuse solar radiation measured on Cascavel-PR and corrected by RICIERI s numeric function, determined to region of Botucatu - SP, shows relative deviation to cloudy sky, partially cloudy sky and cloudless sky, respectively, 4,6%, 4,8% and 5,29%, suggesting that the functions developed to Botucatu - SP tend to be independent from the locality. / O presente estudo caracteriza o comportamento da radiação solar global, direta e difusa na cidade de Cascavel, classifica o tipo de cobertura do céu em função do índice de claridade e avalia a aplicabilidade da função numérica de RICIERI (1998) na correção da radiação solar difusa obtida com do anel de sombreamento. As componentes da radiação solar foram monitoradas durante o período de 3 de janeiro de 2001 a 14 de fevereiro de 2003 na Estação Experimental Agrometeorológica da UNIOESTE, Campus de Cascavel. Na medição da radiação global e difusa foi utilizado um piranômetro KIPP & ZONEN-CM3 e para medir a componente direta foi utilizado um pireliômetro EPPLEY-NIP acoplado a um rastreador solar. A radiação difusa foi monitorada de duas formas: através da diferença entre a radiação global e a radiação direta projetada no plano horizontal e através de um piranômetro sombreado por um anel. Os níveis médios mensais das irradiações global, direta na incidência e difusa, foram respectivamente, 51,8%, 31,7% e 20,17% da radiação incidente no topo da atmosfera. Os níveis da irradiação difusa medidos pelo método da diferença e anel de sombreamento corrigido pelo fator de DRUMMOND (1956) foram monitorados e comparados utilizando o desvio relativo diário. Foi verificado que, em 94% dos dias, a radiação difusa corrigida por DRUMMOND foi inferior à obtida pelo método padrão. Os desvios são maiores para dias de céu limpo (19,82%), que para céu parcialmente nublado (9,55%) ou nublado (2,68%). Foi empregado o método de correção sugerido por RICIERI (1998), que propõe a correlação entre a irradiação difusa sem correção e a irradiação difusa de referência, e a função numérica linear Rd=0,16545+1,21715R d foi proposta. Essa correlação melhora em cerca de 37% a correção da fração difusa, diminuindo o desvio relativo médio de 11,79%, calculado para o método de DRUMMOND, para 7,37%. As funções numéricas parciais, propostas em função do tipo de cobertura do céu, diminuem significativamente o valor do desvio relativo médio, quando comparada ao fator de correção de DRUMMOND: 4,80% para céu limpo, 4,66% para céu parcialmente nublado e 4,60% para céu nublado, sendo o desvio relativo médio igual a 4,68%. A radiação solar difusa medida em Cascavel - PR e corrigida com as funções numéricas de RICIERI, determinadas para a região do município de Botucatu - SP, mostraram desvios relativos médios para dias de céu nublado, parcialmente nublado e limpo, respectivamente, 4,60%, 4,80% e 5,29%, sugerindo que estas tendem a independer da localidade.
10

Comportamento e correção da radiação solar difusa obtida com o anel de sombreamento

Drechmer, Patricia Aparecida de Oliveira 01 August 2005 (has links)
Made available in DSpace on 2017-05-12T14:48:28Z (GMT). No. of bitstreams: 1 Patricia de Oliveira Drechmer.pdf: 703873 bytes, checksum: c5f64d1a8f42cf596ce9e2edd113b6b8 (MD5) Previous issue date: 2005-08-01 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This paper shows the comportment of solar radiation global, direct and diffuse radiation at Cascavel, classifies the sky s cover in function of the cloudiness index and studies the applicability of the numeric correction of RICIERI (1998) on diffuse radiation measured with a shadow ring. The research was done at meteorological experimental station of UNIOESTE, Cascavel. The solar radiation components were monitored from January 03, 2001 to February 14, 2003. The global radiation was monitored by a pyranometer KIPP & ZONEN-CM3 and the direct radiation were monitored by a pyrheliometer EPPLEY-NIP coupled to a solar tracer. The diffuse radiation was monitored by the difference between global radiation and direct radiation projected over the horizontal surface and by a pyranometer covered by a shadow ring. The monthly average levels of the global, direct and diffuse irradiations were 51,8%, 31,7% and 20,17% of the irradiation over the atmosphere s top. The diffuse irradiation measured by the difference method and by the shadow ring method corrected by DRUMMOND s factor and compared through the relative daily deviation. It was observed that, in 94% of the days, the diffuse radiation by DRUMMOND s factor was lower than the difference method. The deviations were higher for cloudless days (19,82%), than for partially cloudy days (9,55%) and cloudy days (2,68%). The RICIERI s correction (1998), that proposes the correlation of diffuse irradiation without correction with the diffuse irradiation by the difference method, was used and the linear function Rd=0,16545+1,21715R d was found to correct the diffuse by the shadow ring method. This correction increases the precision of the diffuse fraction obtained by shadow ring, decreasing the average relative deviation from 11,79%, when the DRUMMOND s correlation was applied, to 7,37%. In order to increase the model s precision, it was proposed the partial numeric equation fitted in function of the sky s cover. It was verified decrease mean values of relative deviation, when compared with the DRUMMOND s correction: 4,8% in cloudless sky, 4,66% in partially cloudy sky and, 4,6% in cloudy sky. The average relative deviation was 4,68%. The diffuse solar radiation measured on Cascavel-PR and corrected by RICIERI s numeric function, determined to region of Botucatu - SP, shows relative deviation to cloudy sky, partially cloudy sky and cloudless sky, respectively, 4,6%, 4,8% and 5,29%, suggesting that the functions developed to Botucatu - SP tend to be independent from the locality. / O presente estudo caracteriza o comportamento da radiação solar global, direta e difusa na cidade de Cascavel, classifica o tipo de cobertura do céu em função do índice de claridade e avalia a aplicabilidade da função numérica de RICIERI (1998) na correção da radiação solar difusa obtida com do anel de sombreamento. As componentes da radiação solar foram monitoradas durante o período de 3 de janeiro de 2001 a 14 de fevereiro de 2003 na Estação Experimental Agrometeorológica da UNIOESTE, Campus de Cascavel. Na medição da radiação global e difusa foi utilizado um piranômetro KIPP & ZONEN-CM3 e para medir a componente direta foi utilizado um pireliômetro EPPLEY-NIP acoplado a um rastreador solar. A radiação difusa foi monitorada de duas formas: através da diferença entre a radiação global e a radiação direta projetada no plano horizontal e através de um piranômetro sombreado por um anel. Os níveis médios mensais das irradiações global, direta na incidência e difusa, foram respectivamente, 51,8%, 31,7% e 20,17% da radiação incidente no topo da atmosfera. Os níveis da irradiação difusa medidos pelo método da diferença e anel de sombreamento corrigido pelo fator de DRUMMOND (1956) foram monitorados e comparados utilizando o desvio relativo diário. Foi verificado que, em 94% dos dias, a radiação difusa corrigida por DRUMMOND foi inferior à obtida pelo método padrão. Os desvios são maiores para dias de céu limpo (19,82%), que para céu parcialmente nublado (9,55%) ou nublado (2,68%). Foi empregado o método de correção sugerido por RICIERI (1998), que propõe a correlação entre a irradiação difusa sem correção e a irradiação difusa de referência, e a função numérica linear Rd=0,16545+1,21715R d foi proposta. Essa correlação melhora em cerca de 37% a correção da fração difusa, diminuindo o desvio relativo médio de 11,79%, calculado para o método de DRUMMOND, para 7,37%. As funções numéricas parciais, propostas em função do tipo de cobertura do céu, diminuem significativamente o valor do desvio relativo médio, quando comparada ao fator de correção de DRUMMOND: 4,80% para céu limpo, 4,66% para céu parcialmente nublado e 4,60% para céu nublado, sendo o desvio relativo médio igual a 4,68%. A radiação solar difusa medida em Cascavel - PR e corrigida com as funções numéricas de RICIERI, determinadas para a região do município de Botucatu - SP, mostraram desvios relativos médios para dias de céu nublado, parcialmente nublado e limpo, respectivamente, 4,60%, 4,80% e 5,29%, sugerindo que estas tendem a independer da localidade.

Page generated in 0.4634 seconds