Spelling suggestions: "subject:"bmonitoring."" "subject:"cemonitoring.""
201 |
Oberflächentemperaturmessungen als Methode des intraoperativen Monitorings einer endoskopisch-thorakalen Sympathikusausschaltung bei Hyperhidrosis palmo-axillarisKrämer, Sebastian 26 September 2013 (has links)
Objectives: Patients with hyperhidrosis suffer from an extreme perspiration that cannot be aligned with natural or situ- ational standards. Endoscopic sympathectomy is a meaningful option for palmar and axillary hyperhidrosis. A stan- dardized method of monitoring the immediate intraoperative success has not been established yet. The presented investigation shows one proposed sollution by monitoring skin surface temperature. The main aspect is to demonstrate a sig- nificant rise in temperature with utility for monitoring the immediate success of surgery. Methods: Twenty patients with primary hyperhidrosis were observed and treated in a standardized setting against a control group (n = 10). We obtained diverse data that permit determination of a point of time of measurement of surface temperature and definition of a degree of temperature variance. Results: After 5 minutes a significant change of 0.5 ̊ Celcius was noted on the palms; after 10 minutes on average 1.2 ̊ Celcius. Axillary temperature had significantly changed after 10 minutes with a mean temperature variation of 0.8 ̊ Celcius on the right side and 0.6 ̊ Celcius on the left side. Conclusions: Under consideration of appropriate time intervals of measurement and determined changes in surface temperature an early control of correct clip application in ETS is possible. In the palmar aspect an increase of 0.5 ̊ Celcius at an 5 minutes interval, and more than 1 ̊ Celcius at 10 minutes after placement of the clip as compared to basic values before application of the clip can be proposed.
|
202 |
Online circuit breaker monitoring systemDjekic, Zarko 15 May 2009 (has links)
Circuit breakers are used in a power system to break or make current flow through
power system apparatus. Reliable operation of circuit breakers is very important to the
well-being of the power system. Historically this is achieved by regular inspection and
maintenance of the circuit breakers. An automated online circuit breaker monitoring
system is proposed to monitor condition, operation and status of high and medium
voltage circuit breakers. By tracking equipment condition, this system could be used to
perform maintenance only when it is needed. This could decrease overall maintenance
cost and increase equipment reliability. Using high accurate time synchronization, this
system should enable development of system-wide applications that utilize the data
recorded by the system. This makes possible tracking sequence of events and making
conclusions about their effect on-line. This solution also enables reliable topology
analysis, which can be used to improve power flow analysis, state estimation and alarm
processing.
|
203 |
Robust Condition Monitoring and Fault Diagnosis of Variable Speed Induction Motor DrivesChoi, Seungdeog 2010 December 1900 (has links)
The main types of faults studied in the literature are commonly categorized as
electrical faults and mechanical faults. In addition to well known faults, the performance
of a diagnostic algorithm and its operational reliability in harsh environments has been
another concern.
In this work, the reliability of an electric motor diagnosis signal processing algorithm
itself is studied in detail under harsh industrial conditions. Reliability and robustness of
the diagnosis has especially been investigated under 1) potential motor feedback error;
2) noise interference to a diagnosis-relevant system; 3) ease of implementation; and 4)
universal application of diagnostic scheme in industry. Low cost and flexible
implementation strategies are also presented.
1) Signature-based diagnosis has been performed utilizing the speed feedback
information which is used to determine fault characteristic frequency. Therefore,
feedback information is required to maintain high accuracy for precise diagnosis which, in fact, is not the case in a practical industrial environment due to industrial noise
interferences. In this dissertation, the performance under feedback error is analyzed in
detail and error compensation algorithms are proposed.
2) Fault signatures are commonly small where the amplitude is continuously being
interfered with motor noise. Even though a decision is based on the signature, the
detection error will not be negligible if the signature amplitude is within or close to the
noise floor because the boundary noise level non-linearly varies and, hence, is quite
ambiguous. In this dissertation, the effect of noise interference is analyzed in detail and a
threshold design strategy is presented to discriminate potential noise content in diagnosis.
3) The compensating procedure of speed feedback errors and electrical machine
current noise, characteristics which are basically non-stationary random variables,
requires an exhaustive tracking effort. In this dissertation, the effective diagnosis
implementation strategy is precisely presented for digital signal processor (DSP) system
application.
4) Most of the diagnosis algorithms in the literature are developed assuming specific
detection conditions which makes application difficult for universal diagnosis purposes.
In this dissertation, by assuming a sinusoidal fault signal and its Gaussian noise contents,
a general diagnosis algorithm is derived which can be applied to any diagnostic scheme
as a basic tool.
|
204 |
Online circuit breaker monitoring systemDjekic, Zarko 10 October 2008 (has links)
Circuit breakers are used in a power system to break or make current flow through
power system apparatus. Reliable operation of circuit breakers is very important to the
well-being of the power system. Historically this is achieved by regular inspection and
maintenance of the circuit breakers. An automated online circuit breaker monitoring
system is proposed to monitor condition, operation and status of high and medium
voltage circuit breakers. By tracking equipment condition, this system could be used to
perform maintenance only when it is needed. This could decrease overall maintenance
cost and increase equipment reliability. Using high accurate time synchronization, this
system should enable development of system-wide applications that utilize the data
recorded by the system. This makes possible tracking sequence of events and making
conclusions about their effect on-line. This solution also enables reliable topology
analysis, which can be used to improve power flow analysis, state estimation and alarm
processing.
|
205 |
UH-1 corrosion monitoringKersten, Stephanie M. 19 November 2010 (has links)
As the UH-1 aircraft continue to age, there is growing concern for their structural integrity. With corrosion damage becoming a bigger part of the sustainment picture with increasing maintenance burden and cost, it is becoming increasingly important for corrosion management to be updated with more advanced techniques.
The current find-and-fix technique for handling corrosion has many shortfalls, spurring the recent interest in early detection through structural health monitoring. This condition based technique is becoming more prevalent and is recognized for the potential to greatly reduce maintenance cost. Through corrosion monitoring, structural and environmental conditions can be closely observed, preventing excessive maintenance action and saving cost.
Searches for corrosion monitoring system designs revealed several commercial companies with prototype systems installed on commercial aircraft, however, details on system design and data analysis were scarce. This study attempted to bridge the gap in literature by providing insight into the development of a corrosion damage prediction model and the design of a corrosion monitoring system.
This study attempted to use aircraft maintenance data to make prediction models for determining what corrosion damage an aircraft can expect, given varying operating conditions. Although a reliable prediction model could not be created, trends observed in the data were still valuable for identifying problematic areas of the aircraft. In order to create reliable models, more accurate corrosion data is needed. This can be accomplished through the implementation of a corrosion monitoring system.
A custom corrosion monitoring system was designed for the UH-1 aircraft. Commercial off-the-shelf products were fit to the design and a benefits-to-cost analysis was performed for the monitoring system, evaluating the system based on criteria developed from user requirements. The system proved to meet and exceed expectation, making it an ideal choice for the UH-1 aircraft.
|
206 |
Lokalaus tinklo incidentų monitoringo programinės įrangos projektavimas ir tyrimas / Design and analysis of local area network incidents monitoring softwareMorkūnas, Kęstutis 26 May 2006 (has links)
Monitoring is an important activity in daily local area network maintance routine. To be able to run the network efficiently and without incidents that run into problems, networks must be monitored. This way it is possible to detect and remove serious problems at early stages. Various techniques are employed, including monitoring and checking users actions, data traffic, active running processes, open ports and system log analysis. This thesis describes a method for engineering and implementing local area networks software and using it for field data analysis. In the process of writing this thesis such sample of software was created and aimed at the processes and event logs of Kaunas University of Technology Software Engineering Department. In the conclusion methods and ways that will help solve current problems were suggested. Most alarming thing to notice was constant port scans and illegal attempts to log into the system without permission.
|
207 |
Antibiotika-Verbrauchsmengenerfassung bei landwirtschaftlichen Nutztieren in ausgewählten Betrieben und Tierarztpraxen in Niedersachsen und Nordrhein-Westfalen unter Berücksichtigung pharmakologischer Parameter / Pharmacological aspects of monitored consumption of antibiotics of agricultural animals in selected farms and veterinary surgeries in Lower Saxony and Northrhine-WestfaliaRobanus, Matthias 23 August 2011 (has links) (PDF)
Richtlinie 2003/99/EG des Europäischen Parlaments und des Rates legt das Ziel für die Mitgliedsstaaten fest, ein Monitoring von Antbiotikaresistenzen bei Zoonoserregern zu implementie-ren. Da die Menge verabreichter antimikrobieller Wirkstoffe im direkten Zusammenhang mit der Entwicklung von Resistenzen steht, impliziert diese Richtlinie auch die Menge der in Nutztierbeständen eingesetzten antimikrobiellen Wirkstoffe zu erfassen und zu überwachen. Zielsetzung dieser Arbeit war es, im Rahmen des Projekts VetCAb die Möglichkeiten der Datenerhebung von Verbrauchsmengen von Antibiotika bei landwirtschaftlichen Nutztieren aus gesetzlich vorge-schriebenen Nachweisen (Tierärztlicher Anwendungs- und Abgabebeleg nach §13 TÄHAV, Bestandsbuch nach ANTHV) in Tierarztpraxen bzw. landwirtschaftlichen Betrieben zu untersuchen und hinsichtlich pharmakologischer Parameter zu bewerten.
Am Projekt VetCAb (Veterinary Consumption of Antibiotics) nahmen 24 tierärztliche Praxen aus fünf Landkreisen Niedersachsens (Cloppenburg, Diepolz, Emsland, Nienburg, Vechta) sowie 66 landwirtschaftliche Betriebe im Landkreis Kleve (Nordrhein-Westfalen) freiwillig teil. Daten vom Zeitraum eines Jahres (01. September 2006 – 31. August 2007) wurden erfasst und in einer zentralen Datenbank abgelegt. Für die Auswertung standen zudem epidemiologische Daten zur Vieh- und Betriebsdichte (Easystat® 2007) sowie weitergehende Informationen der zuständigen Veterinärämter der betroffenen Landkreise (HEGGER-GRAVENHORST 2010, MOLLENHAUER 2010) zur Verfügung.
Insgesamt wurden 74.427 Datensätze erhoben, von denen ein Anteil von 4,18 % (entsprechend 3.114 Datensätze) als nicht-plausibel gekennzeichnet war. 68.565 Datensätze entstammten dabei der Erhebung in Praxen, 5,862 der in landwirtschaftlichen Betrieben, was einem geometrischen Mittel von 2743 Datensätzen pro Praxis bzw. 58 pro landwirtschaftlichen Betrieb entspricht. Im Rinder- als auch im Schweinebereich wurden Tetracycline mit rund 50 % der verbrauchten Mengen am häufigsten eingesetzt, β-Lactame lagen dabei auf dem zweiten Rang. Bezüglich der Betrachtung der Zahl der Einzelgaben war eine Abnahme des Verbrauchs von Tetracyclinen zu-gunsten eines Anstiegs von Makroliden und Trimethoprim (inclusive Trimetoprim/Sulfonamide) zu verzeichnen. Bezüglich des Einsatzes von Antiinfektiva wurden die Diagnosegruppen Atemwegserkrankungen (69,21 % beim Rind, 58,86 % beim Schwein, Geflügel 34,90 %) und Darmer-krankungen (4,57 % beim Rind, 14,91 % beim Schwein, Geflügel 50,12 %) am häufigsten angegeben. Die Darreichung auf oralem Wege stellte mit 81,20 % der eingesetzten Gesamtmenge beim Rind, 94,24 % beim Schwein und 99,34 % beim Geflügel die häufigste Applikationsform dar (v.a. Tetracycline, β-Lactame, Makrolide oder Sulfonamide).
Im Vergleich der eingesetzten Dosierung mit der festgelegten Richtdosierung (mg/kg) lagen beim Rind bzw. Schwein insgesamt 23,10 % bzw. 23,73 % unter, 36,13 % bzw. 47,31 % über und 44,77 % bzw. 28,95 % innerhalb der Richtdosierung.
Mit der im Projekt VetCAb durchgeführten Untersuchung zur Durchführbarkeit und Etablierung eines Verbrauchsmengenmonitorings in der Nutztierhaltung konnten grundlegende Erkenntnisse aufgezeigt werden, wobei Aspekte der Datenerfassung, der Pharmakologie, der Epidemiologie und der arzneimittelrechtlichen Rahmenbedingungen berücksichtigt wurden. Die Möglichkeiten überstiegen darüber hinaus die im Arzneimittelgesetz in § 47 Abs. 1b und DIMDI - Arzneimittel-verordnung dargelegten Anforderungen eines Antibiotikaverbrauchsmengenerfassungsprogramms, welches lediglich die Verkaufszahlen antimikrobieller Wirkstoffe auf Seiten des pharmazeutischen Unternehmers erfassen kann und damit keine Rückschlüsse auf den Antibiotikaeinsatz bei der jeweiligen Zieltierart gezogen werden können. Im Projekt Vet-CAb wurden die Verbrauchsmengen des freien Wirkstoffs getrennt nach Tierarten und Alters- bzw. Nutzungsrichtungen sowie nach Art der Applikation bei landwirtschaftlichen Nutztieren erfasst. Ferner kann das Dosierungsverhalten durch das Festsetzen von Richtdosen abgeleitet werden. Zudem besteht die Möglichkeit tagesaktuelle Verbrauchsmengen über eine online verfügbare Datenbank abzufragen. Aufgrund der zahlreichen Auswertungsmöglichkeiten ist das Er-fassungssystem in der Lage wissenschaftlich fundierte Daten über den Antibiotikaverbrauch bei landwirtschaftlichen Nutztieren zu liefern, die als sinnvolle Ergänzung zu Resistenzmonitoring-Systemen betrachtet werden können. Auch eine Vergleichbarkeit der erfassten Verbrauchsmen-gen mit den Daten aus Verbrauchsmengenmonitoringprogrammen anderer europäischer Länder ist gegeben. Vorraussetzung hierfür ist eine Festlegung standadisierter Auswertungsparameter für die europäischen Länder. Diese Vergleichbarkeit der Datenströme und der Ausbau vergleichbarer Arzneimittelklassifikationssysteme ist als Bestandteil präventiven Risikomanagements (PASCH et al. 2005, HELMUTH und HENSEL 2006) ein erstrebenswertes Ziel. In der vorliegenden Machbarkeitsstudie konnte gezeigt werden, dass das untersuchte Konzept diesen Anforderungen prinzipiell genügt und auch zukünftigen Anforderungen an eine Verbrauchsmengenerfassung von Antibiotika bei landwirtschaftlichen Nutztieren aus wissenschaftlicher Sicht standhalten kann.
|
208 |
A study of carbon monoxide exposure in selected populations in Hong Kong /Wu, Wai-yin, Helen. January 1994 (has links)
Thesis (M. Sc.)--University of Hong Kong, 1994. / Includes bibliographical references (leaves 69-75).
|
209 |
Air quality monitoring in Hong Kong /Fong, Kin-wa. January 1900 (has links)
Thesis (M. Sc.)--University of Hong Kong, 1993.
|
210 |
Evaluation of accuracy of four blood glucose monitoring systems /Berkat, Kim S. January 1900 (has links)
Thesis (M.S.)--University of Missouri--Columbia, 1995. / "May 1995." Typescript. Includes bibliographical references (leaves 35-37). Also available on the Internet.
|
Page generated in 0.085 seconds