• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

An?lise de motobombas submersas com diferentes acionamentos el?tricos a partir da Roda de Falhas / Analysis of submersible motor pumps with different electric drives from the Failure Wheel

Pereira, Leandro Luiz da Silva 29 December 2016 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-07-03T13:37:23Z No. of bitstreams: 1 LeandroLuizDaSilvaPereira_DISSERT.pdf: 10051425 bytes, checksum: 2c83b499adde5859560e54458c90cb2c (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-07-07T12:37:13Z (GMT) No. of bitstreams: 1 LeandroLuizDaSilvaPereira_DISSERT.pdf: 10051425 bytes, checksum: 2c83b499adde5859560e54458c90cb2c (MD5) / Made available in DSpace on 2017-07-07T12:37:13Z (GMT). No. of bitstreams: 1 LeandroLuizDaSilvaPereira_DISSERT.pdf: 10051425 bytes, checksum: 2c83b499adde5859560e54458c90cb2c (MD5) Previous issue date: 2016-12-29 / Evitar falhas ? uma medida extremamente necess?ria quando se gerencia sistemas de produ??o e distribui??o de ?gua com 95% das redes pressurizadas diretamente por po?os. Baseado nas frequentes faltas de ?gua em 2015, registradas pela CAERN na Unidade de Opera??o e Manuten??o de ?guas de Parnamirim (UNAP), destacam-se as avarias causadas por sobreaquecimento e outros danos de natureza mec?nica e el?trica que levam a falhas nas instala??es de motobombas submersas. Nesse escopo, este trabalho foi dedicado a realizar um estudo de caso sobre as instala??es de quatro motobombas dos po?os PC, PD, PS e PI, com diferentes acionamentos el?tricos, utilizando a proposta da Roda de Falhas (Failure Wheel) numa an?lise preditiva el?trica e termogr?fica, para inferir qualitativamente sobre o n?vel de confiabilidade e custo de manuten??o na concession?ria de abastecimento d??gua. Para subsidiar as an?lises foram inspecionados itens importantes das referidas instala??es, observando suas rela??es de conformidade com as especifica??es das motobombas, onde foram efetuadas medi??es de par?metros el?tricos e t?rmicos de opera??o, incluindo vari?veis de estresse para auxiliar no diagn?stico e estimar os desempenhos dessas m?quinas. A an?lise foi conduzida por ficha de inspe??o de par?metros operacionais, checklist e pela Roda de Falhas em discuss?o, que permitiram diagn?sticos sobre os dados das inspe??es e do hist?rico de falhas recorrentes. Nesse sentido, a aplica??o da Roda de Falhas se deu com a adapta??o de um modelo para as motobombas submersas, identificando os principais mecanismos de danos associados ?s causas gerais de falhas, que demonstrou viabilidade em rotinas de manuten??o baseada na condi??o para an?lise detectiva-preditiva de falhas em curso nos equipamentos. Comparando o consumo espec?fico de energia entre as motobombas, a PI, com acionamento por inversor de frequ?ncia, obteve melhor rendimento, oferecendo maior efici?ncia energ?tica durante a capta??o d??gua entre julho de 2015 e julho de 2016. A mesma demonstrou risco reduzido de falhas t?picas de motobombas dentre os equipamentos, tendo em vista o menor n?vel t?rmico em opera??o apresentado nas termografias, e o menor estresse causado devido ?s caracter?sticas da chave de partida. Conclui-se, portanto, que seu n?vel de confiabilidade foi o maior, seguido da PS, PC e PD. As vantagens da aplica??o sistem?tica da proposta, aliada a uma pol?tica de manuten??o planejada, apontam para a redu??o de intercorr?ncias por falhas e perdas de produ??o, e com isso, permitem diminuir trocas prematuras de equipamentos e custos com manuten??o e energia el?trica. Como resultado da pesquisa obteve-se uma metodologia de acompanhamento preditivo, visando a??es de manuten??o antes da falha catastr?fica sobre itens em percurso de danos. / Avoiding failures is an extremely necessary measure when managing water production and distribution systems with 95% of networks pressurized directly by wells. Based on the frequent water shortages in 2015, registered by CAERN at the Parnamirim Water Operation and Maintenance Unit (UNAP), the most notable are the damages caused by overheating and other mechanical and electrical damages that lead to failures in the motor pump Submerged. In this scope, this work was carried out to carry out a case study on the installations of four well pumps PC, PD, PS and PI, with different electric drives, using the Failure wheel proposal in an electric predictive analysis And thermographic, to qualitatively infer about the level of reliability and cost of maintenance in the water supply concessionaire. In order to subsidize the analyzes, important items of the aforementioned facilities were inspected, observing their relations of conformity with the specifications of the pumps, where electrical and thermal parameters of operation were carried out, including stress variables to aid in the diagnosis and to estimate the performances of these machines. The analysis was carried out by a checklist of operational parameters, checklist and by Failure Wheel in discussion, which allowed for diagnoses on inspection data and the history of recurring faults. In this sense, the application of the Failure Wheel occurred with the adaptation of a model for the submersible pumps, identifying the main damage mechanisms associated to the general causes of failures, which demonstrated viability in maintenance routines based on the condition for detective-predictive analysis of faults in the equipment. Comparing the specific energy consumption between the pumps, the PI, with drive by frequency inverter, obtained better efficiency, offering greater energy efficiency during the water harvest between July 2015 and July 2016. It showed a reduced risk of failure Typical of motor pumps, among the equipment, considering the lower thermal level in operation presented in thermographs, and the lower stress caused due to the characteristics of the starter. It was concluded, therefore, that its reliability level was the highest, followed by PS, PC and PD. The advantages of the systematic application of the proposal, coupled with a planned maintenance policy, point to the reduction of intercurrences due to failures and losses of production, and with this, allow to reduce premature equipment changes and costs with maintenance and electric energy. As a result of the research, a methodology of predictive monitoring was obtained, aiming at maintenance actions before the catastrophic failure on items in the course of damages.
2

Avaliação de sistemas fotovoltaicos de bombeamento / Evaluation of Photovoltaic Pumping Systems

Melendez, Teddy Arturo Flores 22 April 2009 (has links)
A presente dissertação aborda a avaliação de três sistemas fotovoltaicos de bombeamento, que compreendem duas configurações com equipamentos dedicados à tecnologia fotovoltaica e um com equipamentos alternativos com potências entre 0,75 CV e 1,0 CV. Os resultados mostram que a configuração alternativa apresenta menor eficiência diária do sistema motobomba. A avaliação econômica revela a competitividade da configuração alternativa frente aos sistemas importados dedicados à tecnologia fotovoltaica. Alia-se a isso a disponibilidade dos equipamentos de condicionamento de potência e a facilidade de reposição. Verificou-se também que a configuração alternativa, conversor de freqüência WEG CFW08 e motobomba SOMAR de 1,0 CV e 8 estágios, trabalha com eficiência diária próxima aos 30% na faixa de operação de 20 a 40 metros de coluna dágua. Portanto, com uma adequada escolha da motobomba para a configuração alternativa, podem-se obter desempenhos semelhantes aos obtidos com sistemas importados dedicados à tecnologia fotovoltaica. Para 30 metros, a configuração alternativa bombeou somente 1% a menos do que o sistema Grundfos. O custo do volume bombeado para 30m de altura manométrica total do sistema alternativo é 22% menor do que o sistema Grundfos e 51% mais econômico do que o sistema Solarjack (Sun Pumps). / The present dissertation shows the evaluation of three Photovoltaic Pumping Systems, which involves two configurations: the equipment dedicated to the photovoltaic technology and the alternative equipment with nominal powers between 0.75 CV and 1.0 CV. The results show that the alternative configuration attained minor daily efficiency of the motopump system. The economic evaluation reveals the competitiveness of the alternative configuration in comparison with imported photovoltaic technology dedicated systems. It also should be considered the availability of equipment for power conditioning and the facility of replacement. It was also verified that the alternative configuration, variable speed drive WEG CFW08 and 1.0 CV SOMAR motor pump with 8 stages, works with daily efficiency near 30% in the 20 to 40 meters operation range. Therefore, with an adequate choice of the motor pump for the alternative configuration, performances similar to the imported photovoltaic technology dedicated systems can be obtained. For 30 meters, the alternative configuration pumped only 1% less than the Grundfos system. The cost of pumped volume for 30 meters of manometer total height of the alternative system is 22% cheaper than the system Grundfos and 51% cheaper than the system Solarjack (Sun Pumps).
3

Avaliação de sistemas fotovoltaicos de bombeamento / Evaluation of Photovoltaic Pumping Systems

Teddy Arturo Flores Melendez 22 April 2009 (has links)
A presente dissertação aborda a avaliação de três sistemas fotovoltaicos de bombeamento, que compreendem duas configurações com equipamentos dedicados à tecnologia fotovoltaica e um com equipamentos alternativos com potências entre 0,75 CV e 1,0 CV. Os resultados mostram que a configuração alternativa apresenta menor eficiência diária do sistema motobomba. A avaliação econômica revela a competitividade da configuração alternativa frente aos sistemas importados dedicados à tecnologia fotovoltaica. Alia-se a isso a disponibilidade dos equipamentos de condicionamento de potência e a facilidade de reposição. Verificou-se também que a configuração alternativa, conversor de freqüência WEG CFW08 e motobomba SOMAR de 1,0 CV e 8 estágios, trabalha com eficiência diária próxima aos 30% na faixa de operação de 20 a 40 metros de coluna dágua. Portanto, com uma adequada escolha da motobomba para a configuração alternativa, podem-se obter desempenhos semelhantes aos obtidos com sistemas importados dedicados à tecnologia fotovoltaica. Para 30 metros, a configuração alternativa bombeou somente 1% a menos do que o sistema Grundfos. O custo do volume bombeado para 30m de altura manométrica total do sistema alternativo é 22% menor do que o sistema Grundfos e 51% mais econômico do que o sistema Solarjack (Sun Pumps). / The present dissertation shows the evaluation of three Photovoltaic Pumping Systems, which involves two configurations: the equipment dedicated to the photovoltaic technology and the alternative equipment with nominal powers between 0.75 CV and 1.0 CV. The results show that the alternative configuration attained minor daily efficiency of the motopump system. The economic evaluation reveals the competitiveness of the alternative configuration in comparison with imported photovoltaic technology dedicated systems. It also should be considered the availability of equipment for power conditioning and the facility of replacement. It was also verified that the alternative configuration, variable speed drive WEG CFW08 and 1.0 CV SOMAR motor pump with 8 stages, works with daily efficiency near 30% in the 20 to 40 meters operation range. Therefore, with an adequate choice of the motor pump for the alternative configuration, performances similar to the imported photovoltaic technology dedicated systems can be obtained. For 30 meters, the alternative configuration pumped only 1% less than the Grundfos system. The cost of pumped volume for 30 meters of manometer total height of the alternative system is 22% cheaper than the system Grundfos and 51% cheaper than the system Solarjack (Sun Pumps).

Page generated in 0.0249 seconds