• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Fatigue in chronically critically ill patients following intensive care - reliability and validity of the multidimensional fatigue inventory (MFI-20)

Wintermann, Gloria-Beatrice, Rosendahl, Jenny, Weidner, Kerstin, Strauß, Bernhard, Hinz, Andreas, Petrowski, Katja 12 June 2018 (has links) (PDF)
Background Fatigue often occurs as long-term complication in chronically critically ill (CCI) patients after prolonged intensive care treatment. The Multidimensional Fatigue Inventory (MFI-20) has been established as valid instrument to measure fatigue in a wide range of medical illnesses. Regarding the measurement of fatigue in CCI patients, the psychometric properties of the MFI-20 have not been investigated so far. Thus, the present study examines reliability and validity of the MFI-20 in CCI patients. Methods A convenience sample of n = 195 patients with Critical Illness Polyneuropathy (CIP) or Myopathy (CIM) were recruited via personal contact within four weeks (t1) following the transfer from acute care ICU to post-acute ICU at a large rehabilitation hospital. N = 113 (median age 61.1 yrs., 72.6% men) patients were again contacted via telephone three (t2) and six (t3) months following the transfer to post-acute ICU. The MFI-20, the Euro-Quality of Life (EQ-5D-3 L) and the Structured Clinical Interview for the Diagnostic and Statistical Manual of mental disorders DSM-IV (SCID-I) were applied within this prospective cohort study. Results The internal consistency Cronbach’s α was adequate for the MFI-total and all but the subscale Reduced Motivation (RM) (range: .50–.91). Item-to-total correlations (range: .22–.80) indicated item redundancy for the subscale RM. Confirmatory Factor analyses (CFAs) revealed poor model fit for the original 5-factor model of the MFI-20 (t2/t3, Confirmatory Fit Index, CFI = .783/ .834; Tucker-Lewis Index, TLI = .751/ .809; Root Mean Square Error of Approximation, RMSEA = .112/ .103). Among the alternative models (1-, 2-, 3-factor models), the data best fit to a 3-factor solution summarizing the highly correlated factors General −/ Physical Fatigue/ Reduced Activity (GF/ PF/ RA) (t2/ t3, CFI = .878/ .896, TLI = .846/ .869, RMSEA = .089/ .085, 90% Confidence Interval .073–.104/ .066–.104). The MFI-total score significantly correlated with the health-related quality of life (range: −.65-(−).66) and the diagnosis of major depression (range: .27–.37). Conclusions In the present sample of CCI patients, a reliable and valid factor structure of the MFI-20 could not be ascertained. Especially the subscale RM should be revised. Since the factors GF, PF and RA cannot be separated from each other and the unclear factorial structure in the present sample of CCI patients, the MFI-20 is not recommended for use in this context.
2

Fatigue in chronically critically ill patients following intensive care - reliability and validity of the multidimensional fatigue inventory (MFI-20)

Wintermann, Gloria-Beatrice, Rosendahl, Jenny, Weidner, Kerstin, Strauß, Bernhard, Hinz, Andreas, Petrowski, Katja 12 June 2018 (has links)
Background Fatigue often occurs as long-term complication in chronically critically ill (CCI) patients after prolonged intensive care treatment. The Multidimensional Fatigue Inventory (MFI-20) has been established as valid instrument to measure fatigue in a wide range of medical illnesses. Regarding the measurement of fatigue in CCI patients, the psychometric properties of the MFI-20 have not been investigated so far. Thus, the present study examines reliability and validity of the MFI-20 in CCI patients. Methods A convenience sample of n = 195 patients with Critical Illness Polyneuropathy (CIP) or Myopathy (CIM) were recruited via personal contact within four weeks (t1) following the transfer from acute care ICU to post-acute ICU at a large rehabilitation hospital. N = 113 (median age 61.1 yrs., 72.6% men) patients were again contacted via telephone three (t2) and six (t3) months following the transfer to post-acute ICU. The MFI-20, the Euro-Quality of Life (EQ-5D-3 L) and the Structured Clinical Interview for the Diagnostic and Statistical Manual of mental disorders DSM-IV (SCID-I) were applied within this prospective cohort study. Results The internal consistency Cronbach’s α was adequate for the MFI-total and all but the subscale Reduced Motivation (RM) (range: .50–.91). Item-to-total correlations (range: .22–.80) indicated item redundancy for the subscale RM. Confirmatory Factor analyses (CFAs) revealed poor model fit for the original 5-factor model of the MFI-20 (t2/t3, Confirmatory Fit Index, CFI = .783/ .834; Tucker-Lewis Index, TLI = .751/ .809; Root Mean Square Error of Approximation, RMSEA = .112/ .103). Among the alternative models (1-, 2-, 3-factor models), the data best fit to a 3-factor solution summarizing the highly correlated factors General −/ Physical Fatigue/ Reduced Activity (GF/ PF/ RA) (t2/ t3, CFI = .878/ .896, TLI = .846/ .869, RMSEA = .089/ .085, 90% Confidence Interval .073–.104/ .066–.104). The MFI-total score significantly correlated with the health-related quality of life (range: −.65-(−).66) and the diagnosis of major depression (range: .27–.37). Conclusions In the present sample of CCI patients, a reliable and valid factor structure of the MFI-20 could not be ascertained. Especially the subscale RM should be revised. Since the factors GF, PF and RA cannot be separated from each other and the unclear factorial structure in the present sample of CCI patients, the MFI-20 is not recommended for use in this context.

Page generated in 0.1071 seconds