• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etude de stratégies de ventilation pour améliorer la qualité environnementale intérieure et le confort des occupants en milieu scolaire / Study of ventilation strategies improving indoor environmental quality and comfort in scholar buildings

Dhalluin, Adrien 19 June 2012 (has links)
La ventilation est un secteur clé du bâtiment, dont le rôle est d’assurer un air sain et confortable toute l’année, ce qui est rarement le cas dans les bâtiments scolaires, tout en minimisant les consommations énergétiques. Nos travaux consistent à apporter des éléments de réponses et des pistes d’amélioration pour l’élaboration de stratégies de ventilation appropriées au milieu scolaire, à partir de travaux expérimentaux et numériques. Pour ce faire, quatre modes de ventilation (naturelle et mixte) ont été testés dans des salles de classes de l’Université de La Rochelle, et leurs performances ont été comparées via une évaluation multicritère basée sur les paramètres physiques caractérisant l’environnement intérieur, les indices de confort (subjectif, analytique et adaptatif) et des critères énergétiques. Des méthodes normatives de classification et des estimations de consommations énergétiques nous ont permis de conclure, que le système de ventilation naturelle par ouverture automatisée des fenêtres, contrôlé par la détection de présence et des paramètres thermiques (système SOS), est le meilleur compromis. Nous soumettons toutefois dans ce manuscrit, un certain nombre d’améliorations à apporter à ce système.Notre contribution porte également sur la connaissance des mécanismes du confort humain et en particulier ses réactions adaptatives, en définissant les conditions favorables au confort et en proposant des modèles prédictifs du confort global, de l’ajustement personnel ainsi que du contrôle individuel de l’ambiance par les occupants. Ces résultats ont notamment pour vocation d’améliorer la prise en compte des interactions entre les occupants et leur environnement dans les simulations numériques et pourraient également servir de base au développement d’une stratégie de ventilation optimisée. Au niveau numérique, nous proposons des simulations annuelles de quatre stratégies de ventilation, très proches de celles testées sur site, à l’aide d’un code thermo-aéraulique multizone (couplage Trnsys/Contam), que nous avons validé à partir de certaines séquences de mesures. En tenant compte d’un scénario d’occupation scolaire standard et du fichier météorologique correspondant à la station de La Rochelle, nous avons notamment montré qu’il est primordial de pré-chauffer l’air d’un système de ventilation mécanique, sous peine d’être confronté à des besoins de chauffage insurmontables. En introduisant une puissance de chauffage illimitée, permettant de maintenir une température minimale acceptable et ainsi de simuler des conditions d’enseignement réalistes, il apparaît que la meilleure qualité environnementale intérieure est à nouveau obtenue avec le système SOS. Notre modèle nous donne désormais la possibilité de multiplier les stratégies de ventilation, ainsi que les scénarios d’occupation, les conditions climatiques ou tout autre étude paramétrique, afin d’élaborer les meilleures stratégies de ventilation dans chaque configuration. / Ventilation is a key sector of building, whose role is to ensure healthy and comfortable air all over the year, which is rarely the case in school buildings, while minimizing energy consumption. Our work provides some answers and possible improvements for the development of appropriate ventilation strategies for schools, from experimental and numerical work.To achieve this, four modes of ventilation (natural and mixed ventilation modes) were tested in classrooms of the University of La Rochelle, and their performances were compared via a multicriteria evaluation based on the physical parameters characterizing the indoor environment, comfort indices (subjective, analytical and adaptive) and energy criteria. Normative methods of classification and estimates of energy consumption enabled us to conclude that the natural ventilation system by automated opening windows, controlled by the presence detection and thermal parameters (SOS), is the best compromise. However, we submit in this manuscript, some improvements to this system.Our contribution concerns also the understanding of the human comfort mechanisms and in particular its adaptive reactions, by defining the favorable conditions for a state of comfort and providing predictive models concerning overall comfort, personal adjustments and the individual control of the indoor environment by the occupants. These results aim to improve the consideration of the interactions between occupants and their environment in numerical simulations, and may serve as a basis for developing an optimized ventilation strategy.Numerically, we propose annual simulations of four ventilation strategies, very similar to those tested in situ, by using a combined heat and mass transfer multizone model (coupling Trnsys / CONTAM), that we have validated from selected experimental sequences. Taking into account a standard scenario of occupation and the annual weather conditions for La Rochelle, we have shown the importance to pre-heat the supplied air of a mechanical ventilation system, because of insurmountable heating demand consequences. By introducing an unlimited heating power, in order to maintain a minimum acceptable temperature and thus to simulate realistic learning conditions, it appears that the best indoor environmental quality is again obtained with the SOS system. Our model now gives us the possibility to increase the number of ventilation strategies, as well as the occupation scenarios, the weather conditions or any other parametric study in order to design the best ventilation strategies for each configuration.
2

Etude expérimentale et numérique des performances de la ventilation mécanique par insufflation : qualité de l’air intérieur dans les bâtiments résidentiels / Experimental and numerical study of the supply-only ventilation system performances : indoor air quality in residential buildings

Rahmeh, Mireille 04 July 2014 (has links)
La mauvaise qualité de l'air intérieur a été classée parmi les cinq principaux risques environnementaux sur la santé publique (EPA, 2013). La ventilation est une solution bien connue pour réduire la variété de contaminants qui pourraient être trouvés à l'intérieur de bâtiments résidentiels. Cependant, comme l'air propre est un facteur essentiel pour une vie saine et un bâtiment sain, une faible consommation d'énergie est essentielle pour une planète saine. Pour ces raisons, différentes recherches scientifiques sont menées pour l'amélioration des performances des systèmes de ventilation afin de créer un équilibre entre la distribution de l'air et la qualité de l'air intérieur d’un côté et le confort thermique et l'efficacité énergétique d’un autre côté. Un des systèmes de ventilation existants est la ventilation mécanique par insufflation (VMI). Son principe consiste à introduire mécaniquement de l’air neuf depuis l’extérieur, après l’avoir filtré et préchauffé. Les systèmes existant à ce jour en France introduisent l’air via un ou deux points d’insufflation (situés généralement au centre de l’habitation). Quant à l'évacuation de l’air vicié, celui-ci est véhiculé par les sorties naturelles installées dans chaque pièce de la maison. L’objectif de ce travail est tout d’abord d’étudier les performances de la ventilation par insufflation dans un environnement réel puis de trouver des pistes d’amélioration qui permettront d’atteindre une meilleure qualité de l’air intérieur. En se basant sur deux études préliminaires présentées par le chapitre II, on a installé un système à insufflation répartie (un point d’insufflation/pièce de vie) dans une maison réelle où l’on a mené des expérimentations. Des scénarios d’émission de polluant ont été effectués à l’aide de la technique de gaz traceur. L’étude a montré que, malgré un débit de ventilation global du système VMI inférieur à celui du système de référence (ventilation mécanique par extraction hygroréglable B), la VMI fournit des résultats satisfaisants. En outre, elle aide à lutter contre le confinement des chambres et à réduire à l'intérieur, les concentrations des particules provenant des sources extérieures. Une étude numérique est réalisée en utilisant un modèle aéraulique et de transfert de masse multizone. Les résultats ont montré un bon accord avec l'expérience et sont prometteurs pour l’avenir ; une étude paramétrique permettant d'améliorer la performance de la VMI vient parachever ce travail. / Poor indoor air quality has been ranked among the top five environmental risks on public health (EPA, 2013). The ventilation is a well-recognized solution for reducing the variety of contaminants that could be found inside residential buildings. However, as well as clean air is an essential factor for a healthy life and a healthy building, low energy consumption is significant for a healthy planet. For these reasons, scientific research are conducted to improve the performance of ventilation systems in order to obtain a balance in the controversial relationship between the air distribution and indoor air quality on the one hand and the thermal comfort and energy efficiency on the other hand. One of the existing ventilation systems is the Supply-Only Ventilation (SOV), known also as positive input ventilation (PIV). It functions by mechanically introducing fresh, filtered and preheated air into the center of the building. So far, the existing systems in France introduce air through one or two supply points (usually located in the center of the house). As for the evacuation, steal air goes out through natural vents installed in each room of the house. The aim of this study is to evaluate the performance of this system in terms of indoor air quality in a real environment and to find improvement field that will help in increasing the indoor air quality. Based on preliminary studies and on the airflow path principle required by French regulation, we decided to investigate a Multi Supply-Only Ventilation system (M-SOV). The idea is to have an insufflation point in the bedrooms and living room, while the free air outlets are located in the utility rooms (kitchen, bathroom and toilets). Different emission scenarios are experimentally simulated using tracer gas methods. The study shows that even though the flow rate of this system is lower than the extract only ventilation system (EOV), it provides satisfactory results. In addition, it helps fight against the confinement room and reduce the indoor particles concentrations originated from outdoor sources. A numerical study using a multizone airflow and contaminant transport model is performed. The numerical results show a good agreement with that of the experimental ones. Moreover, they are promising for the future parametric study in order to improve the SOV performance.

Page generated in 0.058 seconds