• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • 15
  • 14
  • 14
  • 3
  • Tagged with
  • 71
  • 71
  • 24
  • 12
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Impulsivität und Antworthemmung bei adulter Aufmerksamkeitsdefizit- und Hyperaktivitätsstörung (ADHS) / Impulsivity and response inhibition in adult attention-deficit/hyperactivity disorder (ADHD)

Melber, Makito Bernhard January 2012 (has links) (PDF)
Ziel der vorliegenden, experimentellen Arbeit war die Untersuchung der Persönlichkeitseigenschaft der Impulsivität bei adulten Patienten mit ADHS und vergleichbaren Versuchspersonen. Da die Ätiopathogenese erhöhter Impulsivität bei Patienten mit ADHS bislang ungeklärt ist, eine Beeinflussung des dopaminergen Systems durch vorausgehende Studien allerdings nahe liegt, wurden die verwendeten Impulsivitätsmessungen zusätzlich bezüglich einer möglichen Beeinflussung durch den Val158Met-COMT-Polymorphismus analysiert. Die Untersuchung beinhaltet mit 71 adulten Patienten mit ADHS und 54 gesunden Kontrollpersonen, die nach Alter, Geschlecht, IQ, Kopfumfang und Händigkeit vergleichbar waren, eine der aktuell größten Stichproben adulter Patienten mit ADHS. Während einer Stoppsignal-Aufgabe zur Erfassung der Antworthemmungsfähigkeit als Korrelat der Impulsivität wurden die Verhaltensdaten der Stichproben sowie die hirnphysiologischen Veränderungen mittels funktioneller Nahinfrarotspektroskopie aufgezeichnet und ausgewertet. Die erhobenen experimentellen Daten wurden anschließend mit selbstbewerteter Impulsivität des I7-Impulsivitätsfragebogens nach Eysenck verglichen und auf mögliche Zusammenhänge überprüft. Zudem wurden die beobachteten Ergebnisse der vorliegenden Arbeit auf einen möglichen Einfluss durch den Val158Met-COMT-Polymorphismus untersucht. Auf der Verhaltensebene zeigten Patienten mit ADHS im Vergleich zu gesunden Kontrollpersonen sowohl für die SSRZ als auch für die Go-RZ signifikant langsamere Reaktionszeiten. Im Vergleich der funktionellen Daten konnten für Patienten mit ADHS während der erfolgreichen Stopp-Trials signifikant bzw. tendenziell verminderte Aktivierungen im Bereich des IFC und DLPFC in beiden Hemisphären festgestellt werden. Die Untersuchung der selbstbewerteten Impulsivität anhand des I7-Fragebogens ergab ebenfalls einen signifikanten Unterschied zwischen den beiden Stichproben. Bezüglich der Zusammenhänge zwischen den einzelnen Impulsivitätsmessungen konnten für Patienten mit ADHS signifikant bzw. tendenziell negative Zusammenhänge zwischen SSRZ und Oxygenierung im rechten IFC sowie zwischen SSRZ bzw. Go-RZ und I7-Impulsivitätswerten festgestellt werden. In der Untersuchung des Einflusses durch den Val158Met-COMT-Polymorphismus ergab sich ein sehr heterogenes Bild, in dem sich keine eindeutig systematischen Genotyp- oder Interaktionseffekte zeigten. Während die beobachteten Befunde auf Verhaltensebene auf eine generelle Verlangsamung adulter Patienten mit ADHS im Vergleich zu gesunden Kontrollpersonen hindeuten, könnte das verminderte Aktivierungsmuster im Bereich des IFC und DLPFC während der erfolgreichen Stopp-Trials bei Patienten mit ADHS möglicherweise das zugrundeliegende funktionelle Korrelat zu den beobachteten Reaktionsunterschieden zwischen den beiden Stichproben darstellen. Obwohl Patienten mit ADHS im Vergleich zu gesunden Kontrollen aufgrund ihrer erhöhten Impulsivität defizitär erscheinen, deuten die Befunde bezüglich des Zusammenhangs zwischen selbstbewerteter und experimentell erhobener Impulsivität innerhalb der Patientengruppe einen möglichen Vorteil erhöhter I7-Impulsivitätswerte für die Reaktionsfähigkeit in der Stoppsignal-Aufgabe an. Bezüglich der Beeinflussung der erhobenen Daten durch den Val158Met-COMT-Polymorphismus lassen sich anhand der Befunde dieser Arbeit keine klaren Schlussfolgerungen ziehen. / The aim of this study was to investigate impulsivity in adult patients with Attention Deficit-/Hyperactivity Disorder (ADHD) and healthy controls, on the one hand self-rated impulsivity operationalized by the I7 questionnaire of Eysenck and on the other the executive function response inhibition as an objective correlate of impulsivity operationalized by a stop signal task. During the stop signal task the changes of oxygenated (O2Hb) and desoxygenated haemoglobin (HHb) in prefrontal cortical areas were recorded by functional near-infrared spectroscopy (fNIRS). Because the pathophysiology of ADHD seems to involve alterations in the dopaminergic neurotransmitter system, this study also investigated the possible influence of the catechol-O-methyltransferase (COMT) Val158Met polymorphism, which modulates the degradation of prefrontal dopamine. Compared to the healthy controls, patients with ADHD showed both SSRT as well as Go-RT significantly slower reaction times during the stop signal task and significantly higher values for impulsivity and empathy in the I7 questionnaire. They also showed significantly reduced increases in O2Hb in bilateral IFC for successful stop trials and a statistical trend for a reduced increase in bilateral DLPFC. For patients with ADHD the investigation of the relationship between behavioral data and self-rated impulsivity showed a significant negative association, concerning the relationship of behavioral data and functional brain data a significant negative association between SSRT and the right IFC. The investigation of the influence of the COMT Val158Met polymorphism showed no systematic genotype or interaction effects.
52

Fremdstofferkennung in Baumwolle mittels Infrarot-Analyse

Böhmer, Stephan January 2009 (has links)
Zugl.: Dresden, Techn. Univ., Diss., 2009
53

Einsatz spektroskopischer Verfahren für die Eigenschaftsbestimmung von Polyethylenterephthalat-Multifilamenten /

Linnemann, Bernhard. January 2008 (has links)
Techn. Hochsch., Diss.--Aachen, 2007.
54

Einsatz spektroskopischer Verfahren für die Eigenschaftsbestimmung von Polyethylenterephthalat-Multifilamenten

Linnemann, Bernhard January 2007 (has links)
Zugl.: Aachen, Techn. Hochsch., Diss., 2007
55

Neural correlates of delay discounting : Effects of dopamine bioavailability and implications for attention-deficit/hyperactivity disorder (ADHD)

Plichta, Michael M. January 2009 (has links)
Würzburg, Univ., Diss., 2009. / Zsfassung in dt. Sprache.
56

Entwicklung eines miniaturisierten ballongetragenen Diodenlaser-Spektrometers zur Messung von stratosphärischen Methan- und Wasserdampfkonzentrationen

Zimmermann, Rainer. Unknown Date (has links) (PDF)
Universiẗat, Diss., 2003--Heidelberg.
57

Využití NIR spektroskopie při kontrole jakosti šlehaného podmáslí

Fukačová, Ludmila January 2014 (has links)
This Diploma Thesis deals with the production of butter and buttermilk. In the introduction it informs us about the technology of butter production, there are also the history, the composition and the using butter and its assortment explained. During the production of butter other product -- buttermilk is formed as its secondary product. The Thesis also describes the technology of buttermilk production and its composition. It also focuses on the positive influence of acid buttermilk in case of its regular consumption. The positive influence is mainly caused by the content of benefited lactic acid bacteria. The final part of literature summary comes nearer to the importance and the use of spectroscopy which is measured in the infrared radiation area. It also clarifies the importance close infrared spectroscopy and also concerns with some problems of chemometrics. The problems explain the using of the statistic method in the evaluation of results of the measurement in this work. In the practical part of the Thesis forty samples of fermented buttermilk taken from supermarket chains were compared and evaluated. We were analyzing their pH, titratable acidity, dry matter, fat and protein. After finishing measuring these samples via spectrometer Nicolet FT NIR (spectra in the range from 4000 to 10 000 cm-1) the results were assessed via TQ Analyst software and by using paired T-test to the middle value.
58

Využití NIR spektroskopie při kontrole falšování kozího mléka

Ptáčková, Eva January 2014 (has links)
The aim of the thesis was to find out whether NIR spectroscopy is a suitable method for adulteration control of cow and goat milk. Also to which concentration level the method is still effective was sought. Theoretical part summarizes information about the requirements for goat milk, its composition and processing possibilities. It also contains information about food adulteration and the relevant legislation. Infrared spectroscopy is theoretically described, particularly NIR spectroscopy. The experimental part describes the procedure of qualitative analysis using NIR spectroscopy, the method of evaluation and its results. Different samples of goat milk adulterated with various proportions of cow milk were compared. Results were evaluated using discriminant analysis. NIR spectroscopy has been demonstrated as a method suitable for detecting goat milk adulteration.
59

Kinetika kontinuálního měření obsahu vlhkosti velmi jemných partikulárních materiálů. / Kinetics of the continual measurement of the actual fine particulates moisture content.

Mayerová, Kateřina January 2012 (has links)
This thesis deals with the continual measurement of the hydrated lime moisture content on the principle of spectral measurements. The theoretical part describes the basic principles of the infrared spectroscopy, Fourier transformation and near infrared spectroscopy, which are used in the process of the spectroscopy measurement of fine particulates moisture content. The practical part of the work describes experiments and the evaluation of moisture hydrated lime measuring results, using gravimetric method and NIR spectroscopy in both the laboratory conditions and the conditions of operation production of hydrated lime as well. The part of the work monitors the spectroscopy measurement moisture values as the dependence on the optical quality of hydrate limes and the process conditions of the measurements.
60

New applications for spectroscopic and chemometric studies of drugs / Neue Anwendungen für spektroskopische und chemometrische Untersuchungen von Arzneimitteln

Becht, Alexander Ulrich January 2022 (has links) (PDF)
Spectroscopic methods were established decades ago in a wide variety of fields. This also applies to the pharmaceutical field, although they initially were mostly used for identity testing or structure elucidation only. Technical developments, such as miniaturization (NMR benchtop devices), Fourier transformations (for NMR, MIR spectroscopy) or the combination with chemometric evaluation (e.g., in Process Analytical Technology, PAT), have further increased their importance and opened up new applications. The aim of this work was to investigate further new approaches and to find new applications for already established methods and to show their benefits. By means of MIR, NIR and NMR data and their chemometric evaluation (principal component analysis, PCA; hierarchical cluster analysis, HCA; linear discriminant analysis, LDA), possibilities were presented to successfully determine the manufacturer or the pharmaceutical company of various paracetamol preparations. In the course of this, various similarities and correlations between the preparations of individual companies could also be identified. For this purpose, a suitable sample preparation was developed for each spectroscopic method, and suitable measurement parameters in order to obtain reproducible spectra for the chemometric evaluation were determined. Furthermore, the results of the two unsupervised methods (HCA, PCA) were compared with each other. The HCA was able to confirm those of the PCA for the very most part. Additionally, through these methods it was possible to characterize many of the preparations based on clusters formed by comparable tablet compositions. In order to be able to measure unmortared, whole tablets using the NIR spectrometer, an attachment was developed and manufactured using 3D printing. Its functionality was demonstrated by measuring and analyzing the tablets of two different batches of nine paracetamol preparations. The batches were clearly distinguished on the basis of a PCA and a significant difference was also demonstrated by means of statistical tests. For NMR spectroscopy, a method was developed to obtain optimized "fingerprint" spectra of drug formulations. For this purpose, a 1D DOSY measurement was elaborated, in which the signals of the active ingredient could be filtered out by the appropriate choice of measurement parameters. The chemometric evaluation can thus focus on the remaining signals of the excipients, on the basis of which the preparations of the same API can be distinguished. Especially in the case of formulations that consist largely of active ingredient, data pre processing of the spectra can thus be simplified and greater importance can be assigned to the originally very small excipient signals. A quantitative 1H NMR method was developed for the comparison of a high field spectrometer (400 MHz) with a benchtop spectrometer (80 MHz) for two finished drugs. It was shown that it is possible to obtain comparable results with both instruments, but that the influence of the excipients on the signals and the lower resolution of the benchtop instrument must be taken into account. Therefore, it was not possible to obtain comparable results without further optimization of the method for one of the active ingredients. In the investigation of various reactions between APIs and excipients using DOSY, its usefulness as a screening method in stability testing was demonstrated. For this purpose, three different APIs and excipients were stressed together and the reaction mixtures were subsequently measured using DOSY. Based on the translational diffusion coefficient, the reaction products could be identified and distinguished from the active ingredients and the excipients used. The importance of thoughtful processing could also be demonstrated. If all peak heights are selected when evaluating signals split by direct spin spin coupling, this allows the detection of hidden signals as long as not all signals have the same diffusion coefficient. The selective selection of individual peak heights in the case of split signals also enables the evaluation of signals that overlap slightly. However, the limitations of this method were also shown when two signals overlap too much and differ too little in their diffusion coefficients. Hence, it has been successfully demonstrated in the various projects that the new chemometric approaches, as well as the new applications of already established methods, enable in depth findings and thus have a clear added value. / Spektroskopische Methoden haben sich schon vor Jahrzehnten in den verschiedensten Bereichen etabliert. Dies betrifft auch den pharmazeutischen Bereich, auch wenn sie hier zunächst meist nur zur Identitätsprüfung oder Strukturaufklärung verwendet wurden. Durch technische Weiterentwicklungen, wie Miniaturisierungen (NMR benchtop Geräte), Fourier Transformationen (NMR, MIR) oder die Kombination mit einer chemometrischen Auswertung (z. B. bei Process Analytical Technology, PAT), haben sie weiter an Bedeutung gewonnen, und es wurden neue Einsatzbereiche erschlossen. Das Ziel der vorliegenden Arbeit war es, weitere neue Ansätze zu untersuchen und neue Anwendungen für bereits etablierte Methoden zu finden und deren Mehrwert aufzuzeigen. Es wurden Möglichkeiten aufgezeigt mittels MIR , NIR und NMR Daten und deren chemometrischen Auswertungen (Hauptkomponentenanalyse, PCA; hierarchische Clusteranalyse, HCA; lineare Diskriminanzanalyse, LDA) erfolgreich den Hersteller bzw. das pharmazeutische Unternehmen verschiedener Paracetamol Präparate zu bestimmen. In diesem Zuge konnten Ähnlichkeiten zwischen Präparaten unterschiedlicher Firmen identifiziert werden. Um dies zu erreichen, wurde für jede spektroskopische Methode eine geeignete Probenvorbereitung entwickelt sowie geeignete Messparameter festgelegt, um reproduzierbare Spektren für die chemometrische Auswertung zu erhalten. Weiterhin wurden die Ergebnisse der zwei unüberwachten Methoden (HCA, PCA) miteinander verglichen, wobei die HCA die der PCA zum allergrößten Teil bestätigen konnte. Zudem war es möglich durch diese Methoden viele der Präparate anhand von Clustern zu charakterisieren, die durch vergleichbare Tablettenzusammensetzungen gebildet wurden. Um mit Hilfe des NIR Spektrometers intakte Tabletten vermessen zu können, wurde ein Aufsatz entwickelt und mittels 3D Druck hergestellt. Dessen Funktionalität wurde überprüft, indem Tabletten aus je zwei unterschiedlichen Chargen von neun Paracetamol Präparaten vermessen und analysiert wurden. Dabei konnten die Batches anhand einer PCA eindeutig unterschieden und zudem mittels statistischer Tests ein signifikanter Unterschied nachgewiesen werden. Für die NMR Spektroskopie wurde eine Methode entwickelt, um optimierte „Fingerprint“ Spektren von Arzneimittelformulierungen zu erhalten. Dazu wurde eine 1D DOSY Messmethode erarbeitet, bei der durch die passende Wahl der Messparameter die Signale des Wirkstoffes herausgefiltert werden konnten. Die chemometrische Auswertung konnte sich somit auf die Signale der Hilfsstoffe beschränken, anhand derer die Präparate unterschieden werden können. Vor allem bei Formulierungen, die zum größten Teil aus Wirkstoff bestehen, kann so eine Datenvorverarbeitung der Spektren vereinfacht und den ursprünglich sehr kleinen Hilfsstoffsignalen eine größere Bedeutung beigemessen werden. Für den Vergleich eines Hochfeld Spektrometers (400 MHz) mit einem „benchtop“ Spektrometer (80 MHz) wurde für zwei Fertigarzneimittel eine quantitative 1H NMR Methode entwickelt. Es konnte gezeigt werden, dass es möglich ist, mit beiden Geräten vergleichbare Ergebnisse zu erzielen. Dabei ist jedoch der Einfluss der Hilfsstoffe auf die Signale sowie die geringere Auflösung des „benchtop“ Gerätes zu berücksichtigen. Aus diesen Gründen war es ohne eine weitere Optimierung der Methode für einen der Wirkstoffe nicht möglich vergleichbare Ergebnisse mit beiden Geräten zu erzielen. Bei der Untersuchung verschiedener Reaktionen zwischen Wirk- und Hilfsstoffen mittels DOSY konnte dessen Nutzen als Screening Methode bei Stabilitätstests gezeigt werden. Für diesen Zweck wurden drei verschiedene Wirk- und Hilfsstoffe gemeinsam gestresst und die Reaktionsgemische anschließend mittels DOSY vermessen. Anhand des translationalen Diffusionskoeffizienten konnten die Reaktionsprodukte identifiziert und von den eingesetzten Wirk- und Hilfsstoffen unterschieden werden. Ebenso konnte die Bedeutung einer sorgfältigen Prozessierung demonstriert werden. Werden bei der Auswertung von Signalen, die durch direkte Spin Spin Kopplung aufgespalten wurden, alle Peakhöhen ausgewählt, erlaubt dies die Detektion von versteckten Signalen, falls nicht alle Signale den gleichen Diffusionskoeffizienten besitzen. Die selektive Auswahl einzelner Peakhöhen bei aufgespaltenen Signalen ermöglicht zudem die Auswertung von leicht überlappenden Signalen. Es wurden jedoch auch die Grenzen dieser Methode aufgezeigt: wenn zwei Signale zu stark überlappen und sich dabei in ihrem Diffusionskoeffizienten zu wenig unterscheiden. Somit konnte in den verschiedenen Projekten erfolgreich gezeigt werden, dass die neuen chemometrischen Ansätze, sowie die neuen Anwendungen bereits etablierter Methoden vertiefte Erkenntnisse ermöglichen und somit einen deutlichen Mehrwert besitzen.

Page generated in 0.0697 seconds