• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Electrospun nanofibers : an alternative sorbent material for solid phase extraction

Chigome, Samuel, Samuel Chigome 26 March 2012 (has links)
The work described in the thesis seeks to lay a foundation for a better understanding of the use of electrospun nanofibers as a sorbent material. Three miniaturised electrospun nanofiber based solid phase extraction devices were fabricated. For the first two, 10 mg of electrospun polystyrene fibers were used as a sorbent bed for a micro column SPE device (8 mm bed height in a 200 μl pipette tip) and a disk (I) SPE device (5 mm 1 mm sorbent bed in a 1000 μl SPE barrel). While for the third, 4.6 mg of electrospun nylon nanofibers were used as a sorbent bed for a disk (II) SPE device, (sorbent bed consisting of 5 5 mm 350 μm stacked disks in a 500 μl SPE barrel). Corticosteroids were employed as model analytes for performance evaluation of the fabricated SPE devices. Quantitative recoveries (45.5-124.29 percent) were achieved for all SPE devices at a loading volume of 100 μl and analyte concentration of 500 ng ml-1. Three mathematical models; the Boltzmann, Weibull five parameter and the Sigmoid three parameter were employed to describe the break through profiles of each of the sorbent beds. The micro column SPE device exhibited a breakthrough volume of 1400 μl, and theoretical plates (7.98-9.1) while disk (I) SPE device exhibited 400-500 μl and 1.39-2.82 respectively. Disk (II) SPE device exhibited a breakthrough volume of 200 μl and theoretical plates 0.38-1.15. It was proposed that the formats of future electrospun nanofiber sorbent based SPE devices will be guided by mechanical strength of the polymer. The study classified electrospun polymer fibers into two as polystyrene type (relatively low mechanical strength) and nylon type (relatively high mechanical strength).
2

Development of molecularly imprinted polymer based solid phase extraction sorbents for the selective cleanup of food and pharmaceutical residue samples

Batlokwa, Bareki Shima January 2012 (has links)
This thesis presents the development of chlorophyll, cholic acid, aflatoxin B1 molecularly imprinted polymer (MIP) particles and cholic acid MIP nanofibers for application as selective solid phase extraction (SPE) sorbents. The particles were prepared by bulk polymerization and the nanofibers by a novel approach combining molecular imprinting and electrospinning technology. The AFB1 MIP particles were compared with an aflatoxin specific immunoextraction sorbent in cleaning-up and pre-concentrating aflatoxins from nut extracts. They both recorded high extraction efficiencies (EEs) of > 97 % in selectively extracting the aflatoxins (AFB1, AFB2, AFG1 and AFG2). High reproducibility marked by the low %RSDs of < 1% and low LODs of ≤ 0.02 ng/g were calculated in all cases. The LODs were within the monitoring requirements of the European Commission. The results were validated with a peanut butter certified reference material. The chlorophyll MIP on the other hand selectively removed chlorophyll that would otherwise interfere during pesticide residue analysis (PRA) from > 0.6 to <0.09 Au in green plants extracts. The extracted chlorophyll was removed to far below the level of ≥ 0.399 Au that is usually associated with interference during PRA. Furthermore, the MIP demonstrated better selectivity by removing only chlorophyll (> 99%) in the presence of planar pesticides than the currently employed graphitized carbon black (GCB) that removed both the chlorophyll (> 88%) and planar pesticides (> 89%). For the interfering cholic acid during drug residue analysis, cholic acid MIP electrospun nanofibers demonstrated to be more sensitive and possessing higher loading capacity than the MIP particles. 100% cholic acid was removed by the nanofibers from standard solutions relative to 80% by the particles. This showed that the nanofibers have better performance than the micro particles and as such have potential to replace the particle based SPE sorbents that are currently in use. All the templates were optimally removed from the prepared MIPs by employing a novel pressurized hot water extraction template removal method that was used for the first time in this thesis. The method employed only water, an environmentally friendly solvent to remove templates to ≥ 99.6% with template residual bleeding of ≤ 0.02%.

Page generated in 0.0617 seconds